Crown CT-1610 Service Manual

Text of Crown CT-1610 Service Manual

Com-Tech 810 and 1610 Amplifier Service Manual

] Rev. 0 KSVCCT810/1610 8/98 Commercial Audio E106377 ® 120 VAC North American Units: © 1998 by Crown International, Inc., P.O. Box 1000, Elkhart, Indiana 46515-1000 U.S.A. Telephone: 219-294-8000. Com-Tech amplifiers are produced by the Professional Audio Division of Crown International, Inc. Trademark Notice: SmartAmp™ and Grounded Bridge™ are trademarks and Amcron,® Crown,® Com-Tech,® IOC,® ODEP,�
Com-Tech 810 and 1610 Amplifier Service Manual ] Rev. 0 À PRÉVENIR LE CHOC ÉLECTRIQUE N’ENLEVEZ PAS LES COUVERTURES. RIEN DES PARTIES UTILES À L’INTÉRIEUR. DÉBRANCHER LA BORNE AVANT D’OUVRIR LA MODULE EN ARRIÈRE. TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. DISCONNECT POWER CORD BEFORE REMOVING REAR INPUT MODULE TO ACCESS GAIN SWITCH. CAUTION
Com-Tech 810 and 1610 Amplifier Service Manual ] Rev. 0 Table of Contents 1 Introduction .............................................................................. 1-1 1.1 The Com-Tech Series....................................................... 1-1 1.2 Warranty ........................................................................... 1-1 2 Specifications .......................................................................... 2-1 2.1 Performance.
Com-Tech 810 and 1610 Amplifier Service Manual ] Rev. 0 5.6 Dual Operation................................................................. 5-6 5.7 Bridge-Mono Operation ................................................... 5-6 5.8 Parallel-Mono Operation .................................................. 5-6 6 Electrical Checkout Procedures .............................................. 6-1 6.1 General Information............................................
Com-Tech 810 and 1610 Amplifier Service Manual ] 1-1 Rev. 0 Crown International, Inc. Mailing: PO Box 1000 Elkhart, IN 46515-1000 or Shipping: Plant 2 S.W. 1718 W. Mishawaka Rd. Elkhart, IN 46517 Toll Free: (800) 342-6939 Phone: (219) 294-8200 FAX: (219) 294-8301 Web: www.crownaudio.com This manual contains service information for the Crown Com-Tech–10 Series power amplifiers. It is designed to be used in conjunction with the Com-Tech Refer- ence Manual.
Com-Tech 810 and 1610 Amplifier Service Manual ] 2-1 Rev. 0 The following specifications apply to all models in Dual mode with 8-ohm loads and an input sensitivity of 26 dB unless otherwise specified. MAP at 1 kHz: This term refers to maximum average power in watts at 1 kHz with 0.1% THD. Full Bandwidth Power: This term refers to maximum average power in watts from 20 Hz to 20 kHz with 0.1% THD. 120 VAC, 60 Hz Units: These North American units have dedi- c
Com-Tech 810 and 1610 Amplifier Service Manual ] 2-2 Rev. 0 2.4 Indicators Enable: This amber indicator shows the on/off status of the unit's low-voltage power supply and the activation of the energy-saving mode. SPI (Signal Presence Indicator): Each channel has a green indicator that flashes to show audio output. IOC (Input/Output Comparator): Each channel has a yellow indicator that flashes if the output waveform differs from the input waveform by 0.05%
