TDE Instruments Digalox DPM72-MP Instruction Manual
Read Online
Read the TDE Instruments Digalox DPM72-MP Instruction Manual online using the built-in PDF viewer.
Key Pages of Document
Visit www.digalox.com to download the software “Digalox® Manager”. Package contents: Panel meter Digalox® DPM72-MP, mounting bracket, 5 jumpers, 2 instruction manuals (EN + DE) 1. Intended Use Indoor use non condensing, non corrosive. Panel mounting. Failure to comply with these instructions will void all guarantee and warranty. In operation, supply the device preferably via screw te ...
simultaneously. Thresholds can be associated with individual warning backlight colours. The unit can be switched between display values via an external switch. Minimum and maximum values of up to four parameters are recorded and can be displayed optionally using an external switch. Measured values are recorded over a time span of 36 seconds up to 14 da ...
Supply Digalox − + 12 - 24 V Fuse 250 mA Supply Voltage direct max. 500 V Ilow Ihigh Uhigh Ulow +/L -/N Current direct Ilow Ihigh Load +/L -/N max. 10 A Uhigh Ulow FF 10 A Current and voltage direct Ilow Ihigh Load +/L -/N max. 10 A max. 500 V Uhigh Ulow FF 10 A Current via current transformer Load Current transformer Ilow Ihigh Uhigh Ulow max. 10 A FF +/L -/N Current via current transformer, voltage direct Load Current trans ...
corresponding software “Digalox® Manager” via USB interface. When configuring via DIP switches and jumpers the basic settings can be made computer-independent. The configuration with the software “Digalox® Manager” allows full functionality. Configuration via USB interface with software “Digalox® Manager” For configuration with software set DIP sw ...
to switch between multiple display values via an external switch (Save mode) The required display values are configured and saved sequentially. 1. Set DIP-switch 10, 11 and 12 to OFF position. 2. Connect supply voltage. 3. Set the display value with jumpers at J4-J6 according to table "display value”, column “Save mode". 4. Set DIP switch 10 to ON position. 5. Set upper sc ...
Value Combination Value Combination Value Combination 10 ON 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 50 ON 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 200 ON 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 20 ON 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 100 ON 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 250 ON 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 25 ON 1 2 3 ...
The following functions can be activated independently by short-circuiting connectors J1-J3 by jumper or switch during operation: J1: Graphical historic data display The unit displays the stored values within the set time base as a graphical trend. The time base can be set to days (7, 14), hours (1, 3, 6, 12, 24, 48, 72), minutes (3, 15, 30) or seconds (36). The time base can be changed by alternately opening and closing ...
the back and push towards the panel until the device sits tight. Make sure the mounting bracket is snapped into the side of the housing. To ensure IP65 protection (dust and water jet) when mounting in a front panel, use optional gasket (separately available). 8. Specifications DPM72-MP Supply 12 - 24 V AC/DC ±10% (50/60 Hz ±10%) or via USB, galvan ...