IBM Power System 5105-22E Manual 

File Specifications

Brand: IBM
Category: Control Panel
Model: Power System 5105-22E (Manual ), prhuIOxLc2Ar2
File Type: PDF
File Size: —
Pages: 98 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (98 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 14/07/2026).

Read Online

Read the IBM Power System 5105-22E Manual  online using the built-in PDF viewer.

Key Pages of Document

Before using this information and the product it supports, read the information in “Safety notices” on

page v, “Notices” on page 73, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. This edition applies to IBM® Power Systems servers that contain the POWER9™ processor and to all associated models. © Copyright International Business Machines Corporation 2018, 2020. US Government ...

Safety notices may be printed throughout this guide:

• DANGER notices call attention to a situation that is potentially lethal or extremely hazardous to people. • CAUTION notices call attention to a situation that is potentially hazardous to people because of some existing condition. • Attention notices call attention to the possibility of damage to a program, device, system, or data. World Trade safety information Several countries re ...

– For racks with a DC power distribution panel (PDP), connect the customer’s DC power source

to the PDP. Ensure that the proper polarity is used when attaching the DC power and DC power return wiring. • Connect any equipment that will be attached to this product to properly wired outlets. • When possible, use one hand only to connect or disconnect signal cables. • Never turn on any equipment when there is evidence of fire, water, or structural da ...

• Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top

of rack-mounted devices. In addition, do not lean on rack mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). • Stability hazard: – The rack may tip over causing serious personal injury. – Before extending the rack to the installation position, read the installation instructions. – Do not put ...

CAUTION: Removing components from the upper positions in the rack cabinet improves rack

stability during relocation. Follow these general guidelines whenever you relocate a populated rack cabinet within a room or building. • Reduce the weight of the rack cabinet by removing equipment starting at the top of the rack cabinet. When possible, restore the rack cabinet to the configuration of the rack cabinet as you received it. If this configuration is not kn ...

DANGER: Rack-mounted devices are not to be used as shelves or work spaces. Do not place

objects on top of rack-mounted devices. In addition, do not lean on rack-mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). Stability hazard: • The rack may tip over causing serious personal injury. • Before extending the rack to the installation position, read the installation instructions. • Do not put ...

DANGER: Multiple power cords. The product might be equipped with multiple AC power cords or

multiple DC power cables. To remove all hazardous voltages, disconnect all power cords and power cables. (L003) (L007) CAUTION: A hot surface nearby. (L007) x Power Systems: Power Systems: Control panel ...

CAUTION: Hazardous moving parts nearby. (L008)

All lasers are certified in the U.S. to conform to the requirements of DHHS 21 CFR Subchapter J for class 1 laser products. Outside the U.S., they are certified to be in compliance with IEC 60825 as a class 1 laser product. Consult the label on each part for laser certification numbers and approval information. CAUTION: This product might contain one or more of the following devices: CD-ROM drive, DVD- ...

• LIFT TOOL intended for use to assist, lift, install, remove units (load) up into rack elevations. It is

not to be used loaded transporting over major ramps nor as a replacement for such designated tools like pallet jacks, walkies, fork trucks and such related relocation practices. When this is not practicable, specially trained persons or services must be used (for instance, riggers or movers). • Read and completely understand the contents of LIFT TO ...

Freewheeling will cause uneven cable wrapping around winch drum, damage cable, and may

cause serious injury. • This TOOL must be maintained correctly for IBM Service personnel to use it. IBM shall inspect condition and verify maintenance history before operation. Personnel reserve the right not to use TOOL if inadequate. (C048) Power and cabling information for NEBS (Network Equipment-Building System) GR-1089-CORE The following comments apply to the IBM ...

Control panel and control panel display for the

5105-22E, 9008-22L, 9009-22A, 9009-22G, or 9223-22H Find information about removing and replacing a control panel and control panel display for the 5105-22E, IBM Power® System L922 (9008-22L), IBM Power System S922 (9009-22A and 9009-22G), or IBM Power System H922 (9223-22H) server. Figure 1 on page 1 shows the control panel (A) and the control panel display (B). Figure 1. Control panels You must have at lea ...

Preparing the 5105-22E, 9008-22L, 9009-22A, 9009-22G, or 9223-22H system to remove

and replace the control panel To prepare the system to remove and replace a control panel, complete the steps in this procedure. Procedure 1. Identify the part and the system that you are working on. For instructions, see Identifying a part (www.ibm.com/support/knowledgecenter/POWER9/p9haj/sal.htm). Use the blue identify LED on the enclosure to locate the system. Ensure that ...

Figure 2. Removing the power cords

(L003) or or Control panel and control panel display for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, or 9223-22H 3 ...

DANGER: Multiple power cords. The product might be equipped with multiple AC power cords

or multiple DC power cables. To remove all hazardous voltages, disconnect all power cords and power cables. (L003) 4. Remove the front cover by pulling it away from the system. The cover has indentations (A) where you can hold it more easily. See Figure 3 on page 5. 4 Power Systems: Power Systems: Control panel ...

Figure 3. Removing the front covers

5. Open the side latches (A) and pull the latches to slide the system unit fully into the service position, until the slides click and hold the system unit securely. Ensure that the screws inside the latches are not secured to the rack. Remove the hook-and-loop fasteners that secure the cable management arms. Ensure that the cable management arms can move freely. Ensure that the cables at the rear of the system do not ca ...

Figure 4. Releasing the side latches

6. Attach the electrostatic discharge (ESD) wrist strap. Your system has an ESD jack on the front and on the rear of the system as shown in the following figure. Plug the ESD wrist strap into the ESD jack. Attention: • Attach an electrostatic discharge (ESD) wrist strap to the front ESD jack, to the rear ESD jack, or to an unpainted metal surface of your hardware to prevent the electrostatic discharge from damaging yo ...