Crown MICRO-TECH-1200 Reference Manual
Text of Crown MICRO-TECH-1200 Reference Manual
Crown MICRO-TECH-1200 Micro-Tech 600, 1200 & 2400
Micro-Tech 601, 1201 & 2401
Some models may be exported under the name Amcron.®
102990-1
7/97
© 1997 by Crown International, Inc., P.O. Box 1000, Elkhart, IN 46515-1000 U.S.A. Telephone: 219-294-8000.
Fax: 219-294-8329. Micro-Tech amplifiers are produced by the Professional Audio Division of Crown
International, Inc. Trademark Notice: Grounded bridge™ is a trademark and A
SUMMARY OF WARRANTY
The Crown Audio Division of Crown International, Inc., 1718 West
Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you,
the ORIGINAL PURCHASER and ANY SUBSEQUENT OWNER of each
NEW Crown1 product, for a period of three (3) years from the date of
purchase by the original purchaser (the “warranty period”) that the new
Crown product is free of defects in materials and workmanship, and we
further warrant the new Cr
WATCH FOR THESE SYMBOLS:
The lightning bolt
triangle is used to
alert the user to the
risk of electric shock.
The exclamation point
triangle is used to alert the
user to important operating or
maintenance instructions.
WARNING
TO REDUCE THE RISK OF ELECTRIC
SHOCK, DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE!
Magnetic Field
CAUTION! Do not locate sensitive high-gain equip-
ment such as preamplifiers or tape decks directly
ab
Micro-Tech 600/1200/2400 Power Amplifiers
CONTENTS
1
Welcome .......................................................................... 7
1.1 Unpacking ................................................................. 7
1.2 Features .................................................................... 7
2
Facilities .......................................................................... 8
3
Installation ...........................................
Micro-Tech 600/1200/2400 Power Amplifiers ILLUSTRATIONS
1.1
Micro-Tech Amplifier .................................................................. 7
2.1
Front Facilities ............................................................................ 8
2.2
Rear Facilities ............................................................................ 9
3.1
Mounting Dimensions .............................................................. 10
3.2
Top View
Micro-Tech 600/1200/2400 Power Amplifiers 1 Welcome
Congratulations on your purchase of a Micro-Tech®
professional power amplifier. Crown’s Micro-Tech 600,
1200 and 2400 are the original industry standards for
touring amplifiers. Micro-Tech amplifiers are known
around the world as a the benchmark for high-density,
ultra-pure power in a compact, lightweight package.
In addition, each model gives you Crown’s legendary
ODEP® protection to keep t
Micro-Tech 600/1200/2400 Power Amplifiers Fig. 2.1 Front Facilities
ODEP
CH1
CH2
POWER
OFF
A
B
C
C
D
2 Facilities
A. Filter Grille
This metal grille supports and protects the dust
filter (B). To clean the dust filter, detach the grille by
removing the three screws that hold it in place.
B. Dust Filter
The dust filter removes large particles from the air
drawn by the cooling fan. Check the filter regularly to
prevent clogging (see Sections 3.2 and
Micro-Tech 600/1200/2400 Power Amplifiers Fig. 2.2 Rear Facilities
CAUTION:
THIS COVER IS NECESSARY FOR
EFFICIENT COOLING OF THE AMPLIFIER.
REMOVE ONLY TO ACCESS GAIN SWITCH.
0
1
2
3
4
5
6
7
8
9
10
11
12
0
1
2
3
4
5
6
7
8
9
10
11
12
BRIDGE-MONO WIRING
TURN AMPLIFIER OFF.
SET STEREO/MONO
SWITCH TO
BRIDGE-MONO.
OUTPUT ACROSS
RED TERMINALS
ONLY. (CH-1
IS POSITIVE.)
PARALLEL-MONO WIRING
TURN AMPLIFIER OFF.
SET STEREO/MONO
SWITCH TO
PARALLEL-MONO.
ADD
Micro-Tech 600/1200/2400 Power Amplifiers 3 Installation
3.1 Mounting
Micro-Tech amplifiers are designed for standard 19-
inch (48.3 cm) rack mounting or stacking without a
cabinet. In a rack, it is best to mount units directly on
top of each other. This provides the most efficient air
flow and support. If the rack will be transported, we
recommend that you provide support for the amplifier’s
back panel or secure it to the rack to help support t
Micro-Tech 600/1200/2400 Power Amplifiers the rack so it blows outside air into the space between
the door and the front of the amplifiers. This will pres-
surize the “chimney” behind the door (Figure 3.3, Op-
tion 1). The blower should not blow air into or take air
out of the space behind the amplifiers. For racks with-
out a front door, you can evacuate the rack by mount-
ing the blower at the top of the rack so air blows out the
back (Figur
Micro-Tech 600/1200/2400 Power Amplifiers CAUTION: In Stereo mode, never tie the amplifier’s
outputs directly together, and never parallel them
with the output of another amplifier. Such connec-
tions do not increase the output power and may acti-
vate the protection circuitry to prevent overheating.
3.3.2 Bridge-Mono Operation
Bridge-Mono mode is used to drive loads with a total
impedance of at least 4 ohms (see Section 3.3.3 if the
load is les
Micro-Tech 600/1200/2400 Power Amplifiers CAUTION: Only connect balanced equipment
(meters, switches, etc.) to the Bridge-Mono output.
Both sides of the line must be isolated from the in-
put grounds or oscillations may occur.
3.3.3 Parallel-Mono Operation
Parallel-Mono mode is used to drive loads with a total
impedance of less than 4 ohms (see Section 3.3.2 if
the load is 4 ohms or more). Installing the amplifier in
Parallel-Mono mode is very dif
Micro-Tech 600/1200/2400 Power Amplifiers 3.3.4 Input Connection
The balanced phone jack inputs have a nominal im-
pedance of 20 K ohms (10 K ohms with unbalanced
wiring) and will accept the line-level output of most de-
vices. Three-pin female XLR connectors are also avail-
able on the optional MT-XLR accessory and balanced
barrier block connectors are available on the optional
MT-BB accessory (see Section 8.2). Correct input wir-
ing will depend
Micro-Tech 600/1200/2400 Power Amplifiers SOLVING INPUT PROBLEMS
Sometimes large subsonic (subaudible) frequencies
are present in the input signal. These can damage
loudspeakers by overloading or overheating them. To
attenuate such frequencies, place a capacitor in se-
ries with the input signal line. The graph in Figure 3.10
shows some possible capacitor values and how they
affect frequency response. Use only low-leakage pa-
per, mylar or tantalu
Micro-Tech 600/1200/2400 Power Amplifiers conductors that could bisect the magnetic field.
Ground loops will also occur when the input and out-
put grounds are tied together. DO NOT CONNECT THE
INPUT AND OUTPUT GROUNDS TOGETHER. Tying
the input and output grounds together can also cause
feedback oscillation from the load current flowing in
the loop. To avoid this problem use proper grounding,
isolate the inputs, and isolate other common AC de-
vic
Micro-Tech 600/1200/2400 Power Amplifiers 1. Note the load resistance of the loudspeakers connected
to each channel of the amplifier. Mark this value on the
“Load Resistance” line of the nomograph.
2. Select an acceptable damping factor and mark it on the
“Damping Factor” line. Your amplifier can provide an excel-
lent damping factor of 1,000 from 10 to 400 Hz in Stereo
mode with an 8 ohm load. In contrast, typical damping fac-
tors are 50