LELY COSMIX S Installation And Operator's Manual
Read Online
Read the LELY COSMIX S Installation And Operator's Manual online using the built-in PDF viewer.
Text of the manual
Installation and Operator Manual
5.2309.8509.0 A
EN – English Original
LELY COSMIX S
Concentrate Feeder
TRADEMARKS, COPYRIGHT AND DISCLAIMER
1
TRADEMARKS, COPYRIGHT AND DISCLAIMER
Lely, Astronaut, Astri, Atlantis, Attis, AWS, C4C, Calm, Caltive, Commodus,
Compedes, Cosmix, Discovery, F4C, Fertiliner, Gravitor, Grazeway,
Hibiscus, Hubble, Juno, L4C, Lely Center, Lelywash, Lotus, Luna, Nautilus,
Orbiter, Quaress, Qwes, SAE, Shuttle, Splendimo, Storm, T4C, Tigo, Vector,
Viseo, Voyager, Walkway and Welger are registered trademarks of the
Lely Group.
The right of exclusive use belongs to the companies of the Lely Group. All
rights reserved. The information given in this publication is provided for
information purposes only and does not constitute an offer for sale.
Certain products may not be available in individual countries and
products supplied may differ from those illustrated. No part of this
publication may be copied or published by means of printing,
photocopying, microfilm or any other process whatsoever without prior
permission in writing by Lely Holding S.à r.l. Although the contents of this
publication have been compiled with the greatest possible care, Lely
cannot accept liability for any damage that might arise from errors or
omissions in this publication.
The English language manual is the original manual. Translations into
other languages use the English language manual as the source
document. Lely accepts no liability for discrepancies between the original
English language manual and versions in other languages. If there is a
conflict over the content and accuracy of any translated manual, the
English language manual is the authority document.
Copyright © 2015 Lely Industries N.V.
All rights reserved
Lely Industries N.V.
Cornelis van der Lelylaan 1
3147 PB Maassluis
the Netherlands
Phone: +31 (0)88 1228221
Fax: +31 (0)88 1228222
Website: www.lely.com
LIST OF INCLUDED AMENDMENTS
1
LIST OF INCLUDED AMENDMENTS
No:
Issue Date
(yy/mm)
Chapter(s)
Remarks
3
15/07
All
•
Long distance (LD) tag functionality added: machine
5.2309.0040.x
•
Installation of the rear fences changed
•
Adjustment of the photocell (H/HR models) added
•
Feed presence sensor removed
•
Pressure reducer added to control unit
•
Several other minor updates
2
11/06
3
Capacity adjusted
1
11/01
3
Dimensions adjusted
4
Descriptions feed presence sensor and Qwes leg ID reader
added
Operation section rewritten
5
Installation procedures feed presence sensor and Qwes leg ID
reader added
8
Adjustment procedures Qwes leg ID reader added
Glossary of
Terms
Terms added
10/04
Initial issue
Excluded from this warranty are any cost or expenses due to:
•
Abnormal use of the equipment which is not according to the
specifications stated in the Operator Manual or handled during the
Operators Service and Maintenance Certification program.
•
The result of any intervention by technicians other than Lely service
technicians or technicians who have Lely’s approval to perform certain
duties.
•
Incidents such as freezing, ice, fire, flood, inundation or any other
form of excessive water, lightning.
•
Defect of the electrical system or grounding.
•
Use of compressed air that does not meet the quality standards set by
Lely Industries.
•
Damage to the electrical system as a result of vermin or the like.
•
For USERS that have followed the Operators Maintenance and Service
Certification: Any damage resulting from abnormal use of the
equipment which is not according to the specifications stated in the
Operator Technical Training Manual is not covered by the warranty
scheme.
Warranty does not apply to consequential damage which does not
involve the machine itself.
All systems are tested. However in the event of a malfunction Lely cannot
be held responsible for consequential damage.
This manual contains the information necessary for the correct
installation and operation of a COSMIX S Concentrate Feeder.
Study and understand this information thoroughly before configuration
of the COSMIX S. Failure to do so could result in damage to equipment.
Please consult your local Lely service provider if you do not understand
the information in this manual, or if you need additional information.
All information in this manual has been compiled with care. Lely shall not
be liable for errors or faults in this manual. The recommendations are
meant to serve as guidelines. All instructions, pictures and specifications
in this manual are based on the latest information that was available at
the time of publication. Your COSMIX S may comprise improvements,
features or options that are not covered in this manual.
Applicability
The table below shows the type numbers of COSMIX S for which this
manual is applicable.
Model designation
Model
Type number
COSMIX S Concentrate Feeder Qwes ISO ACT neck
5.2309.0000.X
COSMIX S Concentrate Feeder Qwes H/HR
5.2309.0010.X
COSMIX S Concentrate Feeder Qwes ISO ACT leg
5.2309.0020.X
COSMIX S Concentrate Feeder Qwes H/HR-LD
5.2309.0040.X
Software version
The description, operation and procedures in this manual are based on
the following software versions:
•
T4C version 3.1.3 or higher
•
E-Link version 1.08R or higher
•
ADS 3830 pcb; CMv01.05.25 or higher.
Standard Torque Loading of Parts
All the nuts, bolts and screws used on the COSMIX S Concentrate Feeder
are torque tightened to standard torque loadings applicable to the
construction materials used.
If a part has a non-standard torque loading, it is specified in the
applicable part of the manual.
The Type and Serial Number Plate is attached to the control box of the
COSMIX S Concentrate Feeder, on the top. Always include the type and
serial number of your concentrate feeder when you contact your local
Lely service provider or order spare parts.
Figure 1. Type and Serial Number Plate
We suggest you complete the table below with the type and serial
numbers of your concentrate feeder. This makes sure you can easily find
the information.
Type number
Serial number
Maintenance Authorization
Only technicians certified by Lely Industries are authorized to
do maintenance on the COSMIX S, except for the maintenance
done by the operator as indicated in the Operator Manual.If
people who are not certified by Lely Industries do maintenance
on the COSMIX S, the warranty on the COSMIX S becomes
invalid.
Before a technician does maintenance on a COSMIX S, the owner must
examine the service pass of the technician and make sure the technician
is currently certified to do maintenance on the COSMIX S.
At the end of each visit, all work done on the COSMIX S must be written
in the logbook and the logbook must be signed by the certified
technician. The logbook must always be kept near the COSMIX S for the
entire life of the product. The information in the logbook must include:
•
The maintenance done
•
The date of the maintenance
•
The name of the technician
•
The certification number of the technician.
All the technicians certified by Lely Industries have completed an
approved training program, and passed written and practical
examinations during and at the end of the training program. The
training is given by a product specialist. The examinations are done under
supervision of a master product specialist and include troubleshooting
and corrective maintenance of the COSMIX S.
There are five certification levels:
•
Installation Technician (certification valid for two years)
•
Service Engineer (certification valid for two years)
•
Senior Service Engineer (certification valid for two years)
•
Product Specialist (certification valid for one year)
•
Master Product Specialist (certification valid for one year).
During training, a trainee is permitted to work for up to a maximum of
six months under close supervision of a certified technician. A trainee can
do work on the milking robot can only in the presence of a certified
technician.
When the training program is completed successfully, Lely issue a
certificate and a service pass to the technician. The service pass contains
the following information:
•
The name of the technician
•
A photograph of the technician
•
The certification number of the technician
•
The date of expiry of the certification.
Contact Number Local Service Provider
We suggest you write the telephone number and email address of your
local service provider contact in the table below. This makes sure you can
easily find the information.
