Dell 4300 Service Manual

Text of the manual

Information in this document is subject to change without notice.

© 1998 Dell Computer Corporation. All rights reserved. Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden. Trademarks used in this text: Dell, the DELL logo, and PowerEdge are registered trademarks and Dell OpenManage is a trademark of Dell Computer Corporation; IBM is a registered trademark of International Business Machines Corporation; Intel and Pentium are registered trademarks and MMX is a trademark of Intel Corporation. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Computer Corporation disclaims any proprietary interest in trademarks and trade names other than its own. September 1998 P/N 33667

6\VWHP2YHUYLHZ  

System Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Accessing the Interior of the System . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 System Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Advanced Expansion Subsystems . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 Video Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 Integrated SCSI Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 SCSI Hard-Disk Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 SCSI Configuration Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 SCSI ID Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 Device Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 PSPB and System Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 System Power Supplies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 PSPB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 Pin Assignments for the PSPB Power Connectors . . . . . . . . . . . . 1-12 System Board Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15 SCSI Backplane Board Layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16 System Board Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-17 Interrupt Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18 DMA Channel Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20 &KDSWHU %DVLF7URXEOHVKRRWLQJ  Initial User Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 External Visual Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Observing the Boot Routine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Internal Visual Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 Eliminating Resource Conflicts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Running the Dell Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Getting Help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7

POST Beep Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Alert Messages From Dell OpenManage HIP . . . . . . . . . . . . . . . . . . . . . . 3-13 SCSI Hard-Disk Drive Indicator Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17 &KDSWHU 5HPRYLQJDQG5HSODFLQJ3DUWV   Recommended Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 Precautionary Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Computer Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Front Bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 Control Panel Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 Externally Accessible Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Front-Panel Inserts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Close-Out Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Reorienting the External Drive Cage . . . . . . . . . . . . . . . . . . . . . . . . 4-8 5.25- and 3.5-Inch Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 Hard-Disk Drives in External Bay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 Hard-Disk Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 SCSI Backplane Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 System Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16 System Power Supply and PSPB Upgrade . . . . . . . . . . . . . . . . . . . . . . . . 4-17 Power-Supply Paralleling Board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21 System Cooling Fans. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22 Three-Fan Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23 Fan Power-Cable Bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24 Drive Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24 System Board Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25 System Board Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-26 Expansion Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-27 Interior Support Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-29 DIMMs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30 SEC Cartridge and Heat Sink Assembly . . . . . . . . . . . . . . . . . . . . . . . 4-31 Terminator Card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33 System Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34 System Board Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35 System Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36 Guide Bracket Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-37

System Setup Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2

,QGH[ )LJXUHV Figure 1-1. Computer Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Figure 1-2. Front-Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Figure 1-3. Back-Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Figure 1-4. Back/Right Side Internal View . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Figure 1-5. Opening the System Board Tray . . . . . . . . . . . . . . . . . . . . . . 1-6 Figure 1-6. DIMM Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Figure 1-7. Power-Supply Paralleling Board. . . . . . . . . . . . . . . . . . . . . . 1-11 Figure 1-8. PSPB Power Connector PWR1 . . . . . . . . . . . . . . . . . . . . . . 1-12 Figure 1-9. PSPB Power Connector PWR2 . . . . . . . . . . . . . . . . . . . . . . 1-13 Figure 1-10. PSPB Power Connector PWR3 . . . . . . . . . . . . . . . . . . . . . . 1-13 Figure 1-11. PSPB Power Connector FD. . . . . . . . . . . . . . . . . . . . . . . . . 1-13 Figure 1-12. PSPB Power Connector HD_B/P. . . . . . . . . . . . . . . . . . . . . 1-14 Figure 1-13. System Board Components . . . . . . . . . . . . . . . . . . . . . . . . 1-15 Figure 1-14. SCSI Backplane Board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16 Figure 1-15. System Board Jumpers. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-17 Figure 3-1. Hard-Disk Drive Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . 3-17 Figure 4-1. Computer Cover Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Figure 4-2. Front Bezel Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 Figure 4-3. Control-Panel Assembly Removal . . . . . . . . . . . . . . . . . . . . . 4-5 Figure 4-4. Drive Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 Figure 4-5. Front-Panel Inserts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Figure 4-6. Externally Accessible Drive Removal . . . . . . . . . . . . . . . . . . 4-9 Figure 4-7. Drive-Mounting Rail Removal (Example). . . . . . . . . . . . . . . 4-10 Figure 4-8. Hard-Disk Drives in External Bay. . . . . . . . . . . . . . . . . . . . . 4-11 Figure 4-9. Hard-Disk Drive Removal . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 Figure 4-10. SCSI Backplane Board Removal . . . . . . . . . . . . . . . . . . . . . 4-14 Figure 4-11. Power Supply Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16 Figure 4-12. Power Cable Connections — Single Power Supply . . . . . . 4-17 Figure 4-13. PSPB Tray Location in the System Chassis . . . . . . . . . . . . 4-18 Figure 4-14. PSPB Installation on the PSPB Tray . . . . . . . . . . . . . . . . . . 4-19 Figure 4-15. Power Cable Connections — Multiple Power Supplies . . . 4-20 Figure 4-16. Power-Supply Paralleling Board Removal . . . . . . . . . . . . . . 4-21 Figure 4-17. System Cooling Fans. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-22 Figure 4-18. Three-Fan Assembly Removal. . . . . . . . . . . . . . . . . . . . . . . 4-23 Figure 4-19. Drive Fan Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24 Figure 4-20. System-Board Fan Removal . . . . . . . . . . . . . . . . . . . . . . . . 4-25

System Board Components . . . . . . . . . . . . . . . . . . . . . . . . 4-26

Figure 4-22. Expansion-Card Access Door . . . . . . . . . . . . . . . . . . . . . . . 4-27 Figure 4-23. Expansion Card Removal . . . . . . . . . . . . . . . . . . . . . . . . . . 4-28 Figure 4-24. Interior Support Panel Removal . . . . . . . . . . . . . . . . . . . . . 4-29 Figure 4-25. DIMM Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30 Figure 4-26. DIMM Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-30 Figure 4-27. SEC Cartridge Release Latches . . . . . . . . . . . . . . . . . . . . . 4-31 Figure 4-28. SEC Cartridge and Heat Sink Removal . . . . . . . . . . . . . . . . 4-32 Figure 4-29. Terminator Card Removal . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33 Figure 4-30. System Battery Removal . . . . . . . . . . . . . . . . . . . . . . . . . . 4-34 Figure 4-31. System-Board Assembly Removal . . . . . . . . . . . . . . . . . . . 4-35 Figure 4-32. System Board Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-36 Figure 4-33. Guide-Bracket Assembly Removal . . . . . . . . . . . . . . . . . . . 4-37 Figure A-1. System Setup Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 7DEOHV Table 1-1. DC Voltage and Current Ranges . . . . . . . . . . . . . . . . . . . . . 1-10 Table 1-2. Power Cable Connections From the PSPB . . . . . . . . . . . . 1-11 Table 1-3. Jumper Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18 Table 1-4. Interrupt Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18 Table 1-5. DREQ Line Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 Table 1-6. Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20 Table 3-1. System Beep Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Table 3-2. System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Table 3-3. Dell OpenManage HIP Alert Log Messages . . . . . . . . . . . 3-13 Table 3-4. SCSI Hard-Disk Drive Indicator Patterns . . . . . . . . . . . . . . 3-18 Table A-1. System Setup Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3

A prerequisite for using this manual to service Dell computer systems is a basic

knowledge of IBM®-compatible PCs and prior training in IBM-compatible PC troubleshooting techniques. In addition to information provided in this manual and in the User’s Guide that came with the system, Dell provides the Installation and Troubleshooting Guide for troubleshooting procedures and instructions on using the Dell Diagnostics to test the computer system. :DUQLQJV&DXWLRQVDQG1RWHV Throughout this manual, there may be blocks of text printed in bold type or in italic type. These blocks are warnings, cautions, and notes, and they are used as follows: :$51,1*$:$51,1*LQGLFDWHVWKHSRWHQWLDOIRUERGLO\KDUPDQG SURYLGHVLQVWUXFWLRQVIRUKRZWRDYRLGWKHSUREOHP &$87,21$&$87,21LQGLFDWHVHLWKHUSRWHQWLDOGDPDJHWRKDUG ZDUHRUORVVRIGDWDDQGSURYLGHVLQVWUXFWLRQVIRUKRZWRDYRLGWKH SUREOHP NOTE: A NOTE provides helpful information about using the computer system.

& + $ 3 7 ( 5  

6\VWHP2YHUYLHZ Dell® PowerEdge® 4300 systems are feature-rich, enterprise-class server systems that use Intel® Pentium® II microprocessor(s) with MMX™ technology and incorporate high-performance PCI and AGP local buses as well as the ISA expansion bus. The PowerEdge 4300 systems have been designed for better serviceability and increased reliability. The sliding system board tray allows easy access to the system board for performing processor and memory upgrades. The Dell- designed SCSI backplane board and hard-disk drive carriers eliminate the extensive cabling and drive configuration usually required for a SCSI sub- system. The plastic drive rails attached to devices mounted in the external drive bays allow you to remove these devices without removing a single screw. The systems can be either freestanding or rack-mounted. A PowerEdge 4300 system can contain one or two Pentium II microproces- sors. Each processor is housed in a single-edge contact (SEC) cartridge/heat sink assembly mounted in a guide bracket on the system board, allowing for greater heat dissipation. The processor has an internal operating frequency of 350 or 400 MHz (or a higher speed when available) and an external operating frequency of 100 MHz. Contact Dell for information about Dell-supported microprocessor upgrades. 6\VWHP)HDWXUHV In addition to the standard features found in a traditional personal computer, Dell PowerEdge 4300 systems include the following new and/or advanced features: ‡ One or two Intel Pentium II microprocessors with an internal operating fre- quency of 350 or 400 MHz (or higher speed when available) and an external bus speed of 100 MHz. NOTE: Do not attempt to operate the system with the microprocessor set to a speed other than the specified rating. ‡ Support for symmetric multiprocessing (SMP) when two microprocessors are installed. NOTE: The second microprocessor must have the same internal operating frequency as the first microprocessor. Not all versions of the Pentium II microprocessor will work properly as an additional microprocessor in this

Dell PowerEdge 4300 Systems Service Manual

system; the upgrade kit from Dell contains the correct version for this system. ‡ A secondary (L2) cache of 512 KB of SRAM included within the SEC car- tridge that contains the microprocessor. ‡ 64-MB and 128-MB (unbuffered) main memory, upgradable to 512 MB, or upgradable to 1 GB using 256-MB registered SDRAM DIMMs. ‡ BIOS in upgradable flash memory on the ISA bus. ‡ Up to six hot-pluggable SCSI hard-disk drives. Two additional 1-inch drives can be installed in the optional removable media bay. ‡ Up to three redundant, hot-pluggable power supplies and a power-supply paralleling board (PSPB), which is necessary for systems with two or more power supplies. ‡ Five redundant system cooling fans. ‡ Six 32-bit PCI connectors and two shared 8-bit or 16-bit ISA connectors. ‡ PCI and AGP local buses and ISA bus. ‡ A VGA-compatible video subsystem with an ATI 3D Rage Pro AGP video controller. This video subsystem contains 2 MB of SGRAM video memory (nonupgradable). ‡ A National Semiconductor PC87309 super I/O controller that controls the bidirectional parallel port, two serial ports, and the diskette drive in the externally accessible front bay. ‡ An integrated Adaptec AIC-7890 Ultra2/LVD SCSI-3 host adapter that sup- ports up to six 1.6-inch internal SCSI hard-disk drives via a SCSI backplane board and special SCSI hard-disk drive carriers. NOTE: The 1.6-inch drive carriers will accommodate 1-inch drives. The SCSI backplane automatically configures SCSI ID numbers and SCSI termination on individual hard-disk drives, greatly simplifying drive installa- tion. The backplane supports hot-pluggable SCSI hard-disk drive installation and removal when used in conjunction with a PowerEdge Expandable RAID Controller. ‡ An integrated Adaptec AIC-7860 Ultra/Narrow SCSI-3 host adapter that supports the standard CD-ROM drive and two additional externally accessi- ble SCSI devices in the external hard-disk drive bays. ‡ Drive failure, online, and activity indicators visible on each hard-disk drive connected to the SCSI backplane. ‡ Server management circuitry that monitors operation of the system fans as well as critical system voltages and temperatures. The server manage- ment circuitry works in conjunction with the HP OpenView Network Node Manager Special Edition (NNM SE) and the Dell OpenManage™ Hardware Instrumentation Package (HIP). ‡ System board support for the Dell OpenManage Remote Assistant when the optional Dell Remote Assistant Card version 2 (DRAC 2), which pro- vides additional local and remote server management, is installed.

