NEUTRIK powerCON TRUE1 Operating & Assembly Instruction
Text of the manual
the chuck over
the cable.
Prepare
the cable as
shown.
D
B. ASSEMBLY INSTRUCTION
A. OPERATING INSTRUCTION
Application:
The power
TRUE1 system is certified as connector with breaking cap
ity according IEC
CON
ac
60320, VDE
It is intended for use as
It
0625.
appliance couplers and interconnection couplers.
serves to supply power to
an appliance and from an appliance to another equipment.
To be installed by
qualified person only.
Connector Assignment:
NAC3PX
NAC3MPX
NAC3FPX
NAC3FPX-ST
20
250
P S
E
JET
20
250
P S
E
JET
16
250
20
250
NAC3MX-W
20
250
P S
E
JET
16
250
20
250
NAC3MX-W
20
250
P S
E
JET
Power IN
Power OUT
Power IN
Power OUT
[0.32"]
8 mm
[
0.787”]
2
mm
0
[
0.9”]
PE 23 mm
NAC3MX-W
(Plug connector)
NAC3FX-W
(Connector)
NAC3FX-W
(Connector)
NAC3MX-W
(Plug connector)
Separate the
housing from the
bushing (cable
remain in bushing)
A
B
Insert cable into the
bushing and housing.
Note: “Apply cable
pulling lubricant to
cable jacket.”
C
20
250
P S
E
JET
16
250
20
250
NAC3MX-W
Approval based:
Rating:
Cable Type:
Strain Relief:
Cable O.D.:
VDE
EN 60320-1/EN60320-2-2
250 V ac / 16 A
H05VV-F3G 1.0 mm , Length max. 2 m
2
H05VV-F3G 1.5 - 2.5 mm
2
H07RN-F3G 1.5 mm
2
White chuck
6.0 - 12.0 mm
UL
UL 498 / CSA C22.2 No. 182.3
250 V ac / 20 A
SJTOW, SJOOW 3 x 12 AWG
White chuck
6.0 - 12.0 mm
C
[0.32"]
8 mm
[
0.787”]
2
mm
0
[
0.9”]
PE 23 mm
VDE (EN 60320-1/EN60320-2-2)
UL (UL 498 / CSA C22.2 No. 182.3)
40 - 50 mm
APPLIANCE INLET
APPLIANCE OUTLET
APPLIANCE INLET - OUTLET
COMBINATION
Draft. Nr.: BDA
Update:
380
13.07.2016
Data subject to change without prior notice.
201
5 NEUTRIK . ALL RIGHTS RESERVED.
NEUTRIK are registered trademark.
I
I
©
®
®
NEUTRIK AG
T:
F:
LI
+423 / 237 24 24
+423 232 53 93
/
NEUTRIK USA Inc.
T:
F:
USA
+1 704 / 972 3050
+1 704 438 9202
/
NEUTRIK
(UK Ltd.
)
T:
F:
UK
+44 1983 / 811 441
+44 1983 811 439
/
NEUTRIK Vertriebs GmbH
T:
F:
DE/NL/AT/DK
+49 8131 / 280 890
+49 8131 280 830
/
NEUTRIK France
FR
T:
F:
+33 1 4131 6750
+33 1 4131 0511
/
/
NEUTRIK Tokyo Ltd.
JP
T:
F:
+81 3 3663 4733
+81 3 3663 4796
/
/
NEUTRIK Hong Kong Ltd.
T:
F:
HK
+852 2687 6055
+852 2687 6052
/
/
NEUTRIK India Pvt. Ltd.
IND
T:
F:
+
+91 22 26163 540
91/982 05 43 424
/
ASSEMBLY INSTRUCTION
powerCON TRUE1
I
R
20
250
P S
E
JET
16
250
20
250
NAC3MX-W
20
250
P S
E
JET
16
250
20
250
NAC3MX-W
Torque Value 0.7 Nm
5.
Torque Value 2.0Nm
PRESS FIRMLY
Torx size
T8
1.
2.
4.
Wrench size
13 mm
6.
3.
Important:
Push and turn simultaneously.
FOR DISASSEMBLY - OPEN TWIST LOCK!
1.
Press with screw driver to unlock
Turn bushing 360°.
2.
Repat step 1 + 2 until bushing is unscrewed.
3.
1.
2.
CAUTION
To ensure protection
category, do not expose the
connection to bending forces
(e.g. do not attach loads to
the cable, no free-dangling
cable windings etc.).
LIECHTENSTEIN
20
250
P S
E
JET
G
E
F
Important:
Align r
ubber key
latch.
and
Insert the wires into the terminals and fasten the
screw with Torx size T8.
Wiring
VDE
UL
black
L
brown
�
white
N
blue
�
green/yellow
green
�
Slide the chuck onto the insert (1) and then both
together into housing (2).
Important: Align the chuck
and insert by
positioning the nose into
keyway.
the
Slide the bushing up the cable
and tighten it
with
the tool as shown.
Important: Yellow O-ring to hide to achieve IP
protection (6).
(Tool available: Art. No. HTAC)
FORCE
SAFETY WARNING
For safety and certification reasons the connector must be
replaced in case of any broken parts or serious damage.