Crown CDi 6000 Operation Manual

Text of Crown CDi 6000 Operation Manual

Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact

your local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000. This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may arise during installation, operation or maintenance. The

CDi Series Power Amplifiers

Operation Manual 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat reg­isters, stoves, or other apparatus (including amplifiers
CDi Series Power Amplifiers Operation Manual page 3 DECLARATION of CONFORMITY European Representative’s Name and Address: David Budge 10 Harvest Close Yateley GU46 6YS United Kingdom Equipment Type: Power Amplifiers Family Name: CDi series Model Names: CDi1000, CDi2000, CDi4000, CDi6000 EMC Standards: EN 55103-1:2009 EMC Compatibility – Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professi
CDi Series Power Amplifiers Operation Manual Table of Contents Important Safety Instructions...........................2 Declaration of Conformity................................3 1 Welcome...................................................5 1.1 Features.............................................5 1.2 How to Use This Manual......................5 2 Setup.........................................................6 2.1 Unpack Your A
CDi Series Power Amplifiers Operation Manual page 5 1 Welcome The CDi Series of Crown® amplifiers are professional tools designed and built for installed sound applications. The series includes three models which are identical except for output power: CDi 1000, CDi 2000, CDi 4000 and CDi 6000. All are rugged and lightweight, and offer unmatched value in their class. CDi-Series amplifiers feature an intuitive front-panel LCD screen to guide installers thro
CDi Series Power Amplifiers Operation Manual 2 Setup 2.1 Unpack Your Amplifier Please unpack and inspect your amplifier for any damage that may have occurred during transit. If damage is found, notify the transpor­tation company immediately. Only you can ini­tiate a claim for shipping damage. Crown will be happy to help as needed. Save the shipping carton as evidence of damage for the shipper’s inspection. We also recommend that you save all pa
CDi Series Power Amplifiers Operation Manual page 7 Figure 2.3 Input Connector Phoenix Wiring, Bal­anced (Top) and Unbalanced (Bottom) 2.4 Choose Input Wire and Connectors Crown recommends using pre-built or professionally wired balanced line (two-conductor plus shield), 22-24 gauge cables and connectors. At the amplifier inputs, use Phoe­nix-style connectors (see Figure 2.3). Unbalanced lines may be used, but may result in hum or RF noise over long cab
CDi Series Power Amplifiers Operation Manual Channel 2 Channel 2 Channel 1 Channel 1 Figure 2.5 System Wiring, Dual Mode 2 Setup (continued) 2.6 Wire Your System 2.6.1 Dual Mode Typical input and output wiring is shown in Figure 2.5. INPUTS: Connect input wiring for both channels. OUTPUTS: Maintain proper polarity (+/–) on output connectors. Connect Channel 1 loudspeaker’s positive (+) lead to Channel 1 positive (+) terminal of amp; repeat for
CDi Series Power Amplifiers Operation Manual page 9 2 Setup (continued) Channel 1 2.6.2 Bridge-Mono Mode Typical input and output wiring is shown in Figure 2.6. NOTE: Crown provides a reference of wiring pin assignments for commonly used connector types in the Crown Amplifier Application Guide available at www.crownaudio.com. OUTPUTS: Connect the speaker across barrier-strip terminals 1+ and 2+. IMPORTANT: Set the Bridge/Normal switch in the LCD screen to
CDi Series Power Amplifiers Operation Manual 2 Setup (continued) 2.7 Connect to AC Mains Connect your amplifier to the AC mains power source (power outlet) with the supplied AC power cordset. First, connect the IEC end of the cordset to the IEC connector on the amplifier; then, plug the other end of the cordset to the AC mains. WARNING: The third prong of this connector (ground) is an important safety feature. Do not attempt to disable this ground
CDi Series Power Amplifiers Operation Manual page 11 3.1 Precautions Your amplifier is protected from internal and external faults, but you should still take the following precau­tions for optimum performance and safety: 1. Before use, your amplifier first must be config­ured for proper operation, including input and output wiring hookup. Improper wiring can result in serious operating difficulties. For information on wiring and configuration, please con
CDi Series Power Amplifiers Operation Manual 3 Operation (continued) J. AC Line Connector NEMA 5-15P (15A). K. Output Connectors 4-position barrier strip with connectors for dual loudspeakers or bridge-mono loudspeaker. Dual connectors work with 2-8 ohm or 70V loads. Bridge-mono connectors work with 4-8 ohm or 140V loads. L. Fan Front-to-rear forced airflow. M. Input Connector Two 3-pin removable Phoenix-type connectors each accept a balanced line-
CDi Series Power Amplifiers Operation Manual page 13 3 Operation (continued) M N O P J K L J. Line Connector Clip Mounting points for securing power cord clip. K. AC Line Connector NEMA 6-20P (20A). L. Reset Button Resets the circuit breaker. M. Output Connectors 4-position barrier strip with connectors for dual loudspeakers or bridge-mono loudspeaker. Dual connectors work with 2-8 ohm or 70V loads. Bridge-mono connectors work with 4-8 ohm or 140V loads. N
CDi Series Power Amplifiers Operation Manual 4 Advanced Features and Options Figure 4.1 DC Protection NOTE: For detailed information about these Crown amplifier features, please consult the Crown Amplifier Application Guide, available on the Crown website at www.crownaudio.com. 4.1 Protection Systems Your Crown amplifier provides extensive protection and diagnostic capabilities, including output current limiting, microprocessor-controlled DC protec
CDi Series Power Amplifiers Operation Manual page 15 4 Advanced Features and Options (continued) Figure 4.5 LCD Screen and Menu Navigation Buttons Figure 4.6 Menu Tree ICONS PRESET NAME OR DSP SETTING Without correction, the Thermal Protection circuit will typically reactivate. 4.1.6 DSP Presets and Processes OVERVIEW Figure 4.5 shows the LCD screen and the three Menu navigation buttons: Sel/Enter, Prev/Up and Next/Down. These buttons let you step through
CDi Series Power Amplifiers Operation Manual CURRENT PRESET FLASHING “PRESET” TEXT FLASHING “PRESET” ICON Sel Sel Sel Next USER PRESETS 2-20 DSP OFF Next Next Next or Prev FLASHING “CONFIG” TEXT Y XOV EQ Ch. 1 EQ Ch. 2 DELAY Ch. 1 DELAY Ch. 2 LIM Ch. 1 LIM Ch. 2 STEREO/BRIDGE MONO BRIDGE STEREO Sel Sel Sel Sel Sel Sel Sel Sel Next Prev Next Next Next Next Next Next OFF, 90 Hz, 100 Hz, 1200 Hz, 1500 Hz, 2000 Hz, 2-CH SUB, CUSTOM

Crown Amplifier Owners Instructions: