Craftsman 82141 Owner's Manual

Text of Craftsman 82141 Owner's Manual

© Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.

www.craftsman.com 070606 • Safety • Operation • Maintenance • Español CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.

TABLE OF CONTENTS

Page Warranty 3 Safety Instructions 4 Safety Symbols 5 Control and Jacks 6 Symbols and Annunciators 6 Specifications 7 Battery Installation 9 Operating Instructions 10 DC Voltage Measurements 10 AC Voltage Measurements 11 DC Current Measurements 12 AC Current Measurements 13 Resistance Measurements 14 Continuity Check 14 Diode Test 15 Battery Test 15 Maintenance 16 Replacing Batteries 17 Replacing Fuses 17 Troubleshooting 18 Service and

ONE YEAR FULL WARRANTY

ONE YEAR FULL WARRANTY ON CRAFTSMAN MANUAL RANGING MULTIMETER If this CRAFTSMAN Manual Ranging MultiMeter fails to give complete satisfaction within one year from the date of purchase, RETURN IT TO THE NEAREST SEARS STORE OR OTHER CRAFTSMAN OUTLET IN THE UNITED STATES, and Sears will replace it, free of charge. If this CRAFTSMAN Manual Ranging MultiMeter is used for commercial or rental purposes, this warranty applies for 90 days f

Craftsman 82141 This meter has been designed for safe use, but must be operated with

caution. The rules listed below must be carefully followed for safe operation. 1. NEVER apply voltage or current to the meter that exceeds the specified maximum: Input Limits Function Maximum Input VAC 600V DC/AC V DC or V AC 600V DC/AC, 200Vrms on 200mV range mA DC 200mA 250V fast acting fuse A DC 10A 250V fast acting fuse(30 seconds max every 15 minutes) Resistance

This symbol adjacent to another symbol, terminal or

operating device indicates that the operator must refer to an explanation in the Operating Instructions to avoid personal injury or damage to the meter. This WARNING symbol indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury. This CAUTION symbol indicates a potentially hazardous situation, which if not avoided, may result damage to th

CONTROLS AND JACKS

1. LCD Display 2. Function switch 3. COM jack 4. 10A jack 5. Positive jack Note: Tilt stand, fuse and battery compartment are on rear of unit. SYMBOLS AND ANNUNCIATORS •))) Continuity Diode test m milli ( volts, amps) k kilo (ohms) Ω ohms VDC volts direct current VAC volts alternating current ADC amps direct current AAC amps alternating current BAT Battery test 1 2 3 4 5

±(0.5% reading + 2 digits)

200V 0.1V AC Voltage (V AC) 600V 1V ±(1.5% reading + 5 digits (50/60Hz) 200mA 100µA ±(1.2% reading + 2 digits) DC Current (A DC) 10A 10mA ±(2.0% reading + 2 digits) 200mA 100µA ±(1.8% reading + 5 digits) AC Current (A AC) 10A 10mA ±(3.0% reading + 5 digits) 200Ω 0.1Ω 2000Ω 1Ω 20kΩ 0.01kΩ 200

Test current of 1mA maximum, open circuit

voltage 2.8V DC typical Continuity Check Audible signal will sound if the resistance is less than approximately 30Ω Battery Test current 9V (6mA); 1.5V (100mA) Input Impedance >1MΩ ACV Bandwidth 45Hz to 450Hz DCA voltage drop 200mV Display 3 ½ digit, 2000 count LCD, 0.5” digits Overrange indication “1” is displayed Polarity Automatic (no indication for positive polarity); Minu

Craftsman 82141 WARNING: To avoid electric shock, disconnect the test leads from any

source of voltage before removing the battery door. 1. Disconnect the test leads from the meter. 2. Remove the protective rubber holster (if installed). 3. Open the battery door by loosening the screw using a Phillips head screwdriver. 4. Insert the battery into battery holder, observing the correct polarity. 5. Put the battery door back in place. Secure with the sc

WARNING: Risk of electrocution. High-voltage circuits, both AC and DC,

are very dangerous and should be measured with great care. 1. ALWAYS turn the function switch to the OFF position when the meter is not in use. 2. If “1” appears in the display during a measurement, the value exceeds the range you have selected. Change to a higher range. NOTE: On some low AC and DC voltage ranges, with the test leads not connected to a devi

AC VOLTAGE MEASUREMENTS

WARNING: Risk of Electrocution. The probe tips may not be long enough to contact the live parts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets. As a result, the reading may show 0 volts when the outlet actually has voltage on it. Make sure the probe tips are touching the metal contacts inside the outlet before assuming that no voltage is present. CAUTION: Do not measure AC voltages

Craftsman Multimeter Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated For Device
82005

#568EE1: 82005 Multimeter Owner's manual

22 0.46 Mb 671 101 25-04-2026 view all
82017

Multimeter #HFT166

6 0.16 Mb 225 54 20-05-2026 view all
82339

82339 Owner's manual - DZ3769

17 1227 295 08-09-2026 view all
82337

82337 Owner's manual - 591639

21 0.62 Mb 273 61 19-04-2026 view all
82345

Craftsman Multimeter Owner's manual (File: PDF, 20-09-2026)

38 0.95 Mb 1331 213 20-09-2026 view all
320.48277

320.48277 Owner's manual - 5I8H62

24 1.55 Mb 46 7 19-08-2026 view all
161.210400

Craftsman Multimeter Owner's manual (File: PDF, 30-09-2026)

64 4.93 Mb 932 178 30-09-2026 view all
82354

Craftsman 82354 User Manual (Owner's manual), @6S274Q

32 0.86 Mb 293 62 01-07-2026 view all
82140

82140 (Multimeter ePDF User Manual, #8VS5CH)

43 1.11 Mb 711 157 15-09-2026 view all
82312

Craftsman 82312 User Guide (Owner's manual), @IBVV4I

46 1.3 Mb 1435 244 24-05-2026 view all