40" To Finished Floor

6300/6400R/RF EXIT INSTALLATION INSTRUCTION RIM DEVICE Phone: 833-2-PDQTEC | www.pdqlocks.com 2. SIZE DEVICE  Standard lengths are for 36" or 48" door. Device must be cut for other lengths.  Mark length with tape – length equals device size minus desired door size (for 30" door = cut 6" off 36" device) ensuring a square cut. 639400 Rev0 – 12/12/21 1. PREPARE DOOR  Prepare door and frame according to template.  Refer to trim template if installing trim. 3. INSTALL DEVICE  Install device and trim with 1/4-20 screws from pack #639043.  Device can be surface mounted to the door, optional sex nuts are available, device is through bolted if using trim. Panic Fire Alarm MLR 36" Device 6" 8" 2" 3" 48" Device 12" 14" 8" 9" Maximum cut off length: Reinforced Steel or Aluminum Door Surface Mount: Drill/Tap push side for 1/4-20 Solid Wood Door Drill 1/8" Pilot Hole for #10 Wood Screw All Others Use optional Sex Bolts. Drill push side with 9/32" drill bit. Drill pull side with 3/8" drill bit. Mounting Options:

639400 Rev0 – 12/12/21

6300/6400R/RF EXIT INSTALLATION INSTRUCTION RIM DEVICE 5. INSTALL HEAD COVER  Slide head cover onto exit device  Install 4 mounting screws 6. INSTALL STRIKE  Install strike with roller toward door face using two #10-24 pan head screws.  Adjust strike to secure door.  Install flat head locking screw by drilling and tapping for #10-24 after final adjustment is achieved. 4. INSTALL END CAP  Slide end cap into rail. Ensure rail is level. Mark the centers of the slots.  Remove end cap then drill holes using the chart from Step 3.  Reinstall end cap and fasten with screws.