ESAB EPP-200 Instruction Manual

Specifications

Brand: ESAB
Category: Cutter
Model: EPP-200
File Type: PDF
File Size: —
Pages: 52

Read Online

Read the ESAB EPP-200 Instruction Manual online using the built-in PDF viewer.

Text of the manual

This equipment will perform in conformity with the description thereof contained in this manual and accompa-

nying labels and/or inserts when installed, operated, maintained and repaired in accordance with the instruc- tions provided. This equipment must be checked periodically. Malfunctioning or poorly maintained equipment should not be used. Parts that are broken, missing, worn, distorted or contaminated should be replaced imme- diately. Should such repair or replacement become necessary, the manufacturer recommends that a telephone or written request for service advice be made to the Authorized Distributor from whom it was purchased. This equipment or any of its parts should not be altered without the prior written approval of the manufacturer. The user of this equipment shall have the sole responsibility for any malfunction which results from improper use, faulty maintenance, damage, improper repair or alteration by anyone other than the manufacturer or a ser- vice facility designated by the manufacturer. BE SURE THIS INFORMATION REACHES THE OPERATOR. YOU CAN GET EXTRA COPIES THROUGH YOUR SUPPLIER. These INSTRUCTIONS are for experienced operators. If you are not fully familiar with the principles of operation and safe practices for arc welding and cutting equipment, we urge you to read our booklet, “Precautions and Safe Practices for Arc Welding, Cutting, and Gouging,” Form 52-529. Do NOT permit untrained persons to install, operate, or maintain this equipment. Do NOT attempt to install or operate this equipment until you have read and fully understand these instructions. If you do not fully understand these instructions, contact your supplier for further information. Be sure to read the Safety Precautions be- fore installing or operating this equipment. CAUTION USER RESPONSIBILITY READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING. PROTECT YOURSELF AND OTHERS!

SAFETY .................................................................................................................................... 5

SECTION 2 DESCRIPTION ..........................................................................................................................................................7 SECTION 3 INSTALLATION ......................................................................................................................................................13 SECTION 4 OPERATION ............................................................................................................................................................21 TABLE OF CONTENTS

DECLARATION OF CONFORMITY

According to The Low Voltage Directive 2006/95/EC of 12 December 2006, entering into force 16 January 2007 The EMC Directive 2004/108/EC FÖRSÄKRAN OM ÖVERENSSTÄMMELSE Lågspänningsdirektivet 2006/95/EG från 12 december 2006, ikrafsat 16 januari 2007 EMC-Direktivet 2004/108/EG Type of equipment Materialslag Plasma Cutting Console Brand name or trade mark Fabrikatnamn eller varumärke ESAB Type designation etc. Typbeteckning etc. EPP-200, (0558004315) Manufacturer or his authorised representative established within the EEA Name, address, telephone No, telefax No: Tillverkarens namn, adress, telefon, telefax: ESAB AB Esabvägen, SE-695 81 Laxå, Sweden Phone: +46 586 81000, Fax: +46 584 411 924 The following harmonised standard in force within the EEA has been used in the design: Följande harmoniserande standarder har använts i konstruktionen: EN 60974-1, Arc welding equipment – Part 1: Welding power sources EN 60974-10, Arc welding equipment – Part 10: Electromagnetic compatibility (EMC) requirements Additional information: / Tilläggsinformation: Restrictive use, Class A equipment, intended for use in locations other than residential By signing this document, the undersigned declares as manufacturer, or the manufacturer’s authorised representative established within the EEA, that the equipment in question complies with the safety requirements stated above. Genom att underteckna detta dokument försäkrar undertecknad såsom tillverkare, eller tillverkarens representant inom EES, att angiven materiel uppfyller säkerhetskraven angivna ovan. Date / Datum Laxå 2009-02-18 Signature / Underskrift Position / Befattning Global Director Equipment and Automation Kent Eimbrodt Clarification

Users of ESAB welding and plasma cutting equipment have the ultimate responsibility for ensuring that anyone

who works on or near the equipment observes all the relevant safety precautions. Safety precautions must meet the requirements that apply to this type of welding or plasma cutting equipment. The following recommendations should be observed in addition to the standard regulations that apply to the workplace. All work must be carried out by trained personnel well acquainted with the operation of the welding or plasma cutting equipment. Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipment. 1. Anyone who uses welding or plasma cutting equipment must be familiar with: - its operation - location of emergency stops - its function - relevant safety precautions - welding and / or plasma cutting 2. The operator must ensure that: - no unauthorized person stationed within the working area of the equipment when it is started up. - no one is unprotected when the arc is struck. 3. The workplace must: - be suitable for the purpose - be free from drafts 4. Personal safety equipment: - Always wear recommended personal safety equipment, such as safety glasses, flame proof clothing, safety gloves. - Do not wear loose fitting items, such as scarves, bracelets, rings, etc., which could become trapped or cause burns. 5. General precautions: - Make sure the return cable is connected securely. - Work on high voltage equipment may only be carried out by a qualified electrician. - Appropriate fire extinquishing equipment must be clearly marked and close at hand. - Lubrication and maintenance must not be carried out on the equipment during operation.