Telephone number
email address
Table of Contents
v
Table of Contents
1
INTRODUCTION
........................................................................................1-1
2
SAFETY
.................................................................................................2-1
2.1
Introduction
.................................................................................... 2-1
2.2
Signal Icons
..................................................................................... 2-1
2.3
Safety Instructions
............................................................................. 2-2
2.3.1
General Safety
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.3.2
Electrical Safety
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.3.3
Installation Safety
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.3.4
Operating Safety
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.3.5
Maintenance Safety
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.4
Safety Decals
................................................................................... 2-4
2.4.1
Safety Decal Messages
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.4.2
Installation of Safety Decals
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.4.3
Maintenance of Safety Decals
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
3
SPECIFICATIONS
.......................................................................................3-1
3.1
Dimensions and Weight
....................................................................... 3-1
3.2
Control Unit
.................................................................................... 3-1
3.3
Cow Identification Readers
................................................................... 3-1
3.4
External Requirements
........................................................................ 3-1
4
DESCRIPTION AND OPERATION
.....................................................................4-1
4.1
Introduction
.................................................................................... 4-1
4.2
Component Description
....................................................................... 4-5
4.2.1
Frame and Fencing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.2.2
Feed Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
4.2.3
Control Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
4.2.4
Cow Identification (ID) Readers
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
4.3
Operator Interface
........................................................................... 4-13
4.3.1
T4C Farm Management Software
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-13
4.4
Service Interfaces
............................................................................. 4-14
4.4.1
The E-Link Manual Controller
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
4.4.2
Menu Structure E-Link
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15
4.4.3
Cosmix Service Interface
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20
4.5
Operation
..................................................................................... 4-20
4.5.1
Identification
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20
4.5.2
Feeding
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
4.5.3
Interaction between the COSMIX S Components
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
5
INSTALLATION
.........................................................................................5-1
Table of Contents
5.1
Introduction
.................................................................................... 5-1
5.2
Preparation
..................................................................................... 5-1
5.2.1
List of Supplied Parts
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.2.2
Preparation by the Owner
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.2.3
Preparation by Lely
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
5.2.4
Position of the Cosmix
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
5.3
Install the COSMIX S
........................................................................... 5-4
5.3.1
Preparation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
5.3.2
Install the Side Fences on the Portals
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
5.3.3
Level, square and tighten the Fences
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
5.3.4
Install the Portals on the Floor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
5.3.5
Install the Control Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10
5.3.6
Install the Front Plate
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12
5.3.7
Install the Feed Bin and the Feed Hopper on the Front Plate
. . . . . . . . . . . . . . . . . . . . . . . . . 5-15
5.3.8
Install the Rear Fences
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17
5.3.9
Install the Restraining Bracket
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19
5.3.10
Install a Qwes leg ID Reader and a Floor Antenna
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20
5.4
Connect the COSMIX S
....................................................................... 5-25
5.4.1
Connect the Air Tubes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25
5.4.2
Connect the ID-Reader Cable
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-26
5.4.3
Install the Earthing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27
5.4.4
Prepare the Network Cable
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27
5.4.5
Install a Type 1 Network Connector
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-28
5.4.6
Install a Type 2 Network Connector
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
5.4.7
Install the Network Cable on an Earthing Clamp
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-34
5.4.8
Remove or install the Covers from the Feed Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-35
5.5
Setup the COSMIX S
......................................................................... 5-35
6
OPERATING INSTRUCTIONS
.........................................................................6-1
6.1
List Details about the Rest Feed
.............................................................. 6-1
6.2
List a Feed Overview
........................................................................... 6-1
6.3
List a Device Intake Overview
................................................................. 6-2
7
MAINTENANCE
........................................................................................7-1
8
TEST AND ADJUSTMENT
.............................................................................8-1
8.1
Introduction
.................................................................................... 8-1
8.2
Connect or Remove the E-Link Manual Controller
.......................................... 8-1
8.3
Set the Network Settings
...................................................................... 8-1
8.3.1
Set Defaults
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1
8.3.2
Set the Device Address of the Cosmix
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
8.3.3
Set the T4C Device Address
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
8.3.4
Set the IP-address
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Table of Contents
vii
8.4
Make Basic Software Settings
................................................................. 8-3
8.4.1
Display the Software Version
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
8.4.2
Reset to the Default Settings
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
8.4.3
Set the Time
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
8.4.4
Make the Photocell Active
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4
8.4.5
Calibrate the Valves
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4
8.4.6
Set the Portion Size
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5
8.4.7
Adjust the Portion Size
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5
8.4.8
Clear all Tables
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5
8.5
Test the Operation of the COSMIX S
......................................................... 8-6
8.5.1
Test the Time Setting
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
8.5.2
Display Real Time Information
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
8.5.3
Test the Tag-ID
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
8.5.4
Test the Dosing Units
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7
8.6
Adjust the Floor Antenna Signal (Qwes leg models only)
.................................. 8-7
8.7
Adjust the Photoelectric Sensor
............................................................ 8-10
8.8
Adjustments in the T4C Software
........................................................... 8-13
8.8.1
Add the COSMIX S to T4C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13
8.8.2
Add a Feed Type
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13
8.8.3
Set the Feed Speed
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-14
8.9
Adjustments with the Service Interface
.................................................... 8-14
8.9.1
Calibrate the Valves with the Service Interface
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-14
9
TROUBLESHOOTING
..................................................................................9-1
9.1
Troubleshooting Table
......................................................................... 9-1
9.2
Recovery Procedures
........................................................................... 9-1
9.2.1
Make Sure the Cow has Feed Credit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1
9.2.2
Make Sure the Cow Number is less than 32000
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1
9.2.3
Clean the Dosing Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1
10
DIAGRAMS
........................................................................................... 10-1
10.1
Overview COSMIX S with One or Two Feed Hoppers
..................................... 10-1
GLOSSARY OF TERMS
The COSMIX S Concentrate Feeder supplies an exact portion of extra feed
to cows to realize their maximum milk production. The feed portion can
be a mixture of up to four different types of concentrates.
An electronic tag on each cow enables the system to identify the cow via
an unique number. There are three tag types:
•
Qwes H/HR for identification with an infrared ID reader
•
Qwes ACT for identification with an ISO ID reader
•
Qwes leg for identification with an ISO ID reader
The T4C (Time for Cows) farm management software has information
about each cow and adjusts the use quantity and mixture of the feed
based on this information.
In combination with the Astronaut milking robot a closed system of
milking and allocation of concentrates can be created.
The information in this manual is for farmers and technicians.
•
Farmers use the information to test and adjust the COSMIX S or to list
overviews
•
Technicians use the information to install and setup the COSMIX S.
The safety alert symbol identifies important safety messages on your
COSMIX S Concentrate Feeder and in the manual. When you see this
symbol, be alert to the possibility of personal injury or death. Follow the
instruction of the safety message.
Figure 2. Safety Alert Symbol
2.2
Signal Icons
Note the use of the signal words DANGER, WARNING and CAUTION with
the safety messages. The signal word for each message uses the following
guidelines:
Danger: indicates an imminently hazardous
situation that, if not avoided, will result in death or
serious injury.
Warning: indicates a potentially hazardous situation that, if
not avoided, could result in death or serious injury, and
includes hazards that are exposed when guards are removed.
Caution: indicates a potentially hazardous situation that, if not
avoided, may result in minor or moderate injury or product or
property damage.
Note: this shows extra information that may help the reader.
YOU are responsible for the SAFE operation and maintenance of your
concentrate feeder. YOU must make sure that you and anyone else who
is going to operate, maintain or work in the vicinity of the concentrate
feeder knows all the related SAFETY information in this manual.
YOU are the key to safety. Good safety practices protect you and the
people around you. Make these practices a working part of your safety
program. Make sure EVERYONE who operates, maintains or works near
the concentrate feeder obeys the safety precautions. Do not risk injury or
death by ignoring good safety practices.
•
COSMIX S owners must train operators before they operate the
concentrate feeder. This training must be repeated at least annually
•
The operator must read, understand and obey all safety and operating
instructions in the manual
•
A person who has not read and understood all safety and operating
instructions is not permitted to operate the concentrate feeder
•
Do not modify the equipment in any way. Unauthorized modification
may impair the function and/or safety and could affect the life of the
equipment, and persons
•
Only use approved spare parts, and make sure they are only installed
by authorized technicians.
2.3.1
General Safety
•
Read and understand the manual and all safety signs before you
connect power supplies to operate, maintain or adjust the COSMIX S
Concentrate Feeder
•
Only trained persons are permitted to operate the COSMIX S
Concentrate Feeder
•
A first-aid kit must be available near the COSMIX S Concentrate
Feeder. Store in a highly visible place
•
A carbon dioxide or foam fire extinguisher must be available near the
COSMIX S Concentrate Feeder. Store the fire extinguisher in a highly
visible place
•
Install all protective covers and guards before you operate the
COSMIX S Concentrate Feeder
•
Wear the correct protective clothing and equipment
•
Disconnect and isolate the electrical power supply, release pneumatic
pressure and wait for all moving parts to stop before you clean or do
maintenance on the concentrate feeder
•
Know the emergency medical center number for your area
•
Contact your nearest Lely service provider if you have any questions
•
Review safety related items with all operators frequently (annually).
Only an authorized electrician must install the electrical power supply
for the COSMIX S Concentrate Feeder
•
Make sure the electrical grounding of the electrical system and all
parts of the COSMIX S Concentrate Feeder meet the local rules and
regulations
•
Replace any damaged electrical lines, conduits, switches and
components immediately
•
Isolate the electrical power supply before you open the PCB box to
work on the electrical system.
2.3.3
Installation Safety
•
Read and understand the instructions in this manual
•
The concentrate feeder is not stable until it is correctly installed
•
Make sure it is correctly supported at all times during movement and
installation
•
Make sure the concentrate feeder is correctly installed.
2.3.4
Operating Safety
•
Read and understand the applicable manual and all safety signs
before you connect power supplies to operate, maintain or adjust the
COSMIX S Concentrate Feeder
•
Only trained persons are permitted to operate the COSMIX S
Concentrate Feeder
•
Disconnect and isolate the electrical power supply, release pneumatic
pressure and wait for all moving parts to stop before you clean or do
maintenance on the COSMIX S Concentrate Feeder
•
Install all covers and guards before you operate the COSMIX S
Concentrate Feeder
•
Keep hands, feet, hair and clothing away from all moving parts
•
Keep unauthorized persons, especially small children away from the
COSMIX S Concentrate Feeder at all times
•
Before the pneumatic pressure is supplied to the COSMIX S
Concentrate Feeder, make sure all parts are tight and that all hoses
and fittings are in good condition
•
Always be alert for unexpected movement of the cow. Cows can
transmit large forces to parts of the machine
•
Contact your nearest Lely service provider if you have any questions
•
Review safety related items with all operators frequently (annually).
2.3.5
Maintenance Safety
•
Read and understand the applicable manual and all safety signs
before you connect power supplies to operate, maintain or adjust the
COSMIX S Concentrate Feeder
Only trained persons are permitted to maintain the COSMIX S
Concentrate Feeder
•
Disconnect and isolate the electrical power supply, release pneumatic
pressure before you do work on the COSMIX S Concentrate Feeder
•
Take extreme care when you work near or with high-pressure
pneumatic systems. If possible, depressurize the system before you do
work on it
•
Wear protective clothing and safety goggles when you do work on
the pneumatic system
•
Make sure all covers and guards are installed when maintenance work
is complete.
2.4
Safety Decals
2.4.1
Safety Decal Messages
General safety messages appear in this safety messages section. Specific
safety messages are in applicable parts of this manual when potential
hazards may occur if the instructions or procedures are not followed.
2.4.2
Installation of Safety Decals
1.
Make sure that the installation surface is clean and dry.
2.
Make sure that the temperature of the mounting surface is not less
than 5 °C (41 °F).
3.
Find the correct position for the decal before you remove the
backing paper.
4.
Remove a small part of the cover paper.
5.
Put the decal in the correct position on the installation surface and
carefully push the small part of exposed adhesive surface of the
decal onto the installation surface.
6.
Slowly remove the cover paper and attach the rest of the decal to
the installation surface.
7.
Puncture small air pockets in the decal with a pin and use the cover
paper to smoothen the decal.
