4B WDA3V34C Operation Manual

Text of the manual

BELT ALIGNMENT / MOTION &

BROKEN / SLACK CHAIN MONITOR INSTALLATION INSTRUCTIONS OPERATION MANUAL Part No. WDA3V34C APPROVED Class II Div. 1 C US ®

Exposed moving parts

will cause severe injury or death. Lockout power before removing cover or inspection door. DANGER Exposed rotating parts will cause severe injury or death. Lockout power before removing cover or inspection door. DANGER Exposed buckets and moving parts will cause severe injury or death. Lockout power before removing cover or inspection do

TABLE OF CONTENTS

CUSTOMER SAFETY RESPONSIBILITIES Page 4 - 5 PRODUCT OVERVIEW Page 6 SPECIFICATIONS Page 6 DIMENSIONS Page 7 INSTALLATION - BUCKET ELEVATOR Page 8 BUCKET ELEVATOR PLACEMENT DIAGRAMS Page 9 - 12 INSTALLATION - CONVEYORS Page 13 - 14 STANDARD WIRING DIAGRAMS Page 15 - 16 TESTING & COMMISSIONING Page 17 SENSOR CALIBRATION Page 17 TROUBLESHOOTIN

Dear 4B Customer:

Congratulations on your purchase. 4B appreciates your business and is pleased you have chosen our products to meet your needs. Please read in its entirety and understand the literature accompanying the product before you place the product into service. Please read the safety precautions carefully before operating the product. With

3. SELECT A QUALIFIED AND COMPETENT INSTALLER

Correct installation of the product is important for safety and performance. If you have not asked 4B to perform the installation of the unit on your behalf, it is critical for the safety of your operation and those who may perform work on your operation that you select a qualified and competent electrica

12 to 24 VDC ± 10%

Supply Current - 65 mA LED Indicator - Green (Flashing) - Target Detected Green (Off) - No Target Detected Outputs (Max) - 1. 100 mA Sink 2. 50 mA Source Detection Range - Adjustable: 1 - 3 Inches (25 - 75 mm) for 1 Inch Diameter Ferrous Target Detection Rate - 20 - 2,000 PPM (Pulses Per Minute) Cable - 9 ft. Long

9 ft. Cable

ALL DIMENSIONS IN INCHES 4-1/16 3-7/16 4-1/16 3-7/16 1 Ø 5/16 x 4 Ø 2 6-1/16 5-3/16 7/8 2 LED 1/2 Inch NPT Threaded Entry Sensor Depth Adjustment Bolt Sensor Mount (WDAMB) Sensor Body 2-3/16

• Rotating machinery can cause serious injury or death

• Always lockout and tagout the machine prior to installation INSTALLATION - BUCKET ELEVATOR Sensors are placed in pairs at the head and boot on the up side of the elevator leg (figure 1). Refer to the BUCKET ELEVATOR PLACEMENT DIAGRAMS section regarding proper sensor positioning for

BUCKET ELEVATOR PLACEMENT DIAGRAMS

OPTION 1 - Steel Elevator Buckets Mount WDA sensor on side of elevator leg to target the sides of the rotating buckets (Figure 2). OPTION 2 - Plastic Elevator Buckets Mount WDA sensor on back side of elevator leg to target the elevator bolts used to secure the plastic buckets (Figure 6). X X - Mount WDA sensor with

Metal Elevator Bucket

PULSE PULSE NORMAL RUNNING Metal Elevator Bucket PULSE NO PULSE BELT MISALIGNMENT Figure 2 - Recommended WDA Sensor Placement For Metal Elevator Buckets 3 in. Minimum WDA Sensor Probe Position Figure 3 - Elevator Leg Side View Belt NOTE - If using stainless steel elevator buckets and bolts (non-ferrous), use PTFE coated steel fe