For a complete list of system features, see “Technical Specifications” found later in

this chapter. For information about installing the PowerEdge 4300 systems in a rack, see the Dell PowerEdge 6300 and PowerEdge 4300 Systems Rack Instal- lation Guide. When following the text in this manual, assume that the location or direction relative to the computer is as shown in Figure 1-1. Figures 1-2 through 1-4 illustrate front-panel, back-panel, and interior features of the PowerEdge 4300 systems. )LJXUH&RPSXWHU2ULHQWDWLRQ back of computer right side left side front of computer

Dell PowerEdge 4300 Systems Service Manual

)LJXUH)URQW3DQHO)HDWXUHV )LJXUH%DFN3DQHO)HDWXUHV power switch power indicator drive access indicators (3) power-supply status indicator hard-disk drive keylock diskette drive CD-ROM drive fan/temperature status indicator parallel port connector serial port 2 connector mouse connector keyboard connector serial port 1 connector video connector server management bus (SMB) connectors (2) external SCSI connector port (2) expansion slots (6) AC power receptacle optional redundant power supply

drive bays (6)

external drive bays (4) SCSI backplane board system board tray latch PCI expansion card support panel microprocessors hard-disk drive cooling fan assembly system board fans

Dell PowerEdge 4300 Systems Service Manual

$FFHVVLQJWKH,QWHULRURIWKH6\VWHP To access the SCSI backplane board or the PSPB, release the system-board tray latch at the back lower corner of the tray (see Figure 1-5) and pull the tray open to the first stop position (or service position). NOTE: From the service position, if you depress and release the tray latch and pull the tray out again, you will come to a second stop position that is used by manufacturing. To remove the tray completely from any position, depress the latch, hold it in, and pull the tray out of the chassis. )LJXUH2SHQLQJWKH6\VWHP%RDUG7UD\ system board tray SCSI backplane board tray latch

System memory has a minimum of 64 MB of 72-bit-wide, unbuffered memory.

The system memory capacity can be expanded up to 1 GB by using combina- tions of 64- and 128-MB unbuffered SDRAM DIMMs or 256-MB registered SDRAM DIMMs. NOTE: DIMMs must be rated to run at 100 MHz. The system board has four 168-pin DIMM sockets. The DIMMs do not have to be inserted in pairs. The socket population guidelines are as follows: ‡ Populate the DIMM sockets in order from DIMM_A (right) to DIMM_D (left). ‡ The largest-capacity DIMM should be in socket DIMM_A, with smaller- capacity DIMMs installed in decreasing sizes toward socket DIMM_D. ‡ Unbuffered and registered DIMMs cannot be mixed. Remove any 64- or 128-MB unbuffered DIMMs before installing 256-MB registered DIMMs. ‡ DIMMs support the ECC feature, which detects memory errors and cor- rects single-bit memory errors. The ECC feature provides more reliable memory and less downtime. The ECC feature is built into the memory con- troller on the system board. )LJXUH',006RFNHWV For more detailed information about DIMM installation guidelines and samples of DIMM configurations, see “Adding Memory” in Chapter 8 of the Dell PowerEdge 4300 Systems Installation and Troubleshooting Guide. See “DIMMs” in Chapter 4 of this document for information on removing and replacing DIMMs. DIMM_A socket

Dell PowerEdge 4300 Systems Service Manual

$GYDQFHG([SDQVLRQ6XEV\VWHPV The computer system offers advanced expansion subsystems that can support a mixture of traditional ISA expansion cards, Plug and Play ISA expansion cards, and PCI expansion cards. The Resource Configuration Utility (RCU) included with the system provides a means of avoiding resource conflicts that might arise from such an arrangement. After all legacy cards have been configured with the RCU, the system automat- ically assigns any required memory space, IRQ lines, and DMA channels to any installed Plug and Play ISA expansion cards and PCI expansion cards the next time the system is rebooted. Chapter 5, “Using the Resource Configuration Utility,” in the Dell PowerEdge 4300 Systems User’s Guide describes the RCU and provides instructions for using it to configure the system. The expansion-card slots include six PCI expansion-card connectors and two ISA expansion-card connectors. Two of the PCI connectors share expansion- card slots with the two ISA connectors. The expansion-card connectors are located on the system board (see Figure 1-13). 9LGHR&RQWUROOHU The video subsystem is built into the system board and consists of an AGP VGA-compatible video subsystem with an ATI 3D Rage Pro SVGA video controller. The video subsystem contains 2 MB of SGRAM video memory, which is not upgradable. Noninterlaced resolutions are 640 x 480 (16.7 million colors), 800 x 600 (16.7 million colors), and 1024 x 768 (256 colors). ,QWHJUDWHG6&6,&RQWUROOHUV An integrated Adaptec AIC-7890 Ultra2/LVD SCSI-3 host adapter supports up to six 1- or 1.6-inch internal SCSI hard-disk drives through a 68-pin connector on the system board for a SCSI backplane board. The SCSI backplane board automatically configures SCSI ID numbers and SCSI termination on individual hard-disk drives, greatly simplifying drive installation. The integrated SCSI con- troller resides on the PCI local bus for optimum performance. An integrated Adaptec AIC-7860 Ultra/Narrow SCSI-3 host adapter attached to the PCI bus supports up to three SCSI devices in the external drive bays through a 50-pin connector on the system board. 6&6,+DUG'LVN'ULYHV Dell PowerEdge 4300 systems include a SCSI backplane board, which greatly simplifies cabling and configuration for SCSI hard-disk drives. SCSI ID and ter- mination for SCSI hard-disk drives are both configured by the SCSI backplane board, rather than on individual drives. SCSI hard-disk drives are supplied by Dell in special drive carriers that fit in the internal drive bays. NOTE: For maximum performance, install Ultra2/LVD drives exclusively. Although you can install a mixture of Ultra2/LVD and Ultra hard-disk drives, they will operate at the slower Ultra transfer rate.

SCSI hard-disk drives must be configured as follows:

‡ Disable termination on the drive. The SCSI backplane board provides termi- nation for the SCSI bus. ‡ Set the SCSI ID on all drives to 0. All SCSI ID numbers for the drives are set by the SCSI backplane board. ‡ Configure the drive so that the drive motor waits for a start unit command from the SCSI host adapter before spinning. SCSI devices (except hard-disk drives) in the external drive bays are controlled by the Ultra/Narrow SCSI controller on the system board. Hard-disk drives in the external drive bays are controlled by a RAID controller or the Ultra2/LVD SCSI connector via a two-device ribbon cable from the external drive bay insert’s backplane board. Although SCSI devices are installed essentially the same way as other devices, their configuration requirements are different. To configure SCSI devices installed in the external bays, follow the guidelines in the following subsections. 6&6,,'1XPEHUV Each device attached to the Ultra/Narrow SCSI host adapter must have a unique SCSI ID number from 0 to 7. When SCSI devices are shipped from Dell, the SCSI ID defaults are assigned as follows: ‡ The integrated Ultra/Narrow SCSI host adapter is configured through the BIOS as SCSI ID 7. ‡ A SCSI tape drive is configured as SCSI ID 6 (the default for a tape drive). ‡ A SCSI CD-ROM drive is usually configured as SCSI ID 5. NOTE: There is no requirement that SCSI ID numbers be assigned sequentially or that devices be attached to the cable in order by ID number. 'HYLFH7HUPLQDWLRQ All Dell PowerEdge 4300 systems have an active terminator installed at the end of the SCSI cable. All of the devices attached to the SCSI cable should have their termination disabled. 363%DQG6\VWHP3RZHU6XSSOLHV The Dell PowerEdge 4300 system provides one (when available as an option), two, or three 320-W system power supplies and, when necessary, a PSPB. See “System Power Supply” or “System Power Supply and PSPB Upgrade” in Chapter 4 for the installation procedure for this option.

Dell PowerEdge 4300 Systems Service Manual

&$87,217ZRRUPRUHSRZHUVXSSOLHVDQGD363%PXVWEHLQVWDOOHG LQWKHV\VWHPLIDQ\RIWKHIROORZLQJV\VWHPRSWLRQVDUHLQVWDOOHG ‡ A second microprocessor ‡ Two or more RAID controller host adapter cards ‡ More than 512 MB of memory ‡ One or more 1.6-inch hard-disk drives ‡ Hard-disk drive carrier in the external drive bay 6\VWHP3RZHU6XSSOLHV The system power supplies are stacked at the rear of the chassis and can slide in and out of the unit. When fully installed, a power supply automatically mates with a power harness attached to the back plate of the power supply cage. The power harness connects the power supply to the PSPB. The power supplies can operate from an AC power source of 115 VAC at 60 Hz or 230 VAC at 50 Hz. They provide the DC operating voltages and currents listed in Table 1-1. NOTE: The power supplies produce DC voltages only under their loaded condi- tion. Therefore, when you measure these voltages, the DC power connectors must be mated to their PSPB harnesses at the bulkhead, and the harnesses must be connected to their corresponding power input connectors on the PSPB. The PSPB, in turn, must be connected as appropriate to the system board, SCSI backplane board, or external drive bay. . 363% The PSPB multiplexes input from the power supplies to supply redundant power to the system board, SCSI backplane, and external drive bays. Through embedded server management (ESM), the PSPB can also be used to perform such tasks as detecting the presence of one to three power supplies; monitor- ing voltage and current outputs from the power supplies, voltage going to the 7DEOH'&9ROWDJHDQG&XUUHQW5DQJHV 9ROWDJH 5DQJH 0D[LPXP2XWSXW&XUUHQW1 +3.3 VDC +3.23 to +3.45 VDC 18.0 A +5 VDC +4.90 to +5.25 VDC 40.0 A +12 VDC +11.40 to +12.60 VDC 16.0 A –12 VDC –10.80 to –13.20 VDC 0.52 A –5 VDC –4.50 to –5.50 VDC 0.32 A +5 VFP +4.85 to +5.35 VDC 0.4 A 1 Maximum continuous combined load on +5 VDC and +3.3 VDC outputs cannot exceed 240 W. 2 Maximum combined load current on –5 VDC and –12 VDC outputs cannot exceed 0.6 A.

system board, and fan rpm; and supporting the SMB_ALERT protocol used by

the server management bus. The PSPB connects to the power supplies through short harnesses that attach to the back of the power supply cages. The PSPB is attached to the side wall of the computer behind the external drive cage and is oriented in parallel with the system board. For information on removing and replacing the PSPB, see “Power-Supply Paralleling Board” in Chapter 4. Figure 1-7 shows the PSPB power connector layout; Table 1-2 shows the cable connections made from the PSPB. )LJXUH3RZHU6XSSO\3DUDOOHOLQJ%RDUG  7DEOH3RZHU&DEOH&RQQHFWLRQV)URPWKH363%  &RQQHFWRU &DEOH&RQQHFWLRQ PS1_PB1 and PS1_PB2 To the power connector on the first power supply PS2_PB1 and PS2_PB2 To the power connector on the second power supply PS3_PB1 and PS3_PB2 To the power connector on the third power supply system-board power cable connector (PWR2) system-board power cable connector (PWR1) system-board power cable connector (PWR3) SCSI backplane-board power cable connector (HD_B/P) external-drives power cable connector (FD) cable connectors – power supply #1 (PS1_PB1 [top] and PS1_PB2) cable connectors – power supply #2 (PS2_PB1 [top] and PS2_PB2) cable connectors – power supply #3 (PS3_PB1 [top] and PS3_PB2)

