ACV Smart SL 100 Installation Operation & Maintenance

File Specifications

Brand: ACV
Category: Boiler
Model: Smart SL 100 (Installation Operation & Maintenance), pr/IdPex4Hxtg
File Type: PDF
File Size: —
Pages: 40 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (40 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 29/05/2026).

Read Online

Read the ACV Smart SL 100 Installation Operation & Maintenance online using the built-in PDF viewer.

Key Pages of Document

Smart SL & SLEW

100 - 130 - 160 - 210 - 240 Installation, Operation & Maintenance Instructions for the User and the Installer A1007850 - 661Y1700 • F ...

Smart SL-SLEW : A1007850 - 661Y1700 • F - draft

Table of Contents GENERAL RECOMMENDATIONS ...............................................................4 Energy labelling .....................................................................................................................................................5 Rating Plate .......................................................................................................................... ...

Smart SL-SLEW: A1007850 - 661Y1700 • F - draft

Table of Contents STARTING UP ...........................................................................................28 Safety Instructions to Fill the Tank .....................................................................................................28 Filling .......................................................................................................................................... ...

We accept no liability should any damage result from the failure to comply with the ins-

tructions contained in this technical manual. Essential recommendations for safety • It is strictly prohibited to carry out any modifications to the appliance without the manufacturer’s prior and written agreement. • The product must be installed by a qualified engineer, in accordance with applicable local standards and regulations. • The installation must ...

Smart SL-SLEW: A1007850 - 661Y1700 • F - draft

User's Guide Key : 1. Control thermostat [60/80°C] - To set the domestic hot water (DHW) temperature. 2. Fuse FF 12,5 Amp - To provide an electric protection to the appliance. 3. Summer / Winter switch - To activate the heating pump of the heating system/deacti- vate the electrical heating element ( - winter position) or activate the electrical heating element/deactivate the heating system pump ( - summer ...

Smart SL-SLEW : A1007850 - 661Y1700 • F - draft

Appliance Description SL 100 - 130 - 160 - 210 - 240 EN 8 1 2 10 4 5 6 7 8 9 11 12 14 15 13 8 3 MODELS - SL / SLEW 100 - 130 - 160 - 210 - 240 SL : Storage water tanks, to be installed on the floor or either vertically or horizontally on the wall, that work within a heating system. SLEW : Storage water tanks, to be installed vertically on the wall, that can work within a heating system, or independently as ...

Smart SL-SLEW: A1007850 - 661Y1700 • F - draft

Appliance Description SLEW 100 - 130 - 160 - 210 - 240 1. Auxiliary connection DHW 2. Cold water inlet connection 3. Control thermostat 4. Flow connection (primary circuit) 5. Polyurethane foam insulation 6. Return connection (primary circuit) 7. Outer steel tank (primary circuit) 8. Manual air bleed valve (x 2 - SL Mod- els) 9. Hot water outlet connection 10. Polypropylene top lid 11. Stainless ste ...

Smart SL-SLEW : A1007850 - 661Y1700 • F - draft

Technical Characteristics DIMENSIONS AND MAIN CHARACTERISTICS Tank dimensions SL / SLEW 100 130 160 210 240 A mm 865 1,025 1,225 1,497 1,744 B mm 629 789 989 1,261 1,508 C mm 365 525 725 997 1,244 Empty weight Kg 49 55 65 75 87 EN 10 A B 264 C 360 325 295 145 565 A B 264 C 360 325 295 145 565 SL A B 264 C 565 360 325 295 145 A B 264 C 565 360 325 295 145 SLEW ...

Smart SL-SLEW: A1007850 - 661Y1700 • F - draft

Technical Characteristics Main characteristics SL/SLEW 100 130 160 210 240 Total capacity L 105 130 161 203 242 Primary capacity L 30 31 35 39 42 DHW capacity L 75 99 126 164 200 Primary connection [F] " 1 1 1 1 1 DHW connection [M] " 3/4 3/4 3/4 3/4 3/4 Auxiliary DHW loop connection [M] " 3/4 3/4 3/4 3/4 3/4 Primary pressure drop* mbar 22.6 26.8 26.8 41.6 47.3 Heating surface area m² 1.03 1.26 1.54 1.94 2 ...

Smart SL-SLEW : A1007850 - 661Y1700 • F - draft

Technical Characteristics Main characteristics SL 100 130 160 210 240 Rated voltage V~ 230 230 230 230 230 Rated frequency Hz 50 50 50 50 50 Max. Amp rating A 6 6 6 6 6 ELECTRICAL CHARACTERISTICS Wiring diagram 1. 230 Volt supply cord 2. Control thermostat [60/80°C] 3. Manual reset high limit thermostat [89°C max.] 4. Summer / Winter switch 5. Fuse FF 12,5 A 6. Electric heating element 7. Charging pump ...

Smart SL-SLEW: A1007850 - 661Y1700 • F - draft

Technical Characteristics Main characteristics SLEW 100 130 160 210 240 Rated voltage V~ 230 230 230 230 230 Rated frequency Hz 50 50 50 50 50 Electrical consumption with electrical heating element W 2,200 2,200 2,200 2,200 2,200 Rated current with electrical heating element A 10 10 10 10 10 13 EN c 2 1 t t L1 PE N M T1 T2 Br Bk Or W B Y/Gr B Y/Gr B B Gr Br B B Bk B Bk 7 3 2 4 5 6 230 V ~50Hz B Y/Gr Br 1 8 ...

Smart SL-SLEW : A1007850 - 661Y1700 • F - draft

Technical Characteristics PERFORMANCE DHW performance* SL / SLEW 100 130 160 210 240 Peak flow at 40 °C L/10' 236 321 406 547 700 Peak flow at 60 °C L/10' 117 161 209 272 337 Peak flow first hour at 40 °C L/60' 784 1,063 1,349 1,820 2,319 Peak flow first hour at 60 °C L/60' 384 549 689 913 1,165 Constant flow at 40 °C L/h 658 890 1,132 1,527 1,943 Constant flow at 60 °C L/h 320 465 576 769 994 Power ...

Connections (electrical, hydraulic) must be carried out in accordance with

applicable standards and regulations. • If the water drawing off point is far from the tank, installing an auxiliary DHW loop can allow to get hot water more quickly at all times. Essential instructions for the correct operation of the system • The tank must be installed in a dry and protected area. • Install the appliance to ensure ...

Essential instructions for the safety of persons and the environment

• Hot water can burn! In the event of small amounts of hot water repeatedly being drawn off, a stratification effect can develop in the tank. The upper hot water layer may then reach very high temperatures. • ACV recommends using a pre-set thermostatic mixing valve in order to provide hot water at a maximum of 60°C. • Water heated to wash clothes, dishes and for other uses can ca ...

Smart SL-SLEW: A1007850 - 661Y1700 • F - draft

Installation Package • One SL/SLEW hot water tank. • One multilingual Installation, Operation and Maintenance Instructions. • One wall-mounting kit with support and flow diverter • One energy label PACKING CONTENTS All appliances are delivered, tested and packaged separately. General Remark • The hot water tank may be installed either on the floor or on a wall using the provided wall-mounting kit ...

Smart SL-SLEW : A1007850 - 661Y1700 • F - draft

Installation Vertical wall hung position : domestic water connections at the bottom side 1 2 Horizontal wall hung position : domestic water connections on the right side 1 2 ACV does not recommend the installation in a horizontal position, as it will increase heat-up time and reduce DHW performances. CH flow rate > 2000 l/h CH flow rate ≤ 2000 l/h CH in Air vent Flow diverter TANK INSTALLATION : SL 100 - ...

Smart SL-SLEW: A1007850 - 661Y1700 • F - draft

Installation TANK INSTALLATION : SLEW 100 - 130 - 160 - 210 - 240 Vertical wall hung position : domestic water connections at the bottom side SLEW SLEW Flow diverter 19 EN ...

G3 REQUIREMENTS AND GUIDANCE

Discharge pipe from safety valves The Building Regulation G3 requires that any discharge from an unvented system is con- veyed to where it is visible, but will not cause danger to persons in or about the building. The tundish and discharge pipes should be fi tted in accordance with the requirements and guidance notes of Building Regulation G3. The G3 Requirements and Guidance sections 3.50 - 3.63 are detailed below. For discha ...

Related Devices for ACV Smart SL 100:

281230-30-1
ACV 281230-30-1 Installation manual
28.04.2026 2 pages

9. Attach mounting brackets and facia plate to 1-DIN head unit 10. Remove switches and control unit from OEM panel 11. Mount switches and control unit to facia Maintenance and service manual for the ACV 281230-30-1 Automobile Accessories. The manual guides users through backup procedures, user settings, operating conditions.

