Field mounted Temperature Transmitters

TTF350 Operating Instructions OI/TTF350-EN 08.2007 Manufacturer: ABB Automation Products GmbH Borsigstraße 2 63755 Alzenau Germany Tel.: +49 551 905-534 Fax: +49 551 905-555 [email protected] © Copyright 2007 by ABB Automation Products GmbH Subject to change without notice This document is protected by copyright. It assists the user with the safe and efficient operation

General Safety Information ............................................................................................................................6

1.2 Intended use..................................................................................

ABB TTF350 Configuration options / Communication .......................................................................................................33

7.2 Configuration via FDT/DTM technology..........................................................................

14.3 Power supply (polarity safe).........................................................................................................................67

15 General information ..........................................................................................................................................67 15.1 Ambient conditions.....................................................................................

ABB TTF350 General Safety Information

The “Safety” chapter provides an overview of the safety aspects to be observed for the operation of the device. The device is built based on state-of-the-art technology and is operationally safe. It was tested and left the factory in a proper state. The requirements in the manual as well as the documentation and certificates must be observed and followed in order to maintain this stat

A use contrary to the device’s stipulated use, disregarding of this manual, the use of under-

qualified personnel as well as unauthorized alterations excludes the manufacturer of liability from any resulting damages. The manufacturer’s warranty expires. 1.5 Labels and symbols 1.5.1 Symbols and warnings Danger – One of these symbols in conjunction with the �

ABB TTF350 The model plate is located on the transmitter housing.

A00186 Automation Products GmbH Alzenau Germany 2006 TTF350 U = +11... 42 V, I = 4 ... 20 mA, HART Cfg. 2 x TC; Type K; 0°C ... 300°C T = -40°C ... +85°C S a a O-Code: TTF350-Y0C4/OPT 8323455772 Ser.-No: 123456789012 3 2 1 4 5 6 7 12 13 11 10 9 8 HW-Rev: 1.05 SW-Rev: 01.00.00 IP6X, NEMA 4X 14 0102 15 Fig. 1 1 Manufacturer of transmitter 2 Order code wit

ABB TTF350 Use the original packaging or a suitably secure packaging for returning the device for repair or

for recalibration. Include the properly filled out return form (see attachment) with the device. According to EC guidelines for hazardous materials, the owner of hazardous waste is responsible for its disposal or must observe the following regulations for its shipping: All delivered devices to ABB Automation Pr

1.11 Electrical installation safety information

The electrical connection may only be performed by authorized specialist personnel according to the electrical plans. Observe the electrical connection information in the manual, otherwise the electrical protection can be affected. The secure isolation of contact-dangerous electrical circuits is only guaranteed when the connected devices fulfil the requirements of the DIN VDE 010

ABB Transmitter Owners Instructions: