Crown Macro-Tech MA-5002VZ Service Manual

Text of Crown Macro-Tech MA-5002VZ Service Manual

© 2000 by Crown International, Inc., P.O. Box 1000, Elkhart, Indiana 46515-1000 U.S.A.

Telephone: 219-294-8000. Trademark Notice: Grounded Bridge™, PIP2™ and SmartAmp™ are trademarks and Amcron®, Crown®, IOC®, IQ System®, Macro-Tech,® ODEP® and VZ® are registered trademarks of Crown International, Inc. Other trademarks are the property of their respective owners. Models: MA-5

MA-5002VZ Service Manual

II 130446-1 Rev. A ©2000 Crown International, Inc. À PRÉVENIR LE CHOC ÉLECTRIQUE N’ENLEVEZ PAS LES COUVERTURES. RIEN DES PARTIES UTILES À L’INTÉRIEUR. DÉBRANCHER LA BORNE AVANT D’OUVRIR LA MODULE EN ARRIÈRE. TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. DISCONNECT POWER CORD BEFORE REMOVING REAR INPUT MODULE TO ACCESS

Crown Macro-Tech MA-5002VZ 130446-1 Rev. A

MA-5002VZ Service Manual ©2000 Crown International, Inc. Revision History Revision Number Date Comments Rev. A 02-2000 Initial Printing
MA-5002VZ Service Manual IV 130446-1 Rev. A ©2000 Crown International, Inc. This page intentionally left blank
130446-1 Rev. A MA-5002VZ Service Manual ©2000 Crown International, Inc. Table of Contents 1 Introduction ............................................................................ 1-1 1.1 Introduction ................................................................................ 1-1 1.2 The MA “02” Series Amplifiers ................................................... 1-1 1.3 Scope ................................................................
MA-5002VZ Service Manual VI 130446-1 Rev. A ©2000 Crown International, Inc. 5 Maintenance........................................................................... 5-1 5.1 Cautions and Warnings.............................................................. 5-1 5.2 General Information ................................................................... 5-1 5.3 Troubleshooting ........................................................................ 5-1 5.3
130446-1 Rev. A MA-5002VZ Service Manual ©2000 Crown International, Inc. 1.1 Introduction This manual contains complete service information on the Crown® MA-5002VZ power amplifier. It is designed to be used in conjunction with the Reference Manual; however, some important information is duplicated in this Service Manual in case the Reference Manual is not readily available. NOTE: THE INFORMATION IN THIS MANUAL IS INTENDED FOR USE BY AN E
MA-5002VZ Service Manual 1-2 Introduction 130446-1 Rev. A ©2000 Crown International, Inc. Figure 1.1 MA-5002VZ Front and Rear Views
130446-1 Rev. A MA-5002VZ Service Manual ©2000 Crown International, Inc. Specifications The following applies to 120-VAC, 60-Hz units in Stereo mode with 8-ohm loads and an input sensitivity of 26-dB gain unless otherwise specified. Specifications for units supplied outside the U.S.A. may vary slightly at different AC voltages and frequencies. Power Output Power Load Impedance: Safe with all types of loads. Rated for 2 to 8 ohms in Ster
MA-5002VZ Service Manual 2-2 Specifications 130446-1 Rev. A ©2000 Crown International, Inc. Figure 2.1 Dimensions DC Output Offset: ±10 millivolts. Output Signal Stereo: Unbalanced, two-channel. Bridge-Mono: Balanced, single-channel. Channel 1 controls are active; Channel 2 controls are removed from operation. Parallel-Mono: Unbalanced, single-channel. Channel 1 controls are active; Channel 2 controls are by passed. Protection Macro-Tech amplifiers are p
130446-1 Rev. A MA-5002VZ Service Manual ©2000 Crown International, Inc. Figure 2.3 Typical Frequency Response Figure 2.4 Typical Damping Factor Figure 2.5 Typical Output Impedance
MA-5002VZ Service Manual 2-4 Specifications 130446-1 Rev. A ©2000 Crown International, Inc. This page intentionally left blank

Crown Macro-Tech MA-5002VZ Voltage Conversion 3-1

130446-1 Rev. A MA-5002VZ Service Manual ©2000 Crown International, Inc. 3 Voltage Conversion INSTRUCTIONS CAUTION: Because there is a risk of electric shock, only a qualified technician should change the line voltage configuration. 1. Turn the amplifier off and disconnect it from the AC power source. (The enable switch alone does not re- move lethal voltage from the line cord.) Wait at least 10 seconds before proceeding. 2. Drain
MA-5002VZ Service Manual 3-2 Voltage Conversion 130446-1 Rev. A ©2000 Crown International, Inc. CAUTION: To reduce the risk of fire, replace F700, F701, & F702 with the same type fuse. Use a 30 A fuse for F700 & F701 and a 1A fuse for F701 for ALL voltage configurations. ATTENTION: Utiliser un fusible de même type (F700, F701 = 30A. F702 = 1A.) pour toutes applications. Figure 3.2 Voltage/Frequency Conversion Physical Layout

Circuit Theory 4-1

130446-1 Rev. A MA-5002VZ Service Manual ©2000 Crown International, Inc. 4 Circuit Theory 4.1 Overview It should be noted that over time Crown makes improve- ments and changes to their products for various rea- sons. This manual is up to date as of the time of writing. For additional information regarding these amplifiers, refer to the applicable Technical Notes provided by Crown for this product. Sketches have been added to this secti
MA-5002VZ Service Manual 4-2 Circuit Theory 130446-1 Rev. A ©2000 Crown International, Inc. Figure 4.1 Simplified Grounded Bridge by the output stages rather than the power supply. Composite devices are constructed to function as gi- gantic NPN and PNP devices since the available cur- rents exceed the limits of existing individual devices. The devices connected to the load are referred to as “high-side NPN and PNP” and the devices connected to ground

Circuit Theory 4-3

130446-1 Rev. A MA-5002VZ Service Manual ©2000 Crown International, Inc. full (negative) potential developed by the power sup- ply. The total effect is to deliver a peak to peak voltage to the speaker load which is twice the (static) voltage pro- duced by the power supply. Benefits include full utiliza- tion of the power supply (it conducts current during both halves of the output signal; conventional designs re- quire two power supplie
MA-5002VZ Service Manual 4-4 Circuit Theory 130446-1 Rev. A ©2000 Crown International, Inc. 4.3 VZ Power Supply VZ means Variable Impedance and is the name of Crown’s patented articulated power supply technology. It enables Crown to pack tremendous power into just 5.25 inches of vertical rack space. A power supply must be large enough to handle the maximum voltage and current necessary for the ampli- fier to drive its maximum rated power into a specifie

Crown Amplifier Owners Instructions: