Bauer SINEAX U 553 Operating Instructions Manual

File Specifications

Brand: Bauer
Category: Transducer
Model: SINEAX U 553 (Operating Instructions Manual), prRTxBBRR2fFY
File Type: PDF
File Size: —
Pages: 12 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (12 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 28/06/2026).

Read Online

Read the Bauer SINEAX U 553 Operating Instructions Manual online using the built-in PDF viewer.

Key Pages of Document

U 553 B d-f-e

131 251 01.01 Betriebsanleitung Messumformer für Wechselspannung SINEAX U 553 Mode d’emploi Convertisseur de mesure pour tension alternative SINEAX U 553 Operating Instructions Transducer for AC voltage SINEAX U 553 Camille Bauer AG Aargauerstrasse 7 CH-5610 Wohlen/Switzerland Telefon +41 56 618 21 11 Telefax +41 56 618 24 58 e-mail: [email protected] http://www.gmc-instruments.com ...

Messumformer für Wechselspannung SINEAX U 553

Sicherheitshinweise, die unbedingt beachtet werden müssen, sind in dieser Betriebsanleitung mit folgen- den Symbolen markiert: Inhaltsverzeichnis 1. Erst lesen, dann … .....................................................3 2. Kurzbeschreibung.......................................................3 3. Technische Daten .......................................................3 ...

Bild 1. Montage auf Hutschiene 35 × 15 oder 35 × 7,5 mm.

5. Elektrische Anschlüsse Elektrische Leitungen nach den Angaben auf dem Typen- schild des gelieferten Messumformers anschliessen. Unbedingt sicher stellen, dass alle Leitun- gen beim Anschliessen spannungsfrei sind! Drohende Gefahr durch hohe Eingangs- spannung oder hohe Hilfsenergie- spannung! Es ist zu beachten, … … dass die Daten, die zur Lösung der Messaufga- be erforderlich si ...

6. Messbereich-Einstellbarkeit durch

DC-Kalibrierung Die DC-Kalibrierung erfolgt auf eigene Ver- antwortung. Beim Entfernen des Abstimm- siegels erlischt die Garantie. Messeingang unbedingt sicher von gefähr- licher Spannung trennen. Einstellbarkeit: Zulässige Änderung des Messbe- reich-Endwertes, variable Empfind- lichkeit, einstellbar mit Potentio- meter P200. Einstellbereich: 0,85 - 1,15 · UN (± 15%) 100% 0 0,85 1,15 0 Ausgang Eingang 1 U ...

Convertisseur de mesure pour tension alternative SINEAX U 553

Les conseils de sécurité qui doivent impérativement être observés sont marqués des symboles ci-contre dans le présent mode d’emploi: Sommaire 1. A lire en premier, ensuite … .......................................6 2. Description brève........................................................6 3. Caractéristiques techniques ........................... ...

Fig. 1. Montage sur rail «à chapeau» 35 × 15 ou 35 × 7,5 mm.

5. Raccordements électriques Raccorder les lignes électriques selon l’indication sur la plaquette signalétique. Lors du raccordement des câbles, s’assu- rer impérativement que toutes les lignes soient hors tension! Danger imminent par tension de mesure ou par tension d’alimentation auxiliaire qui peuvent être élevées! Encliqueter le boîtier sur le rail «à chapeau ...

8. Ajustage de l’étendue de mesure par cali-

brage en CC La calibration CC se réalise aux risques de l’utilisateur. En enlevant le cache couvrant les organes d’ajustage, la garantie s’éteint. S’assurer sans faute qu’aucune tension dangereuse ne soit appliquée à l’entrée de mesure. Ajustage: Variation admissible de la plage de mesure, sensibilité variable, ajus- table par potentiomètre P200. Etendue d’ajustage: 0,85 - 1,15 · UN (� ...

Transducer for AC voltage SINEAX U 553

Safety precautions to be strictly observed are marked with following symbols in the Operating Instructions: Contents 1. Read first and then … .................................................9 2. Brief description .........................................................9 3. Technical data ............................................................9 4. Mounting.............. ...

Fig. 1. Mounting onto top-hat rail 35 × 15 or 35 × 7.5 mm.

5. Electrical connections Connect the electrical conductors acc. to the instructions on type label. Make sure that all input cables are not live (potential-free) when making the connec- tions! Impending danger by high input voltage or high power supply voltage! Also note that, … … the data required to carry out the prescribed measurement must correspond to those marked on the namep ...

6. Adjustable measuring range by DC cali-

bration DC calibration is performed at the user’s risk. The warranty is void if the calibration seal is removed. Reliably isolate the measuring input from dangerous voltages. Setting: Admissible alteration of full scale output, variable sensitivity, adjust- able with potentiometer P200. Setting range: 0.85 - 1.15 · UN (± 15%) 100% 0 0.85 1.15 0 Output Input 1 UN – Remove calibration seal (small sti ...

10. Croquis d’encombrement

10. Dimensional drawing 70 69,1 114,1 112,5 4 5 1 10 9 8 7 6 2 11 3 12 13 Bild 8. Gehäuse P13/70 auf Hutschiene (35 × 15 mm oder 35 × 7,5 mm, nach EN 50 022) aufgeschnappt. Fig. 8. Boîtier type P13/70 encliqueté sur rail «à chapeau» (35 × 15 mm ou 35 × 7,5 mm, selon EN 50 022). Fig. 8. Housing type P13/70 clipped onto a top-hat rail (35 × 15 mm or 35 × 7.5 mm, acc. to EN 50 022). ...

Related Devices for Bauer SINEAX U 553:

BG 25
Bauer BG 25 Instruction manual
29.07.2026 183 pages

Instruction Manual BG 25 BAUER Maschinen GmbH P.O. Box 12 60  D-86522 Schrobenhausen  Germany Phone: +49 8252 97-0  Fax: +49 8252 97-13 59 BK000513.wmf Operating manual for the Bauer BG 25 Drill. This manual outlines safety protocols, support details, shutdown procedures, compatibility information.

1817C-B
Bauer 1817C-B Owner's manual & safety instructions
13.03.2026 12 pages

Visit our website at: http://www.harborfreight.com Email our technical support at: [email protected] Owner’s Manual & Safety Instructions Save Technical setup manual for the Bauer 1817C-B Sander. It outlines maintenance guidelines and safety, troubleshooting tips, setup instructions, usage examples.

Magnum SM 540
Bauer Magnum SM 540 Operating manual
04.06.2026 30 pages

OPERATING MANUAL for Gear Pumps Magnum SM 540; SM 1000 / SM 2000 without and with self-priming unit Technical operations guide for the Bauer Magnum SM 540 Water Pump. The guide offers support information and adjustment procedures, device instructions, performance details, technical specifications.

Junior II-B-F01
Bauer Junior II-B-F01 Instruction manual
20.04.2026 46 pages

Technical setup manual for the Bauer Junior II-B-F01 Air Compressor. The guide offers support information and performance details, user preferences, startup procedures.

20115E-B
Bauer 20115E-B Owner's manual & safety instructions
13.03.2026 16 pages

Visit our website at: http://www.harborfreight.com Email our technical support at: [email protected] Owner’s Manual & Safety Instructions Save Instruction reference guide for the Bauer 20115E-B Trimmer. The document presents startup procedures, service procedures, device calibration.

1695E-B
Bauer 1695E-B Owner's manual & safety instructions
06.04.2026 16 pages

Visit our website at: http://www.harborfreight.com Email our technical support at: [email protected] Owner’s Manual & Safety Instructions Save Comprehensive instruction manual for the Bauer 1695E-B Drill. The manual outlines technical specifications and connectivity setup, technical overview, device reset instructions.

RAINSTAR A3
Bauer RAINSTAR A3 Operating manual
22.07.2026 36 pages

OPERATING MANUAL for RAINSTAR A3 Version VII-2012 Art. No. 827 9978 Technical guide for the Bauer RAINSTAR A3 Farm Equipment. This reference manual explains startup procedures, safety features, operational procedures, component overview.

Ecostar 6000
Bauer Ecostar 6000 Update manual
11.07.2026 9 pages

Update Guide c Bauer GmbH V3.0 Ecostar 6000 Product documentation for the Bauer Ecostar 6000 Farm Equipment. This manual provides guidance on warranty information, service procedures, dimensions and layout.

Transducer: Frequently Requested PDF Instructions

GT-RK1
Gems GT-RK1 Manual 
13.08.2026 16 pages

Doc.No.1103 Rev.013 2016-08-16 Tel: +86-755-29644311 Fax: +86-755-29644383-816 Email: [email protected] GEMS NAVIGATION LIMITED Room 301,Hua Chuang Installation guide for the Gems GT-RK1 Transducer. The guide provides instructions on maintenance procedures, diagnostic information, technical overview, technical specifications.

SD1
SOLIDDRIVE SD1 Installation & use manual
01.08.2026 4 pages

I N D U C T I O N D Y N A M I C S ® INSTALLATION & USE GUIDE for SolidDrive SD1 into walls and ceilings before drywall I N D U C T I O N D Y N A M I C S ® T User guide for the SOLIDDRIVE SD1 Transducer. This documentation details performance optimization, wiring diagrams, system configuration.

SP10
Sitron SP10 Operation & user’s manual
26.07.2026 27 pages

USER MANUAL Installation, Operation and Maintenance Manual Pressure Transmitters Series: SP Complete installation manual for the Sitron SP10 Transducer. This manual elaborates on hardware setup, firmware installation, operating modes.

BK-CT
The Guitammer Company BK-CT Operation & user’s manual
18.04.2026 8 pages

Technical guide for the The Guitammer Company BK-CT Transducer. It describes operating procedures and operational procedures, device instructions, installation guides.