Item No. 2250408 Page 2 - 49 Notice d’emploi Serrure à code étanche IP65 N° de commande 2250408 Page 50 - 102 Gebruiksaanwijzing Waterdicht codeslot IP65 Bestelnr. 2250408 Pagina 103 - 154 Istruzioni Blocco codice impermeabile IP65 N°.: 2250408 Pagina 155 - 205 Instrukcja użytkowania Wodoodporny zamek szyfrowy IP65 Nr zamówienia: 2250408 Strona 206 - 259 ...
Page 1. Introduction............................................................................5 2. Explanation of symbols.........................................................6 3. Intended use..........................................................................6 4. Package contents..................................................................7 5. Features and functions.................................................... ...
11. Operation.............................................................................22 a) Inserting the batteries (keypad).....................................22 b) Low battery indicator......................................................22 c) Replacing the batteries (keyp ...
o) Programming the door open warning.............................43 p) Programming the forced opening alarm.........................44 q) Programming reset cards...............................................44 r) Restoring factory settings..............................................46 14. Care and cleaning...............................................................46 ...
This product complies with statutory, national and European reg- ulations. To ensure that the product remains in this state and to guarantee safe operation, always follow the instructions in this manual. These operating instructions are part of this product. They contain important information on setting up and using the product. Do not give this product to a third party without the ope ...
The symbol with the lightning in a triangle indicates that there is a risk to your health, e.g. due to an electric shock. The symbol with an exclamation mark in a triangle is used to highlight important information in these operat- ing instructions. Always read this information carefully. The arrow symbol indicates special information and tips on how to use the product. 3. Intended use This product is designed to secure door ...
ponents can only be used in enclosed areas. They are not suit- able for outdoor use. Contact with moisture (e.g. in a bathroom) must be avoided under all circumstances. For safety and approval purposes, do not rebuild and/or modify this product. Using the product for purposes other than those de- scribed above may damage the product. In addition, improper use can cause hazards such as a short ci ...
• User manual 1Up-to-date operating instructions Download the latest operating instructions at www.conrad.com/downloads or scan the QR code shown. Follow the instructions on the website. 5. Features and functions • Code lock with wireless keypad (up to 30 m range) • Up to 600 user codes or EM cards (500 normal users and 100 visitors) • Keypad with IP65 protection rating (outdoor installation and operation) 8 ...
mation carefully. If you do not follow the safety information and information on proper handling in these operating instructions, we will assume no liability for any resulting personal injury or damage to property. Such cases will invalidate the warranty/guarantee. a) General information • The device is not a toy. Keep it out of the reach of children and pets. • Do not leave packaging m ...
safely, stop using it and prevent unauthorised use. Safe operation can no longer be guaranteed if the product: -- is visibly damaged, -- is no longer working properly, -- has been stored for extended periods in poor ambient conditions or -- has been subjected to any serious transport- related stress. • Handle the product carefully. Jolts, impacts or a fall even from a low height may damage the prod ...
• The relay switch contact has a maximum contact rating of 12 V/DC, 2 A. It must never be used with a higher voltage, other type of voltage (e.g. mains voltage) or high currents. This may cause a fatal electric shock! • This moisture-sensitive components of the prod- uct must only be installed and used in dry indoor rooms. • Do not use the product in environments where there are high levels of dust, flammable gases, vapours ...
Mixing old and new batteries can cause the batter- ies to leak and damage the product. • Batteries must not be dismantled, short-circuited or thrown into open flames. Never recharge non-re- chargeable batteries. This may cause an explosion! 7. Controls 1 2 3 7 6 4 5 1 Symbol 2 Ring button 3 Keypad 4 Green LED 5 Red LED 6 Relay 7 Opening button with EXIT button and LED indicator 12 ...
a) Installation When installing the individual components, pay attention to the range of the wireless signal. The distance between the components must not exceed the wireless range. 1Installation with double-sided adhesive tape • The keypad and the wireless opening button can be attached to smooth, clean surfaces with double-sided adhesive tape. Remove the protective film and stick the adhesive tape to the back of the co ...
secure the base plate. On surfaces such as wood or plastic, it is sufficient to use only the screws. Dowels are primarily designed for mineral-based wall materials. • Proceed as described above to screw the opening button in place. • The relay can only be secured with screws. • Use the relay as a template and mark the necessary holes. Proceed in the same way as described above to scre ...
The code lock can be used with fail-safe or fail-secure door open- ers. The door opener must be connected differently depending on its design. Make sure that the door opener is connected correctly. Refer to section "b) Wiring diagram with connections" for more information on connection options. "Fail-secure" door openers: Fail-secure door openers release the latch when the power supply delivers a voltage (standard door opener type). " ...
squashed. This can cause malfunctions, short circuits and device defects. Only connect devices when the product is disconnected from the power supply. • Always place the cables bare/stripped into the screw connections and tighten them sufficiently with a screwdriver. Take care not to over-tighten them. • Use the supplied screwdriver to connect the electrical connections. a) Assignmen ...
NC Connection for relay (fail-safe configuration) OPEN Connection for the opening button D_IN Connection for detecting the opening/closing status of the lock BELL_A Connection for bell A BELL_B Connection for bell B • Connect the cables to the corresponding screw terminals. Two circuit examples can be found in "b) Circuit diagram with connections". Never connect a mains voltage here! This may cause a fatal elec ...
1Relay power supply via NO contact DC power supply Fail-secure lock Magnet or fail- safe lock 2NO contact power supply via relay Fail-secure lock Magnet or fail- safe lock DC power supply 18 ...
to electrostatic discharge (ESD), always connect the protective earth. • Depending on the door closer to be connected, select the correct connection option – fail-safe or fail-secure. • The supplied diode should be connected as close as possible to the N.O. contacts to prevent the code lock from being damaged due to a current generated by an inductive coupling in the N.O contact coil. 10. Opera ...