dkc3127a0600p_01 - 3/20

CONTENTS 1. INTRODUCTION .................................................................................................................................................................................................................................................................... 4 2. ORDER CODES ..................................................................................................................................................................................................................................................................... 5 2.1 DK-300 ORDER CODE ............................................... ...

dkc3127a0600p_01 - 4/20

Thank you for choosing NIVELCO instrument. We are sure that you will be satisfied throughout its use! 1. INTRODUCTION The NIPRESS DK-300 series is an electronic pressure switch with stainless steel internal or flush sensor. This device is a 2- or 3-wire mini compact pressure switch with rotatable LCD display for absolute and gauge pressure. It can be ordered with 1 – 4 PNP transistor, 4 – 20 mA or 0 – 10 V output, available in a wide range of measurement ranges within the -1 – 0 bar and 0 – 600 bar. The DK-400 series is an electronic pressure switch with welded stainless steel flush sensor. This makes it suitable for n ...

dkc3127a0600p_01 - 5/20

2. ORDER CODES 2.1 DK-300 ORDER CODE (NOT ALL COMBINATIONS POSSIBLE!) NIPRESS D K – 3 – MEASURING MODE CODE PROCESS CONNECTION CODE RANGE / OVERLOAD CAPABILITY [bar] CODE ACCURACY CODE OUTPUT / EX CODE Switch K 1/4" BSP A -1 – 0 / 5 0 0.25%(2) 1 1 PNP switching output 7 1/2" BSP C 0 – 0.1 / 0.5 1 0.5% 2 2 PNP switching output 9 3/4" BSP(1) D 0 – 0.16 / 1 R 4 PNP switching output (3) E 1/4" NPT G 0 – 0.25 / 1 2 4 – 20 mA 2-wire, 1 PNP switching output / Ex ia F 1/2" NPT H 0 – 0.4 / 2 3 0 – 0.6 / 5 4 0 – 1 / 5 5 (1) flush membrane (max. 40 bar) 0 – 1.6 / 10 6 (2) p ≥ 0.4 ...

dkc3127a0600p_01 - 6/20

2.2 DK-400 ORDER CODE (NOT ALL COMBINATIONS POSSIBLE!) NIPRESS D – 4 – MEASURING MODE CODE PROCESS CONNNECTION CODE RANGE / OVERLOAD CAPABILITY [bar] CODE ACCURACY CODE OUTPUT / EX CODE Switch up to +125 °C K 1/2" BSP(2) C -1 – 0 / 5 0 0.25%(6) 1 1 PNP switching output 7 Switch up to +300 °C(1) L 3/4" BSP D 0 – 0.1 / 0.5 1 0.5% 2 2 PNP switching output 9 1" BSP E 0 – 0.16 / 1 R 4 PNP switching output (7) E 3/4" TriClamp T 0 – 0.25 / 1 2 4 – 20 mA 2-wire, 1 PNP F 1" TriClamp L 0 – 0.4 / 2 3 switching output / Ex ia 1 1/2" TriClamp M 0 – 0.6 / 5 4 2" TriClamp N 0 – 1 / 5 5 DN25 DIN11851(3) O 0 � ...

dkc3127a0600p_01 - 7/20

2.3 DK-800 ORDER CODE (NOT ALL COMBINATIONS POSSIBLE!) NIPRESS D K – 8 2 – MEASURING MODE CODE PROCESS CONNNECTION CODE RANGE / OVERLOAD CAPABILITY [bar] CODE ACCURACY COD E OUTPUT / EX CODE Switch K 1/4" BSP A -1 – 0 / 4 0 0.5% 2 1 PNP switching output 7 1/2" BSP C 0 – 0.4 / 1 3 2 PNP switching output 9 3/4" BSP(1) D 0 – 0.6 / 2 4 4 PNP switching output (2) E 1/4" NPT G 0 – 1 / 2 5 4 – 20 mA 2-wire, 1 PNP switching output / Ex ia F 1/2" NPT H 0 – 1.6 / 4 6 (1) 0.6 ≤ PN ≤ 60 bar 0 – 2.5 / 4 7 (2) Only with 3-wire analogue output and with M12x1 (8 pin) 0 – 4 / 10 8 electric co ...

