PURELL® ONVATION CXR Objectives You will learn how to perform the following • Recording required MAC ID of PURELL PAN Module • Installing PAN Module into CXR Dispenser • Provisioning the PAN Module to the ONVATION Hub • Validating PAN Module connectivity • Troubleshooting setup issues Equipment • ...
Page 2 of 7 Step Illustration Connector on the dispenser. 6. Verify that the pins have connected correctly and that the connector is fully seated. The flat side of the module connector end should align with the flat edge of the CXR Connector end. If it is fully seated, the blue light will be blinking on the m ...
Page 3 of 7 Step Illustration 11. Remove the dust cap from the soap refill, then insert the spout opening until the refill clicks into place. An Orange light will indicate the soap is flowing into the dispenser. If the orange light doesn’t illuminate, adjust the position of the refill until it comes on. 12. ...
Page 4 of 7 module will enter pairing mode. Once paired, the module will connect to Onvation. 2. Alternately a factory reset may be performed: If the magnet is held for a long period of time, all LEDs will turn on. This means a factory reset of the module is performed. All parameters are erased. The modul ...
Page 5 of 7 State: Advertising OR In advertising mode, either the Green and Red LED or only the Red LED blinks at a rate of 2X per second. If the green LED is blinking, this means that the module is in pairing mode and that it will accept a new bond. This state transitions to a new state when advertising m ...
Page 6 of 7 All Other States In all other states, the LEDs are OFF to conserve power. User Interface Pairing Mode If the magnetic switch is engaged for 500ms (1/2 second), the device will enter pairing mode. In this case, the LEDs will confirm the selection by blinking the Blue LED and turning the Green LED ...
Defaults The default settings for the module board are as follows: Synchronization Interval: 60 minutes (may be set to any value [30 Dispense Count Threshold: 50 dispenses (may be set to any value [5 Device Compliance Onvation Module FCC/IC Label Please include on dispenser packaging or enclosure the followin ...