2.4.3
Maintenance of Safety Decals
Safety decals show important and useful information that will help you
to safely operate and maintain the machine.
Obey the instructions below to make sure that all the decals stay in the
correct position and condition.
•
Keep the safety decals clean and legible at all times. Clean the safety
decals with soap and water. Do not use mineral spirits, abrasive
cleaners or other similar agents that may damage the safety decals.
•
Replace safety decals that are missing or that are illegible.
•
Safety decals can be purchased from your local Lely service provider.
Dimensions and Weight
•
Height: 208.5 cm (82.1 in)
•
Length: 267.2 cm (105.2 in)
•
Width: 102.2 cm (40.2 in)
•
Weight: approx. 248 kg (547 lb)
•
Capacity feed hopper: 25 l (6.6 gal)
•
Portion size: approx. 60 g (2.1 oz), depending on the feed type
Refer to the Diagrams in chapter 10 for the complete dimensions of the
COSMIX S.
3.2
Control Unit
•
Pcb: ADS3830
•
Software version: CMv01.05.25 or higher
3.3
Cow Identification Readers
Life tags are not supported.
•
Qwes H/HR for identification with an infrared ID reader
•
Qwes ACT for identification with an ISO ID reader
•
Qwes leg for identification with an ISO ID reader
3.4
External Requirements
Pressurized air
•
Output pressure: 6 - 7,5 bar (87 - 109 psi)
•
Connection: 6 mm tube
Electrical power
•
100 - 240 VAC
Earthing
•
Earthing of the COSMIX S must comply with current earthing
regulations for barns (obey local rules and standards)
•
The earth wire must be connected to the earth point
•
An authorized electrician must approve the final electrical installation
(including earthing) and supply an official report that is given to the
Lely service provider before the installation is used
Warranty on electronics will not be given if the earthing is not
correctly installed.
T4C network
Network connection:
•
LAN CAT.5e Network cable, S-FTP 200 MHz (foil-screened twisted pair
with overall screening (copper braiding)) with steel RJ-45 connector
•
Maximum cable length: 100 m (109 yd) (use a switch if the distance is
more than 100 m (109 yd))
DESCRIPTION AND OPERATION
4-1
4
DESCRIPTION AND OPERATION
4.1
Introduction
The COSMIX S has the following main parts:
•
Frame and fencing
•
Feed hopper(s) (1 - 4)
•
Feed bin
•
Control unit
•
Cow identification reader.
The COSMIX S is installed in the barn.
The COSMIX S is connected to the T4C network.
The COSMIX S gets input from and sends output to the T4C Farm
Management software.
The following figures show the main components of the COSMIX S with
Qwes ACT, Qwes H/HR and Qwes leg identification.
DESCRIPTION AND OPERATION
Figure 4. Main components COSMIX S with Qwes ACT identification
KEY:
1. Feed hopper - 2. Control box - 3. Rear portal - 4. Restraining bracket - 5. Rear fences - 6. ID-reader - 7. Front portal - 8.
Feed bin - 9. Side fence
DESCRIPTION AND OPERATION
4-3
Figure 5. Main components COSMIX S with Qwes H/HR identification
KEY:
1. Feed hopper - 2. Control box - 3. Rear portal - 4. Restraining bracket - 5. Rear fences - 6. Front portal - 7. Feed bin - 8. Side
fence
DESCRIPTION AND OPERATION
Figure 6. Main components COSMIX S with Qwes H/HR-LD identification
KEY:
1. Feed hopper - 2. IR reader (External IDU 530) - 3. Control box - 4. Rear portal - 5. Restraining bracket - 6. Rear fences - 7.
Front portal - 8. Feed bin - 9. Side fence
DESCRIPTION AND OPERATION
4-5
Figure 7. Main components COSMIX S with Qwes leg identification
KEY:
1. Feed hopper - 2. Control box - 3. Rear portal - 4. Side fence - 5. Restraining bracket - 6. Rear fences - 7. EWA transformer -
8. Floor antenna mat - 9. Front portal - 10. Feed bin - 11. Side fence
4.2
Component Description
4.2.1
Frame and Fencing
The COSMIX S has the following frames and fences:
•
Front portal
•
Rear portal
•
Side fence (2×)
•
Restraining bracket.
The two side fences are connected to the front and the rear frame. The
restraining bracket prevents cows from being hindered by other cows
while eating.
DESCRIPTION AND OPERATION
4.2.2
Feed Unit
The feed unit is an assembly that has the following parts:
•
Feed hopper
•
Dosing unit
•
Feed funnel
•
Feed bin.
The feed unit can have 1 - 4 feed hoppers, each with a dosing unit.
All parts are installed on a plate.
4.2.2.1
Feed Hoppers
The COSMIX S has up to four feed hoppers. Each feed hopper has a feed
dosing unit that provides portions of concentrates.
In most cases the feed hoppers are filled by tube feeders that are
connected to silos.
Lely does not supply tube feeders and silos.
4.2.2.2
Dosing Unit
The dosing unit gives exactly the same (calibrated) volume each feed
portion. It has a cylinder that opens and closes the unit.
The amount of concentrate to be fed to a cow is based on calculations
made in the T4C farm management software.
The proportion of each feed type and the total amount that is fed can be
set per cow, group or herd.
4.2.2.3
Feed Funnel
The feed is dropped through the feed funnel into the feed bin.
4.2.2.4
Feed Bin
The feed bin is made of stainless steel.
4.2.3
Control Unit
The control unit controls the identification of cows and the supply of
feed.
The control unit on top of the COSMIX S has the following parts:
•
ADS 3830 pcb
•
Air valves
•
Photoelectric sensor (Qwes H/HR models only)
•
Infrared ID reader (Qwes H/HR models only)
•
Velos box (Qwes leg models only)
DESCRIPTION AND OPERATION
4-7
•
Power supply with safe life switch
•
Network switch (optional).
•
Air pressure reducer
4.2.3.1
ADS 3830 pcb
The ADS 3830 pcb (see figure 8 on page 4-8) controls the valves that
supply air to the cylinders of the feed dosing unit. The pcb is installed in
the control unit.
The control software that runs on the pcb communicates with the T4C
farm management software.
Connector J604 (9) is connected to the valves for the cylinders that move
the feed dosing units. Connector J602 (11) is connected to the
photoelectric sensor, if applicable.
The following table shows the connector/pin - cylinder combinations:
Connector
Pins
Cylinder
J604
Out1, gnd
Dosing Unit 1
Out2, gnd
Dosing Unit 2 (optional)
Out3, gnd
Dosing Unit 3 (optional)
Out4, gnd
Dosing Unit 4 (optional)
J602
In4, gnd
Photoelectric sensor (Qwes H/HR models
only)
DESCRIPTION AND OPERATION
Figure 8. ADS 3830 pcb
KEY:
1. Not used - 2. Not used - 3. Ethernet connector - 4. Infrared ID reader (Qwes H/HR models only) or Velos box (Qwes leg
models only) - 5. E-Link - 6. 24V power supply - 7. Valves dosing unit 5 (optional) - 8. Status indicator - 9. Valves dosing units
1–4 - 10. FSK pcb (Qwes ACT models only) - 11. Photoelectric sensor (Qwes H/HR models only)
4.2.3.2
Velos Box
In Qwes leg models, a velos box is installed to convert the analog
antenna signal to a digital signal that is appropriate for the ADS 3830
pcb.
The velos box is installed in the control unit.
4.2.3.3
Air Valves Block
The air valves are solenoid valves and supply pressurized air to the
cylinders of the feed dosing unit(s).
The air valves are installed on a valve terminal. A standard configuration
has one solenoid valve and five blanking plates. If an additional feed
funnel is installed, an additional air valve is also installed. The valves are
controlled by the ADS 3830 pcb.
4.2.3.4
Photoelectric Sensor
The photoelectric sensor has a housing that contains an emitting element
(infrared LED) and a receiving element (photodiode). It is installed on a
bracket on the base plate of the control unit.
The photoelectric sensor gets input when a cow is in the COSMIX S.
The photoelectric sensor sends output to the ADS 3830 pcb.
DESCRIPTION AND OPERATION
4-9
Figure 9. Control unit (Qwes ACT)
KEY:
1. Pressure reducer - 2. ADS 3830 pcb - 3. Network switch (optional) - 4. Power supply (ADS 3830 pcb) - 5. Safe life switch
(optional) - 6. Air valve - 7. E-Link connection - 8. Air valve block
DESCRIPTION AND OPERATION
Figure 10. Control unit (Qwes H/HR)
KEY:
1. Pressure reducer - 2. ADS 3830 pcb - 3. Network switch (optional) - 4. Infrared ID reader - 5. Photoelectric sensor - 6. Power
supply (ADS 3830 pcb) - 7. Safe life switch (optional) - 8. Air valve - 9. E-Link connection - 10. Air valve block
DESCRIPTION AND OPERATION
4-11
Figure 11. Control unit (Qwes H/HR-LD)
KEY:
1. Pressure reducer - 2. ADS 3830 pcb - 3. Network switch (optional) - 4. Photoelectric sensor - 5. Power supply (ADS 3830
pcb) - 6. Safe life switch (optional) - 7. Air valve - 8. E-Link connection - 9. Air valve block
DESCRIPTION AND OPERATION
Figure 12. Control unit (Qwes leg)
KEY:
1. Pressure reducer - 2. ADS 3830 pcb - 3. Velos box - 4. Network switch (optional) - 5. Power supply (ADS 3830 pcb) - 6. Safe
life switch (optional) - 7. Air valve - 8. E-Link connection - 9. Air valve block
4.2.4
Cow Identification (ID) Readers
4.2.4.1
Qwes ACT Cow ID Reader
The Qwes ACT cow identification system has two components:
•
The cow tag (Qwes ACT)
•
The ID reader (ISO).
The cow tag is installed on a collar on the neck of the cow.
The cow ID reader is a sealed plastic box with an internal antenna (MIMI).
The box is installed on a mounting plate that is installed on the front
plate under the feed bin. The data cable of the ID reader is connected to
the FSK pcb (10)(see figure 8 on page 4-8) on the ADS 3830 pcb.
4.2.4.2
Qwes H/HR Cow ID Reader
The Qwes H/HR cow identification system has two components:
•
The cow tag (Qwes H or Qwes HR)
DESCRIPTION AND OPERATION
4-13
•
The infrared ID reader.
The cow tag is installed on a collar on the neck of the cow.
The ID reader can be installed on two places:
1.
In the control unit (4)(see figure 11 on page 4-11) on top of the
COSMIX S
2.
In a metal housing (3)(see figure 6 on page 4-4) under the Control
unit on top of the COSMIX S.
It has the following components:
•
Xenon flash light
•
Infrared transmitter and receiver
•
Indicator LEDs for cow presence and data transfer
•
Pcb.
The transmitter, receiver and indicator LEDs are connected to the pcb, the
pcb is connected to the ADS 3830 pcb(see figure 8 on page 4-8).
4.2.4.3
Qwes ISO Leg Reader
The Qwes ISO leg reader has three components:
•
Floor antenna
•
EWA transformer
•
Velos box (VP1001)
The floor antenna mat (8)(see figure 7 on page 4-5) is installed on the
floor in between the front portal (9). The EWA transformer (7) is installed
on the front portal. The Velos box (VP1001) (3)(see figure 12 on page 4-
12) installed in the Qwes ISO leg control box on top of the COSMIX S. On
the side of the control box are cable glands. The CAN-bus cable of the
Velos box is connected to connector J608 on the ADS2412 PCB.
The floor antenna mat detects the signal from the Qwes ISO ACT leg tag.
The EWA transformer filters the identification signal from the antenna
signal and sends it to the Velos box. The Velos box converts the analog
signal to a digital (CAN-bus) signal for the ADS2412 PCB.
4.3
Operator Interface
The settings of the COSMIX S are made in the T4C Farm Management
software (T4C).
4.3.1
T4C Farm Management Software
The T4C software is used to:
•
Setup the COSMIX S
•
Get information about the food consumption
•
Set the amount of concentrate the COSMIX S supplies.
The T4C software receives data requests from the COSMIX S.
DESCRIPTION AND OPERATION
The T4C software sends data (new and updated) to the COSMIX S.
4.3.1.1
The T4C Window Explained
The T4C software is displayed in a Google Chrome window. The window
has the following parts:
•
Header
•
Navigation bar
•
Data page.
Figure 13. The T4C screen overview
KEY:
1. Header - 2. Navigation bar - 3. Data page
4.4
Service Interfaces
The COSMIX S has the following service interface:
•
E-Link Manual Controller
•
T4C Farm Management software
•
Cosmix Service Interface (web browser).
4.4.1
The E-Link Manual Controller
The E-Link Manual Controller controls and monitors the COSMIX S.
The E-link Manual Controller has an LCD display and nine buttons that
enable the user to give commands and change values in the COSMIX S.
The LCD display also shows reports and alarms.
The connector of the E-Link Manual Controller is on the front side of the
control unit.
DESCRIPTION AND OPERATION
4-15
The E-Link has the following buttons:
•
Soft buttons (1): confirm the action on the LCD display above the
applicable button
•
Start/Stop button (2): starts or stops an action
•
Enter button (4): open the selected function or the next menu screen
•
Menu button (5)
•
Arrow buttons (3 and 7): move the selector up/down, increase/
decrease a value by one
•
Escape button (6): return to the previous screen.
Figure 14. The E-Link Manual Controller
KEY:
1. Soft buttons - 2. Start or stop button - 3. Arrow down button - 4. Enter button - 5.
Menu button - 6. Escape button - 7. Arrow up button - 8. LCD display
4.4.2
Menu Structure E-Link
The main menu on the E-Link has the following items:
•
Version info
•
Settings
•
Network Settings
•
Testing
•
Setup.
An input selection on the E-Link is shown as a grey cross-hatched
block.
DESCRIPTION AND OPERATION
Figure 15. The E-Link menu structure
4.4.2.1
Version info
'Version info' displays information about the software installed on the
ADS 3830 pcb.
The menu displays the following items:
•
Software version
•
Time when the software was compiled
•
Date when the software was compiled
•
Version info of the ID-reader.
The software version is the current version number of the software
installed on the ADS 3830 pcb.
DESCRIPTION AND OPERATION
4-17
4.4.2.2
Settings
The menu 'Settings' is used to define basic settings that are necessary for
correct operation.
The menu has the following items:
•
Set defaults
•
Time
•
Imperial Units
•
Keep blocker open (Not used)
•
Photocell active
•
Weigh unit on (Not used)
•
Portion size1
•
Portion size2
•
Portion size3
•
Portion size4
•
Portion size5 (Not used)
•
CalibrateTagsActive
•
Cal. Tag1
•
Cal. Tag2
•
Cal. Tag3
•
Cal. Tag4
•
Cal. Tag5
•
Feedsensor Present (Not used).
Menu item 'Set defaults' resets the value of all items in this sub-menu to
the default values.
The menu item 'Time' displays the current time and date. The time and
date are automatically synchronized with the T4C software.
The menu item 'Imperial Units' is used to switch from display of metric
units to imperial units.
The menu item 'Keep blocker open' is only applicable for service
engineers.
In the IR version of the COSMIX S a photocell is installed to support the
ID-detector. The setting Photocell active is used to switch ON the
photocell (value 0 is OFF, value 1 is ON).
The menu item 'Weigh unit on' is not used.
The menu items 'Portion size1', 'Portion size2', 'Portion size3' or 'Portion
size4' are used to set the portion size of each dosing unit. By default the
portion sizes for feed types 1 to 4 are 61, 62, 63 and 64 grams. Menu item
'Portion size5' is not used.
DESCRIPTION AND OPERATION
The last portions fed can be less than the set ‘Dose portion’ to feed
exactly the actual balance of a cow.
The menu item 'CalibrateTagsActive' is used to switch ON or OFF the
calibration procedure.
The menu items 'Cal. Tag1' - 'Cal. Tag4' can be used to introduce a new
tag in T4C. 'Cal. Tag5' is not used.
4.4.2.3
Network Settings
The menu 'Network settings' is used to define basic network settings that
are necessary for correct operation.
The menu has the following items:
•
Set defaults
•
Dev addr Cosmix
•
Dev addr T4C
•
Dev addr CRS+
•
IP Address
•
ETH address.
The menu 'Set defaults' is used to restore all default network settings.
When the default settings are restored, the network address is also reset.
The correct network address must be set to use the COSMIX S.
The menu 'Dev addr Cosmix' is used to identify the COSMIX S in the T4C
network.
The recommended value is 11 for the first COSMIX S, 12 for the
second, and so on.
Menu item 'Dev addr T4C' sets the identification number of the T4C-
server. The default setting is 001.
Menu item 'Dev addr CRS+' sets the identification number of the CRS+.
The default setting is 151.
Menu item 'IP Address' sets the IP address of the COSMIX S, as used in the
T4C network.
Menu item 'ETH address' displays the ethernet (MAC) address of the ADS
3830 pcb.This address is fixed and can not be changed.
4.4.2.4
Testing
Menu 'Testing' displays information about the use of the COSMIX S, real-
time or non-real-time, and enables testing of some functions.
The menu has the following items:
•
Time
DESCRIPTION AND OPERATION
4-19
•
RealTimeInfo
•
Tag id
•
Valves/Blocker
•
IDC Power level
•
mbox testing (Not used).
The menu item 'Time' displays the internal processor time and date, the
time and date of the T4C network and the elapsed time, in seconds,
starting from the year 2000 (see page 8-6).
The menu item 'RealTimeInfo' displays the tag ID from the identified
cow, the content of the feed bin, the cows credit and the quantity of
food the cow has already eaten.
The menu item 'Tag id' displays the tag ID when a cow is present in the
COSMIX S and the value 1 if the cow is detected by the (optional)
photocell (see page 8-6).
The menu 'Valves/Blocker' is used to test the correct operation of the
valves (see page 8-7).
•
'Valve 1', to supply one portion of feed type 1
•
'Valve 2', to supply one portion of feed type 2 (if present)
•
'Valve 3', to supply one portion of feed type 3 (if present)
•
'Valve 4', to supply one portion of feed type 4 (if present)
•
'Valve 5' is not applicable
•
'Blocker' is not applicable.
The menu-item 'IDC Power level' is used to set the threshold value for
detection of the antenna signal (only Qwes Leg/Ear reader). If the
distance between the tag and the reader is too large and therefore the
signal is too low for correct identification, the signal is suppressed; 2 is
most sensitive, 0 less sensitive.
The default value is 1 (approx. 30 cm or 11.8 in).
4.4.2.5
Setup
Menu 'Setup' has the following submenus:
•
Calibrate weigh unit
•
Clear All Tables
•
Calibrate Valves
•
Empty Feedbin Value.
The menu 'Calibrate weigh unit' is not applicable.
The menu 'Clear All Tables' is used to clear the memory on the ADS 3830
pcb. Information about visiting cows and their indications is primarily
stored on the ADS 3830 pcb (see page 4-7). The data is also synchronized
DESCRIPTION AND OPERATION
with the data in T4C (see page 4-13). If you install the COSMIX S or a new
ADS 3830 pcb, the data on that board should be replaced by the data in
T4C.
The menu 'Calibrate Valves' is used to adjust the supplied feed doses to
the indicated amount (see page 8-4).
4.4.3
Cosmix Service Interface
4.4.3.1
Cosmix Service Interface
The COSMIX S service interface is the web interface of the ADS 3830 pcb.
The interface is accessible with an internet browser.
The service interface enables changes to be made to all the device
settings except the IP-address.
The COSMIX S service interface has the following worksheets:
•
Version
•
Settings
•
Table data
•
Raw data
•
Help
•
Test.
The worksheets 'Table data', 'Raw data', 'Help' and 'Test' are only used by
service engineers.
4.5
Operation
4.5.1
Identification
A cow enters the COSMIX S.
Qwes ACT tags
When the cow moves her head to the feed bin, the antenna in the ID
reader reads the tag. The ID reader sends the data of the tag to the ADS
3830 pcb.
Qwes H/HR tags
The photoelectric sensor on the control unit detects the presence of a
cow and activates the ID reader. The Xenos flash light in the ID reader
starts to flash. The infrared reader reads the data from the cow's tag and
sends the data to the ADS 3830 pcb. Then the flash light and the reader is
switched OFF.
Qwes leg tags
The floor antenna from the ID reader reads the tag of the cow. The ID
reader sends the data of the tag to the ADS 3830 pcb.
The cow ID is verified by the database present on the ADS 3830 pcb.
DESCRIPTION AND OPERATION
4-21
4.5.2
Feeding
The control system identifies the cow and synchronizes its information
with the T4C computer. Based on the information for the specific cow,
the feed credit is calculated. If the cow has feed credit the control system
opens the lock from the dosing unit(s) to provide the specific mix of
concentrates for the cow.
Before the COSMIX S starts feeding, two conditions must be met:
•
The cow has feed credit for the connected feed types
•
The cow is allowed to eat concentrates in the COSMIX S (No block
time).
Feed credit
The amount to be fed must be higher than 0 kg (0 lb) for at least one of
the connected feed types. Also, the amount must be higher than the
minimum portion size set in T4C.
Allowance to eat
Cows are allowed to eat if:
•
The visit is not in one of the blocking periods set in T4C
•
Robot feeding is switched on
•
The cow is not due to be milked, which means that it is not necessary
to attract the cow to go to the milking robot (and to eat her portion
of concentrates in the robot).
End of visit
At the end of the visit, the amount eaten is stored in the local database
and sent to T4C.
4.5.3
Interaction between the COSMIX S Components
The COSMIX S is connected to the T4C network. After installation, the
COSMIX S is given a device ID and an IP address. These settings are used
in the T4C software.
The T4C software
In the T4C software the feeding criteria are set. The T4C software supplies
the ADS 3830 pcb database with the necessary data. When a cow enters
the COSMIX S for the first time, the ADS 3830 pcb requests the cow data
from the T4C software. The first time the cow data request takes longer.
Once the cow is in the database on the ADS 3830 pcb, T4C automatically
synchronizes the cow data after each change of data.
The E-Link Manual Controller
The E-Link Manual Controller is used by the service technician to set the
initial settings (after installation) and to test and monitor the COSMIX S.
The COSMIX S Service Interface
The COSMIX S Service Interface is used by the service technician to set the
initial settings (after installation) and to test and monitor the COSMIX S.
The installation process of the COSMIX S has the following phases:
•
Prepare the installation
•
Install the COSMIX S
•
Connect the COSMIX S
•
Setup the software.
The network and power supply cables must not be installed next to
each other to prevent electromagnetic interference (EMI).
5.2
Preparation
5.2.1
List of Supplied Parts
The COSMIX S package must contain the parts listed below. Make sure all
these items are present before you start the installation. If items are
missing, contact your local Lely service provider.
The COSMIX S is supplied with either one, two, three or four feed
hoppers.
•
1× Feed unit with one feed hopper
•
1× Control unit
•
1× Cardboard box with small parts
•
2× Pipe with open T-clamps
•
2× Side fence
•
1× Front portal
•
1× Rear portal
•
1× Restraining bracket
•
1 - 3× Additional feed hopper(s) with parts for installation (optional)
•
2× Pipe (for transport only)
•
1× EWA transformer (Qwes leg models only)
•
1× Floor antenna mat (Qwes leg models only).
5.2.2
Preparation by the Owner
Before the installation can be done, some tasks must be done by the
owner of the COSMIX S with support from the Lely service provider.
These tasks are construction tasks for the farm and the purchase of
equipment necessary to use the COSMIX S.
Example tasks are:
•
Install a PC with T4C software in demo mode (if not already done)
•
Make sure that USB data storage space for making backups is
available
•
Make sure all cows have a collar with a tag and a number on both
sides
•
Make sure all cows are entered in T4C
•
Make sure all responder numbers are entered in T4C
•
Make sure a feed quantity for each cow is entered in T4C
•
Have the electrical supply installed and have it approved by the
energy company
•
Have the air compressor installed
•
Install the earth wire and get it approved by the energy company
•
Install an external feed delivery system
•
Consult the local Lely service provider for the correct position of the
COSMIX S in the barn.
•
Read and understand the COSMIX S Installation and Operator Manual.
5.2.2.1
Recommendations for Installation of an External Feed
Delivery System
Please consult your Lely service provider for advice about the
installation of the tube feeder(s).
•
If possible install the tube feeder(s) with an angle above the COSMIX
S. This prevents contamination of the COSMIX S with dust.
•
If you do:
•
Install a screen between the tube feeders and the COSMIX S
•
Make sure the distance between the floor and the bottom of the feed
system is at least 215 cm (85.7 in).
•
Make holes in the cover of the feed funnel to attach the drop pipes
from the tube feeders. The holes in the cover of the feed funnel must
be the correct size for the drop pipes so that dust does not
contaminate the COSMIX S.
•
Lely recommends that you install level switches in the feed funnels to
control the tube feeder system to ensure that the feed funnels stay
full.
•
Make sure the tube feeder(s) do not apply any additional weight to
the dosing units.
If the feed bin is empty the feed intake will decrease, which can
decrease milk production of the cows.
5.2.2.2
Install the Air Compressor
This section only applies when an air compressor is not installed.
1.
Refer to the manual of the air compressor and install the
compressor in the compressor room.
2.
Connect the pneumatic hose to the compressor.
5.2.3
Preparation by Lely
Make sure the owner is familiar with the T4C software.
5.2.4
Position of the Cosmix
5.2.4.1
General Rules and Recommendations
The correct position of the COSMIX S will depend on the operational
management of the farm. Analyze the operational requirements of the
farm before you install the COSMIX S. This will make sure the COSMIX S is
installed in the correct position.
Please contact your Lely service provider for help with your specific
requirements.
•
The COSMIX S must be installed on a solid, and correctly constructed
foundation
•
The cows should have easy access to the COSMIX S
•
The cows must not be able to lay down in the exit route from the
COSMIX S.
Figure 16. Example: installation in the barn
KEY:
1. Spare room - 2. Cosmix concentrate feeder - 3. Walk alley - 4. Barn
5.3
Install the COSMIX S
Wear safety shoes.
5.3.1
Preparation
This procedure requires a minimum of two persons.
Hold the side fences while unpacking the parts.
1.
Unpack all parts.
2.
Remove the two pipes with the text "For transport only" and the
four T-clamps from the portals.
Install the Side Fences on the Portals
Parts
•
2× Side fence
•
1× Front portal
•
1× Rear portal
•
4× Bracket set (1.5 in×1.5 in)
•
16× Bolt, washer, nut
•
4× T-clamps.
Installation
This procedure requires a minimum of two persons.
1.
Put the front portal (1) (see figure 17 on page 5-6) on the floor,
hold it.
The front portal has a small mounting strip on top of it.
2.
Loosely install both side fences (6) with the four bracket sets (5) on
the front portal with the bolts, washers and nuts.
3.
Loosely install the four T-clamps (4) on the side fences with a 8 mm
Allen key (2).
4.
Remove the four bolts (3)(see figure 18 on page 5-7) from the T-
clamps.
5.
Lift both side fences and put screwdrivers or pins (5) in the holes in
the front portals to secure the position of the side fences.
6.
Put the rear portal (1) on the floor, hold it.
Do not fully tighten the T-clamps
Loosely install the side fences with the T-clamps on the rear portal
with the four bolts (2).
Figure 17. Install the portals and fences
KEY:
1. Front portal - 2. Allen bolt - 3. Bolt - 4. T-clamps - 5. Brackets - 6. Side fences
Figure 18. Lift the fences and install the rear portal
KEY:
1. Rear portal - 2. Bolt - 3. Allen bolt - 4. Allen bolt - 5. Screw driver
5.3.3
Level, square and tighten the Fences
Special tools
•
Level
Installation
1.
Make sure the distance between the front and rear portal is 101.5
cm (40.0 in), move the front portal (1) if necessary.
2.
Make sure the side fences are level (2), move the T-clamps (3) up or
down if necessary.
Make sure the distances between the front sides of both side
fences and the opposite brackets (1) (see figure 20 on page 5-9) are
equal (A = B).
4.
Tighten the bolts and nuts on the four brackets (1) on the front
portal.
5.
Tighten the bolts on the four T-clamps (4) (see figure 19 on page 5-
8) with a 8 mm Allen key.
6.
Remove the screwdrivers or pins from the front portal that keep
the fences in place.
Figure 19. Level the side fences
KEY:
1. Front portal - 2. Level - 3. T-clamp - 4. Allen bolt
Figure 20. Square the angles
KEY:
1. Front portal
A: Distance between front side of side fence and opposite bracket
B: Distance between front side of side fence and opposite bracket
5.3.4
Install the Portals on the Floor
Parts
•
8× Expander bolt M12×120×80
Installation
Use the supplied expander bolts on concrete floors, otherwise use
suitable M12 installation hardware.
1.
Install the front and rear portal on the floor, at least 3 cm (1.2 in)
from the wall (wall to outside pipe).
Install the Control Unit
5.3.5.1
Install the Control Unit - General
For installation of a COSMIX S with Qwes H/HR-LD identification refer to
Install the Control Unit - Qwes H/HR-LD Identification (see page 5-20)
Parts
•
1× Control unit
•
4× Carriage bolt M8×16, washer and cap nut
Installation
1.
Put the control unit (2) (see figure 21 on page 5-11) on the brackets
between the front portal and the rear portal, with the CE-plate (1)
on the rear and the cable throughput on the front.
