Some models may be exported under the name Amcron.® ©2000 by Crown International, Inc., P.O. Box 1000, Elkhart, Indiana 46515-1000 U.S.A. Telephone: 219-294-8000. Power-Tech amplifiers are produced by the Professional Audio Unit of Crown International, Inc. Trademark Notice: Power-Tech™ is a trademark and Amcron,® Crown,® IOC ® and ODEP ® are registered trademarks of Crown International, Inc. Other trademarks are the pr

SUMMARY OF WARRANTY

The Crown Audio Division of Crown International, Inc., 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you, the ORIGINAL PURCHASER and ANY SUBSEQUENT OWNER of each NEW Crown1 product, for a period of three (3) years from the date of purchase by the original purchaser (the “warranty period”) that the new Crown product is free of defects in materials and workmanship, and we further warrant the new Cr

TO REDUCE THE RISK OF ELECTRIC

SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE! Magnetic Field                 !   ! "    # Because this amplifier has a high power density, it has a strong magnetic field which can induce hum into unshielded devices that are located nearby. The field is strongest just above and below the unit. If an equipment rack is used, we re

Power-Tech Series Power Amplifiers

Page 4 Reference Manual CONTENTS 1 Welcome ................................................... 5 1.1 Unpacking..................................................................... 5 1.2 Features ........................................................................ 5 2 Installation ................................................. 6 2.1 Stereo 6 2.2 Mono 6 2.3 Input Sensitivity Adjustment ..............................
Power-Tech Series Power Amplifiers Page 5 Reference Manual 1.1 Unpacking Please unpack and inspect your new amplifier for any damage that may have occurred during transit. If damage is found, notify the transportation company immediately. Only you may initiate a claim with the carrier for shipping damage. Even if the unit arrived in perfect condition, as most do, save all packing materials so you will have them if you ever need to transport the unit. NEVE
Power-Tech Series Power Amplifiers Page 6 Reference Manual 2 Installation Always remove power from the unit and turn the level controls off (fully counterclockwise) when making or breaking connections. This reduces the chance of blasts that can cause loudspeaker damage. The guidelines below are provided to help you quickly get your amplifier installed and ready to go. Be sure to follow the instructions in Sections 2.1 and 2.2 for the selected mode of oper
Power-Tech Series Power Amplifiers Page 7 Reference Manual Fig. 2.3 Three System Connection Methods
Power-Tech Series Power Amplifiers Page 8 Reference Manual 2.3 Input Sensitivity Adjustment The input sensitivity switch inside the amplifier is set to 0.775 volts at the factory.* It can be changed to 1.4 volts or a voltage gain of 26 dB as follows: 1. Turn off and unplug the amplifier from the AC source. 2. Remove the access cover on the back panel. 3. Locate the labeled access hole for the sensitivity switch. 4. Set the switch to the desired position.
Power-Tech Series Power Amplifiers Page 9 Reference Manual 3 Operation 3.1 Precautions Although your amplifier is protected from external faults, the following safety precautions are recommended: 1. There are important differences among the Stereo, Bridge-Mono and Parallel-Mono operating modes. Please refer to Section 2 for additional information. 2. WARNING: Do not change the position of the stereo/mono switch unless the amplifier is first turned off. 3.
Power-Tech Series Power Amplifiers Page 10 Reference Manual The amplifier’s fault protection system will put the amplifier in drive protection mode in rare situations where heavy common-mode current is detected in the output. The unit should never output heavy common- mode current unless its circuitry is damaged. Activating drive protection helps prevent further damage. 3.3.4 Transformer Thermal Protection All Power-Tech amplifiers have transformer ther
Power-Tech Series Power Amplifiers Page 11 Reference Manual 4 Specifications The following applies to units in Stereo mode with 8-ohm loads and an input sensitivity of 26 dB unless otherwise specified. Standard 1 kHz Power: refers to maximum average power in watts at 1 kHz with 0.1% THD. Full Bandwidth Power: refers to maximum average power in watts from 20 Hz to 20 kHz with 0.1% THD. 120 VAC, 60 Hz Units: refers to amplifiers with dedicated transformers
Power-Tech Series Power Amplifiers Page 12 Reference Manual You must provide sufficient AC power to the amplifier. Amplifiers do not create energy—they require proper voltage and current to deliver the power you expect. Low-Voltage Power Supply: A ±24 VDC fanformer supply (fan motor winding) regulated to ±15 VDC. AC Connector: An appropriate AC line cord and plug are provided. North American units have a standard 3-wire, 15-amp grounded connector (NE
Power-Tech Series Power Amplifiers Page 13 Reference Manual Crown specifications are guaranteed for three years. In an effort to provide you with as much information as possible about the high power-producing capabilities of your amplifier, we have created the following power matrices. Minimum Power Specifications Crown’s minimum power specifications represent the absolute smallest amount of output power you can expect from your amplifier when it is dri
Power-Tech Series Power Amplifiers Page 14 Reference Manual Fig. 4.2 Power-Tech 2 Minimum Power Matrix Fig. 4.3 Power-Tech 3 Minimum Power Matrix
Power-Tech Series Power Amplifiers Page 15 Reference Manual Maximum Power Specifications Crown’s maximum power specifications represent the largest amount of output power you can expect from your amplifier when it is driven to full output under the given conditions. These specifications can be used to prevent loudspeaker and hearing damage. The maximum power matrices include specifications for single cycle and 40-millisecond burst sine waves. Burst sign
Power-Tech Series Power Amplifiers Page 16 Reference Manual Fig. 4.5 Power-Tech 2 Maximum Power Matrix Fig. 4.6 Power-Tech 3 Maximum Power Matrix
Power-Tech Series Power Amplifiers Page 17 Reference Manual 5 Accessories There are two accessories available at the time of this printing: the MT-XLR and the MT-BB. Important: The MT-XLR and MT-BB must be installed at a Crown Factory Service Center or the Crown factory. 5.1 MT-XLR The MT-XLR is an accessory panel that provides two standard 3-pin female XLR input connectors. The MT-XLR accessory makes it easy to quickly change connections in a system that
Power-Tech Series Power Amplifiers Page 18 Reference Manual Crown Audio Customer Service Technical Support / Factory Service Plant 2 SW, 1718 W. Mishawaka Rd., Elkhart, Indiana 46517 U.S.A. Telephone: 219-294-8200 800-342-6939 (North America, Puerto Rico, and Virgin Islands only) Facsimile: 219-294-8301 (Technical Support) 219-294-8124 (Factory Service) Fax Back: 219-293-9200 (North America only) 800-294-4094 (North America only) 219-294-8100 (Internat
Power-Tech Series Power Amplifiers Page 19 Reference Manual Page 19 Crown Factory Service Information Shipping Address: Crown International, Inc., Factory Service, Plant 2 SW, 1718 W. Mishawaka Rd., Elkhart, IN U.S.A. 46517 Phone: 1-800-342-6939 or 1-219-294-8200 Fax: 1-219-294-8124 Owner’s Name: _________________________________________________________________________ Shipping Address: _________________________________________________________________