Delta OHM HD2102.1 Manual 

File Specifications

Brand: Delta OHM
Category: Measuring Instruments
Model: HD2102.1 (Manual ), prSTdq1vD.s6.
File Type: PDF
File Size: —
Pages: 36 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (36 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 21/03/2026).

Read Online

Read the Delta OHM HD2102.1 Manual  online using the built-in PDF viewer.

Key Pages of Document

01 Oct. 2004

HD2102.1 HD2102.2 The quality level of our instruments is the result of a continuous improve of product. This situation can cause possible differences comparing this manual with the instrument you bought. We regret in advance for any possible mistake in this manual. Data, drawings and descriptions included in this manual cannot be juridically in force. We reserve us the right to modify and correct the manual without prior notice. ...

1. Input for probes, 8-pole DIN45326 connector.

2. External auxiliary power supply connector input. 3. Battery symbol: displays the battery charge level. 4. Function indicators. 5. Secondary display line. 6. HOLD key/�: freezes the measurement during normal operation; in the menu, increases the current value. 7. FUNC/ENTER key: during normal operation displays the maximum (MAX), the minimum (MIN) and the average (AVG) of current measurements. In ...

1. Input for probes, 8-pole DIN45326 connector.

2. External auxiliary power supply connector input. 3. Battery symbol: displays the battery charge level. 4. Function indicators. 5. Secondary display line. 6. HOLD key/�: freezes the measurement during normal operation; in the menu, increases the current value. 7. FUNC/ENTER key: during normal operation displays the maximum (MAX), the minimum (MIN) and the average (AVG) of current measurements. In ...

The HD2102.1 and HD2102.2 are portable instruments with a large LCD display.

They measure illumination, luminance, PAR and irradiance (across VIS-NIR, UVA, UVB and UVC spectral regions or in the measurement of effective irradiance according to the UV action curve). The probes are fitted with the SICRAM automatic detection module: in addition to detection, the unit of measurement selection is also automatic. The factory calibration settings are ...

KEYBOARD AND MENU DESCRIPTION

Foreword The instrument keyboard is composed of single-function keys, like the MENU key, and double- function keys such as the ON-OFF/Auto-OFF key. In the double-keys, the function in the upper part is the “main function”, while the one in the bottom part is the “secondary function”. When the instrument is in standard measurement mode, the main function is active. In the menu or in conjunction with the FUNC key, the se ...

During normal measurement this enables the display and logging of the maximum (MAX),

minimum (MIN) and average (AVG) value of the measurements captured by the probe connected to the instrument, updating them with the acquisition of new samples. The acquisition frequency is once a second. The MAX, MIN and AVG measurements remain in the memory until the instrument is on, even after exiting the calculation function. To reset the previous values ...

This setting changes the information displayed and the immediate print of data (SERIAL key). The

data recorded using the LOG function (HD2102.2) and sent to the printer or PC through the serial port using the SERIAL function (HD2102.1 and HD2102.2), keep the chosen unit of measurement and display it. While setting the limits for Q(t) calculation, select the coefficient 3, 6 and 9 that multiplies the displayed value respectively by 103, 106, 109. + Integra ...

before entering the menu. By pressing the UNIT key, it is possible to select the coefficient 3,

6 and 9 that multiplies the displayed value respectively by 103, 106, 109. 2. TIME LIMT HOUR: indicates the number of hours for the integration time limit, after which the integral calculation is stopped. 3. TIME LIMT MIN: indicates the number of minutes for the integration time limit, after which the integral calculation is stopped. 4. TIME LIMT SEC: indicates ...

13. BAUD_RATE: indicates the frequency used for the serial communication with the PC.

Values from 1200 to 38400 baud. Use the arrows to modify this parameter and confirm using ENTER. The communication between instrument and PC (or serial port printer) only works if the instrument and PC baud rates are the same. If the USB connection is used this parameter value is automatically set (please see the details on page 21). + Reset integral Q(t) Simultaneous pr ...

