Control panel installation manual

This manual is valid for control panel JA-80K version KE60108 (printed on internal circuit board). The control panel can be configured by a PC running ComLink software - version 80 or higher. ...

Installation manual: Oasis security system JA-80K

- 2 - MKE55800 Contents: 1. CONTROL PANEL ARCHITECTURE................................................... 3 1.1. OPTIONAL SYSTEM CONFIGURATIONS ................................................ 4 2. INSTALLATION ..................................................................................... 4 2.1. POWER ...

Installation manual: Oasis security system JA-80K

- 3 - MKE55800 System installation shall only be undertaken by qualified technicians holding a training certificate issued by an authorized distributor. The manufacturer cannot be held responsible for any damage or consequences related to the improper or incorrect use of this product. 1. Control panel archite ...

Installation manual: Oasis security system JA-80K

- 4 - MKE55800 sent to alarm receiving centres (central monitoring stations). They can notify the user using SMS reports and allow remote control and programming of the system by mobile phone and the Internet. Another option is the JA-80X communicator which reports alarms via a traditional phone line using vo ...

Installation manual: Oasis security system JA-80K

- 5 - MKE55800 Communicator connector – allows the connection of an optional communicator to the main board. Internal wiring connector – connects the internal wiring in the control panel housing. Terminals: AC 20V the transformer output is connected here. 01, GND, 02 are hard-wired inputs for the control ...

Installation manual: Oasis security system JA-80K

- 6 - MKE55800 disconnected. After the mains supply has been restored battery charging starts again and the system will begin to function again. Ensure that the battery is correctly connected (Polarity: RED = positive +, BLACK = negative -). WARNING – the battery is sold charged – to maintain safety, avoi ...

Installation manual: Oasis security system JA-80K

- 7 - MKE55800 control panel twice but to two different addresses with different features –see 12.40. • Only a single device can be enrolled to each address. • When indicator A lights, it means the displayed address is occupied and therefore no more devices can be enrolled to this address. • If a devi ...

Installation manual: Oasis security system JA-80K

- 8 - MKE55800 minutes so it is impossible to combine multiple control panels in one UC or AC receiver. 12. Control panel programming The most convenient way to program the system is to use a PC running Comlink software. The system can however also be programmed by keying in the sequences in section 12.1. • ...

Installation manual: Oasis security system JA-80K

- 9 - MKE55800 other intruder detector within 40 minutes, an alarm will be triggered. If the first triggered detector has a DEL reaction and it is not confirmed by any other detector, it will not trigger an alarm after the entrance delay has expired. is set (armed). Exit delay beeps 33x 331 = YES 330 = N ...

Installation manual: Oasis security system JA-80K

- 10 - MKE55800 Device reactions and section assignment (detectors, key fobs, control panel and keypad inputs) • A detector’s natural reaction can be INS, DEL or Fire (selectable in the detector) • The natural reaction of Control panel & Keypad wired inputs is DEL Keyfob natural reactions: (or )= SET ...