94656 2 11/20

2 intimus Auditor Pro Operator Manual Typ/Type: 349 GB Operating instructions (page 3 - 12) Before operating, please read the Operating Instructions! ...

94656 2 11/20

GB 3 Auditor Pro - Operator Contents 1 Safety Information  . . . . . . . . . . . . . . . 3 2 Overview  . . . . . . . . . . . . . . . . . . . . . . . . 3 2.1 Administrator Setup  . . . . . . . . . . . . . . . . . . . . . . . 3 2.2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.3 Storage Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.4 Verification Processing Options . . . . . . . . . . . . . 4 2.5 Input devices  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3 Getting Started with Auditor Pro  . . . . . . . . . . . . ...

94656 2 11/20

Translation of the Original Operation Manual Übersetzung der Originalbetriebsanleitung GB 4 The Auditor Pro captures JPG images of the erased hard drive and collects information about the degauss and crush cycle. Auditor Pro creates Certificates of Erasure and De- struction. The intimus Auditor Pro comes equipped with USB and Ethernet ports allowing for direct prin- ting, exporting to USB devices including optical & thumb drives, and transferring to the network via FTP. It is easy and convenient to download the CSV data- base and JPG images, or to print or create PDF Certi- ficates of Erasure and Destruction directly from the Auditor Pro ...

94656 2 11/20

GB 5 Auditor Pro - Operator 4 Witness Login Step 1: LOGIN Screen � Enter your User ID � Enter your Password � Press the LOGIN button Step 2: Main Menu Screen � Press “WITNESS” Step 3: Witness Login Screen � Enter WITNESS ID � Enter witness password � Press LOGIN 5 Add Location or Job# Step 1: Main Menu Screen � Select LOCATION Step 2: Location Screen � Enter the name of your location in LOCATION field � Enter job number or select previous job # from drop down arrow in JOB field � Press SAVE ...

94656 2 11/20

Translation of the Original Operation Manual Übersetzung der Originalbetriebsanleitung GB 6 6 Configure Auditor Pro Sys- tem Step 1: Main Menu Screen � Press CONFIGURE SYSTEM Step 2: Login/Shut down Screen � Select your Auditor Pro unit[s] (selected unit[s] button[s] will be highlighted) � Press SAVE 7 Degaussing and Destroy- ing with Auditor Pro Degauss only steps 1-4 & 8 • Degauss and Destroy steps 1-8 Step 1: Main Menu Screen � Press DATA ENTRY Step 2: Media � Enter media serial number using scanner or input manually � If desired, input INCIDENT NUMBER � Press NEXT Step 3: Insert Media and Degauss � Insert media in ...

94656 2 11/20

GB 7 Auditor Pro - Operator Step 4a: Image Capture (20000S, 20000, 8000S series) � When degauss cycle is complete, open drawer and wait � Auditor Pro automatically captures an image of the degaussed media � If only degaussing, go to step 8 Step 4b: Image Capture (9000 series) � When the degauss cycle is complete, media will be released into image capture device � The Auditor Pro automatically captures an image of the degaussed media � If only degaussing, go to step 8 Step 5: Image Verification � Verify the clarity of the image � If acceptable, press ACCEPT and remove media � If the image is blurry, press REJECT and re ...

94656 2 11/20

Translation of the Original Operation Manual Übersetzung der Originalbetriebsanleitung GB 8 8 Destroying with 240/360 Crusher / 360 Destroyer Step 1: Media � Enter media serial number using scanner or input manually � If desired, input INCIDENT NUMBER � Select YES or NO to capture after crush image � Select SSD if you are destroying an SSD using the SSD-1 � Press NEXT Step 2: Before Crush Image Capture � Place media on imaging platform � Press OK to capture BEFORE CRUSH image Step 3: Image Verification � Verify the clarity of the image � If acceptable, press ACCEPT and remove media � If the image is blurry, press REJE ...

