Crown Macro-Tech MA-1200 Service Manual
Text of Crown Macro-Tech MA-1200 Service Manual
Macro-Tech 1200 Amplifier Service Manual
1
MACRO-TECH
®-1200
POWER AMPLIFIER
SERVICE MANUAL
K-SVCMA12
2-96
Macro-Tech®, ODEP® and Crown® are registered trademarks of Crown International, Inc.
Mailing Address:
P.O. Box 1000
Elkhart, IN U.S.A. 46515-1000
Shipping Address:
57620 C.R. 105
Elkhart, IN U.S.A. 46517
©1996 by CROWN INTERNATIONAL, INC.
Macro-Tech 1200 Amplifier Service Manual 2
À PRÉVENIR LE CHOC
ÉLECTRIQUE N’ENLEVEZ
PAS LES COUVERTURES.
RIEN DES PARTIES
UTILES À L’INTÉRIEUR.
DÉBRANCHER LA BORNE
AVANT D’OUVRIR LA
MODULE EN ARRIÈRE.
TO PREVENT ELECTRIC SHOCK DO
NOT REMOVE TOP OR BOTTOM
COVERS. NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE
PERSONNEL. DISCONNECT
POWER CORD BEFORE REMOVING
REAR INPUT MODULE TO ACCESS
GAIN SWITCH.
CAUTION
AVIS
WARNING
Macro-Tech 1200 Amplifier Service Manual 3
Table of Contents
Introduction ............................................................. 4
Parts Information ..................................................... 5
Specifications .......................................................... 6
Voltage Conversion ................................................. 7
Circuit Theory .......................................................... 8
Electrical Checkout Proce
Macro-Tech 1200 Amplifier Service Manual 4
Crown
Technical Support Group
Factory Service
Parts Department
Mailing Address:
PO Box 1000
Elkhart, IN USA 46515-1000
Shipping Address:
57620 C.R. 105
Elkhart, IN USA 46517
Phone: (219) 294-8200
Toll Free: (800) 342-6939
FAX: (219) 294-8301
This manual contains service information on Crown
power amplifiers. It is designed to be used in conjunc-
tion with the applicable Owner's Manual. However,
some importan
Macro-Tech 1200 Amplifier Service Manual 5
Parts Information
shipment on a C.O.D. or pre-payment (check or credit
card) basis.
Terms
Normal terms are pre-paid. Net-30 Days applies to
only those firms having pre-established accounts with
Crown. If pre-paying, the order must be packed and
weighed before a total bill can be established, after
which an amount due will be issued and shipment
made upon receipt of pre-payment. New parts re-
turned for credit are
Macro-Tech 1200 Amplifier Service Manual 6
Specifications
Unless noted otherwise, all specifications are based
on driving an 8 ohm load per channel, both channels
driven, the sensitivity switch in the 26dB position, the
AC supply is 120VAC at 60Hz. Crown specifications
are guaranteed through the warranty period (normally
3 years). Because our testing methods are more strin-
gent than our published specifications, every Crown
amplifier will exceed its publi
Macro-Tech 1200 Amplifier Service Manual 7
Voltage Conversion
The 120 Volt 60 Hz version, sold in the United States,
is not voltage selectable. It does not have voltage
selection boards. This version is to be used only with
120 Volts, 60Hz.
All other versions of the Macro Tech 1200 use voltage
selection boards. The following chart indicates which
jumpers are used for different voltages. Note that the
fuses and transmotor may need to be changed to
accommoda
Macro-Tech 1200 Amplifier Service Manual 8
Theory
Overview
It should be noted that over time Crown makes im-
provements and changes to their products for various
reasons. This manual is up to date as of the time of
writing. For additional information regarding these
amplifiers, refer to the applicable Technical Notes
provided by Crown for this product.
This section of the manual explains the general opera-
tion of a typical Crown power amplifier. Topics co
Macro-Tech 1200 Amplifier Service Manual 9
Theory
overdriving the Error Amp. Because the Error Amp
amplifies the difference between input and output
signals, any difference in the two waveforms will
produce a near open loop gain condition which in turn
results in high peak output voltage. The output of the
Error Amp, called the Error Signal (ES) drives the
Voltage Translators.
Voltage Amplification
The Voltage Translator stage separates the output of
the E
Macro-Tech 1200 Amplifier Service Manual 10
and high efficiency.