WELDING AND PLASMA CUTTING CAN BE INJURIOUS TO YOURSELF AND

OTHERS. TAKE PRECAUTIONS WHEN WELDING OR CUTTING. ASK FOR YOUR EMPLOYER’S SAFETY PRACTICES WHICH SHOULD BE BASED ON MANUFACTURERS’ HAZARD DATA. ELECTRIC SHOCK - Can kill. - Install and earth (ground) the welding or plasma cutting unit in accordance with applicable standards. - Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing. - Insulate yourself from earth and the workpiece. - Ensure your working stance is safe. FUMES AND GASES - Can be dangerous to health. - Keep your head out of the fumes. - Use ventilation, extraction at the arc, or both, to take fumes and gases away from your breathing zone and the general area. ARC RAYS - Can injure eyes and burn skin. - Protect your eyes and body. Use the correct welding / plasma cutting screen and filter lens and wear protective clothing. - Protect bystanders with suitable screens or curtains. FIRE HAZARD - Sparks (spatter) can cause fire. Make sure therefore that there are no inflammable materials nearby. NOISE - Excessive noise can damage hearing. - Protect your ears. Use earmuffs or other hearing protection. - Warn bystanders of the risk. MALFUNCTION - Call for expert assistance in the event of malfunction. READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING. PROTECT YOURSELF AND OTHERS! WARNING

The EPP-200 Power Console is designed for mechanized plasma

applications. It can be used with other ESAB products such as the PT-24 and PT-600 torches, an optional plumbing box and a remote set-up pendant. t UP"NQFSFTDVUUJOHDVSSFOUSBOHF t 'PSDFEBJSDPPMFE t 4PMJETUBUF%$QPXFS t *OUFHSBMXBUFSDPPMFS t *OQVUWPMUBHFQSPUFDUJPO t -PDBMPSSFNPUFGSPOUQBOFMDPOUSPM t 5IFSNBMTXJUDIQSPUFDUJPOGPSNBJOUSBOTGPSNFSBOE power semiconductor components t -&%TUBUVTUSPVCMFTIPPUJOH 2.1 Introduction 2.2 General Specifications EPP-200 Power Console (0558004315): OUTPUT (100% duty cycle) Voltage ......................................................................................................... 160VDC Current range DC .................................................................................50A to 200A Power ................................................................................................. 8000 W to 32000 W Open Circuit Voltage (OCV) .................................................................. 325VDC INPUT Voltage (3-phase) ..............................................................200/230/380/415/460/575 Volts Current (3-phase) ...............................................................115/100/60/55/50/40 Amperes 'SFRVFODZ ....................................................................................................50/60Hz KVA .................................................................................................................39.8 kW Power .............................................................................................................37.8 kW 1PXFS'BDUPS ...................................................................................................95% *OQVU'VTF .................................................................................. See Section 3, Installation

Electric Shock Can Kill!

Use of torches not designed for this console could result in a haz- ardous electric shock. Use only torches designed for the EPP-200 Console. WARNING 2.3 Dimensions and Weight 44 in. (1100mm) 42in. (1050mm) 22in. (550mm) Weight = 725 lbs. (330 kg) SECTION 2 DESCRIPTION

2.4 EPP-200 Options and Accessories

Options 5 ft. (1.5m) 10 ft. (3.0m) 20 ft. (6.1m) 25 ft. (7.6m) 30 ft. (9.1m) 40 ft. (12.2m) 50 ft. (15.2m) 75 ft. (22.9m) 100 ft. (30.5m) 125 ft. (38.1m) 150 ft. (45.7m) * Cooling Water Hoses (2) Console to Plumbing Box Control Cable Plumbing Box to Console Pilot Arc Lead Plumbing Box to Console Power Lead Console to Plumbing Box 0558003979 0558003980 0558003981 33132 0558003982 0558003983 33133 (4495019) 33134 (4495020) 33135 (4495021) 33136 (4495022) 0558003984 N / A N / A N / A 0558004651 N / A N / A 0558004652 0558004653 0558004654 0558003978 0558004655 0558003985 0558003986 0558003987 33303 0558003988 0558003989 33304 (4495034) 33305 (4495035) 33306 (4495036) 33307 (4495037) 0558003990 0558003991 0558003992 0558003993 22001 (4495038) 0558003994 0558003995 22002 (4495039) 22003 (4495040) 22004 (4495041) 22005 (4495042) 0558003996 SECTION 2 DESCRIPTION NOTE: Part Numbers in parenthesis apply to "CE"/European units only. * Use with one adaptor fitting (41V12) included with unit.

