MG TR-EVO User Manual Manual
File Specifications
| Brand: | MG |
| Category: | Controller |
| Model: | TR-EVO (User Manual Manual), prT6SJNR7pMK6 |
| File Type: | |
| File Size: | — |
| Pages: | 24 pages |
Download PDF
Download MG TR-EVO Manual (24 pages)Read Online:
Read the MG TR-EVO User Manual Manual online using the built-in PDF viewer.
Key Pages of Document
MG MGINDUSTRY srl Via Casa Celeste 14 36014 Santorso (VI) Italy E-mail [email protected] Draft 2 13/02/2020 EN ...
General Index Editor's notes..............................................................................................................................II Introduction.................................................................................................................................1 Warnings.................................................... ...
without using external sensors. By taking advantage of the voltage-current characteristic, the TR-EVO manages to maintain the temperature set even in conditions of high heath loss, thereby obtaining considerable benefits compared to traditional methods u ...
Power supply: 230Vac with maximum distorsion of 10%. 115Vac option available Mains frequency: 47 Hz to 65 Hz whit automatic adaption to the mains frequency in this range Peak output power: 3600 VA. Continuous output power 1200 VA. 1800VA with ...
standards ISO/EN 61558 -Variable dimensions from mm. 122x95x108 -Variable weight starting from 4.3Kg DIN bar adapter Technical data: -Standard reference DIN EN5002250035 -Front dimensions 112x55mm. -Total depth with mounted device 155mm. -Metal an PVC made. ...
Before you begin: -Ensure correct power supply voltage. -Check an efficient ground system is present Cable passage hole for heating element current detection. Power unit Reserve in the electrical cabinet 110mm on a DIN rail EN 50022- 50035 and insert the unit in it. D ...
Reserve, next to the power unit, 60mm on a DIN rail EN50022- 50035 Connect the supplied cables to the display unit. Insert the display unit into the slot and secure it with the standard panel mounting clips provided. The cables are used for connection to the power unit and the RS485 communication module of the PLC. Wire the system using the ...
Terminals 3, 4 Output to pulse transformer primary. The transformer should be dimensioned starting with the size of the element to control, i.e. the type of alloy, width, thickness and length. (see specific section). Unless legislative indications state otherwise, cables with a 2 ...
"IN WORK" output Opto-isolated output of sealing circuit signaling: this optical coupler is closed during the sealing cycle, and return open at the end of the cycle; see the "operating modes" section for further operating details. It can be externally configured NPN or PNP, with a maximum current which must not exceed 50mA at 24 Volts continu ...
element, connecting at other points introduces measurement errors and reduces the efficiency of temperature control. Current measurement input To sense the heating element current, TR-EVO has a dedicated passage where to pass one of the connecting cabl ...