Crestron MC2W Operation Manual
Text of Crestron MC2W Operation Manual
This document was prepared and written by the Technical Documentation department at:
Crestron Electronics, Inc.
15 Volvo Drive
Rockleigh, NJ 07647
1-888-CRESTRON
All brand names, product names and trademarks are the property of their respective owners.
©2003 Crestron Electronics, Inc.
2-Series Professional Media Controller with RF
Contents
2-Series Professional Media Controller with RF: MC2W
1
Introduction ...............................................................................................................................1
Features and Functions................................................................................................1
Specifications ..........................................................
2-Series Professional Media Controller with RF 2-Series Professional Media
Controller with RF: MC2W
Introduction
Features and Functions
The Crestron® 2-Series Professional Media Controller with RF (MC2W) is designed
for smaller home and commercial systems. The MC2W provides connectivity for
communication and control of Cresnet®, one-way wireless (RF), and third party
devices. With speed, power, and memory, the 2-Series control systems are i
2-Series Professional Media Controller with RF Crestron MC2W
instruction set is also fully compatible with existing Crestron SIMPL Windows and
SIMPL+ programs.
The MC2W has the capability to operate as a standalone 2-Series control system or
as a Cresnet device as part of a 2-Series control system.
Master Mode
In master mode, the MC2W is a standalone 2-Series control system that can control
IR, serial, or Cresnet devices.
Slave Mode
In slave mode, the MC2W
2-Series Professional Media Controller with RF MC2W Specifications (continued)
SPECIFICATION
DETAILS
Network Power Fuse
Rating
Internal 2A self-resetting fuse
4
Environmental
Temperature
41° to 113°F (5° to 45°C)
Environmental Humidity
10% to 90% RH (non-condensing)
Dimensions & Weight
Height: 1.7 in (4.32 cm)
Width:
19.0 in (48.26 cm) – with ears
17.03 in (43.24 cm) – without ears
Depth:
8.5 in (21.59 cm)
Weight: 4.3 lbs (2.0 kg)
1.
2-Series Professional Media Controller with RF Crestron MC2W
Physical Views of the MC2W
17.03 in
(43.24 cm)
1.70 in
(4.32 cm)
8.50 in
(21.59 cm)
Controls and Indicators
The MC2W front panel indicators and controls are described below.
PWR (Power)
This LED illuminates when the unit is connected to and receives 24 VDC power
from an external power pack or the Cresnet NET connector.
NET
This LED illuminates when the central processing unit is processing or
com
2-Series Professional Media Controller with RF SIG (RF)
This LED illuminates when there is communication (activity) at the rear panel RF
port with a Crestron wireless transmitter.
Ports
The MC2W rear panel ports are illustrated and described below.
NOTE: Interface connectors for the NET, Infrared-Serial, I/O, and Relay Output
ports are provided with the MC2W.
ANTENNA
This 50 ohm BNC connector attaches to the supplied antenna (or optional CNAN
2-Series Professional Media Controller with RF Crestron MC2W
3. Connect the bare wires of the CNXRMIRD to the appropriate pins on the
3-position connector supplied with the MC2W.
For more information on the CNXRMIRD refer to the latest revision of the
CNXRMIRD Infrared Detector Operations Guide (Doc. 8165).
I/O
I/O
1 2 3 4 G
This connector provides four software programmable analog and digital inputs as well
as digital outputs. Digital outputs offer 250mA
2-Series Professional Media Controller with RF Non-Standard COM Pinouts
PIN
DIRECTION
DESCRIPTION
1*
To MC2W
(RXD-) RS-422 Receive Data (Idles Low)
2
To MC2W
(RXD) RS-232 Received Data
3
From MC2W
(TXD) RS-232 Transmitted Data
4
From MC2W
(TXD+) RS-422 Transmit Data (Idles High)
5
Common
RS-232 and RS-422 Signal Common
6
To MC2W
(RXD+) RS-422 Receive Data (Idles High)
7
From MC2W
(RTS) RS-232 Request To Send
8
To MC2W
(CTS) RS-232 Clear To
2-Series Professional Media Controller with RF Crestron MC2W
NOTE: For laptops and other PCs without a built-in RS-232 port, Crestron
recommends the use of PCMCIA cards, rather than USB-to-serial adapters. If a
USB-to-serial adapter must be used, the following devices have been tested by
Crestron with good results:
Belkin (large model) F5U103
I/O Gear GUC232A
Keyspan USA-19QW
Other models, even from the same manufacturer, may not yield the same results.
N
2-Series Professional Media Controller with RF Memory
The MC2W has 36MB of built-in memory (non-volatile and volatile). The total of
36MB is specified as follows: 4MB flash (non-volatile), 32MB SDRAM (volatile),
and 256KB NVRAM (battery backed up). Flash memory contains the file system
inside the 2-series control engine. Non-volatile memory contains information that is
retained after the loss of electrical power. Volatile memory is lost after
2-Series Professional Media Controller with RF Crestron MC2W
all symbols and/or modules that use NVRAM at the beginning of your program.
When NVRAM (.nvr file) is re-installed, all the values should line up with the
program. If the program is modified, and logic is placed before any symbols using
NVRAM, the previously stored values will not line up and your presets will have to
be re-entered
Volatile (SDRAM)
1. Digital, analog and serial signal values
2. S
2-Series Professional Media Controller with RF Setup
Rack Mounting
NOTE: If rack mounting is not required, rubber feet are provided for shelf placement
or stacking. Apply the feet near the corner edges on the underside of the unit.
WARNING: To prevent bodily injury when mounting or servicing this unit in a
rack, take special precautions to ensure that the system remains stable. The following
guidelines are provided to ensure your safety:
�
2-Series Professional Media Controller with RF Crestron MC2W
4. Repeat procedure (steps 1 through 3) to attach the remaining ear to the
opposite side.
Bussing Strip Installation
The 2-Series integrated control system is supplied with a brass bussing strip to
facilitate commoning (linking) of multiple terminal block connections on the relay
port. One strip is supplied for the 8-position terminal block (four relays).
1. To utilize the bussing strip, determin
2-Series Professional Media Controller with RF Downloads | Product Manuals | Wiring Diagrams section of the Crestron website
(www.crestron.com).
NOTE: Do not power up system until all wiring is verified. Care should be taken to
ensure data (Y, Z) and power (24, G) connections are not crossed.
NOTE: All network wiring must consist of two twisted-pairs. One twisted pair is the
+24V conductor and the GND conductor and the other twisted pair is t
2-Series Professional Media Controller with RF Crestron MC2W
NOTE: To prevent overheating, do not operate this product in an area that exceeds
the environmental temperature range listed in the table of specifications.
Consideration must be given if installed in a closed or multi-unit rack assembly since
the operating ambient temperature of the rack environment may be greater than the
room ambient. Contact with thermal insulating materials should be avoided