Dell PowerEdge 4300 Systems Service Manual

3LQ$VVLJQPHQWVIRUWKH363%3RZHU&RQQHFWRUV The power-supply output voltages can be measured at the back (wire side) of the connectors without being disconnected. In the following diagrams, volt- ages for the PSPB PWRx connectors are shown as measured at the system board; voltages for the PSPB FD connector are shown as measured at the PSPB; voltages for the PSPB HD_B/P connector are shown as measured at the SCSI backplane. 1 Pin 13 — SYS_PS_ON# should measure between +4.75 and +5.25 VDC except when the power button on the front panel is pressed, taking SYS_PS_ON# to its active-low state. 2 Pin 5 — SYS_PWR_GOOD should measure between +4.75 and +5.25 VDC when the power supply is operating to indicate that all power-supply output voltages are within the ranges specified in Table 1-1. )LJXUH363%3RZHU&RQQHFWRU3:5 PWR1 To POWER1 connector on system board PWR2 To POWER2 connector on system board PWR3 Not used FD To diskette drives and other devices in external drive bays HD_B/P To POWER connector on SCSI backplane board 7DEOH3RZHU&DEOH&RQQHFWLRQV)URPWKH363% FRQWLQXHG  &RQQHFWRU &DEOH&RQQHFWLRQ 13 14 15 16 17 common (black) +5 VDC (red) NC_TFSC (gray) +5 VDC (red) SYS_PS_ON #1 (gray) common (black) common (black) common (black) –5 VDC (white) +3.3 VDC (orange) 18 +5 VDC (red) 19 20 21 22 23 24 +5 VDC (red) 1 2 3 4 5 +12 VDC (yellow) +3.3 V_SENSE (orange) common (black) common (black) +5 VFP (violet) SYS_PWR_GOOD2 (gray) SENSE (black) +5 V_SENSE (red) common (black) –12 VDC (blue) 6 +5 VDC (red) 7 8 9 10 11 12 +3.3 VDC (orange)

+5 VDC (red)

common (black) +3.3 VDC (orange) 12C_ALRT_EXT# (gray) 8 common (black) +5 VDC (red) PRES_DET (gray) 9 10 11 12 13 14 +12 VDC (yellow) common (black) +5 VDC (red) common (black) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 common (black) +5 VDC (red) +12 VDC (yellow) +3.3 VDC (orange) +3.3 VDC (orange) +3.3 VDC (orange) +12 VDC (yellow) +5 VDC (red) common (black) common (black) common (black) common (black) common (black) common (black) common (black) common (black) common (black) common (black) 1 common (black) +12 VDC (yellow) common (black) +5 VDC (red) +12 VDC (yellow) common (black) +5 VDC (red) common (black) 5 6 4 3 2 8 7

Dell PowerEdge 4300 Systems Service Manual

)LJXUH363%3RZHU&RQQHFWRU+'B%3 1 common (black) +12 VDC (yellow) common (black) +12 VDC (yellow) 2 3 4 5 6 7 8 +3.3 VDC (orange) common (black) +12 VDC (yellow) common (black) 9 NC_I2C_ALRT# (gray) +5 VDC (red) common (black) +5 VDC (red) 10 11 12 13 14 15 16 NC_I2C_SCL_EXT (gray) NC_I2C_SDA_EXT (gray) common (black) +5 VDC (red)

Figure 1-13 illustrates the location of important system board components. The

subsections that follow provide service-related information about the system board components. )LJXUH6\VWHP%RDUG&RPSRQHQWV video connector (JVGA) parallel port connector (PARALLEL) serial port connectors (2) (SERIAL1 [top] and SERIAL2) keyboard and mouse connectors (KYBD/MOUSE) diskette-drive interface connector (FLOPPY) secondary microprocessor (PROCESSOR 2) battery connector (BATTERY) Ultra/Narrow SCSI connector (SCSI2) DIMM sockets (DIMM_A [right]–DIMM_D) speed and configuration jumpers fan connectors (FAN1, FAN2) front of system board primary microprocessor (PROCESSOR 1) ISA connectors (ISA5 [top] and ISA6) primary PCI connectors (PCI1 [top] through PCI4) power input connector (POWER1) secondary PCI connectors (PCI5 [top] and PCI6) Ultra2/LVD SCSI connector (SCSI1) chassis-intrusion switch connector (INTRUS2) SCSI backplane board interface connector (BACKPLANE) server management bus connector (XSMB_IN) server management bus connector (XSMB_OUT) Dell Remote Assistant Card connector (SVR_MGT) hard-disk drive activity indicator connector (HLED) storage-system server-management bus connector (SDS_SMB) power input connector (POWER2) system-board power indicator (STANDBY_LED)

Dell PowerEdge 4300 Systems Service Manual

6&6,%DFNSODQH%RDUG/D\RXWV Figure 1-14 shows the location of the connectors on the SCSI backplane board.  )LJXUH6&6,%DFNSODQH%RDUG &$87,21,I\RXUHPRYHSRZHUIURPWKH6&6,EDFNSODQHERDUG HLWKHUE\UHPRYLQJWKHSRZHUFDEOHRUGXULQJUHSODFHPHQWRIWKH V\VWHPERDUGEDWWHU\ \RXPD\QHHGWRUHIODVKWKHV\VWHP·V ILUPZDUH 7KHRULJLQDOILUPZDUHRQWKH6&6,EDFNSODQHLVVWRUHGLQ((3520 +RZHYHULIWKH6&6,EDFNSODQHILUPZDUHLVHYHUXSGDWHGWKHXSGDWH LVVWRUHGLQYRODWLOH5$0,ISRZHULVUHPRYHGIURPDQXSGDWHGEDFN SODQHERDUGWKHXSGDWHLVORVWDQGWKHERDUGUHYHUWVWRLWVRULJLQDO ILUPZDUHLQ((3520 ,IDWV\VWHPVWDUWXS\RXUHFHLYHWKHPHVVDJH:DUQLQJ )LUPZDUH LVRXWRIGDWH, SOHDVHXSGDWH'HOOUHFRPPHQGVWKDW\RX UHIODVKDOOV\VWHPILUPZDUHIURPWKH'HOO6HUYHU$VVLVWDQW&' Ultra2/LVD SCSI cable connector (SCSI) power input connector (POWER) system-board data cable connector (PLANAR) SCA-2¤compatible SCSI connectors on reverse side (SLOT0 through SLOT5) cooling-fan power cable connector (FAN)

Figure 1-15 illustrates the location of the system board jumpers, and Table 1-3

describes the jumper settings.  )LJXUH6\VWHP%RDUG-XPSHUV jumpered unjumpered

Dell PowerEdge 4300 Systems Service Manual

,QWHUUXSW$VVLJQPHQWV Table 1-4 lists the default IRQ line assignments. 7DEOH-XPSHU'HVFULSWLRQV  -XPSHU 6HWWLQJV CARDBIOS Not installed (default) to allow normal boot operation from the system BIOS. Install the jumper only to boot the sys- tem from a BIOS expansion card. ISA_CLR Not installed (default) to retain the ISA configuration set- tings at system boot. Install the jumper and boot the computer to clear the ISA configuration settings. Remove the jumper before restoring ISA configuration information. PASSWD Installed (default) to enable the password feature. Remove the jumper and boot the computer to remove an existing password. 333MHZ Do not install. 350MHZ Installed only if the microprocessor’s internal speed is 350 MHz. 400MHZ Installed only if the microprocessor’s internal speed is 400 MHz. 450MHZ Installed only if the microprocessor’s internal speed is 450 MHz (when available). RSVD1 Do not install. Reserved for future microprocessor speed. RSVD2 Do not install. Reserved for future microprocessor speed. 7DEOH,QWHUUXSW$VVLJQPHQWV ,54/LQH 8VHG$YDLODEOH IRQ0 Used by the system timer IRQ1 Used by the keyboard to signal that the output buffer is full IRQ2 Used by interrupt controller 1 to enable IRQ8 through IRQ15 IRQ3 Used by serial port 2 (COM2 and COM4) IRQ4 Used by serial port 1 (COM1 and COM3) IRQ5 Available unless used by a secondary parallel port IRQ6 Used by the diskette drive controller IRQ7 Used by the primary parallel port IRQ8 Used by the RTC IRQ9 Used for power management functions IRQ10 Available

Table 1-5 lists the default DMA channel assignments.

IRQ11 Available IRQ12 Used by the PS/2 mouse port unless mouse is disabled in System Setup program IRQ13 Used by the math coprocessor IRQ14 Available IRQ15 Used by embedded server-management functions 7DEOH'5(4/LQH$VVLJQPHQWV '5(4/LQH 8VHG%\$YDLODEOH DREQ0 Available DREQ1 Available DREQ2 Generated by super I/O controller to initiate DMA cycle for attached diskette drive DREQ3 Available DREQ4 Generated by bus controller chip to activate second DMA controller DREQ5 Available DREQ6 Available DREQ7 Available 7DEOH,QWHUUXSW$VVLJQPHQWV FRQWLQXHG ,54/LQH 8VHG$YDLODEOH

Dell PowerEdge 4300 Systems Service Manual

7HFKQLFDO6SHFLILFDWLRQV Table 1-6 lists detailed technical specifications. 7DEOH7HFKQLFDO6SHFLILFDWLRQV  0LFURSURFHVVRU Microprocessor type . . . . . . one or two Intel Pentium II microprocessors Microprocessor speed. . . . . 350 or 400 MHz (100 MHz externally); 450 MHz (100 MHz externally) (when available) Internal cache . . . . . . . . . . . 32-KB L1 cache; 512-KB L2 cache Math coprocessor . . . . . . . . internal to the microprocessor 6\VWHP,QIRUPDWLRQ System chip set . . . . . . . . . . Intel 443BX controller chip set Data bus width . . . . . . . . . . 64 bits Address bus width. . . . . . . . 32 bits ([SDQVLRQ%XV Bus types. . . . . . . . . . . . . . . PCI and AGP local buses and ISA bus Bus speed . . . . . . . . . . . . . . AGP: 66.67 MHz PCI: 33.33 MHz ISA: 8.33 MHz Expansion-card connectors. . . . . . . . . . . . . . six 32-bit PCI (four full-length dedicated and two full-length shared) and two shared 8- or 16-bit ISA (full-length) slots 6\VWHP&ORFNV System clock . . . . . . . . . . . . 100 MHz Diskette/ communications ports . . . . . 48 MHz from the system clock SCSI channels . . . . . . . . . . . two 40-MHz channels 0HPRU\ Architecture . . . . . . . . . . . . . 72-bit (64 data bits plus 8 ECC bits), unbuf- fered SDRAM DIMMs or registered SDRAM DIMMs; DIMMs must be rated for 100-MHz operation DIMM sockets . . . . . . . . . . . four 168-pin sockets DIMM capacities . . . . . . . . . 64- and 128-MB (unbuffered) and 256-MB (registered) Standard RAM . . . . . . . . . . . 64 MB (minimum) Maximum RAM . . . . . . . . . . 1 GB

BIOS address. . . . . . . . . . . .

F000:0000h–F000:FFFFh External cache . . . . . . . . . . . none ,QWHJUDWHG6&6,&RQWUROOHUV Types . . . . . . . . . . . . . . . . . . Adaptec AIC-7890 Ultra2/LVD (Fast-40) con- troller, with integrated 68-pin SCSI connector on the system board; Adaptec AIC-7860 Ultra/Narrow controller, with integrated 50-pin SCSI connector on the system board 'ULYH%D\V Externally accessible bays . . . . . . . . . . . . . . . . . . . one 3.5-inch bay dedicated to a diskette drive; one 5.25-inch bay (upper bay) containing a CD-ROM drive; two 5.25-inch bays for op- tional devices. Optional cage can be installed in the two option bays to support two addi- tional hard-disk drives. Internally accessible bays . . . . . . . . . . . . . . . . . . . six bays for SCSI hard-disk drives 3RUWV Externally accessible: Serial (DTE) . . . . . . . . . . two 9-pin connectors (16550-compatible) Parallel . . . . . . . . . . . . . . one 25-pin connector (bidirectional) Video . . . . . . . . . . . . . . . one 15-pin connector (VGA-compatible) PS/2-style keyboard . . . . 6-pin mini-DIN PS/2-compatible mouse . . . . . . . . . . . . . . 6-pin mini-DIN Server-management bus daisy-chain connector. . . . . . . . . . . . two modular 8-pin connectors Internally accessible: Ultra2/LVD SCSI controller . . . . . . . . . . . . 68-pin connector Ultra/Narrow SCSI controller . . . . . . . . . . . . 50-pin connector Diskette drive . . . . . . . . . 34-pin connector Storage-system server- management bus connector. . . . . . . . . . . . 6-pin header connector 7DEOH7HFKQLFDO6SHFLILFDWLRQV FRQWLQXHG 

Dell PowerEdge 4300 Systems Service Manual

&RQWUROVDQG,QGLFDWRUV Power control. . . . . . . . . . . . push-button behind drive door on front panel Power indicator . . . . . . . . . . green LED behind drive door on front panel Fan/temperature status indicator . . . . . . . . . . . . . . . . green LED on front panel (blinks amber for fan failure or out-of-bounds temperature) Power-supply status indicator . . . . . . . . . . . . . . . . green LED on front panel (blinks amber for power supply or system voltage fault) Drive online indicator . . . . . . green LED on each SCSI drive carrier Drive activity indicator . . . . . green LED on each SCSI drive carrier Drive failure indicator . . . . . . amber LED on each SCSI drive carrier (blinks if drive failure is detected) 9LGHR Video type . . . . . . . . . . . . . . ATI 3D Rage Pro AGP video controller; VGA connector Video memory (standard). . . . . . . . . . . . . . . 2 MB (not upgradable) 3RZHU DC power supply: Wattage . . . . . . . . . . . . . 320 W per supply (up to three) Voltage. . . . . . . . . . . . . . 115 V at 60 Hz; 230 V at 50 Hz Backup battery. . . . . . . . . . . 3.0-V CR2032 lithium coin cell 3K\VLFDO Height (with support feet) . . . . . . . . . . . . . . . . . . . 44.5 cm (17.5 inches) Width. . . . . . . . . . . . . . . . . . 30.5 cm (12.0 inches) Depth. . . . . . . . . . . . . . . . . . 71.1 cm (28.0 inches) Weight (maximum configuration). . . . . . . . . . . . 50.0 kg (110.0 lb) 7DEOH7HFKQLFDO6SHFLILFDWLRQV FRQWLQXHG 

Operating . . . . . . . . . . . .