High Side (HS)
The High Side (HS) of the bridge operates much like
a conventional bipolar push-pull output configuration.
As the input drive voltage becomes more positive, the
HS NPN conducts and delivers positive voltage to the
load. Eventually the NPN devices reach full conduc-
tion and +Vcc is across the load. At this time the HS
PNP is biased off. When the drive signal is negative
going,
Macro-Tech 1200 Amplifier Service Manual 11
with respect to ground, but ±Vcc remain constant with
respect to each other. This allows the power supply to
deliver +Vcc and -Vcc from the same bridge rectifier
and filter as a total difference in potential, regardless
of their voltages with respect to ground. The LS uses
inverted feedback from the HS output to control the
ground reference for the rails (±Vcc). Both LS quad-
rants are arranged in a three-deep
Macro-Tech 1200 Amplifier Service Manual 12
Theory
NEGATIVE
LOW SIDE
OUTPUT
PNP STAGE
POSITIVE
LOW SIDE
OUTPUT
NPN STAGE
NEGATIVE
HIGH SIDE
OUTPUT
PNP STAGE
POSITIVE
HIGH SIDE
OUTPUT
NPN STAGE
HIGH SIDE
BIAS
SERVO
+LVA
-1
-LVA
-1
+VOLTAGE
TRANSLATOR
-VOLTAGE
TRANSLATOR
OUTPUT
DEVICE
EMULATION
PROTECTION
ERROR
AMP
VGS
BGS
BALANCED
INPUTS
INVERTING
BRIDGE
BALANCE
LOW SIDE
BIAS
DIODE
STRING
-1
-1
MAIN NEGATIVE FEEDBACK (NFb) LOOP
Figure 3. Typical Crown Ampli
Macro-Tech 1200 Amplifier Service Manual 13
Electrical Checkout Procedures
General Information
The following test procedures are to be used to verify
operation of this amplifier. DO NOT connect a load or
inject a signal unless directed to do so by the proce-
dure. These tests, though meant for verification and
alignment of the amplifier, may also be very helpful in
troubleshooting. For best results, tests should be
performed in order.
All tests assume that
Macro-Tech 1200 Amplifier Service Manual 14
Test 6: Voltage Gain
Spec 26dB Gain: Gain of 20.0 ±3%.
Spec 0.775V Sensitivity: ±6%.
Spec 1.4V Sensitivity: +12%/–6%.
Initial Conditions: Controls per standard.
Procedure: No load connected. Inject a 0.775 VAC 1
kHz sine wave with the Sensitivity Switch in the 26 dB
position. Measure 15.5 VAC ±0.5 VAC at the amplifier
output. Inject a 0.775 VAC 1 kHz sine wave with the
Sensitivity Switch in the 0.775V positi
Macro-Tech 1200 Amplifier Service Manual 15
Electrical Checkout Procedures
Procedure Short: Inject a 60 Hz sine wave at 20 VAC
output. After establishing signal, short the output for
10 seconds.
Test 14: ODEP Limiting
Spec: No oscillation on ODEP Limiting wave form;
either channel controls limiting in Parallel Mono Mode.
Initial Conditions: Controls per standard; rag or other
obstruction blocking fan so that it does not turn.
Procedure: Load the amplifier
Macro-Tech 1200 Amplifier Service Manual 16
Test 20: Clipping
Spec: No protective action during test.
Initial Conditions: Controls per standard.
Procedure: Load each channel to 8 ohms. Inject a 1 kHz
sine wave at each input and drive output 6 dB into clip
for 10 seconds. The amplifier should not activate any
protective circuits (ODEP, Fault, or LF Protection).
Post Testing
After completion of testing, if all tests are satisfactory,
the amplifier controls s
Macro-Tech 1200 Amplifier Service Manual 17
Parts List (Non-Module)
Supplimental Items
CPN
ITEM
QTY
D 4137-2
Nylon Thumbscrew Washer
4
C 3342-0
Feet, Black Self-Stick
4
A10087-71012
10-32 .75 Machine (Rack Screw)
4
K80449D2
MA Series Owners Manual
1
Power Supply
CPN
ITEM
QTY
M44213-3
MA Fuse Module Assembly (120V, 60Hz Units Only)
1
D 8069-4
Fuse Board Insulator
1
Q42863-3
Fuse Module, Ch 1 (50-60 Hz Units)
1
Q42862-5
Fuse Module, Ch 2 (50-60 Hz Units)
1
A