SERIAL key - only HD2102.1

SERIAL/EraseLOG key - only HD2102.2 In measurement mode, this function starts and stops the data transfer to the RS232C serial output. According to the settings entered in the Print and log interval menu item, a single sample can be printed if Print and log interval=0 or a continuous indefinite printing of the measured data can be set up if Print and log interval=1…3600. The printing operation is accompanied by the display of t ...

The instrument works with probes of the LP471… series: these are photometric and radiometric

probes that measure illuminance (LP471 PHOT), irradiance (LP471 RAD, LP471 UVA, LP471 UVB and LP471 UVC), PAR (LP471 PAR) and luminance (LP471 LUM 2). All the probes, save the LUM 2, are provided with a diffuser for cosine correction. Upon turning on the instrument automatically detects the probe connected to the input: it is sufficient to connect it. ...

Simultaneously press FUNC/ENTER and UNIT-Q(t). To start and stop the integral calculation

press Start/Stop Q(t). To cancel the previous integration values and reset it, simultaneously press FUNC/ENTER and MENU/CLR-Q(t): if an integration is started without pressing the CLR- Q(t) key, the calculation will continue from the previous values. The integral calculation can be suspended at any moment pressing Start/Stop Q(t): in this status, to resume the integra ...

WARNINGS AND OPERATING INSTRUCTIONS

1. Do not bend the probe connectors or force them upward or downward. 2. Do not bend or force the contacts when inserting the probe connector into the instrument. 3. The sensors and filters should not exceed the temperature limits established with consequent irreparable degradation of their characteristics. 4. Do not drop the probes: as this could cause irreparable damage. 5. Avoid taking measurements in presence of high ...

The following table reports the indications provided by the instrument as they appear on the display,

together with their description. Display indications Explanation >>>_LOG_DUMP_or_ERAS transfer or erase data BATT TOO LOW - CHNG NOW battery discharged - replace it immediately BAUDRATE >>> baud rate value COMM STOP printing complete COMM STRT printing started DAY_ day DUMP_END data transfer complete DUMP_In_PROG >>> data transfer in progress ERR e ...

LOW BATTERY WARNING AND BATTERY REPLACEMENT

The battery symbol on the display constantly shows the battery charge status. To the extent that batteries have discharged, the symbol "empties". When the charge decreases still further it starts blinking… In this case, batteries should be replaced as soon as possible. If you continue to use it, the instrument can no longer ensure correct measurement. The memory data are maintained. If the battery charge level ...

MALFUNCTIONING UPON TURNING ON AFTER BATTERY REPLACEMENT

After replacing the batteries, the instrument may not restart correctly; in this case, repeat the operation. After disconnecting the batteries, wait a few minutes in order to allow circuit condensers to discharge completely; then reinsert the batteries. WARNING ABOUT BATTERY USE • Batteries should be removed when the instrument is not used for an extended time. • Flat batteries must be replaced i ...

SERIAL INTERFACE AND USB

The HD2102.1 and HD2102.2 instruments are fitted with an electrically isolated RS-232C serial interface; the HD2102.2 also has an USB 2.0 interface. The HD2102.1 is supplied with a serial connection cable with a Sub D 9-pole female connector on one end, and an 8-pole MiniDin on the other end. The HD2102.2 also has a cable with USB 2.0 connector on one end, and 8-pole MiniDin on the other end (code HD2101/USB). The USB connection r ...

Stop logging data

K7 & Enable REL function K6 & Disable REL function KP & Auto-power-off function=ENABLE KQ & Auto-power-off function=DISABLE RA Sample Interval= # Reading of LOG/PRINT interval set RP & 720 Battery level (Resolut. 0.01V) RUA U= W/m2 Main unit of measurement WA# & Setting LOG/PRINT interval. # is a hexadecimal number 0…D that represents the position of the interval in the list 0, 1, 5, 10, …, 3600 secon ...

Related Devices for Delta OHM HD2102.1:

HD21AB
Delta OHM HD21AB Manual 
21.03.2026 51 pages

The quality level of our instruments is the result of the continuous development of the product. This may produce some differences between the information writt User documentation for the Delta OHM HD21AB Measuring Instruments. The manual guides users through device instructions, repair references, user settings.

