• Safety
• Operation
• Maintenance
• Español
CAUTION: Read, understand and
follow Safety Rules and Operating
Instructions in this manual before
using this product.
TABLE OF CONTENTS
Page
Warranty
3
Safety Instructions
4
Safety Symbols
5
Control and Jacks
6
Symbols and Annunciators
6
Specifications
7
Battery Installation
9
Operating Instructions
10
DC Voltage Measurements
10
AC Voltage Measurements
11
DC Current Measurements
12
AC Current Measurements
13
Resistance Measurements
14
Continuity Check
14
Diode Test
15
Battery Test
15
Maintenance
16
Replacing Batteries
17
Replacing Fuses
17
Troubleshooting
18
Service and
ONE YEAR FULL WARRANTY
ONE YEAR FULL WARRANTY ON CRAFTSMAN MANUAL RANGING
MULTIMETER
If this CRAFTSMAN Manual Ranging MultiMeter fails to give complete
satisfaction within one year from the date of purchase, RETURN IT TO
THE NEAREST SEARS STORE OR OTHER CRAFTSMAN OUTLET IN
THE UNITED STATES, and Sears will replace it, free of charge.
If this CRAFTSMAN Manual Ranging MultiMeter is used for commercial
or rental purposes, this warranty applies for 90 days f
Craftsman 82141 This meter has been designed for safe use, but must be operated with
caution. The rules listed below must be carefully followed for safe operation.
1.
NEVER apply voltage or current to the meter that exceeds the
specified maximum:
Input Limits
Function
Maximum Input
VAC
600V DC/AC
V DC or V AC
600V DC/AC, 200Vrms on 200mV range
mA DC
200mA 250V fast acting fuse
A DC
10A 250V fast acting fuse(30 seconds max
every 15 minutes)
Resistance
This symbol adjacent to another symbol, terminal or
operating device indicates that the operator must refer
to an explanation in the Operating Instructions to avoid
personal injury or damage to the meter.
This WARNING symbol indicates a potentially
hazardous situation, which if not avoided, could result
in death or serious injury.
This CAUTION symbol indicates a potentially
hazardous situation, which if not avoided, may result
damage to th
CONTROLS AND JACKS
1.
LCD Display
2.
Function switch
3.
COM jack
4.
10A jack
5.
Positive jack
Note: Tilt stand, fuse and battery
compartment are on rear of unit.
SYMBOLS AND ANNUNCIATORS
•)))
Continuity
Diode test
m
milli ( volts, amps)
k
kilo (ohms)
Ω
ohms
VDC
volts direct current
VAC
volts alternating current
ADC
amps direct current
AAC
amps alternating current
BAT
Battery test
1
2
3
4
5
±(0.5% reading + 2 digits)
200V
0.1V
AC Voltage
(V AC)
600V
1V
±(1.5% reading + 5 digits
(50/60Hz)
200mA
100µA
±(1.2% reading + 2 digits)
DC Current
(A DC)
10A
10mA
±(2.0% reading + 2 digits)
200mA
100µA
±(1.8% reading + 5 digits)
AC Current
(A AC)
10A
10mA
±(3.0% reading + 5 digits)
200Ω
0.1Ω
2000Ω
1Ω
20kΩ
0.01kΩ
200
Test current of 1mA maximum, open circuit
voltage 2.8V DC typical
Continuity Check
Audible signal will sound if the resistance is less
than approximately 30Ω
Battery Test current
9V (6mA); 1.5V (100mA)
Input Impedance
>1MΩ
ACV Bandwidth
45Hz to 450Hz
DCA voltage drop
200mV
Display
3 ½ digit, 2000 count LCD, 0.5” digits
Overrange indication
“1” is displayed
Polarity
Automatic (no indication for positive polarity);
Minu
Craftsman 82141 WARNING: To avoid electric shock, disconnect the test leads from any
source of voltage before removing the battery door.
1. Disconnect the test leads from the meter.
2. Remove the protective rubber holster (if installed).
3. Open the battery door by loosening the screw using a
Phillips head screwdriver.
4. Insert the battery into battery holder, observing the
correct polarity.
5. Put the battery door back in place. Secure with the
sc
WARNING: Risk of electrocution. High-voltage circuits, both AC and DC,
are very dangerous and should be measured with great care.
1. ALWAYS turn the function switch to the OFF position when the meter is
not in use.
2. If “1” appears in the display during a measurement, the value exceeds
the range you have selected. Change to a higher range.
NOTE: On some low AC and DC voltage ranges, with the test leads not
connected to a devi
AC VOLTAGE MEASUREMENTS
WARNING: Risk of Electrocution. The probe tips may not be long
enough to contact the live parts inside some 240V outlets for
appliances because the contacts are recessed deep in the outlets. As
a result, the reading may show 0 volts when the outlet actually has
voltage on it. Make sure the probe tips are touching the metal contacts
inside the outlet before assuming that no voltage is present.
CAUTION: Do not measure AC voltages
Craftsman Multimeter Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | For Device |
|---|---|---|---|---|---|---|---|
82005 |
#568EE1: 82005 Multimeter Owner's manual |
22 | 0.46 Mb | 671 | 101 | 25-04-2026 | view all |
82017 |
Multimeter #HFT166 |
6 | 0.16 Mb | 225 | 54 | 20-05-2026 | view all |
82339 |
82339 Owner's manual - DZ3769 |
17 | 1227 | 295 | 08-09-2026 | view all | |
82337 |
82337 Owner's manual - 591639 |
21 | 0.62 Mb | 273 | 61 | 19-04-2026 | view all |
82345 |
Craftsman Multimeter Owner's manual (File: PDF, 20-09-2026) |
38 | 0.95 Mb | 1331 | 213 | 20-09-2026 | view all |
320.48277 |
320.48277 Owner's manual - 5I8H62 |
24 | 1.55 Mb | 46 | 7 | 19-08-2026 | view all |
161.210400 |
Craftsman Multimeter Owner's manual (File: PDF, 30-09-2026) |
64 | 4.93 Mb | 932 | 178 | 30-09-2026 | view all |
82354 |
Craftsman 82354 User Manual (Owner's manual), @6S274Q |
32 | 0.86 Mb | 293 | 62 | 01-07-2026 | view all |
82140 |
82140 (Multimeter ePDF User Manual, #8VS5CH) |
43 | 1.11 Mb | 711 | 157 | 15-09-2026 | view all |
82312 |
Craftsman 82312 User Guide (Owner's manual), @IBVV4I |
46 | 1.3 Mb | 1435 | 244 | 24-05-2026 | view all |