Omron D41L Manual 

Text of the manual

High-Coded Guard Lock Safety Door Switch

D41L Keep your machines hygienic • Tamper-proof safety door switch to prevent human error • Hygienically designed switch Unique locking mechanism prevents water and foreign matter from collecting Smooth surface leaves no wiping unevenness • Complies with ISO 14119 (Type 4/High Coded), ISO 13849-1 (PLe) • ECO

Model Number Structure

Model Number Legend Safety Door Switch Sensor Actuator D41L - @ @ D @ @ - N2 (2) (3) (4) (5) (6) (1) Model L: Guard Lock (2) Coding level / Teaching limitation 1: High (Individual coding) 2: High (Individual coding, No limitation) (3) OSSD configuration Y: Guard monitoring AND lock monitoring Z: Only guard monitoring (4) Diagnos

List of Models

Sensors Actuator (Sold separately) Accessory (Sold separately) Connecting cables Mounting Classification (Lock and Release) Appearance Coding level / Teaching limitation OSSD configuration Emergency exit Model Power to unlock (Mechanical lock) High (Individual coding) Only guard monitoring - D41L-1ZDA-N2 High (Indiv

EU Declaration of Conformity

• Machinery Directive • RE Directive • RoHS Directive • WEEE Directive Dispose in accordance with applicable regulations. Standards • EN ISO 13849-1: PL e Category 4 • EN 60947-5-3 • IEC 61508 • EN 300 330 • EN ISO 14119 UL Certification • UL508 • CAN/CSA C22.2 No.14 Regions wh

Ratings and Specifications

Model D41L Technical Detection method RFID Frequency band 125 kHz Transmitter output -6 dBm max. Interlock type (ISO 14119) Type 4 Coded level (ISO 14119) D41L-1: High (individual coding) D41L-2: High (individual coding, No limitation) Actuator D41L-A1 Response time (ON to OFF) 100 ms max. Response time (input) 1.5 ms max. R

*1. Refer to Connection on page 10 for connection specifications with the Safety controller.

Mechanical Protection class III Switching frequency 0.5 Hz max. Rated insulation voltage (Ui) 32 VDC Rated impulse withstand voltage (Uimp) 0.8 kV Minimum operating current (Im) 0.5 mA Fixing screws 2 × M6 Tightening torque of fixing screws 6 to 7 N·m Latchi

Safety classification information

Note: 1. The actuation of the interlock must be compared with the external OSSD enabler. If a shut-down now occurs due to an unintentional unlocking this is detected by an external diagnostic. 2. The safety consideration of the guard locking function only applies for monitored safety door switch D41L-@Y. 3. If for a c

Structure and Nomenclature

Sensor and Actuator 1. High degree of protection against defeating due to the coded RFID sensor (also available with individual coding) 2. Dampener for door stop - saves costs: no additional mounting parts required 3. Star handle - adjustable latching force - 25 N or 50 N 4. Mounting hole for M6 screws 5. Connector plug M12,

The application examples shown are suggestions. They however do not release the user from carefully checking whether the safety door switch

and its set-up are suitable for the individual application. The power supply for the safety door switch must provide protection against permanent overvoltage. To that effe

Safety controller settings

Combination with a safety relay unit * Refer to the instruction manual or user’s manual of each product for how to extend the wiring. OMRON’s safety controller NX-SL and NX-SI GI-SMD/SID G9SP Input device setting Input device Semiconductor Output for Dual Channel Equivalent Semiconductor Output for Dual Channel Equivale