Crestron CPC-CAMI Operation Manual
Text of Crestron CPC-CAMI Operation Manual
Pan/Tilt Camera Head with Control Interface
Contents
Pan/Tilt Camera Head with Control Interface: CPC-CAMI
1
Description.................................................................................................................................1
Functional Description ................................................................................................1
Physical Description.................................................
Pan/Tilt Camera Head with Control Interface Pan/Tilt Camera Head with
Control Interface: CPC-CAMI
Description
Functional Description
The CPC-CAMI is an integrated pan/tilt head and network control interface
belonging to the Crestron ProCam family of network camera control. The unit has
been designed to provide control of a remotely positioned video camera site. Control
is defined as the two-axis motion of the pan/tilt unit and the focus/
Pan/Tilt Camera Head with Control Interface Crestron CPC-CAMI
Presets
In conjunction with the Crestron control system, the CPC-CAMI is capable of
“memorizing” pan/tilt positions and focus/zoom settings for a virtually unlimited
number of presets. Each preset stores a specific position and setting. Positional
feedback signals are essential to the implementation of presets; unless the lens
supports position mode. These analog signals, provided by the pan
Pan/Tilt Camera Head with Control Interface Adjustable mounting plates (flat and angled) and mounting hardware are provided
with each CPC-CAMI. The two plates can be fixed to one of the rotating disks with
the mounting hardware to provide camera/lens support. The other disk serves as a
mounting platform for the CPC-CAMI with attached camera/lens assembly.
CPC-CAMI Ports
A number of ports are located on the CPC-CAMI interface box. Each has
Pan/Tilt Camera Head with Control Interface Crestron CPC-CAMI
CPC-CAMI Pinout for LENS Port
PIN
DESCRIPTION
1
Focus Out
2
Focus Common
3
Zoom Out
4
Zoom Common
5
Rate/Position Mode
6
5V Reference from Lens
7
7.5V Reference from Lens
8
Iris Out
9
Iris Common
10
Iris Control 1
11
Iris Control 2
12
+5V to Pots
13
Pot Zoom
14
Pot Focus
15
0 Volts to Pots
Wiring Diagram for Lens A, B, and D (+/-12V, +/-8V, and +/-6V)
M
POWER_GND
IRIS_CONTROL_1
IRIS_CONTROL_2
FE
Pan/Tilt Camera Head with Control Interface Wiring Diagram for Lens C (KTS/KTS-A Series and MD/BMD/SD Series)
FOCUS_FEEDBACK
ANALOG_GROUND
IRIS_CONTROL_2
ZOOM_FEEDBACK
IRIS_CONTROL_1
12
n/c
15
n/c
14
n/c
13
n/c
IRIS MODE (LOCAL/CAMERA)
ANALOG_+5V
11
10
POWER_GND
8
9
n/c
IRIS_MOTOR
4
5
IRIS_CONTROL
+5V_VOLTS_LENSE_REFERENCE
7_VOLTS_FROM_LENSE
FOCUS_MOTOR
CPC-CAMI
3
9
FOCUS SPEED/POS SIG
7
6
POWER_GND
RATE/POSITION
5
4
IRIS SPEED/POS SIG
SI
Pan/Tilt Camera Head with Control Interface Crestron CPC-CAMI
CPC-CAMI Indicators
A number of indicators are located on the CPC-CAMI interface box. Each has a silk-
screened label. Refer to the illustration shown in “CPC-CAMI Ports” on page 3 and
the descriptions after this paragraph.
POWER
This LED illuminates when 24 VDC is supplied to the CPC-CAMI.
NET
This LED illuminates when communication between the control system and the
CPC-CAMI is established
Pan/Tilt Camera Head with Control Interface Leading Specifications
The table below provides a summary of leading specifications for the CPC-CAMI.
Dimensions and weights are rounded to the nearest hundredth unit.
Leading Specifications of the CPC-CAMI
SPECIFICATION
DETAILS
Power Requirements
24 VDC, 2.5A; 60 Watts
Default Network ID
34
SIMPL™ Windows®
Version 1.18 or later 1
CNMSX-AV/PRO Upgrade File (.upz)
Version 5.01.35x or later 2
Pan/Tilt Camera Head with Control Interface Crestron CPC-CAMI
Leading Operational Specifications of the CPC-CAMI
SPECIFICATION
DETAILS
Operating Speeds
Pan (horizontal) 22.5 degrees/second
Tilt (vertical) 20.0 degrees/second
Maximum Camera/ Lens Load
15 lbs. (6.80 kg) - (balanced)
Preset Recall Resolution
+/- 0.25 degrees
As of the date of manufacture, the unit has been tested and found to comply with
specifications for CE marking.