2.5 Gas Hoses

Gas Type 25 ft. 50 ft. 75 ft. 100 ft. 125 ft. (7.6m) (15.2m) (22.8m) (30.4m) (38.1m) Nitrogen (clear) 33122 33123 33124 33125 33126 Oxygen (clear - USA) 33117 33118 33119 33120 33121 Oxygen (blue - Euro) 0558002973 0558002974 0558002975 0558002976 0558002977 Argon/Hydrogen (H-35) (1) 33122* 33123* 33124* 33125* 33126* Air (clear - USA) 33122** 33123** 33124** 33125** 33126** Air (black - Euro) (2) 0558002978** 0558002979** 0558002980** 0558002981** 0558002982** Note: * = Requires adapter P/N 19X54 (4494001) (order separately) ** = Requires adapter P/N 74S76 (0558004057) (order separately) 2.6 Gas Regulators Station Regulator Cylinder Regulator Nitrogen .....................................................19155 ............................................998343 Oxygen .......................................................19151 .............................................998336 Argon/Hydrogen (H-35) .......................19153 .............................................998341 Air .................................................................30338 (4492008) .......................N/A A separate start gas regulator is always required: t 'PSBJSQMBTNBVTFBJSTUBSUHBT t 'PSPYZHFOPSOJUSPHFOVTFOJUSPHFOTUBSUHBT t 'PS) BSHPOIZESPHFO )PSOJUSPHFOTUBSUHBT A total of 3 regulators will be required (plasma, start and secondary). When using a plumbing box: t (BTIPTFTGSPNTVQQMZDZMJOEFSTHPEJSFDUMZUPUIF plumbing box. t $POTPMFHBTNBOJGPMEJTOPUVTFE NOTICE NOTICE SECTION 2 DESCRIPTION NOTE: Part Numbers in parenthesis apply to "CE"/European units only.

2.7 Basic Packages

The EPP-200 system is available as a pre-engineered package or can be ordered as individual parts as listed. Basic Packages include: t &11$POTPMF t 1MBTNB5PSDI t "QQSPQSJBUFSFHVMBUPSTGPSUIFHBTFTJOEJDBUFE t (BTIPTFTGSPNSFHVMBUPSTUPDPOTPMF t 5PSDIDPPMBOU Torch Coolant (25%) – 1 gallon (3.8 L) P/N 0558004297 25% PG coolant improves electrode life in applications using oxygen or BJSDVUHBTCVUPOMZQSPWJEFTGSFF[FQSPUFDUJPOEPXOUP¡' ¡$ 5PSDI$PPMBOU  oHBMMPO - 1/'  &(DPPMBOUQSPWJEFTGSFF[FQSPUFDUJPOEPXOUP¡' (-40.0° C) SECTION 2 DESCRIPTION NOTE: Part Numbers in parenthesis apply to "CE"/European units only.

Failure To Follow Instructions Could Lead To Death,

Injury Or Damaged Property 'PMMPXUIFTFJOTUSVDUJPOTUPQSFWFOUJOKVSZPSQSPQFSUZEBNBHF You must comply with local, state and national electrical and safety codes. WARNING Use Lifting Eye When Hoisting From Overhead Use safe practices when transporting with overhead method. Unit weighs over 700 lbs (318 kg). Use approved straps or cables in good condition. CAUTION 3.2 Unpacking t *OTQFDUGPSUSBOTJUEBNBHFJNNFEJBUFMZVQPOSFDFJQU t 3FNPWFBMMDPNQPOFOUTGSPNTIJQQJOHDPOUBJOFSBOE check for loose parts in container. t *OTQFDUMPVWFSTGPSBJSPCTUSVDUJPOT

Do Not Restrict Air Flow

Restricting intake air with any type of filter on or around the Plasma console will result in overheating and may void the warranty. 3.3 Placement t "NJOJNVNPGGU N DMFBSBODFGPSDPPMJOHBJSøPX t 1MBOGPSUPQQBOFMBOETJEFQBOFMTIBWJOHUPCFSFNPWFE for maintenance, cleaning and inspection. t -PDBUFUIF&11SFMBUJWFMZDMPTFUPBQSPQFSMZGVTFE electrical power supply. t ,FFQBSFBCFOFBUIQPXFSTPVSDFDMFBSGPSDPPMJOHBJS flow. t &OWJSPONFOUTIPVMECFSFMBUJWFMZGSFFPGEVTU GVNFTBOE excessive heat. These factors will affect cooling efficiency. Conductive Dust And Dirt Inside Power Source May Cause Arc Flash Over Equipment damage may occur. Electrical shorting may occur if dust is allowed to buildup inside power source. See maintenance section. Electric Shock Can Kill! Provide maximum protection against electrical shock. Before any connections are made inside the machine, open the line wall disconnect switch to turn power off. 3.4 Input Connections to Console Plasma Console SECTION 3 INSTALLATION

3.4.1 Primary Power Specifications

EPP-200 is a 3-phase unit. Input power must be provided from a line (wall) disconnect switch that contains fuses or circuit breakers in accordance to local or state regulations. Recommended input conductor and line fuse sizes: Dedicated power line may be necessary. EPP-200 is equipped with line voltage compensation but to avoid impaired performance due to an overloaded circuit, a dedicated power line may be required. 4J[FTQFS/BUJPOBM&MFDUSJDBM$PEFGPSB¡$ ¡' SBUFEDPQQFS DPOEVDUPST!¡$ ¡' BNCJFOU/PUNPSFUIBOGPVSDPOEVDUPST in raceway or cable. Local codes should be followed if they specify sizes other than those listed above. Input current values given in this table are at maximum output power (32kW) 200 amps at 160VDC. Rated Load Input and Ground conductor* CU/AWG Time delay 'VTFTJ[F (amperes) Volts Amperes 200/208 115 1 150 230 100 2 125 380 60 4 80 415 55 6 70 460 50 6 70 575 40 8 60 SECTION 3 INSTALLATION

3.4.2 Primary Power Hookup Procedure

The following procedure explains the proper installation steps for connecting primary electrical power to the plasma console. NOTE: Safety codes specify the power ground wire be the last connection to break should the cable be pulled out of the unit. When preparing the cable for connection, make the ground wire 6 inches (152mm) longer than the three pr primary wires. 1. Ensure input power cable is disconnected from all electrical sources. 2. Remove right side panel (as viewed from front of console). 3. Route input power cable through the strain relief located at the rear panel. 4. Pull input power cable through the strain relief to allow cable wires sufficient length to connect to main contactor. Tighten strain relief to ensure input power cable is secured. 5. Connect input power cable ground wire to the ground lug provided above TB2 (7 position terminal block). 6. Connect three power leads of input power cable to terminals located atop the main contactor. Secure the leads by tightening each screw. 7. Connect jumper power cables from bottom of the main contactor to proper input voltage marked on auto transformer. Unit is factory set for 575V as shown at the left. 8. Connect jumper on TB2 to proper input voltage. This 7 position terminal block jumper is factory set to 575V. Input Power Jumper Connection Ensure each input power jumper cable is connected to correct input voltage on autotransformer and on TB2. 'BDUPSZXJSFEGPS7PMUT CAUTION Input Power Cable Strain Relief Main Contactor Ground Connection 7 Position Terminal Block Auto Transformer 'BDUPSZXJSFE for 575 volts SECTION 3 INSTALLATION

9. Connect input conductors to line (wall) disconnect.

10. Replace side panel. Replace only if all connections have made. Output connections require this panel to be removed. 11. Connect the other end of work cable to workpiece or cutting table. Connection must be made to a clean, exposed metal surface, free of paint, rust, mill scale, etc. Electric Current Is Hazardous. It is important to have a good earth ground connected to the workpiece or cutting table. WARNING Work ground to work piece Work ground to cutting table SECTION 3 INSTALLATION

3.5 Connecting Plasma Torches to EPP-200 Console and Options

3.5.1 EPP-200 Output Cables, Hoses and Adapters (customer supplied) EPP-200: Lengths vary depending on system. t $PPMBOU3FUVSO t $PPMBOU4VQQMZ t 1JMPU"SD$BCMF t &MFDUSPEF$BCMF t 4IJFME(BT EJSFDUMZUPUIF1MVNCJOH#PY t 4UBSU(BT EJSFDUMZUPUIF1MVNCJOH#PY t $VU(BT EJSFDUMZUPUIF1MVNCJOH#PY t 8PSL$BCMF t 1FOEBOU$BCMF JGQFOEBOUPQUJPOJTPSEFSFE See Description, Section 2 for part numbers. A remote SETUP Panel option is available on Avenger 1 and larger ESAB cut cutting machines. This panel operates the same as the pendant. Refer to your machine manual for replacement parts. SECTION 3 INSTALLATION

Commercial Antifreeze Will Cause Torch To

Malfunction. Use special torch coolant. Do to high electrical conductivity, DO NOT use tap water or commercial automotive type antifreeze for torch cooling. A specially formulated torch coolant is REQUIRED. This coolant also protects GSPNGSFF[JOHUP¡$ ¡'  Operating the unit without coolant will cause permanent damage to the coolant pump. Check coolant level frequently. Remove coolant fill cap at front console and fill coolant tank with 4 gallons (15 liters) of plasma torch coolant. t %POPUöMMBCPWFJOEJDBUFENBYJNVNMFWFM t 3FJOTUBMMDBQ CAUTION Electric Current Is Hazardous. It is important to have a good earth ground connected to the workpiece or cutting table. WARNING 3.6 Coolant Installation $PPMBOU'JMM$BQ SECTION 3 INSTALLATION