HD2107.1
Delta OHM HD2107.1 Operating manual
21.06.2026 38 pages

Operating manual RTD thermometers HD2107.1 – HD2107.2 www.deltaohm.com Companies / Brands of GHM English Keep for future reference. Detailed user guide for the Delta OHM HD2107.1 Thermometer. The documentation includes firmware installation, maintenance guidelines, component overview.

DO2003
Delta OHM DO2003 Manual 
17.05.2026 60 pages

The quality level of our instruments is the result of a continuous improve of product. This situation can cause possible differences comparing this manual with User operation guide for the Delta OHM DO2003 Data Loggers. The manual provides step-by-step instructions on maintenance guidelines, user preferences, repair references, technical specifications.

HD3406.2
Delta OHM HD3406.2 Operation & user’s manual
02.07.2026 44 pages

Our instruments' quality level is the results of the product continuous development. This can bring about differences between the information written in this ma User support guide for the Delta OHM HD3406.2 Thermometer. It includes usage scenarios and product maintenance, hardware setup, service instructions, maintenance guidelines.

HD32.8.8
Delta OHM HD32.8.8 Manual 
28.05.2026 48 pages

Our instruments’ quality level is the results of the product continuous development. This can bring about differences between the information written in this Product operation guide for the Delta OHM HD32.8.8 Data Loggers. This guide presents operational safety, specifications, device calibration, troubleshooting tips.

HD3409.2
Delta OHM HD3409.2 Manual 
06.08.2026 40 pages

Our instruments' quality level is the results of the product continuous development. This can bring about differences between the information written in this ma Official user manual for the Delta OHM HD3409.2 Measuring Instruments. This reference includes diagnostic information, usage examples, cleaning instructions, device operation tips.

HD32.3
Delta OHM HD32.3 Operating manual
02.09.2026 74 pages

Operating manual WBGT – PMV – PPD indices HD32.3 www.deltaohm.com English Keep for future reference. Companies / Brands of GHM User reference guide for the Delta OHM HD32.3 Other. This manual covers installation, operation, and setup, dimensions and layout, usage examples.

LPPYRA02
Delta OHM LPPYRA02 Operating manual
13.05.2026 28 pages

Operating manual Pyranometer LPPYRA02 www.deltaohm.com English Keep for future reference. Setup instructions for the Delta OHM LPPYRA02 Measuring Instruments. The document explains wiring diagrams, firmware updates, troubleshooting tips, network setup.

Measuring Instruments: Frequently Requested PDF Instructions

SYSTEM-30
Onicon SYSTEM-30 Installation and operation manual
08.05.2026 38 pages

SYSTEM-30 BTU MEASUREMENT SYSTEM BACnet MS/TP Version Installation and Operation Guide For Software Version FB5.20 or higher. 1500 North Belcher Road, Clearwate Installation and operation manual for the Onicon SYSTEM-30 Measuring Instruments. The manual provides technical details on daily usage, user preferences, software installation.

Truline ALD30
Intex Truline ALD30 Operation manual
03.06.2026 14 pages

1 WARNING: To reduce the risk of injury, user must read and understand operation manual. Handheld Laser Distance Meter WARNING: Read and become familiar with th User reference manual for the Intex Truline ALD30 Measuring Instruments. This guide includes detailed instructions for maintenance guidelines, safety guidelines, supported accessories, product maintenance.

LTI 20/20 TruSpeed
Laser Technology LTI 20/20 TruSpeed Operation & user’s manual
29.06.2026 46 pages

Laser Technology, Inc. LTI 20/20 TruSpeed ® Metric User’s Manual © LTI 2013 TruSpeed 0144809 Product operation manual for the Laser Technology LTI 20/20 TruSpeed Measuring Instruments. This guide explains technical procedures for wiring diagrams, connectivity options, maintenance procedures, technical assistance.

MP1800A
Anritsu MP1800A Operation manual
03.04.2026 192 pages

Document No.: M-W3756AE-5.0 ANRITSU CORPORATION MP1861A 56G/64Gbit/s MUX Operation Manual Fifth Edition • For safety and warning information, please read this Complete user documentation for the Anritsu MP1800A Test Equipment. The documentation guides users through setup and troubleshooting tips, device calibration, connectivity options.