dkc3127a0600p_01 - 8/20

3. TECHNICAL DATA Type DK-3- DK-4-, DL-4- DK-82- Measurement range -1 – 0 bar; 0 – 600 bar (-14.5 – 0 psig; 0 – 8700 psig) according to the order code -1 – 0 bar; 0 – 40 bar (-14.5 – 0 psig; 0 – 580 psig) according to the order code -1 – 0 bar; 0 – 600 bar (-14.5 – 0 psig; 0 – 8700 psig) according to the order code Overload capability According to the order code Accuracy 0.5% Optional: 0.25% (p ≥ 0.4 bar [5.8 psig]) 0.5% Medium temperature -40 °C … +125 °C (-40 °F … +257 °F) -40 °C … +125 °C (-40 °F … +257 °F) silicone oil; (1) -10 °C … +12 ...

dkc3127a0600p_01 - 9/20

Permissible medium temperature for DK-400 with cooling element (max. +300 °C [572 °F]): - Silicone oil fill fluid: in case of overpressure: -40 °C…+300 °C (-40 °F…+572 °F) in vacuum (also for PABS ≤ 1 bar): -40 °C…+150 °C (-40 °F…+302 °F) - Food grade oil fill fluid: in case of overpressure: -10 °C…+250 °C (+14 °F…+482 °F) in vacuum: -10 °C … +150 °C (+14 °F…+302 °F) SPECIAL DATA FOR EX CERTIFIED MODELS (ONLY FOR 4 – 20 mA / 2-WIRE) ATEX Approval, Ex ia: Type DK-300 DK-400, DL-400 DK-800 Ex marking (Pending) Power supply USupply = 15 – 28 V DC Intrinsically safe data Use only with Ex ia ce ...

dkc3127a0600p_01 - 10/20

3.2 DIMENSIONS (DK-400, DL-400) DKC-4- (P ≥ 1 bar) 1/2" BSP DKD-4- 3/4" BSP DKE-4- 1" BSP DKT-4- / DKL-4- / DKM-4- / DKN-4- TRICLAMP – 3/4", 1", 1 1/2", 2" DKO-4- / DKP-4- / DKR-4- DIN11851 hygienic connections DKV-4- VARIVENT, PN ≤ 25 bar DL-4- COOLING ELEMENT (+300 °C / 572 °F) Size ¾” 1” 1 ½” 2” Size DN 25 DN 40 DN 50 3.3 ACCESSORIES - Installation and programming manual - Warranty card - EU declaration of conformity A [mm] 14 23 32 45 A [mm] 23 32 45 B [mm] 25 50.5 50.5 64 B [mm] 44 56 68,5 PN [ba ...

dkc3127a0600p_01 - 11/20

3.4 SPECIAL CONDITIONS OF SAFE USE Before turning on the device, make sure the installation is complete, and there are no visible defects. The device may only be used within the limitations specified in the technical specifications. Protection against electrostatic charge: The devices may partially contain static charging capable plastic components. The presence of electrostatic charges may cause a risk of spark generation and ignition and therefore electrostatic charges must be completely prevented: - Use a shielded cable! - Avoid friction on plastic surfaces! - Do not clean the device dry! For example, use a wet duster! Ex ia ...

dkc3127a0600p_01 - 12/20

4.2 WIRING Shielded and twisted multicore cable is recommended for the electrical connection. For devices with cable gland as well as cable socket, you have to make sure that the external diameter of the used cable is within the allowed clamping range. After you have connected the wires, tighten the gland screw firmly until proper sealing. For the installation of a device with cable outlet following bending radiuses have to be complied with: Cable without ventilation tube: - static installation: 5-fold cable diameter - dynamic application: 10-fold cable diameter Cable with ventilation tube: - static installation: 10-fold cable ...

dkc3127a0600p_01 - 13/20

(1) Different cable types and lengths available, the permissible temperature depends on kind of cable; standard: 2 m PVC cable (without ventilation tube, permissible temperature: -5 °C ... +70 °C [-23 °F ... +158 °F]) Supply + 1 1 1 white Supply – 3 2 3 brown 3-wire: Signal + (only in 3-wire) 2 3 2 green Contact 1 4 3 4 grey Contact 2 5 - 5 pink Contact 3 - - 6 blue Contact 4 - - 7 red Shield plug housing / pressure port ground connection pin via pressure port green-yellow ...