4.1 Introduction – Operational Safety

Electric Shock Can Kill! Disconnect current supply at wall disconnect before servicing console, torch or plumbing box. t %POPUPQFSBUFDPOTPMFPSQMVNCJOHCPYXJUIBOZDPWFST removed/open. t %POPUUPVDIBOZUPSDIGSPOUFOEQBSUTXJUIQPXFSPO t %POPUBUUFNQUUPTFSWJDFBOZQPSUJPOPGUIJTQMBTNB system unless power has been disconnected at the wall disconnect. WARNING This equipment can be hazardous if not properly operated and maintained. Read and understand all equipment literature and warning labels before operating this equipment. WARNING Plasma Arc Cutting Can Be Hazardous To Eyes And Ears. t 8FBSIFBSJOHQSPUFDUJPO t 8FBSFZFQSPUFDUJPOTQFDJöDBMMZEFTJHOFEGPSBSD welding and cutting. Lenses should be at least a No. 6 or No. 7 lens shade. t 8FBSQSPUFDUJWFDMPUIJOHUPBWPJETLJOCVSOT

4.2 Operating the EPP-200 Console

4.2.1 Console Controls 1 Pilot Arc High/Low Switch 2 Cutting Voltage and Cutting Current Meters 3 Output Current Control 4 Remote/Panel Selection Switch 5 Gas Test Switch  'BVMU-JHIUT 7 Main Power Switch Pilot Arc Switch Used to select pilot arc current range when Remote / Panel Switch is in the Panel position. HIGH position is used for most cutting applications. Electrode life is adversely affected when used in high position when low is suitable. Starting may be difficult if set on low when high is required. Related to the initial torch standoff height. Cutting Voltage and Current Meters “A” meter indicates actual cutting current, 0-200 amperes “V” meter indicates actual output voltage, 0-160 VDC Output Current Control Sets the cutting current when current settings are made from the power console front panel. (The Remote/Panel switch must be in the Panel position.) Remote/Panel Switch Panel position – Output current is set by the output current control on the console front panel as described above. Remote position – Output current is set by the CNC with an analog dc signal. 1 2 3 4 5 6 7 SECTION 4 OPERATION

Gas Test Switch

Cut – Allows for setup of cut gas pressure and flow. Start/Shield – Setup of gas pressures and flows. Operate – Default position – Must be in this position for cutting. Fault Indicator Lights t Coolant Flow – Will show low coolant flow. Light will briefly show a fault when console is turned on and then go out. t Plasma Gas Pressure — fault indicator – low plasma gas pressure. Torch will not fire when illuminated. t Interlock Fault – Indicates Remote Plumbing box door is not properly closed. t P/S Temp – fault indicator – over temperature condition in the inverter power source. t P/S Fault – fault indicator – Not used. t Over/Under Voltage – fault indicator – input voltage is above or below tolerances of the power source console. Will stay shut down console until main power switch is recycled and fault is corrected. Main Power Switch Controls the input power to the fan, water cooler, inverter and interface circuitry. Light illuminates to indicate power is on. SECTION 4 OPERATION

4.3 Sequence of Operation

1. Apply power by closing the line (wall) switch. Main power light will OPUJMMVNJOBUFVOUJMDPOTPMFQPXFSTXJUDIJTUVSOFE0/'BVMUMJHIU should flash and go out. 2. Select the Panel/Remote setting. If current is controlled from cutting machine CNC, place switch to Remote position. Consult cutting machine instructions for current setting. If current is not controlled by the CNC, select Panel and set current on output current dial. 3. Check coolant level. Level must be checked with console main power JO0''QPTJUJPO$PPMBOUMFWFMNVTUGBMMJOUIFTBGFPQFSBUJOHMFWFM 4. Set pilot arc High/Low switch. Refer to cutting process data of the torch manual. 5.Turn on console power by placing power switch in ON position. White light to left of the switch will illuminate. 6. Check coolant pressure. The pressure is factory set between 80 to 90 PSI (5.5-6.2 bars) 7. Begin plasma cutting operation. This may include manually setting other options, depending on total plasma package. If using panel mode, after cutting has begun, adjust current to desired amount. Check for a fault light. If a fault light illuminates, SHUT OFF POWER IMMEDIATELY and refer to troubleshooting section. SECTION 4 OPERATION

Electric Shock Can Kill!

Open wall disconnect switch before attempting any maintenance on: t QMBTNBDPOTPMF t JOUFSDPOOFDUJOHDBCMFT Only trained personnel should perform maintenance or repairs on this equipment. 5.2 Inspection and Cleaning Frequent inspection and cleaning of the EPP-200 and related equipment are recommended for safety and proper operation. Consider the following during inspection and cleaning: t $IFDLXPSLDBCMFUPXPSLQJFDFDPOOFDUJPO t $IFDLTBGFUZFBSUIHSPVOEBUXPSLQJFDFBOEBUQPXFS source chassis. t &OTVSFDBCMFBOEIPTFTBSFOPUEBNBHFEPS  LJOLFE t &OTVSFBMMQMVHT öUUJOHT BOEHSPVOEDPOOFDUJPOTBSF tight. t $IFDLTDSFFOöMUFSJODPPMBOUQVNQ MPDBUFEJOTJEF console) periodically and flush as required.

Flying Debris Hazard.

Flying Debris Can Seriously Injure Eyes Wear protective eyewear when cleaning with compressed air. Use low pressure air only. Avoid Potential Equipment Damage Water and/or oil can accumulate in compressed air lines. Be sure UPEJSFDUUIFöSTUBJSCMBTUBXBZGSPNFRVJQNFOUUPBWPJE damaging the junction box or flow control box. t 8JUIBMMJOQVUQPXFSEJTDPOOFDUFEBOEXJUIQSPQFSFZF  BOEGBDFQSPUFDUJPO CMPXPVUUIFJOTJEFPGUIFQPXFS  TPVSDF øPXDPOUSPM BOEKVODUJPOCPYVTJOHMPXQSFTTVSF clean dry compressed air. t 1FSJPEJDBMMZCMFFEBMMXBUFSGSPNUIFBJSöMUFSSFHVMBUPS trap. SECTION 5 MAINTENANCE

5.3 Gas Manifold Pressure Switches

Newer EPP-200 consoles are equipped with nonadjustable preset gas manifold pressure switches. Older ESP-200 consoles have adjustable pressure switches. Both type switches are preset for: t QTJH CBS TIJFMEBOETUBSUHBTTXJUDIFT t QTJH CBS DVUHBTTXJUDI 5.3.1 Pressure Switch Adjustment Procedure  5VSONBJOQPXFSTXJUDI0''0'' 2. Remove right side panel 3. Turn wheel:  t$PVOUFSDMPDLXJTFUPincrease pressure  t$MPDLXJTFUPdecrease pressure 4. Replace panel. 5. Resume operation. 5.3.2 Gas Manifold with Non-adjustable Pressure Switches (reference) SECTION 5 MAINTENANCE

Electric Shock Can Kill!

Ensure all primary power to machine has been externally disconnected. 0QFOMJOF XBMM TXJUDICFGPSFBUUFNQUJOHJOTQFDUJPOPSQFSGPSNJOH XPSLJOTJEFUIFQMBTNBDPOTPMFPSQMVNCJOHCPY Capacitors Can Store High Voltages. Disconnecting plasma console does not ensure capacitors are de- energized. Ensure console capacitors are grounded after removing power and prior to performing maintenance. 6.2 Procedure 4IVUNBJOQPXFSTXJUDIPOUIFDPOTPMFUP0''QPTJUJPO %JTDPOOFDUNBJOQPXFSMJOF XBMM TXJUDI  $IFDL GPS PCWJPVT FYUFSOBM TFUUJOHT  TXJUDIFT BOE FYUFSOBM connections. *GBQSPCMFNJTGPVOE DPSSFDUBOEQSPDFFEXJUIOPSNBMPQFSBUJPOT *GOPU SFNPWFTJEFQBOFMT(Reminder: Power must be disconnected before removing any covers.) 1FSGPSNBWJTVBMJOTQFDUJPOPGJOUFSOBMDPNQPOFOUT$IFDLGPS t -PPTFPSCVSOFEXJSJOHBOEDPNQPOFOUT t 4FDVSFUFSNJOBMDPOOFDUJPOT t #VMHFEPSMFBLJOHDBQBDJUPST t 0UIFSTJHOTPGEJTDPMPSBUJPO Refer to the troubleshooting guide for identification of many problems, possible causes and remedies. Reference wiring diagrams and schematics are found in the last part of this section. 6.1 Introduction

6.3 Front Panel Fault Lights

Fault Indicator Lights t Coolant Flow – Will show low coolant flow. The light will briefly show a fault when console is turned on and then go out. t Plasma Gas Pressure — fault indicator – low plasma  HBTQSFTTVSF5PSDIXJMMOPUöSFXIFOJOEJDBUFE t Interlock Fault – Indicates Remote Plumbing box door is not properly closed. t P/S Temp – fault indicator – over temperature condition in the inverter power source. t P/S Fault – Not used. t Over/Under Voltage – fault indicator – input voltage is above or below the tolerances of the power source console. Will stay shut down console until main power switch is recycled. SECTION 6 TROUBLESHOOTING

6.4 Troubleshooting Guide

High Voltages Can Cause Serious Injury or Death! Voltages in plasma cutting equipment are high enough to cause serious injury or death. Only trained technicians should attempt diagnosis and repair of this machinery. Avoid damaging your voltmeter. Disconnect the power from the high frequency generator before DIFDLJOHWPMUBHFTJOUIFIJHIGSFRVFODZDJSDVJU SECTION 6 Troubleshooting ESP-200 Plasmarc Cutting System 6-3 6.4 Troubleshooting Guide WARNING ! High Voltages Can Cause Serious Injury or Death! Voltages in plasma cutting equipment are high enough to cause serious injury or death. Only trained technicians should attempt diagnosis and repair of this machinery. CAUTION ! Avoid damaging your voltmeter. Disconnect the power from the high frequency generator before checking voltages in the high frequency circuit. Problem Problem Problem Problem Possi Possi Possi Possible Cause ble Cause ble Cause ble Cause Corrective Action Corrective Action Corrective Action Corrective Action Power switch is ON. Power LED Power switch is ON. Power LED Power switch is ON. Power LED Power switch is ON. Power LED is OFF. Fan is OFF. Pump is is OFF. Fan is OFF. Pump is is OFF. Fan is OFF. Pump is is OFF. Fan is OFF. Pump is OFF. OFF. OFF. OFF. 1) Bad Power switch S1. 2) Open Fuse F4. 3) Open Jumper at TB2. 1) Check continuity of power switch. 2) Check Fuse F4 and related wiring 3) Check jumper and wiring of TB2 Power Power Power Power switch is ON. Power LED switch is ON. Power LED switch is ON. Power LED switch is ON. Power LED in ON. Pump is OFF. Fan is ON. in ON. Pump is OFF. Fan is ON. in ON. Pump is OFF. Fan is ON. in ON. Pump is OFF. Fan is ON. 1) Bad or open CB2. 2) Pump Motor Failed. 1) Reset CB2. Check wiring and check free rotation of pump fan. 2) Replace Pump motor Power LED is OFF. Pump is ON. Power LED is OFF. Pump is ON. Power LED is OFF. Pump is ON. Power LED is OFF. Pump is ON. Fan is ON. LEDs in power Fan is ON. LEDs in power Fan is ON. LEDs in power Fan is ON. LEDs in power modules are OFF modules are OFF modules are OFF modules are OFF 1) Bad or Open CB1. 1) a. Reset CB1 b. If CB1 fails to reset, check wiring, bad T1, or PCB1. Plasma gas fault indicator is ON Plasma gas fault indicator is ON Plasma gas fault indicator is ON Plasma gas fault indicator is ON 1) Plasma gas pressure to console is below 40 psi. 2) Bad pressure switch 3) Open wire between pressure switch and PCB1. 1) Adjust gas pressure to proper level for torch and application 2) Adjust (if adjustable type) or replace pressure switch. 3) Check wiring between PS1 & PS2 and PCB1 P1-9 and P1-10. SECTION 6 TROUBLESHOOTING

ESP-200 Plasmarc Cutting System

6-4 Problem Problem Problem Problem Possible Cause Possible Cause Possible Cause Possible Cause Corrective Action Corrective Action Corrective Action Corrective Action Power Source Temp fault Power Source Temp fault Power Source Temp fault Power Source Temp fault indicator is ON. indicator is ON. indicator is ON. indicator is ON. 1) Poor ventilation at rear of console. 2) Open thermal switch. 3) Open wire between temperature switch and PCB1 1) Make sure that there is 2 feet of clearance on each side of console. 2) With power OFF, check each thermal switch. Normal operation is: switch closed below 194!F. 3) Check wiring between temperature switches and PCB1 P1-15 and P1-16. Over/Under Voltage fault indicator Over/Under Voltage fault indicator Over/Under Voltage fault indicator Over/Under Voltage fault indicator is ON is ON is ON is ON 1) Input voltage is 15% above or below the selected console operating voltage. 2) Bad PCB1. 3) Bad PCB1 in MOD1. 4) Bad T1 in MOD1. 1) Provided input voltage must be equal to the selected console operating voltage. Change if necessary. 2) Replace PCB1. 3) Replace PCB1 in MOD1 4) Replace T1 in MOD1 Meters M1 or M2, no display. Meters M1 or M2, no display. Meters M1 or M2, no display. Meters M1 or M2, no display. 1) Bad Meter 1) Replace Meter meters M Meters M1 & M2, no display. 1) Bad PCB1. 1) Replace one meter to verify above step did not happen twice. If still not working replace PCB1. Press torch switch or send start Press torch switch or send start Press torch switch or send start Press torch switch or send start signal. signal. signal. signal. (No pilot arc or main arc transfer.) (No pilot arc or main arc transfer.) (No pilot arc or main arc transfer.) (No pilot arc or main arc transfer.) 1) Gas Test switch is in START/SHIELD or CUT positions 2) Plasma gas pressure is to LOW 3) Improper current command signal 4) LEDX on MOD1 PCB1 is not ON when torch switch is depressed or start signal sent. 5) LEDX is ON but main contactor does not close 6) LEDX is ON. Main contactor is closed. No OCV or arc transfer. 1) Place Gas Test switch in OPERATE position. 2) Set plasma gas pressure per torch or application requirements (above 40 psi) 3) IF in manual mode, panel switch must be in PANEL and P5 must be in J5 connector. If in mechanized mode, panel switch must be in REMOTE and a current signal above 0 volts must be present. P5 must be in J6 connector 4) Test tbd 5) Test tbd 6) Test tbd SECTION 6 TROUBLESHOOTING

ESP-200 Plasmarc Cutting System

6-5 Problem Problem Problem Problem Possible Cause Possible Cause Possible Cause Possible Cause Corrective Action Corrective Action Corrective Action Corrective Action LEDX on MOD1 not ON LEDX on MOD1 not ON LEDX on MOD1 not ON LEDX on MOD1 not ON LEDX on MOD2 not ON LEDX on MOD2 not ON LEDX on MOD2 not ON LEDX on MOD2 not ON LEDX on MOD2 not ON when LEDX on MOD2 not ON when LEDX on MOD2 not ON when LEDX on MOD2 not ON when torch switch is depressed or start torch switch is depressed or start torch switch is depressed or start torch switch is depressed or start signal is sent signal is sent signal is sent signal is sent Arc does not transfer to work. Arc does not transfer to work. Arc does not transfer to work. Arc does not transfer to work. (Ope (Ope (Ope (Open Circuit Voltage is between n Circuit Voltage is between n Circuit Voltage is between n Circuit Voltage is between 315 and 355. Pilot arc IS 315 and 355. Pilot arc IS 315 and 355. Pilot arc IS 315 and 355. Pilot arc IS present.) present.) present.) present.) 1) Open connection between the console WORK connector and the workpiece. 1) a) Check continuity of WORK cable and clamp b) Attach clamp to workpiece c) Ground work table to earth ground Arc do Arc do Arc do Arc does not transfer to work. es not transfer to work. es not transfer to work. es not transfer to work. (Open Circuit Voltage is between (Open Circuit Voltage is between (Open Circuit Voltage is between (Open Circuit Voltage is between 315 and 355. Pilot arc is NOT 315 and 355. Pilot arc is NOT 315 and 355. Pilot arc is NOT 315 and 355. Pilot arc is NOT present.) present.) present.) present.) 1) Pilot arc fuses F1 and/or F2 are open. 2) Bad pilot arc contactor. 3) Bad K3. 4) Bad PCB1 in MOD2. 5) Nozzle to Electrode short in torch. 6) Bad control PCB 7) No preflow signal from CNC. 8) Current setting to low 9) Contaminated or worn electrode. 1) Replace F1 and/or F2. 2) Replace pilot arc contactor. 3) Replace K3 4) Replace PCB1 in MOD2. 5) Disconnect torch from console. Check for open between pilot arc and torch leads. Repair if shorted. 6) Replace control PCB. 7) Bad PCB1. Bad MOD1 PCB1. 8) Readjust Current setting. Torch to high above workpiece. 9) Replace electrode. SECTION 6 TROUBLESHOOTING NOTE: Additional Schematics and Wiring Diagrams on NNYNN wYw QBQFS BSFJODMVEFEJOTJEFUIFCBDLDPWFSPGUIJTNBOVBM

Always provide the serial number of the unit on which the parts will

be used. The serial number is stamped on the unit nameplate. 5PFOTVSFQSPQFSPQFSBUJPO JUJTSFDPNNFOEFEUIBUPOMZHFOVJOF&4"# parts and products be used with this equipment. The use of non-ESAB parts may void your warranty. Replacement parts may be ordered from your ESAB Distributor. Be sure to indicate any special shipping instructions when ordering replacement parts. 3FGFSUPUIF$PNNVOJDBUJPOT(VJEFMPDBUFEPOUIFCBDLQBHFPGUIJT manual for a list of customer service phone numbers. #JMMPGNBUFSJBMJUFNTUIBUIBWFCMBOLQBSUOVNCFSTBSFQSPWJEFEGPS customer information only. Hardware items should be available through local sources. Note:

Revision History 3FMFBTFE+BOVBSZ   3FWJTJPO6QEBUFE*OQVU$POEVDUPSBOEMJOF'VTFDIBSUQFS+.BHFF 2.

'PS BEESFTTFT BOE QIPOF OVN

CFST UP PVS EJTUSJCVUPST JO PUIFS DPVOUSJFT  QMFBTF WJTJU PVS IPNF QBHF XXXFTBCDPN &4"#"# 4&-"9¯ 48&%&/ 1IPOF  XXXFTBCDPN YYYY &4"#TVCTJEJBSJFTBOESFQSFTFOUBUJWFPöDFT

Other Cutter Manuals