Fluke 9116A Operation & User’s Manual

File Specifications

Brand: Fluke
Category: Furnace
Model: 9116A (Operation & User’s Manual), prMnvzCMvZv/Q
File Type: PDF
File Size: —
Pages: 80 pages

Download PDF

Download Fluke 9116A Manual (80 pages)

Read Online:

Read the Fluke 9116A Operation & User’s Manual online using the built-in PDF viewer.

Key Pages of Document

Limited Warranty & Limitation of Liability

Each product from Fluke Corporation, Hart Scientific Division ("Hart") is warranted to be free from de- fects in material and workmanship under normal use and service. The warranty period is 1 year for the Furnace. The warranty period begins on the date of the shipment. Parts, product repairs, and services are warra ...

Table of Contents

1 Before You Start . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Symbols Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.3 Safety Information . . . . ...

Set-point Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

6.4 Scan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 6.4.1 Scan Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 6.4. ...

IEEE-488 Communication . . . . . . . . . . . . . . . . . . . . . 41

7.2.1 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 7.2.2 IEEE-488 Interface Address . . . . . . . . . . . . . . . . . . . . . . . . . . 41 7.3 Interface Commands . . ...

Figures and Tables

Table 1 International Electrical Symbols . . . . . . . . . . . . . . . . . . . . . 1 Figure 1. Furnace Core Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Figure 2 HTPRT control probe and cutout thermocouple wire routing and heat pipe ground wire placement.. . . . . . . ...

Before You Start

1.1 Introduction The Hart Scientific 9116A Furnace has a temperature range of 550°C to 1100°C and is designed for use in achieving aluminum, silver, or copper freez- ing point measurements. The furnace utilizes a sodium heat pipe to maintain a uniform temperature over the length of the metal freeze point cell. The temperature controller ...

Hot Surface (Burn Hazard)

Read the User’s Manual (Important Information) Off On Canadian Standards Association OVERVOLTAGE (Installation) CATEGORY II, Pollution Degree 2 per IEC1010-1 re- fers to the level of Impulse Withstand Voltage protection provided. Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment t ...

• DO NOT connect this unit to a non-grounded, non-polarized outlet.

• DO USE a ground fault interrupt device. • HIGH VOLTAGE is used in the operation of this equipment. SEVERE INJURY OR DEATH may result if personnel fail to observe safety pre- cautions. Before working inside the equipment, turn power off and dis- connect power cord. • If this equipme ...

• The furnace generates extreme temperatures. Precautions must be taken to

prevent personal injury or damage to objects. Probes may be extremely hot when removed from the furnace. Cautiously handle probes to prevent personal injury. Carefully place probes on a heat resistant surface or rack until they are at room temperature. SPRT’s should be placed in a ...