AirCom R250 Operating Manual
Text of AirCom R250 Operating Manual
1. Intended Use
Line or outlet pressure regulators- /reducer for Air, gases and liquids which is designed to
effect reduction to a downstream pressure independent of the flow rate. Not for use as a
flow controller or as a shut-off valve. The regulators from series R250 are self-contained, spring loaded pressure
reducing regulators.
Oil and grease must never be used at gas control units. Oil and grease ignite easily and can intensely react with
some gases under pressure. In special cases greases can be used, which are specified for the corresponding
application.
The use of AirCom regulator for oxygen applications is permitted only with signed units.
Special safety instructions for
An internal filter is provided only to stop random contamination resulting from the installation of the regulator; an
auxiliary upstream filter is recommended for use in all but the cleanest of media. Gaseous media should be free of
excessive moisture to prevent icing of the regulator at high flow rates.
4.3 Operation
Controlled outlet pressure settings
When performing necessary corrective action in the following operations, refer to the "Maintenance" section for the
necessary procedure.
1. Problem:
The regulated pressure continues to increase after lock up without a change in control knob position.
Possible cause: Valve seat needs replacement
2. Problem:
Leakage through or around edge of bonnet
Possib