NEUTRIK powerCON TRUE1 Operating & Assembly Instruction

Text of the manual

the chuck over

the cable. Prepare the cable as shown. D B. ASSEMBLY INSTRUCTION A. OPERATING INSTRUCTION Application: The power TRUE1 system is certified as connector with breaking cap ity according IEC CON ac 60320, VDE It is intended for use as It 0625. appliance couplers and interconnection couplers. serves to supply power to an appliance and from an appliance to another equipment. To be installed by qualified person only. Connector Assignment: NAC3PX NAC3MPX NAC3FPX NAC3FPX-ST 20 250 P S E JET 20 250 P S E JET 16 250 20 250 NAC3MX-W 20 250 P S E JET 16 250 20 250 NAC3MX-W 20 250 P S E JET Power IN Power OUT Power IN Power OUT [0.32"] 8 mm [ 0.787”] 2 mm 0 [ 0.9”] PE 23 mm NAC3MX-W (Plug connector) NAC3FX-W (Connector) NAC3FX-W (Connector) NAC3MX-W (Plug connector) Separate the housing from the bushing (cable remain in bushing) A B Insert cable into the bushing and housing. Note: “Apply cable pulling lubricant to cable jacket.” C 20 250 P S E JET 16 250 20 250 NAC3MX-W Approval based: Rating: Cable Type: Strain Relief: Cable O.D.: VDE EN 60320-1/EN60320-2-2 250 V ac / 16 A H05VV-F3G 1.0 mm , Length max. 2 m 2 H05VV-F3G 1.5 - 2.5 mm 2 H07RN-F3G 1.5 mm 2 White chuck 6.0 - 12.0 mm UL UL 498 / CSA C22.2 No. 182.3 250 V ac / 20 A SJTOW, SJOOW 3 x 12 AWG White chuck 6.0 - 12.0 mm C [0.32"] 8 mm [ 0.787”] 2 mm 0 [ 0.9”] PE 23 mm VDE (EN 60320-1/EN60320-2-2) UL (UL 498 / CSA C22.2 No. 182.3) 40 - 50 mm APPLIANCE INLET APPLIANCE OUTLET APPLIANCE INLET - OUTLET COMBINATION

Draft. Nr.: BDA

Update: 380 13.07.2016 Data subject to change without prior notice. 201 5 NEUTRIK . ALL RIGHTS RESERVED. NEUTRIK are registered trademark. I I © ® ® NEUTRIK AG T: F: LI +423 / 237 24 24 +423 232 53 93 / NEUTRIK USA Inc. T: F: USA +1 704 / 972 3050 +1 704 438 9202 / NEUTRIK (UK Ltd. ) T: F: UK +44 1983 / 811 441 +44 1983 811 439 / NEUTRIK Vertriebs GmbH T: F: DE/NL/AT/DK +49 8131 / 280 890 +49 8131 280 830 / NEUTRIK France FR T: F: +33 1 4131 6750 +33 1 4131 0511 / / NEUTRIK Tokyo Ltd. JP T: F: +81 3 3663 4733 +81 3 3663 4796 / / NEUTRIK Hong Kong Ltd. T: F: HK +852 2687 6055 +852 2687 6052 / / NEUTRIK India Pvt. Ltd. IND T: F: + +91 22 26163 540 91/982 05 43 424 / ASSEMBLY INSTRUCTION powerCON TRUE1 I R 20 250 P S E JET 16 250 20 250 NAC3MX-W 20 250 P S E JET 16 250 20 250 NAC3MX-W Torque Value 0.7 Nm 5. Torque Value 2.0Nm PRESS FIRMLY Torx size T8 1. 2. 4. Wrench size 13 mm 6. 3. Important: Push and turn simultaneously. FOR DISASSEMBLY - OPEN TWIST LOCK! 1. Press with screw driver to unlock Turn bushing 360°. 2. Repat step 1 + 2 until bushing is unscrewed. 3. 1. 2. CAUTION To ensure protection category, do not expose the connection to bending forces (e.g. do not attach loads to the cable, no free-dangling cable windings etc.). LIECHTENSTEIN 20 250 P S E JET G E F Important: Align r ubber key latch. and Insert the wires into the terminals and fasten the screw with Torx size T8. Wiring VDE UL black L brown � white N blue � green/yellow green � Slide the chuck onto the insert (1) and then both together into housing (2). Important: Align the chuck and insert by positioning the nose into keyway. the Slide the bushing up the cable and tighten it with the tool as shown. Important: Yellow O-ring to hide to achieve IP protection (6). (Tool available: Art. No. HTAC) FORCE SAFETY WARNING For safety and certification reasons the connector must be replaced in case of any broken parts or serious damage.

Other Cables and connectors Manuals