Crown Macro-Tech MA-5002VZ Service Manual
Text of Crown Macro-Tech MA-5002VZ Service Manual
© 2000 by Crown International, Inc., P.O. Box 1000, Elkhart, Indiana 46515-1000 U.S.A.
Telephone: 219-294-8000. Trademark Notice: Grounded Bridge™, PIP2™ and SmartAmp™ are
trademarks and Amcron®, Crown®, IOC®, IQ System®, Macro-Tech,® ODEP® and VZ® are
registered trademarks of Crown International, Inc. Other trademarks are the property of their
respective owners.
Models:
MA-5
MA-5002VZ Service Manual
II
130446-1 Rev. A
©2000 Crown International, Inc.
À PRÉVENIR LE CHOC
ÉLECTRIQUE N’ENLEVEZ
PAS LES COUVERTURES.
RIEN DES PARTIES
UTILES À L’INTÉRIEUR.
DÉBRANCHER LA BORNE
AVANT D’OUVRIR LA
MODULE EN ARRIÈRE.
TO PREVENT ELECTRIC SHOCK DO
NOT REMOVE TOP OR BOTTOM
COVERS. NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE
PERSONNEL. DISCONNECT
POWER CORD BEFORE REMOVING
REAR INPUT MODULE TO ACCESS
Crown Macro-Tech MA-5002VZ 130446-1 Rev. A
MA-5002VZ Service Manual
©2000 Crown International, Inc.
Revision History
Revision Number
Date
Comments
Rev. A
02-2000
Initial Printing
MA-5002VZ Service Manual IV
130446-1 Rev. A
©2000 Crown International, Inc.
This page intentionally left blank
130446-1 Rev. A MA-5002VZ Service Manual
©2000 Crown International, Inc.
Table of Contents
1 Introduction ............................................................................ 1-1
1.1 Introduction ................................................................................ 1-1
1.2 The MA “02” Series Amplifiers ................................................... 1-1
1.3 Scope ................................................................
MA-5002VZ Service Manual VI
130446-1 Rev. A
©2000 Crown International, Inc.
5 Maintenance........................................................................... 5-1
5.1 Cautions and Warnings.............................................................. 5-1
5.2 General Information ................................................................... 5-1
5.3 Troubleshooting ........................................................................ 5-1
5.3
130446-1 Rev. A MA-5002VZ Service Manual
©2000 Crown International, Inc.
1.1 Introduction
This manual contains complete service information on
the Crown® MA-5002VZ power amplifier. It is designed
to be used in conjunction with the Reference Manual;
however, some important information is duplicated in
this Service Manual in case the Reference Manual is
not readily available.
NOTE: THE INFORMATION IN THIS MANUAL IS
INTENDED FOR USE BY AN E
MA-5002VZ Service Manual 1-2 Introduction
130446-1 Rev. A
©2000 Crown International, Inc.
Figure 1.1 MA-5002VZ Front and Rear Views
130446-1 Rev. A MA-5002VZ Service Manual
©2000 Crown International, Inc.
Specifications
The following applies to 120-VAC, 60-Hz units in Stereo mode with 8-ohm loads and an
input sensitivity of 26-dB gain unless otherwise specified. Specifications for units
supplied outside the U.S.A. may vary slightly at different AC voltages and frequencies.
Power
Output Power
Load Impedance: Safe with all types of loads. Rated for 2 to 8
ohms in Ster
MA-5002VZ Service Manual 2-2 Specifications
130446-1 Rev. A
©2000 Crown International, Inc.
Figure 2.1 Dimensions
DC Output Offset: ±10 millivolts.
Output Signal
Stereo: Unbalanced, two-channel.
Bridge-Mono: Balanced, single-channel. Channel 1 controls are
active; Channel 2 controls are removed from operation.
Parallel-Mono: Unbalanced, single-channel. Channel 1 controls are
active; Channel 2 controls are by passed.
Protection
Macro-Tech amplifiers are p
130446-1 Rev. A MA-5002VZ Service Manual
©2000 Crown International, Inc.
Figure 2.3 Typical Frequency Response
Figure 2.4 Typical Damping Factor
Figure 2.5 Typical Output Impedance
MA-5002VZ Service Manual 2-4 Specifications
130446-1 Rev. A
©2000 Crown International, Inc.
This page intentionally left blank
Crown Macro-Tech MA-5002VZ Voltage Conversion 3-1
130446-1 Rev. A
MA-5002VZ Service Manual
©2000 Crown International, Inc.
3 Voltage Conversion
INSTRUCTIONS
CAUTION: Because there is a risk of
electric shock, only a qualified technician
should change the line voltage configuration.
1. Turn the amplifier off and disconnect it from the AC
power source. (The enable switch alone does not re-
move lethal voltage from the line cord.) Wait at least 10
seconds before proceeding.
2. Drain
MA-5002VZ Service Manual 3-2 Voltage Conversion
130446-1 Rev. A
©2000 Crown International, Inc.
CAUTION: To reduce the risk of fire,
replace F700, F701, & F702 with the
same type fuse. Use a 30 A fuse for F700
& F701 and a 1A fuse for F701 for ALL
voltage configurations.
ATTENTION: Utiliser un fusible de même
type (F700, F701 = 30A. F702 = 1A.)
pour toutes applications.
Figure 3.2 Voltage/Frequency Conversion Physical Layout
Circuit Theory 4-1
130446-1 Rev. A
MA-5002VZ Service Manual
©2000 Crown International, Inc.
4 Circuit Theory
4.1 Overview
It should be noted that over time Crown makes improve-
ments and changes to their products for various rea-
sons. This manual is up to date as of the time of writing.
For additional information regarding these amplifiers,
refer to the applicable Technical Notes provided by
Crown for this product. Sketches have been added to
this secti
MA-5002VZ Service Manual 4-2 Circuit Theory
130446-1 Rev. A
©2000 Crown International, Inc.
Figure 4.1 Simplified Grounded Bridge
by the output stages rather than the power supply.
Composite devices are constructed to function as gi-
gantic NPN and PNP devices since the available cur-
rents exceed the limits of existing individual devices.
The devices connected to the load are referred to as
“high-side NPN and PNP” and the devices connected
to ground
Circuit Theory 4-3
130446-1 Rev. A
MA-5002VZ Service Manual
©2000 Crown International, Inc.
full (negative) potential developed by the power sup-
ply.
The total effect is to deliver a peak to peak voltage to
the speaker load which is twice the (static) voltage pro-
duced by the power supply. Benefits include full utiliza-
tion of the power supply (it conducts current during both
halves of the output signal; conventional designs re-
quire two power supplie
MA-5002VZ Service Manual 4-4 Circuit Theory
130446-1 Rev. A
©2000 Crown International, Inc.
4.3 VZ Power Supply
VZ means Variable Impedance and is the name of
Crown’s patented articulated power supply technology.
It enables Crown to pack tremendous power into just
5.25 inches of vertical rack space.
A power supply must be large enough to handle the
maximum voltage and current necessary for the ampli-
fier to drive its maximum rated power into a specifie