Key Pages of Document
2. Note .............................................................................................................. 3 3. Instrument Inspection ..................................................... ...
operation. Follow the instructions precisely as described herein. The instruction manuals on our website www.kobold.com are always for currently manufactured version of our products. Due to technical changes, the instruction manuals available o ...
The Kobold URM model flowmeter/monitor works on the basis of the suspended float principle. It is used for measuring the flow rates in closed pipe line systems. The medium flows from below through a glass measuring cone that gets wider on top. Thus, the float is raised and indicates the respective flow rate on t ...
7.1 Inductive switch (option) • Make sure that the supply wires are de-energized. • housing. 8. Operation In order to initialise the inductive switch function, it is essential that the float activates the contact once in each direction. Adjustment of limit-values The switch-point can be adjusted to the des ...
free. If deposits form on the inner housing or parts, periodic cleaning of the unit is recommended. Remove the units from the piping with a suitable tool; clean the flow meter with a suitable cleaning agent or make use of an ultrasonic bath. ...
Installation position: vertical Accuracy class: 4 acc. to VDI Max. temperature: 100°C (65°C for PVC) Max. pressure: 01H (L)…37H (L) 16 bar 43H…57H 12 bar 43L…55L 10 bar 63H…65H 8 bar 63L…65L 6 bar Calibration conditions: water: 20°C, air: 20°C, air pressure: 1.013 bar abs. Ambient temperature: - ...
Model Material combi- nation Instru- ment length Measuring range Pressure loss [mbar] Thread connection3) Contacts1) water [l/h] air [Nm3/h] female male URM- 33 55 992) 210 mm 01H = 0.25…2.5 01L = 0.0032…0.032 6 I2 I3 = G ¼ = G 3⁄8 G2 G3 = G ¼ = G 3⁄8 00 = no contact 03H = 0.4…4 03L = 0.008…0.08 6 05H = 0 ...
Model H [mm] A [mm] ¼" 3⁄8" ½" ¾" 1" 1 ¼" 1 ½" 2" 2 ½" 3" URM-xx 0... 210 29,5 F/M F/M - - - - - - - - URM-xx 1... 360 F/M F/M -/M - - - - - - - URM-xx 2... 40,0 - F/M F/M -/M - - - - - - URM-xx 3... 49,5 - - F/M F/M -/M - - - - - URM-xx 4... 440 62,0 - - - F/M ...
We, KOBOLD Unirota Kft. Nyíregyháza Hungary, declare under our sole responsibility that the product: Variable area flow meter Model: URM-… to which this declaration relates is in conformity with the standards noted below: EN IEC 63000:2018 Technical documentation for the assessment of electrical ...
⚠️ Download Safety
The Measuring Instruments Operating instructions manual (11 pages) is completely safe to download (last scan date: 10/08/2026).
Related PDF Instructions for Kobold URM:
-
Kobold MAS Series Measuring Instruments Instruction manual, 54 pages
-
Kobold LNK Switch Operating instructions manual, 15 pages
-
Kobold DRS Series Measuring Instruments Operating instruction, 15 pages
-
Kobold SWK Measuring Instruments Operating instructions manual, 9 pages
-
Kobold NWS Switch Operating instructions manual, 25 pages
-
Kobold KFF Measuring Instruments User instructions, 9 pages