Com-Tech 810 and 1610 Amplifier Service Manual ] 2-3 Rev. 0 Height B: 5.25 inches (13.3 cm) Models: Com-Tech 410 (100/120 VAC, 50/60 Hz) Com-Tech 410 (220/240 VAC, 50/60 Hz) Com-Tech 810 (All) Height C: 7 inches (17.8 cm) Model: Com-Tech 1610 (All) Approximate Weight: Center of gravity is 6 inches (15.2 cm) behind the front mounting surface. 120 VAC, 60 Hz North American Units: Com-Tech 810: 47 pounds, 4 ounces (21.5 kg) net; 50 pounds, 8 ounces (22.9 kg
Com-Tech 810 and 1610 Amplifier Service Manual ] 2-4 Rev. 0 10 100 1 K 10 K 100 K FREQUENCY (Hz) +2 +1 0 –1 –2 –3 –4 dB –5 –6 –7 4 ohm 8 ohm 1 watt 504.0 126.8 31.8 MILLIOHMS 8.0 2.0 6 dB 20 100 1 K 10 K 20 K 400 200 100 0 600 800 1000 1200 1400 FREQUENCY (Hz) 8 ohm 10 100 1 K 10 K 100 K FREQUENCY (Hz) Figure 2.1 Typical Frequency Response Figure 2.2 Typical Damping Factor Figure 2.3 Typical Output Impedance
Com-Tech 810 and 1610 Amplifier Service Manual ] 2-5 Rev. 0 Figure 2.4 Typical Phase Response Figure 2.5 Typical Crosstalk TEF ® Measurement 100 1 K 10 K 20 K FREQUENCY (Hz) dB TECHRON TEF ® TECHRON TEF ® +45˚ 0˚ –45˚ 100 1 K 10 K 20 K FREQUENCY (Hz) TEF ® Measurement
Com-Tech 810 and 1610 Amplifier Service Manual ] 2-6 Rev. 0 Crown specifications are guaranteed for three years. In an effort to provide you with as much information as possible about the high power-producing capabilities of your amplifier, we have created the following power matrices. Minimum Guaranteed Power Specifications Crown’s minimum power specifications represent the absolute smallest amount of output power you can expect from your amplifier when
Com-Tech 810 and 1610 Amplifier Service Manual ] 2-7 Rev. 0 Figure 2.7 Com-Tech 1610 Minimum Power Matrix Com-Tech 1610 – Minimum Guaranteed Power (Watts) Dual/Mono Mode Dual (both channels driven) Bridge-Mono (balanced output) Parallel-Mono FTC Continuous Average At 0.1% THD (See note 4) 1 kHz 20Hz-20kHz Maximum Average Load in Ohms (Constant Voltage) AC Mains 120 VAC, 60 Hz 1 kHz At 0.1% THD (See note 1) At 0.1% THD (See note 2) 20Hz-20kHz Dual (both
Com-Tech 810 and 1610 Amplifier Service Manual ] 2-8 Rev. 0 Maximum Power Specifications Crown’s maximum power specifications represent the largest amount of output power you can expect from your amplifier when it is driven to full output under the given conditions. These specifications can be used to prevent loudspeaker and hearing damage. The maximum power matrices include specifications for single cycle and 40-millisecond burst sine waves. Burst signa
Com-Tech 810 and 1610 Amplifier Service Manual ] 2-9 Rev. 0 Figure 2.9 Com-Tech 1610 Maximum Power Matrix 6.25 (70V) 4 Dual (both channels driven) Bridge-Mono (balanced output) Parallel-Mono 2 12.5 (140V) 8 3.13 (70V) 8 4 16 Dual (both channels driven) Bridge-Mono (balanced output) Parallel-Mono Com-Tech 1610 – Maximum Power (Watts) Dual/Mono Mode 40 Millisecond Tone Burst At 0.05% THD (See note 2) Single Cycle Tone Burst At less than 0.05% THD (See not
Com-Tech 810 and 1610 Amplifier Service Manual ] 3-1 Rev. 0 3 AC Power Draw and Thermal Dissipation “Soft-Star “Soft-Star “Soft-Star “Soft-Star “Soft-Start”t”t”t”t” inrush current limiting protects the house circuit breaker when several amps are turned on simul- taneously. This section provides detailed information about the amount of power and current drawn from the AC mains by the Com-Tech amplifiers and the amount of heat pro- duc

Crown Amplifier Owners Instructions: