5 2 Notes on UL approval........................................................................ 5 3 Intended use...................................................................................... 5 4 Operating and status indicators...................................................... 5 5 Mounting.....................................................

General safety notes

■ Read the operating instructions before commissioning. ■ Connection, mounting, and configuration may only be performed by trained specialists. ■ 2006/42/EC NO SAFETY Not a safety component in accordance with the EU Machinery Directive. ■ Do not install the sensor at locations that are exposed to direct sunlight or other weather influences, unless this is expressly permitted in the operating instructions. ■ These operating

Figure 1: Operating element: sensitivity setting

5 Mounting Mount the sensor and the reflector using suitable mounting brackets (see the SICK range of accessories). Align the sensor and reflector with each other. max. 90 Nm Note the sensor’s maximum permissible tightening torque of 90 Nm. 6 Electrical installation The sensors must be connected in a voltage-free state (UV = 0 V). The following informa‐ tion must be observed, depending on the conne

UB: 10... 30 V DC, see „Technical specifications“, page 11

Table 1: DC GRL18(S)V x11xxx x13xxx x24xxx x23xxx 1 + (L+) + (L+) + (L+) + (L+) 2 Q n. c. Q n. c. 3 - (M) - (M) - (M) - (M) 4 Q Q Q Q 1 = BN 2 = WH 3 = BU 4 = BK 0.14 mm2 AWG26 1 = BN - 3 = BU 4 = BK 0.14 mm2 AWG26 1 2 4 3 1 2 4 3 Table 2: DC PNP: Q (≤ 100 mA) + (L+) Q – (M) + (L+) Q – (M) NPN: Q (≤ 100 mA) + (L+) Q – (M) + (L+) Q – (M) PNP: Q (≤ 100 mA) + (L+) Q – (M) + (L+) Q

Align the sensor with a suitable reflector. Select the position so that the red emitted

light beam hits the center of the reflector. The sensor must have a clear view of the reflector, with no object in the path of the beam [see figure 2]. You must ensure that the optical openings of the sensor and reflector are completely clear. Figure 2: Alignment 7.2 Check the application conditions Adjust the distance between the sensor an

Figure 4: Sensing range

Table 3: Definition of sensing range 2 GRL18(S)V 1 PL80A 0.03 ... 7.2 m 2 PL40A 0.03 ... 6.2 m 3 PL20A 0.03 ... 3.8 m 4 P250 0.03 ... 6.4 m 5 PL22 0.03 ... 2.2 m 6 REF-Plus 3436 0.06 ... 2.0 m 7.3 Setting Sensitivity setting Sensor which it is not possible to set: The sensor is adjusted and ready for operation. The sensitivity is adjusted with the potentiometer (type: 270°). Clockwise rotation: operating reserve increased; coun