2.
Open the cover of the control unit.
3.
Loosen the bolts that tighten the two strips on the cable
throughput.
4.
Feed the earthing cable, from the control box, through the cable
throughput.
5.
Install a carriage bolt (3) (see figure 21 on page 5-11) through the
hole in the bottom of the control box and the strip on the front
portal.
6.
Install the cable shoe (4) from the earthing cable with a washer (5)
and a cap nut (6) on the carriage bolt.
7.
Install the control unit on the bracket on the portals with four
carriage bolts, washers and cap nuts.
8.
Close the cover of the control unit.
Figure 21. Install the control unit
KEY:
1. CE-plate - 2. Control unit - 3. Carriage bolt - 4. Cable shoe - 5. Washer - 6. Cap nut
5.3.5.2
Install the Control Unit - Qwes H/HR-LD Identification
Parts
•
1× Control unit
•
4× Carriage bolt M8×16, washer and cap nut
•
1x Reader-bracket assembly
Installation
1.
Put the control unit (6)(see figure 22 on page 5-12) on the brackets
(3 and 7) between the front portal and the rear portal, with the CE-
plate (5) on the rear and the cable throughput on the front.
2.
Open the cover of the control unit (6).
3.
Loosen the bolts that tighten the two strips on the cable
throughput (11)(see figure 35 on page 5-26).
4.
Feed the earthing cable (12), from the control box, through the
cable throughput.
5.
Install a carriage bolt (3)(see figure 21 on page 5-11) through the
hole in the bottom of the control box and the strip on the front
portal.
Install the cable shoe (4) from the earthing cable on the carriage
bolt.
7.
Install the reader-bracket assembly (8)(see figure 22 on page 5-12)
and the control unit (6) on the brackets (3 and 7) on the portals
with four carriage bolts (4), washers (2) and cap nuts (1).
8.
Close the cover of the control unit (6).
Figure 22. Install the Control unit — Qwes H/HR-LD
KEY:
1. Cap nut - 2. Washer - 3. Support bracket - 4. Carriage bolt - 5. CE plate - 6. Control unit - 7. Support bracket - 8. Reader
bracket assembly
5.3.6
Install the Front Plate
Parts
•
1× Front plate
•
4× Bolt M12×80 and washer
•
8× Nut M12
2× Mounting pipe
•
4× T-clamp
This procedure requires a minimum of two persons.
Installation
1.
Loosely install the four T-Clamps (8)(see figure 24 on page 5-14) on
the two mounting pipes (1) with an 8 mm Allen key.
2.
Install the four bolts (9) and eight nuts (7) on the mounting pipes.
The mounting pipes can be installed on three different heights
on the back plate (3) and (4)
3.
Install the two mounting pipes on the rear plate with the four nuts
(5) and washers (6).
4.
Remove the four bolts (3)(see figure 25 on page 5-15) from the four
T-clamps (1) with an 17 mm wrench.
Figure 23. Do not fully tighten the T-clamps
5.
Install the front plate on the side fences with the four bolts (3)(see
figure 25 on page 5-15).
6.
Fully tighten the bolts in the T-clamp (2)(see figure 25 on page 5-
15) with an 8 mm Allen key.
Figure 24. Install the pipes on the front plate
KEY:
1. Mounting pipe - 2. Front plate - 3. Lower mounting pipe installation holes - 4. Upper mounting pipe installation holes - 5.
Nut - 6. Washer - 7. Nuts - 8. T-clamp - 9. Bolt
Figure 25. Install the front plate on the fences
KEY:
1. T-clamp - 2. Allen bolt - 3. Bolt
5.3.7
Install the Feed Bin and the Feed Hopper on the Front Plate
Parts
•
Dosing units (1-4)
•
Feed bin
•
Feed funnel cover
•
Feed hopper cover
Installation
1.
Install the feed bin (4)(see figure 26 on page 5-16) on the front
plate with the four bolts, nuts and washers (3), (1) and (2).
2.
Install the dosing unit(s) (1)(see figure 27 on page 5-17) on the
front plate.
3.
Install the feed funnel cover (2) on the front plate and the feed bin.
Install the feed hopper cover (3) on the front plate with the
clamping spring (4).
Figure 26. Install the feed bin
KEY:
1. Bolt - 2. Washer - 3. Nut - 4. Feed bin
Figure 27. Install the dosing unit, feed hopper and feed funnel
KEY:
1. Dosing unit - 2. Feed funnel cover - 3. Feed hopper cover - 4. Clamping spring
5.3.8
Install the Rear Fences
Parts
•
2× Rear fence
•
4× Bolt M10×70, washer and cap nut
•
4 x Clamp M8, nuts and cap nuts
Preparation
1.
Determine the installation position of the rear fences: longest (1)
(see figure 28 on page 5-18), middle (2) or shortest (3).
Installation
1.
Loosely install the upper side of one of the rear fences on a side
fence with a 70 mm bolt (3)(see figure 29 on page 5-19), a washer
(2) and a cap nut (1).
2.
Loosely install the U-bolt (4) with the clamp (5), the nuts (6) and the
cap nuts (7) to the upper side of the fence.
Support the rear fence and loosely install the lower side of the rear
fence on the side fence with a 70 mm bolt (3) a washer (2) and a
cap nut (1).
4.
Loosely install the U-bolt (4) with the clamp (5), the nuts (6) and the
cap nuts (7) to the lower side of the fence.
5.
Support the rear fence and tighten all nuts
6.
Repeat steps 1 to 5 for the other rear fence.
Figure 28. Rear fence position
KEY:
1. Longest position - 2. Middle position - 3. Shortest position
Figure 29. Install the rear fences
KEY:
1. Cap nut - 2. Washer - 3. Bolt (70 mm) - 4. U-bolt - 5. Clamp - 6. Nut - 7. Cap nut
5.3.9
Install the Restraining Bracket
Parts
•
1× Restraining bracket
•
2× Bolt M10×60 and nut
Installation
1.
Loosely install the restraining bracket (3)(see figure 30 on page 5-
20) on top of the rear fences, with the bolts (2) and nuts (1).
Figure 30. Install the restraining bracket
KEY:
1. Cap nut - 2. Bolt - 3. Restraining bracket
5.3.10
Install a Qwes leg ID Reader and a Floor Antenna
This section only applies when you have a COSMIX S with Qwes leg
identification.
Parts
•
1× Floor antenna mat
•
1× EWA transformer box with pcb
•
1× EWA transformer housing
•
2× Bolt M8×20, washer, nut
•
3 m (9.8 ft) coax cable.
Installation
1.
Install the floor antenna mat (1)(see figure 31 on page 5-22) on the
floor, between the two piles of the front portal.
Feed the coax cable through the hole in the upper side of the
frame (3) to the hole in the front frame (2).
Connect the EWA transformer
1.
Remove the cover (2) (see figure 32 on page 5-23)from the EWA
transformer box.
2.
Loosen four bolts that attach the pcb on the EWA transformer box.
3.
Route the coax cable through the gland nut (1) into the EWA
transformer box.
4.
Use a wire stripper to remove approximately 5 cm (2 in) from the
insulation.
5.
Unbundle the woven shielding.
6.
Use a wire stripper to remove approximately 1 cm (0.4 in) from the
inner insulation.
7.
Insulate the shielding.
8.
Connect the shielding to the connector (6) (see figure 33 on page 5-
24) on the EW transformer pcb.
9.
Connect the inner wire to the connector (7) on the EWA
transformer pcb.
10.
Make sure the antenna connectors (3) and (4) are connected to the
connectors on the EWA transformer box.
11.
Make sure the two jumper wires are connected to the connectors
(1) and (2).
12.
Install the EWA transformer pcb in the EWA transformer box with
the four bolts.
13.
Tighten the gland nut on the EWA transformer box.
14.
Install the cover on the EWA transformer box.
15.
Feed the two antenna wires through the two holes in the EWA
transformer housing (3)(see figure 34 on page 5-25).
16.
Connect the cable shoes from the antenna cables to the connectors
on the EWA box with two washers, toothed washers and nuts (see
figure 34 on page 5-25).
Do not install the EWA transformer housing on the front portal,
before you adjust the floor antenna signal (see page 8-8).
Figure 31. Install the antenna mat
KEY:
1. Floor antenna mat - 2. Hole (front frame) - 3. Hole (upper side frame)
Figure 32. Connect the Qwes leg-ID reader cable to the EWA transformer
KEY:
1. Coax cable through gland nut - 2. Cover - 3. Potentiometer - 4. Wire - 5. Terminal strip
Figure 33. Connect a Qwes leg ID reader
KEY:
1. Jumper wire connector - 2. Jumper wire connector - 3. Antenna wire connector - 4. Antenna wire connector - 5. Trimmer
coil - 6. Shielding connector - 7. Inner wire connector
Figure 34. Install the EWA transformer
KEY:
1. EWA transformer box - 2. Upper cover EWA transformer housing - 3. Lower cover EWA transformer housing - 4. Nut - 5.
Washer - 6. Cable shoe - 7. Washer
5.4
Connect the COSMIX S
Use a cable channel to protect the cables and tubes against external
mechanical effects. Use a separate cable channel for the network
cable to protect it from electromagnetic interference (EMI).
5.4.1
Connect the Air Tubes
1.
Find the air tubes that are connected to the dosing unit.
Each feed dosing unit has a black and a blue air tube.
2.
Feed the air tubes into the control unit.
3.
Connect the black air tube to the tube connector (9)(see figure 35
on page 5-26) on the valve unit.
Connect the blue air tube to the tube connectors (10) on the valve
unit.
5.
Feed the compressed air supply tube into the control unit.
6.
Connect the air supply tube to the air coupling of the pressure
reducer (1)(see figure 9 on page 4-9).
Figure 35. Connect the control unit
KEY:
1. Air coupling - 2. FSK pcb - 3. Network connector - 4. Earth connector - 5. Antenna connector Velos box - 6. Not used - 7.