10° to 35°C (50° to 95°F) Storage . . . . . . . . . . . . . –40° to 65°C (–40° to 149°F) Relative humidity. . . . . . . . . . . . . 8% to 80% (noncondensing) Maximum vibration: Operating . . . . . . . . . . . . 0.25 G at 3 to 200 Hz for 15 min Storage . . . . . . . . . . . . . 0.5 G at 3 to 200 Hz for 15 min Maximum shock: Operating . . . . . . . . . . . . six shock pulses in the positive and nega- tive x, y, and z axes at 50 G for 2 ms Storage . . . . . . . . . . . . . six shock pulses in the positive and nega- tive x, y, and z axes at 92 G for 2 ms Altitude: Operating . . . . . . . . . . . . –16 to 3048 m (–50 to 10,000 ft) Storage . . . . . . . . . . . . . –16 to 10,600 m (–50 to 35,000 ft) 7DEOH7HFKQLFDO6SHFLILFDWLRQV FRQWLQXHG 

& + $ 3 7 ( 5  

%DVLF7URXEOHVKRRWLQJ This chapter describes basic troubleshooting procedures that can help you diagnose a computer system problem. These procedures can often reveal the source of a problem or indicate the correct starting point for troubleshooting the system. For a brief explanation of how to load and start the system diag- nostics, see “Running the Dell Diagnostics” found later in this chapter. Dell recommends that you perform the following procedures in the order they are presented in this manual. :$51,1*7KHSRZHUVXSSOLHVLQWKLVFRPSXWHUV\VWHPSURGXFHKLJK YROWDJHVDQGHQHUJ\KD]DUGVZKLFKFDQFDXVHERGLO\KDUP2QO\ WUDLQHGVHUYLFHWHFKQLFLDQVDUHDXWKRUL]HGWRUHPRYHWKHFRPSXWHU FRYHUDQGDFFHVVDQ\RIWKHFRPSRQHQWVLQVLGHWKHFRPSXWHU ,QLWLDO8VHU&RQWDFW When you first contact a user who has a problem, ask the user to describe the problem and the conditions under which it occurs. A verbal description can often indicate the cause of a problem or indicate the appropriate troubleshoot- ing procedure to use. After the user describes the problem, follow these steps: 1. Ask the user to back up any data on the hard-disk drive if the system’s con- dition permits. Appendix C, “Maintaining the System,” in the User’s Guide provides infor- mation about backing up data. 2. Ask the user to try to duplicate the problem by repeating the operations he or she was performing at the time the problem occurred. Can the user duplicate the problem? Yes. Proceed to step 3. No. Proceed to the next section, “External Visual Inspection.”

Dell PowerEdge 4300 Systems Service Manual

3. Observe the user to determine if he or she is making an error, such as typ- ing an incorrect key combination or entering a command incorrectly. Is the problem a result of user error? Yes. Instruct the user in the proper procedure, or direct him or her to the appropriate user documentation for the correct procedure. No. Proceed to the next section, “External Visual Inspection.” ([WHUQDO9LVXDO,QVSHFWLRQ The external visual inspection consists of a quick inspection of the exterior of the computer, the monitor, the keyboard, any peripherals, and cables. While performing the visual inspection, make any necessary corrections. To perform the external visual inspection, follow these steps: 1. Turn off the computer, the monitor, and all peripherals. 2. Verify that all power cables are properly connected to the computer, the monitor and peripherals, and their power sources. 3. Verify that the keyboard and mouse interface cables are firmly attached to the proper connectors on the back of the computer. For a PS/2-compatible mouse, the keyboard and mouse interface cable connectors are identical except for their labels. If needed, see “System Features” in Chapter 1. For a serial mouse, the mouse interface cable must be firmly attached to one of the serial port connectors, and its captive screws must be secure enough to ensure a firm connection. 4. If any network cables are present, verify that they are attached properly. 5. Verify that any devices attached to the serial and parallel port connectors are properly connected. Each of the serial and parallel port interface cables must be firmly attached to an appropriate connector on the back of the computer as well as to the interface connector on the device. The captive screws that secure these connectors at each end of the interface cable must be secure enough to ensure a firm connection. 6. Verify that the video interface cable is firmly attached to the video connec- tor on the back panel or to a video expansion card, and also to the connector on the back of the monitor. For proper connection of the video monitor, see the documentation for the monitor.

Inspect all external monitor controls for any obvious damage or improper

settings. For proper settings of the video monitor controls, see the documentation for the monitor. 8. Inspect the keyboard to ensure that no keys are sticking. If one or more keys are sticking, it may be necessary to replace the keyboard. 9. Inspect the exterior of the computer, including all controls and indicators, and all user-accessible data storage devices for any signs of physical damage. Does the inspection reveal any problems? Yes. Proceed to the appropriate procedure in Chapter 4, “Removing and Replacing Parts.” No. Proceed to the next section, “Observing the Boot Routine.” 2EVHUYLQJWKH%RRW5RXWLQH After you have performed an external visual inspection as described in the pre- vious section, you should boot the system and, while the boot routine is running, observe the system for any indications of problems. NOTES: Most of the steps in this procedure require observation of system functions and indications, some of which can occur simultaneously. It may be necessary to reboot the system several times to complete all of these steps. To perform the following procedure, you need a Dell Diagnostics Diskette cre- ated from the Dell Server Assistant CD. If such a diskette is not available, you can create it as described in “Create Diskettes” in Chapter 2 of the User’s Guide. If a separate diagnostics diskette is included with the system, you may need to use that diskette. To observe problem indications during the boot routine, follow these steps: 1. If the system is off, turn on all peripherals and the computer. Insert the Dell Diagnostics Diskette into the diskette drive and reboot the system. 2. Check each power supply fan. Does the fan run normally? Yes. Proceed to step 3. No. Troubleshoot the system power supplies.

Dell PowerEdge 4300 Systems Service Manual

3. Watch the Num Lock, Caps Lock, and Scroll Lock indicators on the upper- right corner of the keyboard. After all three indicators flash momentarily, and following a long pause (approximately 30 seconds), the Num Lock indi- cator should light up and remain on (unless the Num Lock option is set to Off in the System Setup program). Do these indicators flash on and off within approximately 10 seconds after the boot routine starts? Yes. Proceed to step 4. No. Troubleshoot the system power supplies. If the troubleshooting pro- cedure indicates that the system power supplies are operational, troubleshoot the memory. 4. During the boot routine, observe the system for any of the following: ‡ Beep codes: A beep code is a series of beeps that indicates an error condition. If the system emits a beep code, see Table 3-1 later in this manual. ‡ System error messages: These messages can indicate problems or provide status information. If a system error message is displayed, see Table 3-2 later in this manual. ‡ Diskette-drive and hard-disk drive access indicators: These indicators light up in response to data being transferred to or from the drives. If either of these indicators fails to light up during the boot routine, troubleshoot the diskette drive or hard-disk drive subsystem, as appropriate. 5. Observe the monitor screen for the Diagnostics Menu. Does the Diagnostics Menu appear? Yes. See “Running the Dell Diagnostics” found later in this chapter. No. Proceed to step 6. 6. Insert another copy of the Dell Diagnostics Diskette into the diskette drive, and reboot the system. Does the Diagnostics Menu appear? Yes. See “Running the Dell Diagnostics” found later in this chapter. No. Proceed to the next section, “Internal Visual Inspection.”

A simple visual inspection of a computer’s interior hardware can often lead to

the source of a problem, such as a loose expansion card, cable connector, or mounting screw. When you perform the visual inspection, refer to “System Features” in Chapter 1 to locate components referenced in the inspection procedure. To perform the internal visual inspection, follow these steps: 1. Turn off the system, including any attached peripherals, and disconnect all the AC power cables from their power sources. :$51,1*%HIRUHEHJLQQLQJWRZRUNLQVLGHWKHFRPSXWHUGLVFRQQHFW WKHSRZHUVXSSO\IURPWKHSRZHUVRXUFHDQGWKHSRZHUVXSSO\FDEOHV IURPWKHSRZHUVXSSO\ 2. Remove the computer’s right side cover as described in “Computer Cover” in Chapter 4. :$51,1*7KH6(&FDUWULGJHDQGKHDWVLQNDVVHPEO\FDQJHW H[WUHPHO\KRWGXULQJV\VWHPRSHUDWLRQV%HVXUHWKDWLWKDVKDGVXIIL FLHQWWLPHWRFRROEHIRUHWRXFKLQJLW :$51,1*:KHQKDQGOLQJWKH6(&FDUWULGJHDQGKHDWVLQNDVVHP EO\WDNHFDUHWRDYRLGVKDUSHGJHVRQWKHKHDWVLQN 3. Verify that the chips, DIMMs, expansion cards, and SEC cartridge and heat sink assembly or assemblies are fully seated in their sockets or connectors. To ensure that the chips are fully seated in their sockets, press firmly on the top of each chip. To reseat an SEC cartridge and heat sink assembly, remove and re- install it as described in “SEC Cartridge and Heat Sink Assembly” in Chapter 4. To reseat a DIMM, remove it from its socket and reinstall it as described in “DIMMs” in Chapter 4.

Dell PowerEdge 4300 Systems Service Manual

If you need to reseat an expansion card, remove the card as described in “Expansion Cards” in Chapter 4, and then reinsert the card in its connector and carefully push it in until fully seated. 4. Verify that all jumpers are set correctly. For information about jumper settings, see “System Board Jumpers” in Chapter 1. 5. Check all cable connectors inside the computer to verify that they are firmly attached to their appropriate connectors. 6. Reinstall the computer cover. 7. Reconnect the computer and any attached peripherals to their power sources, and turn them on. Does the problem appear to be resolved? Yes. No further steps are necessary. No. Proceed to the next section, “Eliminating Resource Conflicts,” and to “Getting Help” found later in this chapter. (OLPLQDWLQJ5HVRXUFH&RQIOLFWV Devices within the computer may require dedicated memory spaces, interrupt levels, or DMA channels, all of which must be allocated during installation of the devices. Because devices may be installed at different times, it is possible that the same resource is assigned to two or more devices. Resource conflicts can result in disorderly or erratic system operation or sys- tem failure. If you suspect that resource conflicts might exist, check the system and reassign the resources as necessary. For additional information, see Chapter 5, “Using the Resource Configuration Utility,” in the User’s Guide or “Interrupt Assignments” and “DMA Channel Assignments” in Chapter 1 of this manual. 5XQQLQJWKH'HOO'LDJQRVWLFV The Dell Diagnostics contains tests that aid in troubleshooting all major com- ponents of the computer system. To run the tests, you must first create the Dell Diagnostics Diskette using the Dell Server Assistant CD as described in “Create Diskettes” in Chapter 2 of the User’s Guide. If a separate Dell Diag- nostics Diskette is included with the system, you may need to use that diskette. To start the Dell Diagnostics, turn off the system, insert the Dell Diagnostics Diskette into the diskette drive, and then turn on the system.

