BASF EXACTUS IFX-21 Operation & User’s Manual

Text of the manual

IFX-21 User Guide

BASF Contact Information 7/12/2019 V004 2 of 22 1. CONTACT INFORMATION TECHNICAL 4011 SE International Way, Suite 604 Portland, OR 97222 Phone: (503) 794-4073 Fax: (503) 794-5591 PURCHASING 46820 Fremont Blvd. Fremont, CA 94538 Phone: (510) 490-2150 Fax: (510) 252-1871 Copyright© 2019 BASF Corporation. All rights reserved. EXACTUS® and TemperaSure are registered trademarks of BASF Corporation. The data contained in this publication are based on our current knowledge and experience. In view of the many factors that may affect processing and application of our product, these data do not relieve processors from carrying out their own investigations and tests; neither do these data imply any guarantee of certain properties, nor the suitability of the product for a specific purpose. Any descriptions, drawings, photographs, data, proportions, weights, etc. given herein may change without prior information and do not constitute the agreed contractual quality of the product. It is the responsibility of the recipient of our products to ensure that any proprietary rights and existing laws and legislation are observed. Although all statements and information in this publication are believed to be accurate and reliable, they are presented gratis and for guidance only, and risks and liability for results obtained by use of the products or application of the suggestions described are assumed by the user. NO WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH. Statements or suggestions concerning possible use of the products are made without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe any patent. The user should not assume that toxicity data and safety measures are indicated or that other measures may not be required. ©2019 BASF Corporation.

IFX-21 User Guide

BASF Contents 7/12/2019 V004 3 of 22 2. CONTENTS 1. Contact Information ................................................................................................................................ 2 2. Contents ................................................................................................................................................... 3 3. Product Overview .................................................................................................................................... 4 Description and Intended Use ................................................................................................................ 4 Certifications and Approvals .................................................................................................................. 4 Identification ........................................................................................................................................... 4 Device Overview .................................................................................................................................... 4 4. Installation and Commission ................................................................................................................. 5 Software Minimum Requirements .......................................................................................................... 5 Transportation and Storage ................................................................................................................... 5 Mounting ................................................................................................................................................ 6 Device Wiring ......................................................................................................................................... 7 5. Device Operation and Setup ................................................................................................................ 10 Overview of Connection Methods ........................................................................................................ 10 Value Display and Indicating LEDs ...................................................................................................... 11 Device Configuration ............................................................................................................................ 12 The Configuration Menu ...................................................................................................................... 13 Analog Output Operation ..................................................................................................................... 14 Analog Output Configuration ................................................................................................................ 14 6. Maintenance .......................................................................................................................................... 14 7. Specifications ........................................................................................................................................ 15 General ................................................................................................................................................ 15 Technical .............................................................................................................................................. 15 8. Warnings ................................................................................................................................................ 18 9. Troubleshooting .................................................................................................................................... 18 Troubleshooting Instructions ................................................................................................................ 18 Repair, Service, and Returns ............................................................................................................... 19 Disposal ............................................................................................................................................... 19 10. Appendix .............................................................................................................................................. 20 7-Segment Display ............................................................................................................................. 20 MODBUS/TCP ................................................................................................................................... 21 MODBUS/RTU (RS485) Implementation ........................................................................................... 21 MODBUS register map ...................................................................................................................... 22

IFX-21 User Guide

BASF Product Overview 7/12/2019 V004 4 of 22 3. PRODUCT OVERVIEW DESCRIPTION AND INTENDED USE The IFX-21 is a smart device for re-transmission, monitoring, and break out of EXACTUS® pyrometer communications in industrial environments. It continuously buffers pyrometer output and makes the readings available to various isolated ports and protocols, including a user defined passive 4-20mA analog signal. CERTIFICATIONS AND APPROVALS IDENTIFICATION The IFX-21 features a Nameplate as seen in Figure 1. FIGURE 1: EXAMPLE NAMEPLATE 1. Manufacturer and Product ID 2. Order Code and Serial Number 3. Power supply and current consumption 4. Ambient temperature range 5. Device MAC address 6. Device and Firmware version 7. Approval Logo DEVICE OVERVIEW The IFX-21 is a DIN rail mountable plastic enclosure with a number of ports on its top, bottom, and front. The top has two sets of 4 spring terminals and one RJ45 port. The bottom has one set of 4 spring terminals and two RJ45 ports. The front has a clear polycarbonate door which covers a 5 character display, 2 indicating LED’s, and a USB service port.

IFX-21 User Guide

BASF Installation and Commission 7/12/2019 V004 5 of 22 3.4.1. PORT CALLOUT FIGURE 2: DEVICE OVERVIEW 1. Analog outputs 2. Device power input 3. Pyrometer port 4. 5 Character display 5. USB mini-B PC service port 6. Power and Error indication LEDs 7. TIA 485-A (RS485) port 8. Ethernet TCP/IP 2 port switch Refer to section 7.2 for additional technical information about these ports. 4. INSTALLATION AND COMMISSION SOFTWARE MINIMUM REQUIREMENTS  Windows 7, 8.1, and 10 compatible.  Windows 10 only for USB service port connection  TemperaSure Version: 5.7.0.0 or later  Pyrometer Models EX#-100 Firmware: 3.0.1.3 or later  Pyrometer Models EX#-#10 Firmware: 9.3.0.0 or later TRANSPORTATION AND STORAGE The device should be transported and stored such that it is protected from impact, condensing atmospheres, and influx of liquids or contaminants. Permitted storage temperature range: -40 to 85°C (-40 to +185°F)

Other Control Unit Manuals