24V power supply - 8. Earthing clamp - 9. Tube connector - 10. Tube connector - 11. Cable feed - 12. Earth cable
5.4.2
Connect the ID-Reader Cable
1.
Find the cable to the ID reader.
2.
Route the ID reader cable into the control unit.
3.
Remove approximately 7 cm (2.8 in) from the outer insulation with
a wire stripper.
4.
Remove approximately 6 cm (2.4 in) from the shielding.
5.
Turn the shielding back.
6.
Remove approximately 1 cm (0.4 in) from the inner insulation with
a wire stripper.
Qwes ACT ID reader
1.
Remove the bolts and the clamp from the FSK pcb (2)(see figure 35
on page 5-26).
Install the cable connector on the pcb with the bolt.
3.
Install the cable with the clamp and the two bolts on the pcb.
4.
Make sure the clamp and the shielding are connected.
Qwes leg ID reader
1.
Insulate the wire shielding with a piece of heat shrink.
2.
Connect the wire shielding to the - antenna connector (5) on the
Velos box (bottom-right).
3.
Connect the inner wire to the + antenna connector (5) on the Velos
box.
5.4.3
Install the Earthing
1.
Find the external earthing wire.
2.
Feed the cable into the control unit.
3.
Connect the earthing wire to the earth connector (4)(see figure 35
on page 5-26).
5.4.4
Prepare the Network Cable
Use a Network Switch if the length of the network cable is more than
100 m (109 yd).
5.4.4.1
Introduction
A type 1 or a type 2 network connector can be installed to a network
cable.
Figure 36. Network Connector Types
KEY:
1. a) Type 1 network connector (T-568A) - 1. b) Type 1 network connector (T-568B) - 2. Type 2 network connector (T-568A)
5.4.5
Install a Type 1 Network Connector
Special tools
•
Ethernet crimping tool
Preparation
1.
Make sure the network cable is of type S-FTP 200MHz CAT5e.
2.
Cut a piece of network cable to the correct length.
3.
Feed the network cable into the control unit.
Installation
1.
Install the connector cover and the cap on the network cable (1)
(see figure 37 on page 5-30).
2.
Remove approximately 5 cm (1.96 in) of the insulation (2) of one
side of the cable.
3.
Slide the screen backward (3).
4.
Fold the wire backward (4).
5.
Peel the metal shield from the cable (4).
The inside of the metal shield is covered with an insulating film
(often blue colored). If the metal shield is turned backward, the
cable cannot make a ground connection with the connector.
6.
Remove the plastic shield from the cable (5).
Splice the wires (6) and (7).
8.
Sort the wires by color according to one of the tables.
A Type 1 Network Connector can be configured accordingly a
Type A or Type B wiring scheme. Use the same scheme (A or B)
on both cable ends.
T-568A
T-568B
1
Green/White
1
1
Orange/White
1
2
Green
2
2
Orange
2
3
Orange/White
3
3
Green/White
3
4
Blue
4
4
Blue
4
5
Blue/White
5
5
Blue/White
5
6
Orange
6
6
Green
6
7
Brown/White
7
7
Brown/White
7
8
Brown
8
8
Brown
8
9.
Cut the wires to a length of 1.3 cm (0.51 in) (9).
10.
Put the wires and the cable fully in the RJ-45 plug (10).
11.
Make sure the wire is on the left or right side of the plug (11).
12.
Put the plug in the crimp tool until it clicks (12).
13.
Squeeze the crimp tool until it clicks (13).
14.
Push the plug tab and remove the plug from the crimp tool (14).
15.
Remove the shielding and the wire (15).
16.
Repeat the installation procedure for the other side of the network
cable.
Figure 37. Install a type 1 network connector
5.4.6
Install a Type 2 Network Connector
Special tools
Ethernet crimping tool
Preparation
1.
Make sure the network cable is of type S-FTP 200MHz CAT5e.
2.
Cut a piece of network cable to the correct length.
3.
Feed the network cable into the control unit.
Installation
1.
Install the connector cover and the cap on the network cable (1)
(see figure 38 on page 5-33).
2.
Remove approximately 5 cm (2 in) of the insulation (2).
3.
Slide the screen backwards (2).
4.
Install the metal shielding tape on the screen (2).
5.
Cut the remaining screen (2).
6.
Remove the plastic shield from the cable.
7.
Splice the wires. The blue and red wires on one side, the yellow and
green wires on the other side (3).
A Type 2 Network Connector can only be configured accordingly
a Type A wiring scheme. Use scheme (A) on both cable ends.
Type A
1
Green/white
1
2
green
2
3
Orange/white
3
4
Blue
4
5
Blue/white
5
6
Orange
6
7
Brown/white
7
8
Brown
8
8.
Install the connector on the cable with the metal contact on the
metal shielding tape (4).
Make sure the wire order in the network connector is the same
as the network connector on the other side of the network
cable.
9.
Put the wires in the correct position (3) and (4)
10.
Cut the wire to length (5).
11.
Install a plate on both sides of the connector (6).
Push both plates until you hear a click (7).
13.
Push the connector cover on the connector until you hear a click
(8).
14.
Install the cap on the cover (8).
Install the Network Cable on an Earthing Clamp
Installation
1.
Remove one of the earthing clamps (8)(see figure 35 on page 5-26).
2.
Connect the network connector to the ADS 3830 pcb (3).
3.
Mark the position of the earthing clamp on the network cable.
4.
Remove the network connector from the ADS 3830 pcb.
5.
Strip approximately 1.5 cm (0.4 in) of the marked insulation of the
(1) and (2)(see figure 39 on page 5-34).
6.
Attach the network cable to the earthing connector with the (8)
(see figure 35 on page 5-26).
7.
Make sure the shielding and the earth connector make good
contact.
Do not tighten the clamp too firmly (less than finger tight
about 30 nm), to prevent damage to the cable (wires and the
metal shield).
8.
Tighten the clamp with a screw driver.
Figure 39. Install a network cable to a ground rail
Remove or install the Covers from the Feed Unit
Removal
1.
Pull the springs on both sides of the feed hopper cover (1)(see
figure 40 on page 5-35), remove the feed hopper cover (2).
2.
Lift the feed funnel cover (3) and remove it.
Installation
1.
Install the feed funnel cover (3) on the feed unit.
2.
Install the feed hopper cover (2) on the feed unit.
Figure 40. Remove or install the covers
KEY:
1. Clamping spring - 2. Feed hopper cover - 3. Feed funnel cover
5.5
Setup the COSMIX S
1.
Make sure the E-Link is connected and the main switch is switched
On.
2.
Set the IP-address.
The IP-address for the first COSMIX S is 10:4:1:11 for the second
10:4:1:12 and so on.
Set the device address of the COSMIX S Set the Device Address of
the Cosmix (see page 8-2).
The device address for the first COSMIX S is 11, for the second 12
and so on.
4.
Set the device address T4C (see page 8-2).
The device address for the T4C server is 1.
5.
Make sure the feed blocker is set to 'open'.
6.
Make sure the weight unit is set to 'off'.
7.
Add the COSMIX S device to the T4C software .
8.
Add the feed types to each feed hopper (see page 8-13).
9.
Calibrate the valves (see page 8-4).
10.
Set the portion size (see page 8-5).
11.
Set the feed speed (see page 8-14).
12.
Clear all tables (see page 8-5).
13.
Test the correct operation of the COSMIX S (see page 8-6).
14.
Disconnect the E-Link Manual Controller.
List Details about the Rest Feed
Make sure the connection with T4C is still working properly if:
•
Two or more Cosmix machines are installed and
•
The amount of rest feed in T4C raises quickly.
The T4C report ''Feeding - Rest Feed' displays only information about
cows that have rest feed.
1.
Go to the page Analysis/Reports > Reports
2.
Select the report 'Feeding - Rest Feed'.
Make sure feed types in the COSMIX S have a unique name. This
makes it possible to report feeding details from the COSMIX S
apart from the milking robot.
3.
Select the feed types to be added to the report.
4.
Select button [Open].
6.2
List a Feed Overview
The report ''Feed Overview' displays information about all cows.
1.
Go to the page Analysis/Reports > Reports
2.
Select the report 'Feed Overview'.
Make sure feed types in the COSMIX S have a unique name. This
makes it possible to report feeding details from the COSMIX S
apart from the milking robot.
3.
Select the feed types to be added to the report.
4.
Select button [Open].
List a Device Intake Overview
The report ''Feeding - Device Intake Overview' displays the total feed
intake per device (milking robot and COSMIX S) and per feed type in a
given period.
1.
Go to the page Analysis/Reports > Reports
2.
Select the report 'Feeding - Device Intake Overview'.
3.
Enter the reporting period:
•
Enter the number of days (start and end), or
•
Select a specific start and end date.
4.
Select button [Open].
TEST AND ADJUSTMENT
8-1
8
TEST AND ADJUSTMENT
8.1
Introduction
This chapter contains the following test and adjustment procedures for
the COSMIX S Concentrate Feeder:
•
Set the network settings (see page 8-1)
•
Make basic software settings (see page 8-3)
•
Test the operation of the COSMIX S (see page 8-6)
•
Adjustments in the T4C software (see page 8-13)
•
Adjustments with the service interface (see page 8-14).
8.2
Connect or Remove the E-Link Manual Controller
Block the cow traffic to the COSMIX S before you do this
procedure.
Connect
1.
Loosen the cap until you can remove it from the connector on the
control unit (7)(see figure 9 on page 4-9).
2.
Connect the connector of the E-Link Manual Controller to the
connector on the control unit.
3.
Fully turn the ring on the connector.
Removal
1.
Loosen the ring until you can remove the connector of the E-Link
Manual Controller.
2.
Install the cap on the connector on the control unit.
8.3
Set the Network Settings
8.3.1
Set Defaults
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
In the main menu, select 'Network settings' and push button [
].
2.
Select 'Set defaults' and push button [
].
3.
Push soft button [OK] to confirm.
TEST AND ADJUSTMENT
After a few seconds you return to the main menu.
8.3.2
Set the Device Address of the Cosmix
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
In the main menu, select 'Network settings' and push button [
].
2.
Select 'Dev addr Cosmix' and push button [
].
3.
Use soft buttons [<] or [>] to select the position you want to
change.
4.
Use buttons [
] or [
] to change the value.
5.
Push soft button [OK] to confirm.
After a few seconds you return to the main menu.
8.3.3
Set the T4C Device Address
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
In the main menu, select 'Network settings' and push button [
].
2.
Select 'Dev addr T4C' and push button [
].
3.
Use soft buttons [<] or [>] to select the position you want to
change.
4.
Use buttons [
] or [
] to change the value.
5.
Push soft button [OK] to confirm.
After a few seconds you return to the main menu.
8.3.4
Set the IP-address
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
In the main menu, select 'Network settings' and push button [
].
2.
Select 'IP Address' and push button [
].
TEST AND ADJUSTMENT
8-3
3.
Use soft buttons [<] or [>] to select the position you want to
change.
4.
Use buttons [
] or [
] to change the value.
5.
Push soft button [OK] to confirm.
After a few seconds you return to the main menu.
8.4
Make Basic Software Settings
8.4.1
Display the Software Version
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
In the main menu, select 'Version info' and push button [
].
2.
Push button [
].
After a few seconds you return to the main menu.
8.4.2
Reset to the Default Settings
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
In the main menu of the (UI name), select Settings and push [
].
2.
Select 'Set defaults' and push button [
].
3.
Push soft button [OK] to confirm.
After a few seconds you return to the main menu.
8.4.3
Set the Time
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
In the main menu of the (UI name), select Settings and push [
].
2.
Select 'Time' and push button [
].
3.
Use soft buttons [<] or [>] to select the position you want to
change.
TEST AND ADJUSTMENT
4.
Use buttons [
] or [
] to change the value.
5.
Push soft button [OK] to confirm.
After a few seconds you return to the menu 'Settings'.
8.4.4
Make the Photocell Active
Block the cow traffic to the COSMIX S before you do this
procedure.
Only applicable for Qwes - H/HR readers.
Use the E-Link manual controller for this procedure.
1.
In the main menu, select ‘Settings’ and push button [
].
2.
Select 'Photocell active' and push [
].
3.
Use the buttons [
] or [
] to change the value.
4.
Push button [OK] to confirm.
After a few seconds you return to the menu 'Settings'.
8.4.5
Calibrate the Valves
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
In the main menu, select 'Setup' and push button [
].
2.
Select 'Calibrate Valves' and push button [
].
3.
Select 'Valve' and push button [
].
4.
Push the buttons [
] or [
] to select the number of the dosing
unit (see page 4-6) and push [
].
5.
Select 'Portions' and push button [
].
6.
Push the buttons [
] or [
] to select 10 feed portions.
7.
Push button [
] to confirm.
8.
Push button [START]. The valve opens and closes to dose each of
the 10 feed portions. The software counts down the amount of
feed portions.
9.
Use a balance to weigh the feed.
10.
Calculate the portion size (total weight/10).
TEST AND ADJUSTMENT
8-5
11.
Set the correct portion size (see page 8-5).
8.4.6
Set the Portion Size
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
In the main menu, select ‘Settings’ and push [
].
2.
In the menu 'Settings' select 'Portion size1', 'Portion size2', 'Portion
size3' or 'Portion size4' and push button [
].
3.
Use soft buttons [<] or [>] to select the position you want to
change.
4.
Use buttons [
] or [
] to change the value.
5.
Push soft button [OK] to confirm.
After a few seconds you return to the menu 'Settings'.
8.4.7
Adjust the Portion Size
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
Make sure the feed bin is empty.
2.
Use the E-Link to drop five portions for feed type 1 (see page 8-7).
3.
Remove the food from the feed bin.
4.
Use a balance to weigh the food.
5.
Calculate the portion size by dividing the total weight by five.
6.
Set the portion size for feed type 1 (see page 8-5).
7.
Repeat the procedure for other feed types.
8.4.8
Clear all Tables
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
In the main menu of the (UI name), select ‘Setup’ and push [
].
2.
Select 'Clear All Tables' and push button [
].
TEST AND ADJUSTMENT
The E-Link displays the message "Remove Local Data!!!".
3.
Push soft button [OK] to confirm.
After a few seconds you return to the menu 'Setup'.
8.5
Test the Operation of the COSMIX S
8.5.1
Test the Time Setting
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
In the main menu, select 'Testing' and push button [
].
2.
Select 'Time' and push button [
].
3.
Make sure the values are correct.
1.
If the settings are correct, push button [
].
2.
Else, set the time (see page 8-3).
8.5.2
Display Real Time Information
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
In the main menu, select 'Testing' and push button [
].
2.
Select 'RealTimeInfo' and push button [
].
The display shows:
•
the tag ID of the identified cow
•
the content of the feed bin
•
the cows credit
•
the amount food the cow has already eaten
8.5.3
Test the Tag-ID
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
TEST AND ADJUSTMENT
8-7
1.
In the main menu, select 'Testing' and push button [
].
2.
Select 'Tag id' and push button [
]. The display shows:
•
the tag ID of the identified cow
•
a value 1 if the cow is detected by the (optional) photocell.
3.
Push button [
].
8.5.4
Test the Dosing Units
Block the cow traffic to the COSMIX S before you do this
procedure.
Use the E-Link manual controller for this procedure.
1.
Make sure the feed funnels are not empty.
2.
In the main menu, select 'Testing' and push button [
].
3.
Select 'Valves/Blocker' and push button [
].
4.
Select 'Valve 1' and push button [
].
5.
Make sure the dosing unit gives the correct food type.
6.
If the COSMIX S has two or more feed types:
1.
Select 'Valve 2' and push button [
].
2.
Make sure the dosing unit gives the correct food type.
7.
If the COSMIX S has three or more feed types:
1.
Select 'Valve 3' and push button [
].
2.
Make sure the dosing unit gives the correct food type.
8.
If the COSMIX S has four feed types:
1.
Select 'Valve 4' and push button [
].
2.
Make sure the dosing unit gives the correct food type.
9.
If one or more dosing units do not give the correct food type,
assign the correct feed type to the dosing unit (see page 8-13).
8.6
Adjust the Floor Antenna Signal (Qwes leg models only)
Special tools
•
Non-metal screwdriver (e.g. plastic)
Preparation
1.
Open the control unit.
2.
Find the indication LEDs (4)(see figure 41 on page 8-9) on the Velos
box (3).
TEST AND ADJUSTMENT
3.
Open the EWA transformer box (see page 5-23).
4.
Find the trimmer coil (2) on the EWA transformer pcb (1).
Adjust
1.
Turn the trimmer coil on the EWA transformer pcb clockwise until it
is completely in the coil housing with a non-metal screwdriver.
2.
Turn the trimmer anti-clockwise until the green LED (4) lights up.
3.
If the green LED does not light up:
1.
Remove the jumper on connector B1 on the EWA
transformer pcb (1)(see figure 33 on page 5-24).
2.
Connect the jumper to connector B2 on the EWA transformer
pcb.
3.
Repeat the adjustment procedure.
Attach the EWA transformer housing to the front portal
1.
Install the cover on the EWA transformer box.
2.
Install the EWA transformer box in the EWA transformer housing.
Make sure not to damage the cables.
3.
Connect the rear sides of the parts of the housing.
4.
Slide the assembly over the front portal.
5.
Attach the EWA transformer on the front portal with two M8 bolts,
washers and nuts (1)(see page 8-10).
TEST AND ADJUSTMENT
8-9
Figure 41. Adjust the EWA transformer
KEY:
1. EWA transformer pcb - 2. Trimmer coil - 3. Velos box - 4. Indication LEDs - 5. Terminal strip
TEST AND ADJUSTMENT
Figure 42. Remove/Install the Qwes leg ID reader
KEY:
1. Cap nut - 2. Washer - 3. Bolt
A: Open the EWA transformer housing
B: Close the EWA transformer housing
C: Attach the EWA transformer housing to the front portal
D: Install the EWA transformer housing with M8 bolts, washers and nuts.
8.7
Adjust the Photoelectric Sensor
Special tools
•
Screwdriver.
Preparation
1.
Open the control unit.
2.
Find the photoelectric sensor.
3.
Find the detection distance adjuster on the photoelectric sensor.
TEST AND ADJUSTMENT
8-11
Adjust
To set the cow detection area (see figure 43 on page 8-11):
1.
Turn the detection distance adjuster (4)(see figure 44 on page 8-12)
completely counterclockwise with the screwdriver to the minimum
detection distance (I)(see figure 45 on page 8-13).
2.
Put a matt black object at approximately 120 cm (47.2 in) above the
ground.
3.
Slowly turn the detection distance adjuster (4) clockwise with the
screwdriver until the detection LED (1) comes on and the stability
LED (3) goes out.
4.
Make a mark of the position (A)(see figure 45 on page 8-13) on the
adjuster indicator (II).
5.
Remove the object.
6.
Slowly turn the detection distance adjuster (4)(see figure 44 on
page 8-12) further clockwise with the screwdriver until the
detection LED (1) comes on again (either the floor is scanned or the
maximum detection distance is reached).
7.
Make a mark on the position (B)(see figure 45 on page 8-13) on the
adjuster indicator (III).
8.
Turn the detection distance adjuster (4)(see figure 44 on page 8-12)
counter clockwise with the screwdriver until the adjuster indicator
is exactly in the middle of the positions A and B (IV).
Figure 43. Cow detection area
TEST AND ADJUSTMENT
Figure 44. Photocell LEDs and detection distance adjuster
KEY:
1. Detection LED (red) - 2. Adjuster indicator - 3. Stability LED (green) - 4. Detection distance adjuster