USER MANUAL BIO-RID

SMART-I ELECTRONICS SYSTEMS PVT. LTD.(An ISO 9001:2008 certified company) Corporate Office: Unit No 250,251,252, Second Floor, Building No D-7, Bhumi World, PimplasVillage, Mumbai- Nashik Highway,BHiwandi, Thane-421302 Tel: + 91-22-6566 6555 Web site: www.smartisystems.com PRESENCE : MUMBAI - DELHI - BANGALORE – KOLKATA - CHENNAI - AHMEDABAD – PUNE - HYDERABAD Bio-RID(Reader)

1. PRODUCT SELECTION ......................................................................................................................... 3

2. INTRODUCTION .................................................................................................................................... 3 3. TECHNICAL SPECIFICATION .............................................................................................................. 4 4. DESCRIPTION OF KEYS & OTHER PARTS......................................................................................... 5 5. OPERATION .......................................................................................................................................... 6 6. CONNECTION DETAILS ......................................................................................................................10 7. DEVICE CONFIGURATION ................................................................................................................. 12 8. RECOMMENDED CABLE SPECIFICATION ....................................................................................... 12 9. MOUNTING OF UNIT ON THE WALL .............................................................................................. 13 10. CONNECTING TO HOST COMPUTER................................................................................................16 11. ENROLLMENT PROCESS,.....................................................................................................................19 12. TROUBLESHOOTING GUIDE .........................................................................................................................20

1. PRODUCT SELECTION

Particulars Specifications Model no. SBSK1950 Applications Weigand Reader 2. INTRODUCTION Smart-i introducing BIO-RID as weigand reader. This is fingerprint device easy to installation & user friendly operations. Bio-RID the Biometric + Card Reader from smart-i, is very fast and efficient in all processing and communication functions, faster than any other Biometric + Card reader in its category, making it an ideal option for any organization with a fairly large or very large number of employees.

3. TECHNICAL SPECIFICATION

Hardware specification: Particulars Description CPU 32 Bit RISC Arm Memory Upto Flash 8 MB Events/Transactions 1,00,000 No. of templates in sensor 1900/19000 Operation Modes UID/Card + Finger, UID/Card only ,Card + Finger Card Only Card & finger Sensor High Quality Scratch Resistance Optical Sensor. Communications Port TCP/IP, weigand, RS485 Baud Rate 9600bps (Default) Controller ID Max 9999 LED Tricolor LED Bar Language English Power Supply 12 V DC/ 2A (Min) Enclosure IP65 ABS Plastic Color Silver & Black Dimension (H X W X D) in mm (209 x 57 x 47.02)in mm Mounting Wall Mounting Sensor specification: Particulars Description Type Optical Image Resolution 500 dpi Enrollment Time <1 sec Verification Time <1sec Identification Time 1 sec Template Size 384 bytes EER/FAR/FRR <0.1%/0.001%/0.1% Image Size (Pixels) 272 X 320 Sensing Area (mm) 16 X 19 Special Features: Particulars Description LED indications POWER ON Valid card/ Finger ADD card DEL card ADMIN Login Buzzer for different Indication Valid/Invalid →Card/Finger Finger Addition Error Indication

4. DESCRIPTION OF KEYS & OTHER PARTS

① Multicolor LED indication ② Card reader ③ Biometric sensor 2 3 1 LED indications with beeps: Sr. No. Functions LED colors Beeps 1 Finger added Green Two beeps 2 Finger timeout Red Single beep 3 Putting Same finger for enroll Red Single beep 4 Enroll fingers more then 1 Red Two beeps 5 Device Power ON Red Single beep 6 Valid user Green Long beep 7 Invalid user Red Two beeps 8 Invalid finger Red Two beeps Note:  If the card is not shown within five beep completion then bio-RID will stop to blinking . & we need to show card again.  Per user you can add only 2 finger. If no finger/ card is added in Device , then RED LED will blink continously with a beep . 

Using Mobile APK.

1. Open SmartADMIN APK on Android phone 2. Select Bluetooth connection mode from the following options 3. Allow SmartAdmin Apk to turn on the Bluetooth 5. Operation

5. Enter USERNAME : 11111 and PASSWORD: 12345 & Press Login.

4. Scan for the bluetooth Device and select the Device 6. Device display message Bluetooth connected and the window shown below is opened on apk.

7. To add New user, click on User >> Add User .

Now Add user .: Enter UID/Card number or click on scan option and Show card across reader. 10. To Delete added User enter the added UID number and click on Delete. 11. Press : Logout to logout from the device. 8.Click on Advance and Select card type → UID/Card+Finger and Press Enroll. 9. Blue LED will start blinking ,Place Finger on prism of sensor twice , after finger is enrolled sucussfully message is displayed on apk and LED will turn Green.

Set IP address to device for TCP/IP communication

2. Subnet Mask As per your network. 3. Gateway As per your network. 4. Local TCP Port For device indentification and communication 5. Local UDP Port For device indentification and communication. 6. Server IP Set Server IP Address, it is used when MAC security feature is Enable. 7. PUSH Server1 IP Set Server IP Address where we want to push transaction data using TCP. 8. PUSH Server1 Port Set Server Port Address where we want to push transactiondata using TCP. 9. PUSH Server2 IP NA 10. PUSH Server2 Port NA 11. UDP PushServer IP Set Server IP Address where we want to push transaction data using UDP. 12. UDP PushServer Port Set Server Port Address where we want to push transactiondata using UDP. 13. HB Server IP Set Server IP Address where we want to push Heart Beat data. Device sendsall important information to this server. 14. HB Server Port Set Server Port Address where we want to push Heart Beat data. 15. HB Time Set Heart Beat Time,this is time delay after which controller send Device Information to HB Server IP.

CAT5e / CAT6 FOR

LAN COMMUNICATION Network Switch (C) (A) TX+ BZ V+ TAMP V- RX- RX+ LED TX- D1 D0 D- GND D+ 12V (B) (D) GND 12V ETHERNET RS 485 POWER READER WGND OUT WGND IN Access Control Device 12V GND D0 D1 BZ LED TAMP For Template management 6. Connection Details

Bio-RID Connector WIRE details

A B C D Weigand Reader Ethernet RS485 Power PIN PIN DESCRIPTION WIRE 1 POWER + (12Vdc) RED 2 POWER - BLACK PIN PIN DESCRIPTION WIRE 1 D+ GREEN 2 D- WHITE PIN PIN DESCRIPTION WIRE 1 TX+ BLUE 2 TX- ORANGE 3 RX+ GREY 4 V+ BROWN 5 R- YELLOW 6 V- BROWN PIN PIN DESCRIPTION WIRE 1 12V RED 2 GND BLACK 3 D0 GREEN 4 D1 WHITE 5 BUZZER YELLOW 6 LED BROWN 7 VOILET

7. DEVICE CONFIGURATION

Bio-RID as Reader: 8. RECOMMENDED CABLE SPECIFICATION Type Particular Cable Spec Distance A Reader (Weigand) 22AWG; 6 core; shielded Cable Up to 25 meter B Egress switch, Magnetic contact 22 AWG;2 core; shielded Cable Up to 10Ft. C Lock 16 AWG; 2 core; shielded Cable Up to 10 Ft. D Unit to Power Supply 22AWG; 2 Core shielded Cable Up to 10 Ft. E LAN Cable 24AWG; CAT5 / CAT6 (4 pair) Up to 100 meter Internet ADSL Switch Router Lock Lock To reader section To reader section TCP connection

STANDALONE Bio-RID CONFIGURATION

FIRE INTEGRETION PANEL SMARTi Software TCP/IP HUB EML Lock TCP/IP OUT

Weigand OUT connection:

RS485 connection: D+ D- To controller for template management by TCP/IP comm. J8 NC LED D1 D0 GN 12V Brown White Green Black Red J12 In weigand out mode need to use this connection to connect with controller at it’s reader section. LED D1 D0 GN 12V To reader section

Pan head self

threaded star (M3*10) screw in wall Pan head self threaded star (M3*10) screw in wall Pan head self threaded star (M3*10) screw in wall 9. Mounting on Unit on Wall

Notch to Fit the

Device Notch to Fit the Device Note. Place the Plate on Wall and Fit the Device with a Screw.

Testing the Connection To test the connection following is the under mentioned steps

Step 1 At the PC, Click Start -> Run -> Type “command” and press ‘OK’. Step 2 Type “telnet ipaddress port" (The IP Address should reflect that of your Bio-RID unit) Note: - If unsuccessful, either “Connect failed will be displayed, please follow the above steps carefully and test the connection. Successful Connectivity Unsuccessful connectivity

There are a few points that can be checked to fix it:

 Make sure the network cable is functional; sometimes a damaged cable may be the cause of all problems. To check if it is functional, make sure there are no loose ends and the jack is properly attached to the cable.  Check that the IP Address Assignment matches the network settings of the corporate LAN or the PC being used.  Make sure no IP has clashed and that there are no two identical IP addresses in the network. # Is it possible to connect two locks or two readers on single connector?  NO, do not connect 2 locks or 2 readers together on a single connector. A single lock connector can safely drive 600mA current.  If load current increases beyond 1A, that may cause hardware problems. # "Time out" is displayed after the sensor went on the state of "Light-up".  The state of your fingerprint is dry. So, the sensor may not scan the image of your fingerprint in time.  You have to check if the strength of pushing when your finger pressed on the sensor is strong or not.  You have to keep being proper strength when your finger pressed on the sensor.  You have to check if your finger departs from the sensor before capturing the image.  Your fingerprint doesn't have to depart from the sensor before capturing image. # When finger is placed on sensor in display show “User Unauthorized”  To Enter into Admin Mode & search user finger refer keypad functions.  If user is added then it will show card no and fingers enrolled.  The state of your fingerprint is dry. So, the sensor cannot scan the image of your fingerprint in time.  You have to place your finger squarely and firmly on the sensor for proper scanning of the fingerprint image. # Continues Beep & Door Force Open  Checkfor lock magnetic contact (MC+/ MC-), it should be short if not in used.(Refer connection Diagram) # Admin User: User/Password Fail  If the System/Unit is initializing then password will not match. In this case RESET the System i.e. power off and then power on the system then enter Admin Id and password. # Is it possible to connect Bio-rid as weigand reader then what will be to step follow-up?  No Not possible to connect Bio-RID as weigand reader on Site 12. TroubleShooting Guide