Comelit UT1020 Technical Manual
Text of the manual
Audio/video module for Simplebus1 Ultra
Art. UT1020
Simplebus1 Ultra remote camera audio module
Art. UT1010VC
TECHNICAL
MANUAL
This Comelit product has been designed and manufactured for use in the creation of audio and video communication
systems in residential, commercial, industrial and public buildings.
Installation
All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with
careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.
Wires
Disconnect the power supply before carrying out any operations on the wiring.
Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system
manual.
We advise against running the system wires through the same duct as power cables (230V or higher).
Safe usage
To ensure Comelit products are used safely:
• carefully observe the indications provided in the Manuals / Instruction sheets,
• make sure the system created using Comelit products has not been tampered with / damaged.
Service
Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance
with the indications provided in the Manuals / Instruction sheets.
Any repairs must be carried out:
• for the products themselves, exclusively by Comelit Group S.p.A.,
• for the systems, by qualified technical personnel.
Disclaimer
Comelit Group S.p.A. does not assume any responsibility for
• any purpose other than the intended use,
• failure to observe the indications and warnings contained in this Manual / Instruction sheet.
Comelit Group S.p.A. reserves the right to change the information provided in this Manual / Instruction Sheet at any
time and without prior notice.
Table of contents
Warning............................................................................................. 2
Description........................................................................................ 4
UT1020.......................................................................................................4
UT1010VC..................................................................................................4
Installation notes (Art. UT1020)....................................................... 6
Technical specifications.................................................................. 7
Art. UT1020................................................................................................7
Art. UT1010VC...........................................................................................8
Installation......................................................................................... 9
Flush-mounted installation composition table.....................................9
Surface-mounted installation composition table.................................9
Flush-mounted installation............................................................ 10
Removing nameplates (2A) / module (2B).............................................11
Installation with side-by-side boxes......................................................12
Wall-mounted installation.............................................................. 13
Optional........................................................................................... 13
Removing nameplates (2A) / module (2B).............................................14
Installation with side-by-side boxes......................................................15
Connections.................................................................................... 16
Connections for UT1020, UT1010VC.....................................................16
Variants....................................................................................................16
Remote camera connection (Art. UT1010VC only)...............................17
Module connection......................................................................... 18
Connection of button modules Art. UT9200......................................18
Connection of Touchscreen module Art. UT9270..............................18
Connection of number keypad module Art. UT9279M......................19
Programming.................................................................................. 20
Configuring the button type to maintain during normal operation
(single/dual).............................................................................................20
Address button modules........................................................................20
Program call addresses..........................................................................20
Smart programming of consecutive addresses.......................... 21
Programming of specific addresses............................................. 22
Special programming via DIP Switch........................................... 23
Special programming table....................................................................24
Twilight sensor................................................................................ 26
Camera LED lighting and button backlighting management..............26
Checking twilight sensor operation......................................................27
Adjusting the brightness of the button LEDs and the camera light...28
Light-me function........................................................................... 29
Light-me function behaviour on the basis of the LED backlighting
mode........................................................................................................29
Replacing the audio/video module with programming restore
backup............................................................................................. 30
Configuring via PC......................................................................... 31
Errors and indications.................................................................... 31
System performance and layouts................................................. 31
Addressing table............................................................................. 32
Audio/video module for Ultra entrance panel, Simplebus1 system. For use in systems with power supply unit art.1595
and art. 4888C. Wide-angle colour video camera (field of vision: 120° horizontal, 90° vertical)
UT1010VC
Audio module designed for connection of an analogue remote camera with PAL standard for Ultra entrance panel,
Simplebus1 system. To be used in systems with power supply unit art. 1595 and art. 4888C.
Easy to install and simple to configure, thanks to the smart programming of call buttons.
Twilight sensor for automatic nameplate backlighting switch-off during daylight hours.
Omnidirectional digital microphone and double loudspeaker for high-fidelity audio.
Audio-visual indications for disabled individuals assistance request can be activated via programming.
Facility for 2 call buttons. To be finished with cap, single button or dual button made using aluminium or professional
grade plastic treated to prevent yellowing and dulling.
Adjustment and programming can take place without removing the module.
Dimensions: 100 x 90 x 35 mm.
ULTRA: the new and most technologically advanced entrance panel offering maximum ease of installation.
Available in flush-mounted (10 mm protrusion from the wall) or surface-mounted (just 35 mm protrusion from the wall)
variants.
4. 5. 6.
7.
9.
10.
11.
12.
8.
1.
2.
2.
16.
17.
1. Indicator LEDs
call sent (green) / system busy (red)
lock-release enabled
communication enabled
2. Loudspeakers
3. Colour video camera (with Art. UT1020 only)
4. Speaker volume control
5. S1 Button programming selector
6. S2 Special programming selector
7. Micro USB input for programming via computer
8. Twilight sensor
9. Addressing and programming Dip Switches
10. Microphone volume control
11. Programming confirmation button
12. Digital microphone
Use screwdriver supplied
13. Terminal block for connection:
RTE programmable RTE (local lock-release
input) or DO input (door open indication)
GND RTE or DO input reference negative
IF door lock reference negative
NO NC COM relay contacts
V- V+ power supply
LL bus line connection
14. Ethernet terminal block, only for use in case of additional
modules with LAN
15. Connector for additional modules with LAN
16. 17. Connector for additional module connection
18. Remote camera connection (with Art. UT1010VC only):
in flush-mounted installations, use the terminal;
in surface-mounted installations, solder the wires
and use the heat-shrink sheath.