Starting the diagnostics causes the Dell logo screen to appear on the monitor

screen, followed by a message indicating that the diagnostics is loading. Before the diagnostics loads, a program tests the portion of main memory (RAM) required for loading the diagnostics. If a RAM error is detected, a mes- sage telling you which DIMM has failed appears on the screen. If no errors are found in RAM, the diagnostics loads and the Diagnostics Menu appears. This menu lets you choose the following options or exit the Dell Diagnostics: ‡ Run All Tests — Runs all tests for a thorough check of the system ‡ Run Quick Tests — Runs selected tests from all test groups to quickly locate a failure or to indicate where further testing is needed to isolate a failure ‡ Run Specific Tests — Tests a particular area or subsystem *HWWLQJ+HOS If none of the troubleshooting procedures in this chapter or the tests in the Dell Diagnostics reveals the source of the problem or leads to the proper troubleshooting steps for determining the source of the problem, refer to the Support site at www.dell.com or call Dell for technical assistance. For instruc- tions on contacting Dell, see the chapter titled “Getting Help” in the Installation and Troubleshooting Guide.

Codes and Messages

3-1 & + $ 3 7 ( 5   &RGHVDQG0HVVDJHV This chapter describes beep codes, system messages, alert messages from the Dell OpenManage Hardware Instrumentation Package (HIP) application program, and SCSI hard-disk drive indicator codes that can occur during the POST or during normal system operation. If a faulty system does not emit beep codes or display system messages to indicate a failure, you should use the Dell Diagnostics to run the appropriate tests to help isolate the source of the problem. See Chapter 5, “Running the Dell Diagnostics,” in the Installation and Troubleshooting Guide. 3267%HHS&RGHV If the monitor cannot display error messages during the POST, the system may emit a series of beeps that identifies the problem or that can help you identify a faulty component or assembly. Table 3-1 lists the beep codes that may be generated during the POST. Most beep codes indicate a fatal error that pre- vents the system from completing the boot routine until the indicated condition is corrected. When the system emits a beep code, record the code and then find it in Table 3-1. If the table does not lead to the source of the problem, run the appropriate tests in the Dell Diagnostics to assist in troubleshooting the problem.

Dell PowerEdge 4300 Systems Service Manual

7DEOH6\VWHP%HHS&RGHV &RGH &DXVH &RUUHFWLYH$FWLRQ 1-1-3 NVRAM write/read failure Replace the system board. 1-1-4 BIOS checksum failure This fatal error usually requires that you reflash the BIOS firmware. If the problem persists, replace the system board. 1-2-1 1-2-2 1-2-3 Programmable interval-timer failure DMA initialization failure DMA page register write/read failure Replace the system board. 1-3-1 Main-memory refresh verification failure Remove and reseat the DIMMs. If the problem persists, replace the DIMMs. If the problem still per- sists, replace the system board. 1-3-2 1-3-3 1-3-4 1-4-1 1-4-2 2-1-1 through 2-4-4 No memory installed Chip or data line fail- ure in the first 64 KB of main memory Odd/even logic fail- ure in the first 64 KB of main memory Address line failure in the first 64 KB of main memory Parity failure in the first 64 KB of main memory Bit failure in the first 64 KB of main memory Remove and reseat the DIMMs. If the problem persists, replace the DIMMs. If the problem still per- sists, replace the system board.

Codes and Messages

3-3 3-1-1 3-1-2 3-1-3 3-1-4 Slave DMA-register failure Master DMA- register failure Master interrupt- mask register failure Slave interrupt-mask register failure Replace the system board. 3-2-4 Keyboard-controller test failure Check the keyboard cable and con- nector for proper connection. If the problem persists, replace the sys- tem board. 3-3-1 CMOS failure Replace the system board. 3-3-2 3-3-3 System configura- tion check failure Keyboard controller not detected Replace the system board. 3-3-4 3-4-1 3-4-2 Screen initialization failure Screen-retrace test failure Search for video ROM failure Run the Video test group in the Dell Diagnostics. 4-2-1 4-2-2 4-2-3 No timer tick Shutdown failure Gate A20 failure Replace the system board. 4-2-4 Unexpected inter- rupt in protected mode Ensure that all expansion cards are properly seated, and then reboot the system. 4-3-1 Faulty or improperly seated DIMM Remove and reseat the DIMMs. If the problem persists, replace the DIMMs. 4-3-3 Defective system board Replace the system board. 4-3-4 Time-of-day clock stopped Replace the battery. If the problem persists, replace the system board. 7DEOH6\VWHP%HHS&RGHV FRQWLQXHG &RGH &DXVH &RUUHFWLYH$FWLRQ

Dell PowerEdge 4300 Systems Service Manual

4-4-1 4-4-2 Super I/O controller failure Parallel-port test failure (defective system board) Replace the system board. 4-4-3 4-4-4 Math coprocessor failure (defective microprocessor) Cache test failure (defective microprocessor) Replace the microprocessor. 7DEOH6\VWHP%HHS&RGHV FRQWLQXHG &RGH &DXVH &RUUHFWLYH$FWLRQ

Codes and Messages

3-5 6\VWHP0HVVDJHV Table 3-2 lists (in alphabetical order) system messages that can appear on the monitor screen. These messages can help you find the source of a problem. Some of these messages indicate fatal errors. When a fatal error occurs, the system cannot usually be rebooted until an appropriate hardware change has been made. 7DEOH6\VWHP0HVVDJHV 0HVVDJH &DXVH &RUUHFWLYH$FWLRQ $PD[LPXPRI VL[KDUG GULYHVLV DOORZHGZLWK RQHSRZHU VXSSO\ Attempted to run system with more than six hard-disk drives and only one power supply Install a PSPB with addi- tional power supplies. $GGUHVVPDUN QRWIRXQG Faulty diskette/tape drive subsystem or hard-disk drive sub- system (defective system board) Replace the system board. $OHUW 8QEXIIHUHG DQGUHJLV WHUHG',00V FDQQRWEH PL[HG Combination of un- buffered and registered DIMMs installed Replace one or more DIMMs so that all DIMMs are the same type. See “Installing DIMMs” and “Removing DIMMs” in Chapter 8 of the system’s Installation and Troubleshooting Guide. $WWDFKPHQW IDLOHGWR UHVSRQG Diskette drive or hard-disk drive con- troller cannot send data to associated drive Replace the drive’s inter- face cable. $X[LOLDU\ GHYLFH IDLOXUH Mouse cable con- nector loose or improperly connected; defective mouse Check the mouse cable connection. If the prob- lem persists, replace the mouse. %DGHUURU FRUUHFWLRQ FRGH (&& RQ GLVNUHDG &RQWUROOHU KDVIDLOHG Faulty diskette/tape drive subsystem or hard-disk drive sub- system (defective system board) Replace the system board.

Dell PowerEdge 4300 Systems Service Manual

'DWDHUURU Faulty diskette, diskette drive, or hard-disk drive Replace the diskette, dis- kette drive, or hard-disk drive. 'HFUHDVLQJ DYDLODEOH PHPRU\ Faulty or improperly seated DIMM Remove and reseat the DIMMs. If the problem persists, replace the DIMMs. 'LVNHWWH GULYHVHHN IDLOXUH 'LVNHWWH GULYHVHHN IDLOXUH Faulty or improperly inserted diskette, incorrect configura- tion settings in System Setup program, loose diskette/tape drive interface cable, or loose power cable Replace the diskette. Run the System Setup program to correct the diskette drive type. Check the diskette/tape drive interface cable and power cable connec- tions to the drive. 'LVNHWWHUHDG IDLOXUH Faulty diskette, faulty or improperly connected diskette/ tape drive interface cable, or loose power cable Check the diskette/tape drive interface cable and power cable connec- tions to the drive. Replace the diskette drive interface cable. 'LVNHWWHVXE V\VWHPUHVHW IDLOHG Faulty diskette/tape drive controller (defective system board) Replace the system board. 'LVNHWWH ZULWH SURWHFWHG Diskette write- protect feature activated Move the write-protect tab on the diskette. 'ULYHQRW UHDG\ Diskette missing from or improperly inserted in diskette drive Reinsert or replace the diskette. (&&KRVWEXV SDULW\LQWHU UXSWDW DGGUHVV Defective system board Replace the system board. (&&PHPRU\ SDULW\LQWHU UXSWDW DGGUHVV Faulty or improperly seated DIMM or defective system board Remove and reseat the DIMMs. If the problem persists, replace the DIMMs. If the problem still persists, replace the system board. 7DEOH6\VWHP0HVVDJHV FRQWLQXHG 0HVVDJH &DXVH &RUUHFWLYH$FWLRQ

Codes and Messages

3-7 (PEHGGHG VHUYHU PDQDJHPHQW HUURU (PEHGGHG VHUYHU PDQDJHPHQWLV QRWSUHVHQW Embedded server management memory may be temporarily corrupted Shut down the system to clear the memory, and then restart the system. If the problem persists, disconnect all power cables from the system for at least one minute; then try again. *DWH$ IDLOXUH Faulty keyboard controller (defective system board) Replace the system board. *HQHUDO IDLOXUH Corrupted or improperly installed operating system Reinstall the operating system. +DUGGLVN GULYHUHDG IDLOXUH +DUGGLVN IDLOXUH Incorrect configura- tion settings in System Setup pro- gram, improperly connected hard-disk drive, faulty hard- disk drive controller subsystem (defec- tive system board), or loose power cable Check the primary and secondary SCSI configuration settings in the System Setup program. Reinstall the hard-disk drive. Check the interface cable and power cable connections to the backplane board. If the problem still persists, replace the system board. ,QYDOLG FRQILJXUDWLRQ LQIRUPDWLRQ SOHDVHUXQ 6(783SURJUDP Incorrect ISA_CLR jumper configura- tion, incorrect configuration set- tings in System Setup program, or faulty battery Remove the plug from the ISA_CLR jumper. Check the System Setup configuration settings. Replace the battery. ,QYDOLG&38 VSHHG GHWHFWHG FKHFNMXPSHUV Incorrect micro- processor jumper configuration Check the microproces- sor speed jumper. ,QYDOLG195$0 FRQILJXUD WLRQ UHVRXUFH UHDOORFDWHG Resource conflict detected and corrected when sys- tem resources were allocated using the RCU No action is required. 7DEOH6\VWHP0HVVDJHV FRQWLQXHG 0HVVDJH &DXVH &RUUHFWLYH$FWLRQ

Dell PowerEdge 4300 Systems Service Manual

,2SDULW\ LQWHUUXSWDW DGGUHVV Improperly installed or faulty expansion card Reinstall the expansion card(s). If the problem persists, replace the expansion card(s). .H\ERDUG FORFNOLQH IDLOXUH .H\ERDUG IDLOXUH Loose or improperly connected keyboard cable connector, defective keyboard, or defective keyboard/mouse controller (defective system board) Check the keyboard cable connection. Replace the keyboard. If the problem persists, replace the system board. .H\ERDUG FRQWUROOHU IDLOXUH Defective keyboard/ mouse controller (defective system board) Replace the system board. .H\ERDUGGDWD OLQHIDLOXUH .H\ERDUG VWXFNNH\ IDLOXUH Loose or improperly connected keyboard cable connector, defective keyboard, or defective keyboard/mouse controller (defective system board) Check the keyboard cable connection. Replace the keyboard. If the problem persists, replace the system board. 7DEOH6\VWHP0HVVDJHV FRQWLQXHG 0HVVDJH &DXVH &RUUHFWLYH$FWLRQ

