Crown D Series Operation Manual
Text of Crown D Series Operation Manual
Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your
local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000.
This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible
situation which may arise during installation, operatio
D Series Power Amplifiers
page 2
1)
Read these instructions.
2)
Keep these instructions.
3)
Heed all warnings.
4)
Follow all instructions.
5)
Do not use this apparatus near water.
6)
Clean only with a dry cloth.
7)
Do not block any ventilation openings. Install
in accordance with the manufacturer’s instruc-
tions.
8)
Do not install near any heat sources such as
radiators, heat registers, stoves, or other
apparatus that produce heat.
9)
D
D Series Power Amplifiers Operation Manual
DECLARATION of CONFORMITY
Crown International, Inc.
Sue Whitfield
574-294-8289
[email protected]
European Representative’s Name and Address:
Nick Owen
19 Clos Nant Coslech
Pontprennau
Cardiff
CF23 8ND United Kingdom
Equipment Type: Commercial Audio Power Amplifiers
Family Name: D Family
Model Names: D-45, D-75A
EMC Standards:
EN 55103-1:1995 Electromagnetic Compatibility - Product Family Standard
D Series Power Amplifiers page 4
Important Safety Instructions .......................................................2
Declaration of Conformity ...........................................................3
1 Welcome .....................................................5
1.1 Features ...........................................................................5
1.2 How to Use This Manual .........................................
D Series Power Amplifiers Operation Manual
1 Welcome
Reliability is the first thing you get with your
purchase of a Crown® power amplifier. The D-
45 and D-75A both deliver dependable opera-
tion with a wide variety of loads. Because of
their exceptional reliability, these amplifiers
have become the leading choice of profession-
als for use in recording studios, laboratories
and public facilities. You can even find them on
the road. Their sonic exc
D Series Power Amplifiers page 6
2.1 Unpack Your Amplifier
Please unpack and inspect your amplifier for any
damage that may have occurred during transit. If
damage is found, notify the transportation company
immediately. Only you can initiate a claim for ship-
ping damage. Crown will be happy to help as
needed. Save the shipping carton as evidence of
damage for the shipper’s inspection.
We also recommend that you save all packing mate-
r
D Series Power Amplifiers Operation Manual
2.4 Choose Input Wire
and Connectors
Figure 2.3 shows connector pin assignments for
balanced wiring, and Figure 2.4 shows connec-
tor pin assignments for unbalanced wiring.
NOTE: Custom wiring should only be per-
formed by qualified personnel.
2.5 Choose Output Wire and
Connectors
Crown recommends using professionally con-
structed, high-
quality, two- or four-conductor, heavy gauge
speaker wire and connect
D Series Power Amplifiers page 8
2.6 Wire Your System
2.6.1 Dual Mode
Typical input and output wiring is shown in Figure 2.5.
INPUTS: Connect input wiring for each channel.
OUTPUTS: Maintain proper polarity (+/-) on output connec-
tors.
Connect Channel 1 positive (+) speaker load to Channel 1
positive terminal of amp; repeat for negative (-). Repeat each
channel wiring as for Channel 1. Refer to Section 2.5 for out-
put connector pin ass
D Series Power Amplifiers Operation Manual
2.7 Connect to AC Mains
Connect your amplifier to the AC mains power
source (power outlet) with the supplied AC
power cordset.
WARNING: The third prong of this con-
nector (ground) is an important safety
feature. Do not attempt to disable this
ground connection by using an adapter
or other methods.
Amplifiers don’t create energy. The AC mains
voltage and current must be sufficient to deliver
the power you
D Series Power Amplifiers page 10
3.1 Precautions
Your amplifier is protected from internal and exter-
nal faults, but you should still take the following
precautions for optimum performance and safety:
1.
Before use, your amplifier first must be config-
ured for proper operation, including input and
output wiring hookup. Improper wiring can
result in serious operating difficulties. For
information on wiring and configuration, please
consu
D Series Power Amplifiers Operation Manual
3.2 Controls, Indicators and Con-
nectors
Figure Figure 3.1 shows the controls, indica-
tors and connectors on the front panel and back
panel of the D-75A. The D-45 layout is similar.
Figure 3.1 Front and Back Views
3 Operation
WARNING: HEADPHONE JACK
SUPPLIES FULL OUTPUT POWER AND
MAY DAMAGE HEADPHONES OR
CAUSE HEARING DAMAGE.
D Series Power Amplifiers page 12
the unit’s fuse, you should be sure to fix the
source of the problem. If the problem is not
immediately apparent, the unit probably needs
to be serviced by a qualified technician.
WARNING: Always unplug the amplifier
from the AC mains before removing the
fuse.
To replace the fuse, turn off the power switch
and disconnect the power plug from the AC
mains. Unscrew the fuse holder cap (shown in
Figure 3.1,
D Series Power Amplifiers Operation Manual
NOTE: For detailed information about
these Crown amplifier features, please
consult the Crown Amplifier Application
Guide, available on the Crown website
at www.crownaudio.com.
4.1 Protection
Your amplifier is protected against all common
hazards that plague high-power amplifiers,
including shorted, open or mismatched loads;
overloaded power supplies, chain destruction
phenomena, input overload and high-fr
D Series Power Amplifiers page 14
CONDITION: Power indicator is off.
POSSIBLE REASON
•
The amplifier has lost AC power.
•
The amplifier’s Power switch is off.
•
The amplifier is not plugged into the
power receptacle.
•
The amplifier output level is so high that
the power supply fuse has blown. Verify
that input levels and output impedances
are within safe ranges. Refer the unit to
an authorized Crown service center for
fuse repla
D Series Power Amplifiers Operation Manual
6 Specifications
Minimum Guaranteed Power
D-45
D-75A
120V/60 Hz Units, Dual mode, per channel, both channels driven
1 kHz with 0.1% THD
4 ohms
8 ohms
16 ohms
35W
25W
20W
55W
40W
25W
120V/60 Hz Units, Bridge mono mode
1 kHz with 0.1% THD
8 ohms
16 ohms
70W
50W
110W
80W
Performance
D D-455
D- D-75AA
Frequency Response (at 1 watt, 20Hz - 20 kHz)
± 0.1 dB
± 0.1 dB
Phase Response (a
D Series Power Amplifiers page 16
D-45
Configuration and Load
(ohms)
FTC Continuous
Average Power at 0.1% THD
(See note 1)
Max. Aver-
age Power at
0.1% THD
(See note 2)
Single-Cycle Tone Burst
Watts at < 0.05% THD
(See note 3)
40 mS Tone Burst
Watts at < 0.05% THD
(See note 4)
EIA Watts at
1% THD
(See note 5)
20Hz-20kHz
1 kHz
1 kHz
20 Hz
50 Hz
D Series Power Amplifiers Operation Manual
Crown amplifiers are quality units that rarely require
servicing. Before returning your unit for servicing,
please contact Crown Technical Support to verify
the need for servicing.
This unit has very sophisticated circuitry which
should only be serviced by a fully trained techni-
cian. This is one reason why each unit bears the fol-
lowing label:
CAUTION: To prevent electric shock, do not
remove covers. No