NOTE: These devices co
Pan/Tilt Camera Head with Control Interface Determining Camera/Lens Assembly Center of Gravity
ROUND OBJECT
1/4-20 MOUNTING
SCREW
FLAT MOUNTING PLATE
CAMERA
LENS
5. Use two 1/4-20 x 3/8” pan Phillips head screws (supplied) to loosely
secure the angled mounting plate to the CPC-CAMI. Verify that the
two pins on the plate align with the slot on the rotating disk.
6. Adjust the vertical position of the angled mounting plate (refer to the
i
Pan/Tilt Camera Head with Control Interface Crestron CPC-CAMI
10. Mount the CPC-CAMI with attached camera/lens assembly to the
desired location. Unit mounts on its 3.750 inch (9.525 cm) diameter
base with two ¼-20x3/8” pan Philips head screws, 2.000 inches (5.080
cm) on center (refer to the illustration below).
NOTE: If longer screws (than the ones supplied) are required to mount the CPC-
CAMI with attached camera/lens assembly, only allow five turns i
Pan/Tilt Camera Head with Control Interface 8. To verify this procedure, select Diagnostics | Report Network
Devices. Confirm that the CPC-CAMI has a new NET ID code.
9. Reconnect other network or modular devices that were disconnected in
step 1.
Preparation for Use
Refer to the hookup diagram below. Other than connecting the correct jumper board
first and making the power connection last, complete the connections in any order.
NOTE: Bef
Pan/Tilt Camera Head with Control Interface Crestron CPC-CAMI
Limit Stop Adjustment
Two locking screws are found on each rotating disk on the CPC-CAMI. Complete
the following steps to properly set the limit stops.
1. Loosen both pan (horizontal drive) and tilt (vertical drive) locking
screws.
2. Slowly rotate the camera/lens assembly to the desired left-pan limit.
3. Slide a loosened locking screw until it engages the pan sensor; tighten
the locking screw.
Pan/Tilt Camera Head with Control Interface Maintenance
NOTE: Do not attempt to open the unit to make any adjustments or repairs. In the
event that an operating problem occurs, contact a member of Crestron’s technical
support team. Refer to “Further Inquiries” on page 17.
The CPC-CAMI has been designed to eliminate the need for periodic maintenance.
Lubrication for all moving parts is permanent. Motors, switches, and other moving
Pan/Tilt Camera Head with Control Interface Crestron CPC-CAMI
NOTE: There is no need to recreate this sample SIMPL Windows program. The
program is available from the Crestron ControlCD (version 6.2 and later) or the
Downloads page (EXAMPLES Library) of the Crestron website
(www.crestron.com). Search for CPC-CAMI.SMW.
Jumper Board A, B, or D
For most "standard" lenses using CPC-CAMI jumper board A, B or D, programming
is essentially the same. A sample SIMP
Pan/Tilt Camera Head with Control Interface Jumper Board C
Servo drive lenses requiring jumper board C (such as the Canon KTS and Fujinon
MD, BMD series), do not have true feedback pots. Instead they have separate rate
and position control modes. If presets are not required, the CNCAMI RATE
CONTROL module can be used for direct drive of the rate lines on the CPC-CAMI
definition.
Since these lenses do not have true preset pots, programmin
Pan/Tilt Camera Head with Control Interface Crestron CPC-CAMI
Positional Feedback Signals
Positional feedback signals are generated by the networked CPC-CAMI and input to
the rest of the program. Four analog positional feedback signals, TILT_POS,
PAN_POS, FOC_POS, and ZOOM_POS, represent the current pan/tilt axis position
and focus/zoom lens setting. The CPC-CAMI converts positional potentiometer
wiper voltages to analog positional feedback signals. For ex
Pan/Tilt Camera Head with Control Interface Problem Solving
Troubleshooting
The table that follows this paragraph provides corrective action for possible trouble
situations. If further assistance is required, please contact a Crestron technical
support representative; refer to “Further Inquiries” on page 17.
CPC-CAMI Troubleshooting
TROUBLE
POSSIBLE CAUSE(S)
CORRECTIVE ACTION
CPC-CAMI does not
function. POWER LED
is not illuminated.
C