Crown CT-1610 Service Manual
Text of Crown CT-1610 Service Manual
Com-Tech 810 and 1610 Amplifier Service Manual
]
Rev. 0
KSVCCT810/1610
8/98
Commercial Audio
E106377
®
120 VAC North
American Units:
© 1998 by Crown International, Inc., P.O. Box 1000, Elkhart, Indiana 46515-1000 U.S.A. Telephone:
219-294-8000. Com-Tech amplifiers are produced by the Professional Audio Division of Crown
International, Inc. Trademark Notice: SmartAmp™ and Grounded Bridge™ are trademarks and Amcron,®
Crown,® Com-Tech,® IOC,® ODEP,�
Com-Tech 810 and 1610 Amplifier Service Manual ]
Rev. 0
À PRÉVENIR LE CHOC
ÉLECTRIQUE N’ENLEVEZ
PAS LES COUVERTURES.
RIEN DES PARTIES
UTILES À L’INTÉRIEUR.
DÉBRANCHER LA BORNE
AVANT D’OUVRIR LA
MODULE EN ARRIÈRE.
TO PREVENT ELECTRIC SHOCK DO
NOT REMOVE TOP OR BOTTOM
COVERS. NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE
PERSONNEL. DISCONNECT
POWER CORD BEFORE REMOVING
REAR INPUT MODULE TO ACCESS
GAIN SWITCH.
CAUTION
Com-Tech 810 and 1610 Amplifier Service Manual ]
Rev. 0
Table of Contents
1 Introduction .............................................................................. 1-1
1.1 The Com-Tech Series....................................................... 1-1
1.2 Warranty ........................................................................... 1-1
2 Specifications .......................................................................... 2-1
2.1 Performance.
Com-Tech 810 and 1610 Amplifier Service Manual ]
Rev. 0
5.6 Dual Operation................................................................. 5-6
5.7 Bridge-Mono Operation ................................................... 5-6
5.8 Parallel-Mono Operation .................................................. 5-6
6 Electrical Checkout Procedures .............................................. 6-1
6.1 General Information............................................
Com-Tech 810 and 1610 Amplifier Service Manual ]
1-1
Rev. 0
Crown International, Inc.
Mailing: PO Box 1000
Elkhart, IN 46515-1000
or
Shipping: Plant 2 S.W.
1718 W. Mishawaka Rd.
Elkhart, IN 46517
Toll Free: (800) 342-6939
Phone: (219) 294-8200
FAX: (219) 294-8301
Web: www.crownaudio.com
This manual contains service information for the Crown
Com-Tech–10 Series power amplifiers. It is designed
to be used in conjunction with the Com-Tech Refer-
ence Manual.
Com-Tech 810 and 1610 Amplifier Service Manual ]
2-1
Rev. 0
The following specifications apply to all models in Dual mode
with 8-ohm loads and an input sensitivity of 26 dB unless
otherwise specified.
MAP at 1 kHz: This term refers to maximum average power in
watts at 1 kHz with 0.1% THD.
Full Bandwidth Power: This term refers to maximum average
power in watts from 20 Hz to 20 kHz with 0.1% THD.
120 VAC, 60 Hz Units: These North American units have dedi-
c
Com-Tech 810 and 1610 Amplifier Service Manual ]
2-2
Rev. 0
2.4 Indicators
Enable: This amber indicator shows the on/off status of the
unit's low-voltage power supply and the activation of the
energy-saving mode.
SPI (Signal Presence Indicator): Each channel has a green
indicator that flashes to show audio output.
IOC (Input/Output Comparator): Each channel has a yellow
indicator that flashes if the output waveform differs from the
input waveform by 0.05%
Com-Tech 810 and 1610 Amplifier Service Manual ]
2-3
Rev. 0
Height B:
5.25 inches (13.3 cm)
Models:
Com-Tech 410 (100/120 VAC, 50/60 Hz)
Com-Tech 410 (220/240 VAC, 50/60 Hz)
Com-Tech 810 (All)
Height C:
7 inches (17.8 cm)
Model:
Com-Tech 1610 (All)
Approximate Weight: Center of gravity is 6 inches (15.2
cm) behind the front mounting surface.