Codes and Messages

3-9 0HPRU\ DGGUHVVOLQH IDLOXUHDW DGGUHVVUHDG YDOXHH[SHFW LQJYDOXH 0HPRU\GRXEOH ZRUGORJLF IDLOXUHDW DGGUHVVUHDG YDOXHH[SHFW LQJYDOXH 0HPRU\RGG HYHQORJLF IDLOXUHDW DGGUHVVUHDG YDOXHH[SHFW LQJYDOXH 0HPRU\ZULWH UHDGIDLOXUH DWDGGUHVV UHDGYDOXH H[SHFWLQJ YDOXH Faulty or improperly seated DIMM or defective system board Remove and reseat the DIMMs. If the problem persists, replace the DIMMs. If the problem still persists, replace the system board. 0HPRU\ DOORFDWLRQ HUURU Faulty application program Restart the application program. 0HPRU\ SDULW\LQWHU UXSWDW DGGUHVV Faulty or improperly seated DIMM Remove and reseat the DIMMs. If the problem persists, replace the DIMMs. 0HPRU\WHVWV WHUPLQDWHGE\ NH\VWURNH POST memory test terminated by pressing the spacebar No action is required. 1RERRW GHYLFH DYDLODEOH Faulty diskette, diskette/tape drive subsystem, hard-disk drive, or hard-disk drive sub- system, or no boot diskette in drive A Replace the diskette or hard-disk drive. If the problem persists, replace the system board. 7DEOH6\VWHP0HVVDJHV FRQWLQXHG 0HVVDJH &DXVH &RUUHFWLYH$FWLRQ

Dell PowerEdge 4300 Systems Service Manual

1RERRW VHFWRURQ KDUGGLVN GULYH Incorrect configura- tion settings in System Setup program or no operating system on hard-disk drive Check the hard-disk drive configuration settings in the System Setup program. 1RWLPHUWLFN LQWHUUXSW Defective system board Replace the system board. 1RQV\VWHP GLVNRUGLVN HUURU Faulty diskette, diskette/tape drive subsystem, or hard-disk drive subsystem Replace the diskette or hard-disk drive. If the problem persists, replace the system board. 1RWDERRW GLVNHWWH No operating sys- tem on diskette Use a bootable diskette. 1RWPRUHWKDQ 0%RI PHPRU\LV DOORZHGZLWK RQHSRZHU VXSSO\ Attempted to run system with more than 512 MB of memory and only one power supply Install a PSPB with addi- tional power supplies. 2QO\RQH PLFURSURFHV VRULV DOORZHGZLWK RQHSRZHU VXSSO\ Attempted to run two microproces- sors with one power supply Install a PSPB with addi- tional power supplies. 2QO\RQH5$,' FRQWUROOHULV DOORZHGZLWK RQHSRZHU VXSSO\ Attempted to run more than one RAID controller with one power supply Install a PSPB with addi- tional power supplies. 3OXJ 3OD\ &RQILJXUD WLRQHUURU Plug and Play or PCI resource configura- tion failure Reboot the system. If the problem persists, run the RCU to identify the resource conflict and then reallocate system resources accordingly. 7DEOH6\VWHP0HVVDJHV FRQWLQXHG 0HVVDJH &DXVH &RUUHFWLYH$FWLRQ

Codes and Messages

3-11 3URFHVVRURU WHUPLQDWRU FDUGQRW LQVWDOOHG No microprocessor or terminator card installed in one of the microprocessor guide bracket assemblies Ensure that each micro- processor guide bracket assembly has either a terminator card or a microprocessor installed. See Chapter 8, “Install- ing System Board Options,” in the sys- tem’s Installation and Troubleshooting Guide for instructions. 5HDGIDXOW 5HTXHVWHG VHFWRUQRW IRXQG Faulty diskette, diskette/tape drive subsystem, or hard-disk drive sub- system (defective system board) Replace the diskette or hard-disk drive. If the problem persists, replace the system board. 5HVHWIDLOHG Improperly con- nected diskette/tape drive, hard-disk drive, or power cable Check the diskette/tape drive interface cable and power cable connec- tions to the diskette drive. Replace the diskette/tape drive inter- face cable. Reinstall the hard-disk drive. Check the interface cable and power cable connec- tions to the backplane board. 520EDG FKHFNVXP  DGGUHVV Improperly installed or faulty expansion card Reinstall the expansion card(s). If the problem persists, replace the expansion card(s). 6HFWRUQRW IRXQG 6HHNHUURU Defective sectors on diskette or hard- disk drive Replace the diskette or hard-disk drive. 6HHNRSHUD WLRQIDLOHG Faulty diskette or hard-disk drive Replace the diskette or hard-disk drive. 6KXWGRZQ IDLOXUH Defective battery Replace the battery. 7LPHRIGD\ FORFNVWRSSHG Defective battery or faulty chip (defec- tive system board) Replace the battery. If the problem persists, replace the system board. 7DEOH6\VWHP0HVVDJHV FRQWLQXHG 0HVVDJH &DXVH &RUUHFWLYH$FWLRQ

Dell PowerEdge 4300 Systems Service Manual

7LPHRIGD\ QRWVHW Incorrect Time or Date settings or defective system battery Check the Time and Date settings. If the problem persists, replace the battery. 7LPHUFKLS FRXQWHU IDLOHG Defective system board Replace the system board. 8QH[SHFWHG LQWHUUXSWLQ SURWHFWHG PRGH Faulty or improperly seated DIMM or defective system board Remove and reseat the DIMMs. If the problem persists, replace the DIMMs. If the problem still persists, replace the system board. 8QVXSSRUWHG &38GHWHFWHG LQ6/27Q Microprocessor not supported by system Install a correct version of the microprocessor in the specified micro- processor connector. 8QVXSSRUWHG &38VSHHGLQ &026 Microprocessor not supported by BIOS Upgrade the BIOS. 8QVXSSRUWHG &38VSHHG SURFHVVRU PLVVLQJRU WHUPLQDWRU FDUG PLVVLQJ  6\VWHP KDOWHG Wrong microproces- sor speed; no microprocessor or terminator card installed in one or more of the microprocessor connectors Ensure that each micro- processor connector has either a terminator card or a microprocessor installed. Ensure only 100-MHz microproces- sors are used. :DUQLQJ )LUPZDUHLV RXWRIGDWH SOHDVHXSGDWH  Some portion of system firmware is out of date, possibly as result of power being removed from the system while servicing the bat- tery, PSPB, system board, or SCSI backplane Reflash the system firm- ware from the Dell Server Assistant CD (if available) or from the Dell Web site. :ULWHIDXOW :ULWHIDXOW RQVHOHFWHG GULYH Faulty diskette or hard-disk drive Replace the diskette or hard-disk drive. 7DEOH6\VWHP0HVVDJHV FRQWLQXHG 0HVVDJH &DXVH &RUUHFWLYH$FWLRQ

Codes and Messages

3-13 $OHUW0HVVDJHV)URP'HOO 2SHQ0DQDJH+,3 The Dell OpenManage HIP server-management application program generates alert messages that appear in the Simple Network Management Protocol (SNMP) trap log file. To see the trap log, select any enterprise under the SNMP trap log icon. Alert log messages consist of information, status, warning, and failure mes- sages for drive, temperature, fan, and power conditions. They can assist you with identifying a problem and may provide you with information to help you resolve the problem. Table 3-3 lists some of the alert log messages from the Dell OpenManage HIP application program. 7DEOH'HOO2SHQ0DQDJH+,3$OHUW/RJ0HVVDJHV 0HVVDJH &DXVH &RUUHFWLYH$FWLRQ $XWRPDWLF PDQDJHPHQW QRWLILFDWLRQ KDVRFFXUUHG The server stopped functioning and called the notification number specified in the DC Console Actions tab. The server will reboot if the Reset or Power Cycle option was selected in the Action on Hung Server Notifi- cation section of the System Console System tab. If nei- ther option was selected, the sys- tem can be reset using the Remote Management fea- ture in the Dell Remote Assistant Card utility. &KDVVLV LQWUXVLRQ GHWHFWHG The chassis of an attached system has been opened. Check to make sure the system chassis is closed. &XUUHQW VHQVRU GHWHFWHGD IDLOXUH The system power consumption is exceeding power supply capacity. The power supply name is provided. Verify that all of the expansion cards in the system are func- tioning properly. Verify that the load requirements of the hardware config- ured in the system do not exceed the capacity of the power supplies.

Dell PowerEdge 4300 Systems Service Manual

&XUUHQW VHQVRUZDUQ LQJGHWHFWHG The system power consumption is exceeding power supply capacity. The power supply name is provided. Verify that all of the expansion cards in the system are func- tioning properly. Verify that the load requirements of the hardware config- ured in the system do not exceed the capacity of the power supplies. (&&PHPRU\ IDXOW An ECC error has occurred in system memory. Run the appropriate memory test(s) from the Dell Diagnostics. )DQVHQVRU GHWHFWHGD IDLOXUH A failure of one or more fans was detected by the thermal-monitoring facility in the specified server. If possible, the chassis number and fan num- ber are provided. Check for a possible blockage of or in- adequate ventilation around the fan. If the fan is not blocked and ventilation is adequate, check fan connections. )DQVHQVRU ZDUQLQJ GHWHFWHG A fan sensor reading on the specified server has exceeded the user-settable warning thresholds. If possible, the chas- sis number and fan number are provided. Check for a possible blockage of or in- adequate ventilation around the fan. If the fan is not blocked and ventilation is adequate, check fan connections. 3RZHUVXSSO\ GHJUDGHG UHGXQGDQF\ GHWHFWHG In systems with optional redundant power supplies, a power supply has failed or a power utili- zation warning threshold has been exceeded. The sys- tem will function normally in this con- figuration and is still redundant. Check to see whether the power supply indicators show a power supply failure. Make sure that the latch switch on each power supply is enabled. Make certain that each connection to the power source is secure. Check the power utilization warning thresholds to verify that they are valid values. 7DEOH'HOO2SHQ0DQDJH+,3$OHUW/RJ0HVVDJHV FRQWLQXHG 0HVVDJH &DXVH &RUUHFWLYH$FWLRQ

Codes and Messages

3-15 3RZHUVXSSO\ GHWHFWHGD IDLOXUH In systems with optional redundant power supplies, the power supply sensor detected a failure in one of the power supplies. If possible, the power supply number is provided. Check to see whether the power supply indicators show a power sup- ply failure. Make sure that the latch switch on each power supply is enabled. Make cer- tain that each connection to the power source is secure. 3RZHUVXSSO\ ORVWUHGXQ GDQF\GHWHFWHG In systems with optional redundant power supplies, the system has detected that it has lost power supply redundancy. If one (or another) of the power supplies fails, the system will not be able to main- tain operation. This could be the result of a failed power sup- ply or too many adapters installed in the system. Check to see whether the power supply indicators show a power sup- ply failure. Make sure that the latch switch on each power supply is enabled. Make certain that each connection to the power source is secure. This could be a normal condi- tion because the default system configuration is nonredundant. The system will function normally in a nonredundant configuration. 7HPSHUDWXUH VHQVRU GHWHFWHGD IDLOXUH A temperature probe on the backplane board, system board, or drive carrier in the specified server has exceeded its temper- ature failure range. If possible, the chassis number and probe number are provided. Check for a fan fail- ure. If needed, replace the fan or fan assembly. 7DEOH'HOO2SHQ0DQDJH+,3$OHUW/RJ0HVVDJHV FRQWLQXHG 0HVVDJH &DXVH &RUUHFWLYH$FWLRQ

Dell PowerEdge 4300 Systems Service Manual

7HPSHUDWXUH VHQVRUZDUQLQJ GHWHFWHG A temperature probe on the backplane board, system board, or drive carrier in the specified server has exceeded its temper- ature warning range. If possible, the chas- sis number and probe number are provided. Make sure the fan thresholds are set in a reasonable range. Check for a fan fail- ure. Make sure the computer cover is properly installed. 9ROWDJHVHQ VRUGHWHFWHGD IDLOXUH A failure has occurred with the system power supply or voltage probe(s) on the system board. If possible, the chas- sis number and probe number are provided. Check the power supply and back- plane board connections. 9ROWDJHVHQ VRUZDUQLQJ GHWHFWHG The voltage probe on the backplane board, system board, or power supply for the specified server has exceeded its warn- ing range. If possible, the chassis number and probe number are provided. Make sure the user- settable voltage thresholds are set correctly. If the prob- lem persists, check the power supply and backplane board connections. 7DEOH'HOO2SHQ0DQDJH+,3$OHUW/RJ0HVVDJHV FRQWLQXHG 0HVVDJH &DXVH &RUUHFWLYH$FWLRQ

Codes and Messages

3-17 6&6,+DUG'LVN'ULYH,QGLFDWRU&RGHV Three indicator lights in each SCSI hard-disk drive carrier provide information on the status of the SCSI hard-disk drives (see Figure 3-1). The SCSI backplane firmware controls the drive online and drive failure indicators. )LJXUH+DUG'LVN'ULYH,QGLFDWRUV Table 3-4 lists the drive indicator patterns established by the SCSI backplane firmware. Different patterns are displayed as drive events occur in the system. For example, in the event of a hard-disk drive failure, the drive failed pattern appears. After the drive is selected for removal, the drive being prepared for removal pattern appears, followed by the drive ready for insertion or removal pattern. After the replacement drive is installed, the drive being prepared for operation pattern appears, followed by the drive online pattern. NOTE: If you do not have a Dell PowerEdge Expandable RAID Controller host adapter card installed, you will see only the drive online and drive bay empty indicator patterns. hard-disk drive activity indicator hard-disk drive online indicator hard-disk drive failure indicator

Dell PowerEdge 4300 Systems Service Manual

7DEOH6&6,+DUG'LVN'ULYH,QGLFDWRU3DWWHUQV &RQGLWLRQ ,QGLFDWRU3DWWHUQ Identify drive All three drive status indicators blink simultaneously. Drive being prepared for removal The three drive status indicators flash sequentially. Drive ready for insertion or removal All three drive status indicators are off. Drive being prepared for operation The drive online indicator is on. The drive activity light may flash briefly. Drive bay empty All three drive status indicators are off. Drive predicted failure The drive online indicator is on. The drive failure indicator blinks on briefly each second. Drive failed The drive online indicator turns off. The drive failure indicator blinks off briefly each second. Drive rebuilding The drive online indicator blinks rapidly. Drive online The drive online indicator is on.

