Biosan FTA-1 Operating Manual

File Specifications

Brand: Biosan
Category: Medical Equipment
Model: FTA-1 (Operating Manual), prOJ1IjABRQjE
File Type: PDF
File Size: —
Pages: 16 pages

Download PDF

Download Biosan FTA-1 Manual (16 pages)

Read Online:

Read the Biosan FTA-1 Operating Manual online using the built-in PDF viewer.

Key Pages of Document

Aspirator with trap flask

for version: V.4AW Operating Manual Certificate Medical–Biological Research & Technologies ...

Warranty and Claims

8. Declaration of Conformity 3 ...

The following symbol means:

Caution! Make sure you have fully read and understood the present Manual before using the equipment. Please pay special attention to sections marked by this symbol. GENERAL SAFETY ·Use only as specified in the Operating Manual provided. ·The unit should be saved from shocks and falling. ·After transportati ...

·Do not operate the unit in premises with aggressive or explosive chemical

mixtures. Please contact manufacturer for possible operation of the unit in specific atmospheres. ·It is not allowed to use aggressive organic compounds, chlorinated solvents, strong conjugated acids for operation with the unit. ·Do not operate the unit outside the ...

FTA-1 aspirator with trap flask has been designed alcohol (or buffer) trace

quantities aspiration (removal) from microtest tube walls during DNA (RNA) purification and other macromolecule reprecipitation techniques. FTA-1 can also be used for routine operations of cells washing from cells culture medium and resuspension in buffer. The ...

Remove packing materials carefully and retain them for future shipment or

storage of the unit. Examine the unit carefully for any damage incurred during transit. The warranty does not cover in-transit damage. 3.2. Complete set. Package contents: Standard set: - FTA-1 aspirator ................................................ ...

Filter is located behind the jar output, in front of the vacuum

source. The filter should be put on so that the side of the filter with the marking “IN“ points towards the trap flask, and the side with no markings points towards the vacuum source. - screw the outlet pipe to the socket connector of the pump (Fig.1/1) located on top of the unit (turn ...

Connect external power supply unit to electric circuit.

4.2. Switch ON the unit using the Power switch on the side surface (fig.1/3). 4.3. Touch the solution surface with the aspiration tip to remove liquid from a test tube. 4.4. Use the mini-holder (Fig. 1/4) situated at the right side of the unit for washing and storing the aspiratiob tip ...

The unit is designed for operation in cold rooms, incubators and closed

laboratory rooms at ambient temperature from +4ºC to +40ºC in a non-condensing atmosphere and maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C. 5.1. Vacuum................................................. ...