Datalogic QuickScan QS2500 Product Reference Manual
Text of the manual
Datalogic Scanning, Inc.
959 Terry Street
Eugene, Oregon 97402
Telephone: (541) 683-5700
Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures
described therein may be reproduced or transmitted in any form or by any means without prior written permission of
Datalogic Scanning, Inc. or
Product Reference Guide
1
Table of Contents
Installation ......................................................................................... 1
Keyboard Wedge .........................................................................................1
Wand Emulation ...............................................................
Standard 2 of 5 .........................................................................................54
Code 16K .................................................................................................56
PDF417 ....................................................................................................57
Italian PharmaCode .....
Product Reference Guide
1
Installation
Complete the following steps for the appropriate interface.
Keyboard Wedge
1.
Turn off the terminal or computer.
2.
Disconnect the keyboard cable from the back of the terminal or
computer.
3.
Connect the QS2500 to the terminal or computer using the appro-
priate interface cable.
4.
Turn the te
Plug the USB cable into the terminal or computer.
IBM
1.
Turn off the terminal or computer.
2.
Connect the appropriate interface cable to the terminal or com-
puter.
3.
Turn the terminal or computer on.
NOTE
If the QS2500 does not operate, turn off the terminal or computer
immediately and check all connections. If necessary, go through the
ab
Product Reference Guide
3
Programming the QS2500
To program the QS2500, you must scan a series of programming bar
codes in the correct order. The inside back cover of this manual contains a
table of alphanumeric bar codes needed to program the various options.
To program each option:
1.
Scan the Start Program bar code above the lis
Resetting the QS2500
To return all QS2500 option settings to the factory defaults, scan the fol-
lowing two bar codes, in the order shown:
Interfaces
The QS2500 supports Keyboard Wedge, RS-232, Wand Emulation, IBM
and USB interfaces. The correct interface cable is included for the scanner
interface type you ordered.
Keyboard Wedge
As a keyboard inte
Product Reference Guide
5
Function Key: When this option is enabled, the QS2500 outputs bar code
ASCII values from 01hex to 1Fhex as function-key presses in your applica-
tion. See the table of ASCII codes In Appendix C on page 66.
Option Bar Code
Option
Alphanumeric
Entry
Keyboard Type
IBM AT, PS/2
00*
Reserved
01 - 06
Keyboard La