Removing and Replacing Parts

4-1 & + $ 3 7 ( 5    5HPRYLQJDQG5HSODFLQJ3DUWV This chapter provides procedures for removing the components, assemblies, and subassemblies in the computer. Unless otherwise noted, each procedure is based on the following assumptions: ‡ You have performed the steps in “Precautionary Measures” found later in this chapter. ‡ You have removed the computer cover and/or front bezel as necessary. ‡ You can replace or reinstall a part by performing the removal procedure in reverse order unless additional information is provided. :$51,1*7KHSRZHUVXSSOLHVLQWKLVFRPSXWHUV\VWHPSURGXFHKLJK YROWDJHVDQGHQHUJ\KD]DUGVZKLFKFDQFDXVHERGLO\KDUP2QO\ WUDLQHGVHUYLFHWHFKQLFLDQVDUHDXWKRUL]HGWRUHPRYHWKHFRPSXWHU FRYHUDQGDFFHVVDQ\RIWKHFRPSRQHQWVLQVLGHWKHFRPSXWHU 5HFRPPHQGHG7RROV The PowerEdge 4300 has been designed for greater manual serviceability. Removing and replacing hard-disk drives in the external drive bay insert requires a small flat-blade screwdriver. The remaining procedures do not require the use of tools. Also, use a wrist grounding strap as explained in the next section, “Pre- cautionary Measures.”

Dell PowerEdge 4300 Systems Service Manual

3UHFDXWLRQDU\0HDVXUHV Before you perform any of the procedures in this chapter, take a few moments to read the following warning for your personal safety and to prevent damage to the computer system from ESD. :$51,1*)25<2853(5621$/6$)(7<$1'3527(&7,212)7+( (48,30(17 Before you start to work on the computer, perform the following steps in the sequence listed: 1. Turn off the computer and any attached peripherals. 2. Disconnect the computer and any attached peripherals from their power sources to reduce the potential for personal injury. 3. Disconnect any communications cables. 4. Wear a wrist grounding strap, and clip it to any unpainted metal sur- face on the computer chassis. If a wrist grounding strap is not available, touch any unpainted metal surface on the back of the computer chassis to discharge any static charge from your body.

Removing and Replacing Parts

4-3 &RPSXWHU&RYHU )LJXUH&RPSXWHU&RYHU5HPRYDO To remove the computer cover, follow these steps: 1. Turn the keylock on the back edge of the cover clockwise to the unlocked position (see Figure 4-1). 2. Slide the cover a half-inch (about a centimeter) or so toward the back of the computer, and grasp the top of the cover at both ends. 3. Lift the cover away from the chassis. To replace the cover, make sure the keylock is in the unlocked position. Fit the cover over the side rail at the bottom of the chassis and slide it closed. computer cover keylock

Dell PowerEdge 4300 Systems Service Manual

)URQW%H]HO )LJXUH)URQW%H]HO5HPRYDO To remove the front bezel, follow these steps: 1. Remove the computer cover. 2. With your fingertips, gently pry loose the four tabs along the right edge of the bezel, and disengage the three clips on the opposite edge from the chassis (see Figure 4-2). 3. Rotate the bezel to the left to disengage it. To replace the bezel, align the three clips on the edge of the bezel with the slots on the chassis and press the bezel into place until the tabs on the oppo- site edge of the bezel snap into place. clips (3) tabs (4) front bezel

Removing and Replacing Parts

4-5 &RQWURO3DQHO$VVHPEO\ )LJXUH&RQWURO3DQHO$VVHPEO\5HPRYDO To remove the control panel assembly, follow these steps: 1. Disconnect the ribbon cable from its connector on the left side of the con- trol panel assembly (see Figure 4-3). 2. Loosen the thumbscrew securing the control panel assembly to the front of the chassis. 3. Slide the control panel assembly to the right (or up if system is in rack- mount position) to disengage the assembly from the chassis hooks. NOTE: The ribbon cable that attaches to the control panel assembly connects to the PLANAR connector on the SCSI backplane and then continues on to the BACKPLANE connector on the system board. ribbon cable thumbscrew control panel

Dell PowerEdge 4300 Systems Service Manual

'ULYHV Figure 4-4 shows an example of drive hardware that can be installed in the computer. Refer to this figure when you perform any of the procedures in the following subsections. )LJXUH'ULYH+DUGZDUH diskette-drive interface connector (FLOPPY) Ultra/Narrow SCSI host adapter connector (SECONDARY SCSI) SCSI CD-ROM drive diskette drive DC power cable diskette-drive interface cable Ultra/Narrow SCSI cable

Removing and Replacing Parts

4-7 ([WHUQDOO\$FFHVVLEOH'ULYHV The chassis provides three bays for 5.25-inch externally accessible drives and a bay dedicated to a 3.5-inch diskette drive. )URQW3DQHO,QVHUWV )LJXUH)URQW3DQHO,QVHUWV To remove the front-panel insert that covers an unused bay (see Figure 4-5), first remove the front bezel. Then, facing the inside of the front bezel, press one of the securing tabs (located at each end of the bezel) while pressing against the center of the insert until it springs free from the bezel. To replace a front-panel insert, from inside the chassis place the insert into the bay opening and press it into place until the tabs on each end of the insert snap into the latches on the inside of the bezel. &ORVH2XW3DQHOV Metal close-out panels that fit into the drive-bay openings in the chassis pro- vide extra EMI shielding if you are not using the plastic front-panel inserts. The close-out panel for a 1.6-inch bay has a raised lip at the bottom that overlaps the top of a panel beneath it, if any. Because of the overlap, if two or more 1.6-inch close-out panels are installed, you must remove them from the top down. The close-out panel for the 1-inch diskette-drive bay (the top bay in either chassis orientation) is narrower and has no overlap lip. front-panel inserts

Dell PowerEdge 4300 Systems Service Manual

To remove a close-out panel, pry the bottom of the panel outward at the center until you can unhook a securing tab at one end and work out the other end. When installing close-out panels, install 1.6-inch panels from the bottom up. Make sure the overlap lip is at the bottom and projecting toward you. Insert the tab on one side of the panel into the appropriate slot in the drive cage, bow the panel slightly, and fit the second tab into the slot in the other side of the cage. Make sure the sides of the panel fit flush against the sides of the drive cage. 5HRULHQWLQJWKH([WHUQDO'ULYH&DJH To accommodate a change in computer orientation (for example, from an upright to a rack configuration), you can reconfigure the external drive bays to remain horizontal as follows: 1. Remove the front-panel inserts from the front bezel. 2. Reposition the plastic frame surrounding the drive opening in the front bezel: a. Facing the inside of the front bezel, press against the center of the frame with your thumbs until the frame bows sufficiently to loosen the tabs on the sides of the insert. Pull the frame out of the bezel. b. Rotate the frame 90 degrees to match the new orientation of the drives. c. Replace the frame in the front bezel and carefully press it into place. 3. Reinstall the front-panel inserts to match the new drive orientation. 4. Remove the computer cover and slide the system board tray out to the ser- vice position. 5. Remove the external drives from the drive bays (noting all cable connec- tions); remove any metal inserts covering empty drive bays. 6. Reinstall the external drives to match the new system orientation, and reconnect cables as appropriate. 7. Close the system board tray. 8. Replace the front bezel and computer cover.

Removing and Replacing Parts

4-9 DQG,QFK'ULYHV )LJXUH([WHUQDOO\$FFHVVLEOH'ULYH5HPRYDO To remove a 3.5-inch or 5.25-inch drive assembly from one of the externally accessible drive bays, follow these steps: 1. Press the two drive release tabs toward the center of the drive, and slide the drive out the front of the bay (see Figure 4-6). 2. Disconnect the DC power cable and the interface cable from the back of the drive. Be sure to record the power connector number and the location of the interface cable connector. drive release tabs (2)

Dell PowerEdge 4300 Systems Service Manual

3. Remove the drive-mounting rails from the drive (see Figure 4-7). )LJXUH'ULYH0RXQWLQJ5DLO5HPRYDO ([DPSOH 4. If the drive is a SCSI drive, record the setting of the SCSI address jumpers and SCSI bus termination jumper. 5. If the drive is a SCSI drive, remove the 50-pin-to-68-pin adapter from the SCSI connector on the back of the drive (if present). Some drives use a 50-pin-to-68-pin adapter between the SCSI cable and the drive connector. Check the back of the drive for an adapter; if one is present, remove it and retain it for use on the new drive. NOTES: When you install a drive, install the drive rails and slide the drive into its bay until the rails snap securely into place. When you reinstall a SCSI drive, set the SCSI address jumpers and the SCSI bus termination jumpers to the settings you recorded when you removed the drive. drive release tabs (2) drive-mounting rails (2) screws (4) drive-mounting rails (2) screws (6) drive release tabs (2)

Removing and Replacing Parts

4-11 +DUG'LVN'ULYHVLQ([WHUQDO%D\ )LJXUH+DUG'LVN'ULYHVLQ([WHUQDO%D\ Two SCSI hard-disk drives can be installed in the external bay using the exter- nal drive-bay insert (see Figure 4-8). Drives mate to a small backplane board on the back of the insert; from there, they can be connected via a two-device rib- bon cable either to a RAID controller or to the Ultra2/LVD SCSI connector on the system board. &$87,21+RWSOXJJDEOHGULYHLQVWDOODWLRQDQGUHPRYDOLVQRWVXS SRUWHGIRUKDUGGLVNGULYHVLQVWDOOHGLQWKHH[WHUQDOGULYHED\ 5HPRYLQJDGULYHZKLOHWKHV\VWHPLVWXUQHGRQZLOOUHVXOWLQDORVV RIGDWD Remove a SCSI hard-disk drive from the external drive bay as follows: 1. Press inward on the two release tabs on the drive bay insert, and pull the insert about one inch out of the external bay. 2. Use a flat-blade screwdriver to remove the screw that secures the locking bar on the front of the insert, and remove the locking bar. 3. Open the drive carrier handle to release the carrier, and slide the carrier toward you and out of the insert. When installing a drive in the insert, slide the drive in with the handle open until it stops, and then push the handle closed and slide the drive in the rest of the way. Replace the locking bar before installing the insert into the chassis. If you are not replacing the drive, install a metal close-out panel on the front of the external bay or a front-panel insert on the front bezel. drive in drive carrier drive-carrier locking bar drive carrier handle external drive-bay insert release tabs (2) flat-head screw

Dell PowerEdge 4300 Systems Service Manual

+DUG'LVN'ULYHV )LJXUH+DUG'LVN'ULYH5HPRYDO Remove a SCSI hard-disk drive from an internal drive bay as follows. &$87,21+RWSOXJJDEOHGULYHLQVWDOODWLRQDQGUHPRYDOLVQRW VXSSRUWHGIRUV\VWHPVZLWKRXWD'HOO3RZHU(GJH([SDQGDEOH5$,'&RQWURO OHUKRVWDGDSWHUFDUG5HPRYLQJDGULYHZLWKRXWWXUQLQJWKHV\VWHPRIILQ WKLVVLWXDWLRQZLOOUHVXOWLQDORVVRIGDWD 1. If the system does not have a PowerEdge Expandable RAID Controller card installed, shut down the system and go to step 3. 2. For systems with a PowerEdge Expandable RAID Controller card, refer to the RAID controller documentation for information on preparing the drive for removal. When the drive has been powered down, wait until the drive status indicators adjacent to the drive bay signal that the drive may be removed safely. If the drive has been online, the drive status indicators flash sequentially as the drive is powered down. When all indicators are turned off, the drive is ready for removal. 3. Unlock the hard-disk drive keylock (see Figure 4-9). 4. Squeeze the open side of the drive carrier handle to release it, open the handle, and slide the carrier toward you until it is free of the drive bay. drive carrier drive-carrier handle hard-disk drive keylock

Removing and Replacing Parts

4-13 5. Remove the drive from its carrier by removing the four screws (two on each side) that secure it in the carrier. Before installing a new drive, set all jumpers and remove termination from the drive. When installing the drive, raise the carrier handle until it latches to ensure that the drive is fully seated in the backplane board.

