FOREWORD We would like to thank you for purchasing a Firebird Enviroair Air Source Heat Pump. This instruction manual is produced for the reference and guidance of the end user. This guide is aimed at providing a basic understanding of the heat pump system installed within your property. Please always refer to the latest manual on our website: ww ...
FIREBIRD ENVIROAIR HEATING SYSTEMS Running patterns and flow temperatures A traditional boiler system is usually oversized for the property and is designed to work at a high flow temperature (80°C). The boiler will generally run for limited periods of time during the day. In contrast, the heat pump will have been sized to match much more closely ...
Weather compensation The heat pump measures the outdoor temperature and adjusts the temperature of water being fed to the heating system. The warmer it is outside the lower the flow temperature and so the higher the efficiency of the heat pump. This method of operation is called ‘weather compensation’ and is critical to enabling the heat pump ...
PC-controller The controller is used to control your heating system and has been set up during commissioning. The temperature in the house can be adjusted by using the room stats. provided. *More information page 8 (Controller Symbols). Running the system economically Heat pump set-up The heat pump should be setup by the commissioning engineer. I ...
Firebird System Efficiency First year of use During the first year after a house has been built, the energy required to heat the house can be higher than normal due to the need to dry out the fabric of the building. • Leaving windows/doors open When leaving windows and doors open, room temperatures will fall below the desired set temperature po ...
Commissioning Similar to all heating systems, the Enviroair heating system must be commissioned by a competent, qualified engineer. This will ensure that: • the heat pump is fine tuned to best suit your heating system so that it operates efficiently. • The warranty is activated. Preventive maintenance of equipment The Enviroair heating system ...
PC- CONTROLLER The PC-Controller has to be configured during commissioning for your heating system. No settings should be altered as this may have a direct impact on the operation of your system and invalidate the warranty. Definition of the switches 1. Liquid Crystal display Screen where controller software is displayed. 2. Ok button To select t ...
Controller Icons Icon Name Description Mode Heating mode is enabled Circuit Status Demand -OFF Heating circuit is turned off (domestic hot water gets priority over heating) No demand Heating circuit load is turned on Low demand Heating circuit is on low load 0 - 33% Medium demand Heating circuit is on medium load 33 - 66% High demand Heating cir ...
COMMON QUESTIONS AND ANSWERS How do I raise/lower the temperature in the house? To increase/lower the temperature in the house, simply raise/lower the temperature on each room stat. We recommend raising/lowering the temperature of the room stat. by increments of 1°C when fine tuning the temperature. Once selected, the heat pump will maintain th ...
⚠️ Download Safety
The Heat Pump Operation & user’s manual (14 pages) is completely safe to download (last scan date: 04/07/2026).