BELT ALIGNMENT / MOTION &
BROKEN / SLACK CHAIN MONITOR
INSTALLATION INSTRUCTIONS
OPERATION MANUAL
Part No. WDA3V34C
APPROVED
Class II Div. 1
C
US
®
Exposed moving parts
will cause severe injury
or death.
Lockout power before
removing cover or
inspection door.
DANGER
Exposed rotating parts
will cause severe injury
or death.
Lockout power before
removing cover or
inspection door.
DANGER
Exposed buckets and
moving parts will cause
severe injury or death.
Lockout power before
removing cover or
inspection do
TABLE OF CONTENTS
CUSTOMER SAFETY RESPONSIBILITIES
Page 4 - 5
PRODUCT OVERVIEW
Page 6
SPECIFICATIONS
Page 6
DIMENSIONS
Page 7
INSTALLATION - BUCKET ELEVATOR
Page 8
BUCKET ELEVATOR PLACEMENT DIAGRAMS
Page 9 - 12
INSTALLATION - CONVEYORS
Page 13 - 14
STANDARD WIRING DIAGRAMS
Page 15 - 16
TESTING & COMMISSIONING
Page 17
SENSOR CALIBRATION
Page 17
TROUBLESHOOTIN
Dear 4B Customer:
Congratulations on your purchase. 4B appreciates your business and is pleased you
have chosen our products to meet your needs.
Please read in its entirety and understand the literature accompanying the product before
you place the product into service. Please read the safety precautions carefully before
operating the product. With
3. SELECT A QUALIFIED AND COMPETENT INSTALLER
Correct installation of the product is important for safety and performance. If you have
not asked 4B to perform the installation of the unit on your behalf, it is critical for the
safety of your operation and those who may perform work on your operation that you
select a qualified and competent electrica
12 to 24 VDC ± 10%
Supply Current -
65 mA
LED Indicator -
Green (Flashing) - Target Detected
Green (Off) - No Target Detected
Outputs (Max) -
1. 100 mA Sink
2. 50 mA Source
Detection Range -
Adjustable: 1 - 3 Inches (25 - 75 mm) for 1 Inch Diameter Ferrous Target
Detection Rate -
20 - 2,000 PPM (Pulses Per Minute)
Cable -
9 ft. Long
9 ft. Cable
ALL DIMENSIONS
IN INCHES
4-1/16
3-7/16
4-1/16
3-7/16
1
Ø 5/16 x 4
Ø 2
6-1/16
5-3/16
7/8
2
LED
1/2 Inch NPT
Threaded
Entry
Sensor Depth
Adjustment Bolt
Sensor Mount
(WDAMB)
Sensor Body
2-3/16
• Rotating machinery can cause serious injury or death
• Always lockout and tagout the machine prior to installation
INSTALLATION - BUCKET ELEVATOR
Sensors are placed in pairs at the head and boot on the up side of the elevator leg (figure 1). Refer to
the BUCKET ELEVATOR PLACEMENT DIAGRAMS section regarding proper sensor positioning for
BUCKET ELEVATOR PLACEMENT DIAGRAMS
OPTION 1 -
Steel Elevator Buckets
Mount WDA sensor on
side of elevator leg to
target the sides of the
rotating buckets
(Figure 2).
OPTION 2 -
Plastic Elevator Buckets
Mount WDA sensor on
back side of elevator leg
to target the elevator bolts
used to secure the plastic
buckets (Figure 6).
X
X - Mount WDA sensor
with
Metal Elevator Bucket
PULSE
PULSE
NORMAL RUNNING
Metal Elevator Bucket
PULSE
NO PULSE
BELT MISALIGNMENT
Figure 2 -
Recommended WDA
Sensor Placement For
Metal Elevator Buckets
3 in.
Minimum
WDA Sensor
Probe Position
Figure 3 -
Elevator Leg Side View
Belt
NOTE -
If using stainless steel elevator
buckets and bolts (non-ferrous),
use PTFE coated steel fe