dkc3127a0600p_01 - 14/20

4.3 EXAMPLES OF ARRANGEMENTS PRESSURE SWITCH (1-2 SWITCHING OUTPUTS) WIRING OF 3-WIRE PRESSURE SWITCH WITH TRANSMITTER OUTPUT WIRING OF 2-WIRE EX ia PRESSURE SWITCH WITH TRANSMITTER OUTPUT 5. PROGRAMMING 5.1 OPERATING INFORMATION 5.2 CONFIGURATION The device has, according to the order, max. four LEDs which are allocated to the respective contacts. The LEDs will light up when the respective set point has been reached and the contact is active. Regardless of the number of PNP switches, the structure of the menu system is the same for all types of devices. They differ only by the number of menu items. Following the chart (5.6) an ...

dkc3127a0600p_01 - 15/20

5.3 PASSWORD SYSTEM Your device's menu system can be protected by a password, so it is only possible for an authorized person to make settings. If you activate password access ("PAon"), the entire menu system will be closed. For more information, see "5.7 Detailed menu items". Entering the password will make the entire menu available again, then allow you to change the password at the special menu item 4. In case you forget your password, you can restore the instrument to the factory settings. To do this, use the special menu item 3. 5.4 CONFIGURATION EXAMPLE OF THE ANALOGUE OUTPUT (FOR 4 – 20 mA / 3-WIRE ADJUSTABLE) By the m ...

dkc3127a0600p_01 - 16/20

5.6 STRUCTURE OF THE MENUSYSTEM STRUCTURE OF THE STANDARD 2- AND 3-WIRE AND THE 4 – 20 mA / 2-WIRE EX ia SYSTEM ...

dkc3127a0600p_01 - 18/20

5.7 DESCRIPTION OF THE MENUSYSTEM Menu 1 – Access protection PAon  password active  to deactivate: set password. PAof  password inactive  to activate: set password. The default setting for the password is "0005"; modification of the password is described in "Special menu 4". Menu 2 – Set decimal point position For devices with 3-wire output 4 – 20 mA and 0 – 20 mA the decimal point was already set during production. Menu 2a – Indication of the start of measuring range (only 4 – 20 mA / 3-wire adjustable) Value defined at order, no input option. Menu 2b – Indication of end of measuring range (only 4 – ...

dkc3127a0600p_01 - 19/20

Menu 35 – Error signal definition (only 4 – 20 mA / 3-wire adjustable) Set the desired error signal (this is given out in case of a defect). Permissible options: "0FF" (no error signal), "C 0" (0 mA or 0 V), "C L0" (3.5 mA or 1.75 V) and "C HI" (23 mA or 11.5 V). The error message appears only when Menu 6 "HILo" is set to "on". Menu 36 – Offset compensation / position correction (only 4 – 20 mA / 3-wire adjustable) Enter the POSI menu; if offset ≠ ambient pressure it is necessary to place the device under pressure pended on mounting position (the pressure reference has to correspond to the zero point of the pressure ...

dkc3127a0600p_01 - 20/20

6. TROUBLESHOOTING Fault Possible causes Fault detection / remedy No output signal: Connected incorrectly. Check the connections! Conductor/wire breakage. Check all wires with cable tester! Defective measuring device (signal input). Check the ampere meter (and its fuse) and the analogue input of the signal processing unit! Analog output signal too low: Load resistance too high. Check the value of the load resistance! Supply voltage too low. Check the power supply and power / current on the transducer / transmitter! Slight shift of the output signal: The diaphragm of the sensor is severely contaminated. Cleaning with non-aggress ...

Switch PDF Instructions

HP ProCurve 2510G-48 Specifications
HP ProCurve 2510G-48
05.05.2026 2 pages

♦ For as long as you own the product, with next-business-day advance replacement (available in most countries). The following hardware products and their related family modules have a one-year warranty with extensions available: The ProCurve Routing Switch

HP StorageWorks 2/64 - Core Switch Administrator's manual
HP StorageWorks 2/64 - Core Switch
29.04.2026 74 pages

HP StorageWorks Fabric OS 5.x Fabric Watch administrator guide Part number: AA-RVJ0B-TE Second edition: September 2005

Tripp Lite U359-002 Owner's manual
Tripp Lite U359-002
18.07.2026 4 pages

1 Owner’s Manual Este manual esta disponible en español en la página de Tripp Lite: www.tripplite.com/support Ce manuel est disponible en français sur le site Web de Tripp Lite : www.tripplite.com/support Русскоязычная версия насто

D-Link DES-3226L Reference manual
D-Link DES-3226L
30.05.2026 228 pages

i 0. DES-3226L Layer 2 Switch Command Line Interface Reference Manual First Edition (September 2003) 651S3226L015 Printed In China RECYCLABLE