120 VAC, 60 Hz North American Units:
Com-Tech 810: 47 pounds, 4 ounces
(21.5 kg) net; 50 pounds, 8 ounces
(22.9 kg
Com-Tech 810 and 1610 Amplifier Service Manual ]
2-4
Rev. 0
10
100
1 K
10 K
100 K
FREQUENCY (Hz)
+2
+1
0
–1
–2
–3
–4
dB
–5
–6
–7
4 ohm
8 ohm
1 watt
504.0
126.8
31.8
MILLIOHMS
8.0
2.0
6 dB
20
100
1 K
10 K
20 K
400
200
100
0
600
800
1000
1200
1400
FREQUENCY (Hz)
8 ohm
10
100
1 K
10 K
100 K
FREQUENCY (Hz)
Figure 2.1 Typical Frequency Response
Figure 2.2 Typical Damping Factor
Figure 2.3 Typical Output Impedance
Com-Tech 810 and 1610 Amplifier Service Manual ]
2-5
Rev. 0
Figure 2.4 Typical Phase Response
Figure 2.5 Typical Crosstalk
TEF ®
Measurement
100
1 K
10 K
20 K
FREQUENCY (Hz)
dB
TECHRON TEF ®
TECHRON TEF ®
+45˚
0˚
–45˚
100
1 K
10 K
20 K
FREQUENCY (Hz)
TEF ®
Measurement
Com-Tech 810 and 1610 Amplifier Service Manual ]
2-6
Rev. 0
Crown specifications are guaranteed for three years.
In an effort to provide you with as much information as possible about the high power-producing capabilities of your amplifier, we have
created the following power matrices.
Minimum Guaranteed Power Specifications
Crown’s minimum power specifications represent the absolute smallest amount of output power you can expect from your amplifier when
Com-Tech 810 and 1610 Amplifier Service Manual ]
2-7
Rev. 0
Figure 2.7 Com-Tech 1610 Minimum Power Matrix
Com-Tech 1610 – Minimum Guaranteed Power (Watts)
Dual/Mono
Mode
Dual
(both channels
driven)
Bridge-Mono
(balanced output)
Parallel-Mono
FTC Continuous Average
At 0.1% THD
(See note 4)
1 kHz
20Hz-20kHz
Maximum Average
Load in Ohms
(Constant Voltage)
AC Mains
120 VAC, 60 Hz
1 kHz
At 0.1% THD
(See note 1)
At 0.1% THD
(See note 2)
20Hz-20kHz
Dual
(both
Com-Tech 810 and 1610 Amplifier Service Manual ]
2-8
Rev. 0
Maximum Power Specifications
Crown’s maximum power specifications represent the largest amount of output power you can expect from your amplifier
when it is driven to full output under the given conditions. These specifications can be used to prevent loudspeaker and
hearing damage.
The maximum power matrices include specifications for single cycle and 40-millisecond burst sine waves. Burst signa
Com-Tech 810 and 1610 Amplifier Service Manual ]
2-9
Rev. 0
Figure 2.9 Com-Tech 1610 Maximum Power Matrix
6.25 (70V)
4
Dual
(both channels
driven)
Bridge-Mono
(balanced output)
Parallel-Mono
2
12.5 (140V)
8
3.13 (70V)
8
4
16
Dual
(both channels
driven)
Bridge-Mono
(balanced output)
Parallel-Mono
Com-Tech 1610 – Maximum Power (Watts)
Dual/Mono
Mode
40 Millisecond Tone Burst
At 0.05% THD
(See note 2)
Single Cycle Tone Burst
At less than 0.05% THD
(See not
Com-Tech 810 and 1610 Amplifier Service Manual ]
3-1
Rev. 0
3 AC Power Draw and
Thermal Dissipation
“Soft-Star
“Soft-Star
“Soft-Star
“Soft-Star
“Soft-Start”t”t”t”t” inrush current limiting protects the house
circuit breaker when several amps are turned on simul-
taneously.
This section provides detailed information about the
amount of power and current drawn from the AC mains
by the Com-Tech amplifiers and the amount of heat pro-
duc