MEDC HORN DB3 Technical Manual

Text of the manual

© Cooper MEDC 2011

08/11 Technical Manual for the Sounders DB3 & DB3L Technische Anleitung für die Schallgeber DB3 & DB3L Manuel Technique - Avertisseur Sonores DB3 et DB3L Manual Técnico dos sinalizadores sonoros DB3 e DB3L Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibilit

This range of light weight all GRP, flameproof sounders is intended for use in potentially explosive gas and

dust atmospheres and has been designed with high ingress protection to cope with the harsh environmental conditions found offshore and onshore in the oil, gas and petrochemical industries. The flamepaths, flare and body are manufactur

The unit is available in six basic configurations:

1. Exd - DC Input, single tone 2. Exde - DC input, single tone 3. Exd - DC input, dual tone 4. Exde - DC input, dual tone 5. Exd - AC input, single tone 6. Exde - AC input, single tone Types 1 & 2 have 6 terminals labelled as T1 to T6. The supply should be connected to T1 (+ve), T3 (-ve), loop

For all versions, a 5-way DIL switch selects the tone required. The settings for the standard tones are shown

in table 1 below: Table 1 TONE No. TONE FREQ/DESCRIPTION SWITCH SETTING 12345 TONE DESCRIPTION Nominal SPL (dB(A) @ 1M) 1 Alt Tones 800/970 Hz at 1/4 sec 11111 114 2 Sweeping 800/970 Hz at 7 Hz 11110 Fast Sweep (LF) 114 3 Sweeping 800/970 Hz at

During the working life of the unit, it should require little or no maintenance. GRP will resist attack by most

acids, alkalis and chemicals and is as resistant to concentrated acids and alkalis as most metal products. However, if abnormal or unusual environmental conditions occur due to plant damage or accident etc., then visual inspection i

Certified to IEC 60079-0, IEC 60079-

- Ex d IIC unit (IEC certification No. IECEx BAS 11.0083X) Ex d IIC TG (Tamb.) Gb Ex tb IIIC TD (Tamb.) Db IP6X Ex de IIC unit (IEC certification No. IECEx BAS 11.0084X) Ex de IIC TG (Tamb.) Gb Ex tb IIIC TD (Tamb.) Db IP6X The IECEx certificate and product label carry the IECEx equ

6.0 SPECIAL CONDITIONS FOR SAFE USE

a) Type DB3/DB3L - IECEx BAS 11.0083X & BAS00ATEX2097X (Exd) 1. This apparatus is not suitable for use in atmospheres containing carbon disulphide 2. This apparatus is suitable for use only in ambient temperatures as follows: Type Max. Power rating Tamb. TG TD 15W -20°C to +55°C T5 T100°C DB3 15W -20°C to +70°C T4 T13