94656 2 11/20

GB 9 Auditor Pro - Operator 9 Solid-State Media Destruc- tion Verification Auditor Pro is factory set to take before and after ima- ges of SSD media. Instructions to change these set- tings are in the Administrator Manual. Step 1: Data Entry - SSD � Press SSD � Enter SSD serial number using scanner or input manually � If desired, input INCIDENT NUMBER � Press NEXT Step 2: Before Crush Image Capture � Place media in the degausser drawer or imaging platform � Press OK to capture BEFORE CRUSH image � Note: images of solid-state media is not possible when using the 9000 series Step 3: Before Crush Image Verification � Verify ...

94656 2 11/20

Translation of the Original Operation Manual Übersetzung der Originalbetriebsanleitung GB 10 10 Logging out and powering down the system Step 1: Main Menu Screen � Go to the menu bar and press LOGOUT to end your session Step 2: Power Down � Press the power button � The Auditor Pro will automatically power down � Press POWER icon on the individual unit(s) to turn off the degausser/destroyer 11 Connecting Auditor Pro to a Degausser or Destroyer af- ter turning on Auditor Pro Step 1: Connection cable � Connect Auditor Pro connection cable to degaus- ser/destroyer Step 2: Main Menu � Press CONNECT ...

94656 2 11/20

GB 11 Auditor Pro - Operator 12 Focusing Camera Focusing Camera � Place hard drive in media drawer/imaging plat- form with serial number label facing up (do not close drawer) � Select ADJUST CAMERA from Auditor Pro main menu � You will see the camera view on the Auditor Pro screen � Use the knob on the camera to adjust the focus Focusing 9000 series Camera � Detach Image Capture device from 9000 series by sliding towards you � Place a hard drive inside of the device � Select ADJUST CAMERA from Auditor Pro main menu � The view from the camera will appear on the Au- ditor Pro screen � Reach in from back side to adjust came ...

94656 2 11/20

Translation of the Original Operation Manual Übersetzung der Originalbetriebsanleitung GB 12 14 Disposal of the machine Always dispose of the machine at the end of its service life in an environmentally responsible way. Do not toss any part of the machine or its packaging into the garbage. 15 Technical Data Auditor Pro Power Supply: 90-240 VAC, 47-440 Hz Power Consumption: 15 W Storage Capacity: 16 GB Fuse: 250 VAC H3, 15 A Weight: 1,8 kg Dimensions (H x D x W): 6,3 x 16,7 x 24,3cm ...

94656 2 11/20

Dieses Papier ist aus 100 % Altpapier ohne optische Aufheller hergestellt. This paper made from 100 % unbleached recycled paper. Papier recyclable à 100 %. International Network Germany intimus International GmbH Bergheimer Straße 6-16 88677 Markdorf / Bodensee   +49 (0) 7544 60-0 [email protected] North America intimus North America 251 Wedcore Avenue Wabash, IN 46992   (800) 775 2122 [email protected] P .R . China intimus International Trading (Beijing) Limited Room 260D, C Building Guojigang No.E-2 Dong San Huan Bei Road, Chaoyang District, Beijing 100027, PRC   +86 (0) 10 84 47 10 71 / 72 / 73 info@intimus ...

Industrial Equipment PDF Instructions

Grundfos MMS Series Installation and operating instructions manual
Grundfos MMS Series
27.07.2026 28 pages

MS, MMS Installation and operating instructions GRUNDFOS INSTRUCTIONS Other languages http://net.grundfos.com/qr/i/96163721 www.motralec.com / [email protected] / 01.39.97.65.10

Lippert Ground Control 3.0 Installation manual
Lippert Ground Control 3.0
11.04.2026 18 pages

Rev: 06.26.2018 Ground Control® 3.0 LCD OEM Ground Control® 3.0 4 Point and 6 Point OEM INSTALLATION MANUAL (For systems installed after June 1, 2018)

Incra Fence System Owner's manual
Incra Fence System
25.07.2026 4 pages

1 • Before using the INCRA Fence System and Right Angle Fixture, carefully read and follow all of the instructions and safety information in this manual. • Always turn off the power and make sure that the bit or blade is fully stationary before moving any

GSi RSG1212GM-X21 Installation manual
GSi RSG1212GM-X21
09.05.2026 28 pages

PNEG-2023 Metric In-Line Mount and Cross-Cut Mount Flush Style Intermediate Discharge Gates Installation Manual PNEG-2023 Version: 1.0 Date: 01-07-16