Crown Macro-Tech MA-1200 Service Manual

Text of Crown Macro-Tech MA-1200 Service Manual

Macro-Tech 1200 Amplifier Service Manual

1 MACRO-TECH ®-1200 POWER AMPLIFIER SERVICE MANUAL K-SVCMA12 2-96 Macro-Tech®, ODEP® and Crown® are registered trademarks of Crown International, Inc. Mailing Address: P.O. Box 1000 Elkhart, IN U.S.A. 46515-1000 Shipping Address: 57620 C.R. 105 Elkhart, IN U.S.A. 46517 ©1996 by CROWN INTERNATIONAL, INC.
Macro-Tech 1200 Amplifier Service Manual 2 À PRÉVENIR LE CHOC ÉLECTRIQUE N’ENLEVEZ PAS LES COUVERTURES. RIEN DES PARTIES UTILES À L’INTÉRIEUR. DÉBRANCHER LA BORNE AVANT D’OUVRIR LA MODULE EN ARRIÈRE. TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. DISCONNECT POWER CORD BEFORE REMOVING REAR INPUT MODULE TO ACCESS GAIN SWITCH. CAUTION AVIS WARNING
Macro-Tech 1200 Amplifier Service Manual 3 Table of Contents Introduction ............................................................. 4 Parts Information ..................................................... 5 Specifications .......................................................... 6 Voltage Conversion ................................................. 7 Circuit Theory .......................................................... 8 Electrical Checkout Proce
Macro-Tech 1200 Amplifier Service Manual 4 Crown Technical Support Group Factory Service Parts Department Mailing Address: PO Box 1000 Elkhart, IN USA 46515-1000 Shipping Address: 57620 C.R. 105 Elkhart, IN USA 46517 Phone: (219) 294-8200 Toll Free: (800) 342-6939 FAX: (219) 294-8301 This manual contains service information on Crown power amplifiers. It is designed to be used in conjunc- tion with the applicable Owner's Manual. However, some importan
Macro-Tech 1200 Amplifier Service Manual 5 Parts Information shipment on a C.O.D. or pre-payment (check or credit card) basis. Terms Normal terms are pre-paid. Net-30 Days applies to only those firms having pre-established accounts with Crown. If pre-paying, the order must be packed and weighed before a total bill can be established, after which an amount due will be issued and shipment made upon receipt of pre-payment. New parts re- turned for credit are
Macro-Tech 1200 Amplifier Service Manual 6 Specifications Unless noted otherwise, all specifications are based on driving an 8 ohm load per channel, both channels driven, the sensitivity switch in the 26dB position, the AC supply is 120VAC at 60Hz. Crown specifications are guaranteed through the warranty period (normally 3 years). Because our testing methods are more strin- gent than our published specifications, every Crown amplifier will exceed its publi
Macro-Tech 1200 Amplifier Service Manual 7 Voltage Conversion The 120 Volt 60 Hz version, sold in the United States, is not voltage selectable. It does not have voltage selection boards. This version is to be used only with 120 Volts, 60Hz. All other versions of the Macro Tech 1200 use voltage selection boards. The following chart indicates which jumpers are used for different voltages. Note that the fuses and transmotor may need to be changed to accommoda
Macro-Tech 1200 Amplifier Service Manual 8 Theory Overview It should be noted that over time Crown makes im- provements and changes to their products for various reasons. This manual is up to date as of the time of writing. For additional information regarding these amplifiers, refer to the applicable Technical Notes provided by Crown for this product. This section of the manual explains the general opera- tion of a typical Crown power amplifier. Topics co
Macro-Tech 1200 Amplifier Service Manual 9 Theory overdriving the Error Amp. Because the Error Amp amplifies the difference between input and output signals, any difference in the two waveforms will produce a near open loop gain condition which in turn results in high peak output voltage. The output of the Error Amp, called the Error Signal (ES) drives the Voltage Translators. Voltage Amplification The Voltage Translator stage separates the output of the E
Macro-Tech 1200 Amplifier Service Manual 10 and high efficiency. High Side (HS) The High Side (HS) of the bridge operates much like a conventional bipolar push-pull output configuration. As the input drive voltage becomes more positive, the HS NPN conducts and delivers positive voltage to the load. Eventually the NPN devices reach full conduc- tion and +Vcc is across the load. At this time the HS PNP is biased off. When the drive signal is negative going,
Macro-Tech 1200 Amplifier Service Manual 11 with respect to ground, but ±Vcc remain constant with respect to each other. This allows the power supply to deliver +Vcc and -Vcc from the same bridge rectifier and filter as a total difference in potential, regardless of their voltages with respect to ground. The LS uses inverted feedback from the HS output to control the ground reference for the rails (±Vcc). Both LS quad- rants are arranged in a three-deep
Macro-Tech 1200 Amplifier Service Manual 12 Theory NEGATIVE LOW SIDE OUTPUT PNP STAGE POSITIVE LOW SIDE OUTPUT NPN STAGE NEGATIVE HIGH SIDE OUTPUT PNP STAGE POSITIVE HIGH SIDE OUTPUT NPN STAGE HIGH SIDE BIAS SERVO +LVA -1 -LVA -1 +VOLTAGE TRANSLATOR -VOLTAGE TRANSLATOR OUTPUT DEVICE EMULATION PROTECTION ERROR AMP VGS BGS BALANCED INPUTS INVERTING BRIDGE BALANCE LOW SIDE BIAS DIODE STRING -1 -1 MAIN NEGATIVE FEEDBACK (NFb) LOOP Figure 3. Typical Crown Ampli
Macro-Tech 1200 Amplifier Service Manual 13 Electrical Checkout Procedures General Information The following test procedures are to be used to verify operation of this amplifier. DO NOT connect a load or inject a signal unless directed to do so by the proce- dure. These tests, though meant for verification and alignment of the amplifier, may also be very helpful in troubleshooting. For best results, tests should be performed in order. All tests assume that
Macro-Tech 1200 Amplifier Service Manual 14 Test 6: Voltage Gain Spec 26dB Gain: Gain of 20.0 ±3%. Spec 0.775V Sensitivity: ±6%. Spec 1.4V Sensitivity: +12%/–6%. Initial Conditions: Controls per standard. Procedure: No load connected. Inject a 0.775 VAC 1 kHz sine wave with the Sensitivity Switch in the 26 dB position. Measure 15.5 VAC ±0.5 VAC at the amplifier output. Inject a 0.775 VAC 1 kHz sine wave with the Sensitivity Switch in the 0.775V positi
Macro-Tech 1200 Amplifier Service Manual 15 Electrical Checkout Procedures Procedure Short: Inject a 60 Hz sine wave at 20 VAC output. After establishing signal, short the output for 10 seconds. Test 14: ODEP Limiting Spec: No oscillation on ODEP Limiting wave form; either channel controls limiting in Parallel Mono Mode. Initial Conditions: Controls per standard; rag or other obstruction blocking fan so that it does not turn. Procedure: Load the amplifier
Macro-Tech 1200 Amplifier Service Manual 16 Test 20: Clipping Spec: No protective action during test. Initial Conditions: Controls per standard. Procedure: Load each channel to 8 ohms. Inject a 1 kHz sine wave at each input and drive output 6 dB into clip for 10 seconds. The amplifier should not activate any protective circuits (ODEP, Fault, or LF Protection). Post Testing After completion of testing, if all tests are satisfactory, the amplifier controls s
Macro-Tech 1200 Amplifier Service Manual 17 Parts List (Non-Module) Supplimental Items CPN ITEM QTY D 4137-2 Nylon Thumbscrew Washer 4 C 3342-0 Feet, Black Self-Stick 4 A10087-71012 10-32 .75 Machine (Rack Screw) 4 K80449D2 MA Series Owners Manual 1 Power Supply CPN ITEM QTY M44213-3 MA Fuse Module Assembly (120V, 60Hz Units Only) 1 D 8069-4 Fuse Board Insulator 1 Q42863-3 Fuse Module, Ch 1 (50-60 Hz Units) 1 Q42862-5 Fuse Module, Ch 2 (50-60 Hz Units) 1 A

Crown Amplifier Owners Instructions: