SICK GRL18V Operating Instructions Manual
Text of SICK GRL18V Operating Instructions Manual
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is
only permissible within the limits of the legal determination of Copyright Law. Any modi‐
fication, abridgment or translation of this docum
General safety notes.........................................................................
5
2
Notes on UL approval........................................................................
5
3
Intended use......................................................................................
5
4
Operating and status indicators......................................................
5
5
Mounting.....................................................
General safety notes
■
Read the operating instructions before commissioning.
■
Connection, mounting, and configuration may only be performed by trained
specialists.
■
2006/42/EC
NO
SAFETY Not a safety component in accordance with the EU Machinery Directive.
■
Do not install the sensor at locations that are exposed to direct sunlight
or other weather influences, unless this is expressly permitted in the operating
instructions.
■
These operating
Figure 1: Operating element: sensitivity setting
5
Mounting
Mount the sensor and the reflector using suitable mounting brackets (see the SICK
range of accessories). Align the sensor and reflector with each other.
max. 90 Nm
Note the sensor’s maximum permissible tightening torque of 90 Nm.
6
Electrical installation
The sensors must be connected in a voltage-free state (UV = 0 V). The following informa‐
tion must be observed, depending on the conne
UB: 10... 30 V DC, see „Technical specifications“, page 11
Table 1: DC
GRL18(S)V
x11xxx
x13xxx
x24xxx
x23xxx
1
+ (L+)
+ (L+)
+ (L+)
+ (L+)
2
Q
n. c.
Q
n. c.
3
- (M)
- (M)
- (M)
- (M)
4
Q
Q
Q
Q
1 = BN
2 = WH
3 = BU
4 = BK
0.14 mm2
AWG26
1 = BN
-
3 = BU
4 = BK
0.14 mm2
AWG26
1
2
4
3
1
2
4
3
Table 2: DC
PNP: Q (≤ 100 mA)
+ (L+)
Q
– (M)
+ (L+)
Q
– (M)
NPN: Q (≤ 100 mA)
+ (L+)
Q
– (M)
+ (L+)
Q
– (M)
PNP: Q (≤ 100 mA)
+ (L+)
Q
– (M)
+ (L+)
Q
Align the sensor with a suitable reflector. Select the position so that the red emitted
light beam hits the center of the reflector. The sensor must have a clear view of the
reflector, with no object in the path of the beam [see figure 2]. You must ensure that the
optical openings of the sensor and reflector are completely clear.
Figure 2: Alignment
7.2
Check the application conditions
Adjust the distance between the sensor an
Figure 4: Sensing range
Table 3: Definition of sensing range
2
GRL18(S)V
1
PL80A
0.03 ... 7.2 m
2
PL40A
0.03 ... 6.2 m
3
PL20A
0.03 ... 3.8 m
4
P250
0.03 ... 6.4 m
5
PL22
0.03 ... 2.2 m
6
REF-Plus 3436
0.06 ... 2.0 m
7.3
Setting
Sensitivity setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
The sensitivity is adjusted with the potentiometer (type: 270°). Clockwise rotation:
operating reserve increased; coun