381296-07-1
ACV 381296-07-1 Installation manual
24.06.2026 2 pages

3 1 2 4 3 4 © 09/2014 ALL RIGHTS RESERVED. Technical changes possible. No liability for misprints. Compatible with these double DIN devices Double DIN navigati Instruction guidebook for the ACV 381296-07-1 Automobile Accessories. The document details configuration and wiring diagrams, maintenance, technical assistance.

381094-19
ACV 381094-19 Installation manual
19.07.2026 2 pages

1 2 3 4 © 07/2009 ALL RIGHTS RESERVED. Technical changes possible. No liability for misprints. Compatible with these Double DIN double DIN devices Double DIN N Detailed product documentation for the ACV 381094-19 Automobile Accessories. This manual explains reset instructions, installation steps, system checks.

ETS 09
ACV ETS 09 Specification
14.08.2026 2 pages

Official operating instructions for the ACV ETS 09 Boiler. This guide explains technical procedures for operational safety, technical specifications, setup validation.

381275-15-1
ACV 381275-15-1 Installation manual
31.07.2026 2 pages

Double DIN Set contents • (1) Facia Plate • (2) Mounting Bracket Right • (3) Mounting Bracket Left • (4) flat headed screw 1 2 4 4 3 Compatible with the Device instruction guide for the ACV 381275-15-1 Automobile Accessories. It details operating modes and device safety checks, safety features, basic operation.

E-Tech W 09 Mono
ACV E-Tech W 09 Mono Installation operation & maintenance
30.06.2026 64 pages

E-Tech W 09 - 15 Mono & Tri 09 - 15 - 22 - 28 - 36 Tri A1007841_664Y7800 • A Installation, Operation & Maintenance Instructions for the User and the Installer Full operation manual for the ACV E-Tech W 09 Mono Boiler. The manual describes repair references, setup tips, component replacement.

381094-28
ACV 381094-28 Installation manual
24.07.2026 2 pages

8. Reinstall hazard light switch bar Reinstall dashboard panel All installation work must be performed by a qualified professional installer only. The manufactu Operation instructions for the ACV 381094-28 Automobile Accessories. It provides instructions for technical troubleshooting, wiring diagrams, adjustment procedures.

381178-35
ACV 381178-35 Installation manual
03.06.2026 2 pages

© 05/2013 ALL RIGHTS RESERVED. Technical changes possible. No liability for misprints. 1 3 4 4 2 Kit Content (1) facia plate (2) mounting bracket right (3) mou Instructions for safe usage of the ACV 381178-35 Automobile Accessories. The document offers guidance on connectivity options, dimensions and layout, device operation tips.

Boiler: Frequently Requested PDF Instructions

VITOSOL 100-F
Viessmann VITOSOL 100-F Technical data manual
10.07.2026 4 pages

V VV VIIIITTTTO O O OS SS SO O O OLLLL 11110 00 00 00 0----FFFF Flat plate solar collectors for the harnessing of solar energy Panels with 25 ft.2 (2.32 m2) abs Installation and maintenance guide for the Viessmann VITOSOL 100-F Heating System. The documentation guides users through setup and software configuration, performance guidelines, user preferences.

CHS-85
CHS CHS-85 Installation and operating instructions manual
11.08.2026 93 pages

Service and user manual for the CHS CHS-85 Boiler. It explains usage scenarios and maintenance, dimensions and layout, setup validation, technical guidelines.

503-2003
Raypak 503-2003 Brochure & specs
03.08.2026 8 pages

Models 504 thru 2004 Category I with vertical vent Models 503 thru 2003 Category IV Venting Up to 87% thermal efficiency! User instruction booklet for the Raypak 503-2003 Water Heater. It includes troubleshooting procedures and hardware instructions, power management, support details, setup guidelines.

ACQUAHOME 32 B
thermital ACQUAHOME 32 B Installation and maintenance manual
24.08.2026 60 pages

ACQUAHOME 32 B - 32 BS INSTALLATION AND MAINTENANCE MANUAL Maintenance and service manual for the thermital ACQUAHOME 32 B Boiler. It details operating modes and supported accessories, installation guides, software updates.