Dell PowerEdge 4300 Systems Service Manual

6&6,%DFNSODQH%RDUG )LJXUH6&6,%DFNSODQH%RDUG5HPRYDO To remove a SCSI backplane board, follow these steps: 1. Slide the system board tray out to the service position. See “Accessing the Interior of the System” in Chapter 1 for instructions. 2. Remove the hard-disk drives. 3. Disconnect all cables from the SCSI backplane board, noting where the cables are connected. 4. Loosen the thumbscrew on the backplane board (see Figure 4-10). 5. Slide the backplane board away from the power-supply paralleling board (PSPB) about a quarter inch, and lift it off the L-shaped mounting tabs on the hard-disk drive cage. thumbscrew SCSI backplane board

Removing and Replacing Parts

4-15 &$87,21,I\RXUHPRYHSRZHUIURPWKH6&6,EDFNSODQHERDUG HLWKHUE\UHPRYLQJWKHSRZHUFDEOHRUGXULQJUHSODFHPHQWRIWKH V\VWHPERDUGEDWWHU\ \RXPD\QHHGWRUHIODVKWKHV\VWHP·V ILUPZDUH 7KHRULJLQDOILUPZDUHRQWKH6&6,EDFNSODQHLVVWRUHGLQ((3520 +RZHYHULIWKH6&6,EDFNSODQHILUPZDUHLVHYHUXSGDWHGWKHXSGDWH LVVWRUHGLQYRODWLOH5$0,ISRZHULVUHPRYHGIURPDQXSGDWHGEDFN SODQHERDUGWKHXSGDWHLVORVWDQGWKHERDUGUHYHUWVWRLWVRULJLQDO ILUPZDUHLQ((3520 ,IDWV\VWHPVWDUWXS\RXUHFHLYHWKHPHVVDJH:DUQLQJ)LUPZDUH LV RXWRIGDWH, SOHDVHXSGDWH'HOOUHFRPPHQGVWKDW\RX UHIODVKDOOV\VWHPILUPZDUHIURPWKH'HOO6HUYHU$VVLVWDQW&' 

Dell PowerEdge 4300 Systems Service Manual

6\VWHP3RZHU6XSSO\ )LJXUH3RZHU6XSSO\5HPRYDO :$51,1*)RUV\VWHPVZLWKQRQUHGXQGDQWSRZHUVXSSOLHVWXUQRII SRZHUWRWKHV\VWHPEHIRUHUHPRYLQJWKHV\VWHPSRZHUVXSSOLHV To remove a power supply, follow these steps: 1. Disconnect the AC power cable from the electrical outlet, and then dis- connect the other end of the cable from the power supply. 2. Press the locking bar in the power supply handle to the left (or up if the sys- tem is in the rack-mount position) until the latch disengages from the chassis (see Figure 4-11). 3. Rotate the handle outward (forcing the power supply partially out of its bay) and pull the power supply the rest of the way out by the handle. When installing a power supply, make sure the handle is all the way out (at a right angle to the back of the power supply). Slide the power supply almost all the way into its bay, letting it extend out about a quarter of an inch. Rotate the handle back toward the power supply while fitting the two legs of the handle into the cutouts in the chassis wall and, at the same time, pressing the power supply the rest of the way into the bay. Then push the locking bar to the right (or down if the system is in the rack-mount position) until the latch snaps into place, securing the power supply. &$87,217KHSRZHUVXSSO\ZLOOQRWRSHUDWHXQOHVVWKHKDQGOHLV VQDSSHGDOOWKHZD\LQWRWKHORFNHGSRVLWLRQ cutouts (2) handle locking bar latch legs (2)

Removing and Replacing Parts

4-17 6\VWHP3RZHU6XSSO\DQG363%8SJUDGH )LJXUH3RZHU&DEOH&RQQHFWLRQV³6LQJOH3RZHU6XSSO\ :$51,1*)RUV\VWHPVZLWKQRQUHGXQGDQWSRZHUVXSSOLHVWXUQRII SRZHUWRWKHV\VWHPEHIRUHUHPRYLQJWKHV\VWHPSRZHUVXSSOLHV If you have a single power-supply configuration (when available as an option) for your Dell PowerEdge 4300 system, follow these steps to upgrade a com- puter with a PSPB and additional power supplies: 1. Remove the power supply. 2. Slide the system board tray out of the chassis to the service position. See “Accessing the Interior of the System” in Chapter 1 for instructions. 3. Disconnect the power cable harness from the POWER connector on the SCSI backplane board, from the PWR1 and PWR2 connectors on the sys- tem board, and from the diskette drive and other drives in the external drive bay (see Figure 4-12). When disconnecting the cables from the SCSI backplane board and the system board, press the plastic latch on one side of the connector to release it. power cables to external drives (2) system-board power cable connector (PWR1) SCSI backplane-board power cable connector (POWER) system-board power cable connector (PWR2)

Dell PowerEdge 4300 Systems Service Manual

4. Remove the screw securing the PSPB tray to the chassis (see Figure 4-13). )LJXUH363%7UD\/RFDWLRQLQWKH6\VWHP&KDVVLV 5. Remove the PSPB tray from the chassis. If necessary, temporarily disconnect the SCSI interface cables from the system board to allow removal of the tray. 6. Remove the power cable harness from the PSPB tray by compressing the two retention tabs on both of the connector-mounting posts. 7. Install the three Y-cables in the PSPB tray. To install a cable, insert the connector through the opening in the PSPB tray until the retention tabs on the mounting posts lock the connector into place. 8. Install the PSPB on the PSPB tray as follows (see Figure 4-14): a. While holding the PSPB by its edges, position the PSPB so that the tabs on the PSPB tray fit through the corresponding slots in the PSPB. b. Slide the PSPB toward the front of the tray a quarter of an inch (about one centimeter). c. Secure the PSPB by tightening the captive screw. PSPB tray screw

Removing and Replacing Parts

4-19 )LJXUH363%,QVWDOODWLRQRQWKH363%7UD\ 9. Connect the three Y-cables to the corresponding three pairs of connectors on the PSPB. 10. Reinstall the PSPB tray in the chassis. Secure the tray with the screw you removed in step 4. PSPB PSPB tray captive screw

Dell PowerEdge 4300 Systems Service Manual

11. Attach the four-conductor power cable to the external-drive power cable connector (labeled “FD”) on the PSPB (see Figure 1-7), and to the drives in the external drive bays (see Figure 4-15). )LJXUH3RZHU&DEOH&RQQHFWLRQV³0XOWLSOH3RZHU6XSSOLHV 12. Attach the nine-conductor power cable labeled “HDBP” to the SCSI backplane-board power cable connector (HD_B/P) on the PSPB and to the power connector (POWER) on the SCSI backplane board (see Figure 1-7 and Figure 4-15). 13. Attach the system-board power cable connectors labeled “PWR1” and “PWR2” to the corresponding connectors on the PSPB and system board (see Figure 1-7 and Figure 4-15). 14. If you disconnected any SCSI interface cables in step 5, connect those cables to the system board. 15. Slide the system board tray back into the chassis. 16. Reinstall the primary power supply. 17. Install the additional power supply or supplies. power cables to external drives system-board power cable connector (PWR1) power cable connector (POWER) system-board power cable connector (PWR2) SCSI backplane-board power cable connector (HD_B/P)

Removing and Replacing Parts

4-21 3RZHU6XSSO\3DUDOOHOLQJ%RDUG )LJXUH3RZHU6XSSO\3DUDOOHOLQJ%RDUG5HPRYD O Remove the PSPB as follows: 1. Slide the system board tray out to the service position. See “Accessing the Interior of the System” in Chapter 1 for instructions. 2. Disconnect all power harnesses and cables from the PSPB. 3. Loosen the captive screw securing the PSPB to the chassis wall (see Figure 4-16). 4. Slide the PSPB toward the power supplies about a quarter of an inch until it disengages from the hooked tabs in the chassis wall, and lift it out. When installing a replacement PSPB, position the PSPB against the chassis wall so that the tabs on the chassis wall fit through the corresponding slots in the PSPB, slide the PSPB toward the front of the chassis until it is firmly engaged in the tabs, and tighten the screw. When replacing the power harnesses and cables, refer to “PSPB and System Power Supplies” in Chapter 1 for cable routing information. PSPB screw

Dell PowerEdge 4300 Systems Service Manual

6\VWHP&RROLQJ)DQV )LJXUH6\VWHP&RROLQJ)DQV Five cooling fans are installed in the Dell PowerEdge 4300 chassis. The drive fan assembly consists of three fans mounted in a carrier above the hard-disk drive enclosure; the system-board fan assembly consists of two fans mounted in a carrier on the inner wall of the system board tray (see Figure 4-17). The drive fan assembly is hot-pluggable and must be replaced as a unit. The sys- tem board fans are individually hot-pluggable. hard-disk drive fan assembly system board fans (2)

Removing and Replacing Parts

4-23 7KUHH)DQ$VVHPEO\ )LJXUH7KUHH)DQ$VVHPEO\5HPRYDO The drive fan assembly is hot-pluggable and can be quickly replaced while the system is running. :$51,1*,IUHSODFLQJWKLVDVVHPEO\ZKLOHWKHV\VWHPLVUXQQLQJ PDNHVXUH\RXKDYHWKHQHZDVVHPEO\KDQG\DQGSHUIRUPWKHSUR FHGXUHTXLFNO\WRDYRLGRYHUKHDWLQJWKHGULYHV Follow these steps to remove a drive fan assembly: 1. If replacing the drive fan assembly while the system is running, have the new fan assembly ready. 2. Lift up on the release latch on the back of the three-fan assembly (see Fig- ure 4-18) and slide the assembly out of the system. 3. Slide the replacement assembly into the system, making sure that the electrical connector is fully seated. The cooling fans should be operating. cooling fans (3) release latch fan assembly connector

Dell PowerEdge 4300 Systems Service Manual

)DQ3RZHU&DEOH%XQGOH NOTE: This is not a hot-pluggable procedure. To remove the power cable bundle that mates to the bottom of the drive fan assembly, follow these steps: 1. Remove the drive fan assembly. 2. Squeeze the ends of the power-cable bundle connector while pulling the cable (from the connector) out from under the metal support bracket. 3. Disconnect the other end of the cable from the FAN connector on the SCSI backplane. 'ULYH)DQ )LJXUH'ULYH)DQ5HPRYDO NOTE: This is not a hot-pluggable procedure. To replace a faulty fan in a drive fan assembly before storing the assembly for future use, follow these steps: 1. Remove the faulty fan from the fan carrier by releasing the two retention tabs that secure the fan in the carrier (see Figure 4-19) and working the fan out of the carrier. 2. Remove the fan’s power cable from the carrier’s power harness bundle. 3. Use the push fasteners that came with the new fan to install the metal fin- ger guard on the fan. Install the guard so that the fan’s airflow arrow points toward the guard. 4. Connect the new fan’s cable to the carrier’s power harness bundle. 5. Insert the new fan into the carrier under the two retention tabs. retention tabs (2)

Removing and Replacing Parts

4-25 6\VWHP%RDUG)DQV )LJXUH6\VWHP%RDUG)DQ5HPRYDO The system board fans are hot-pluggable and can be quickly replaced while the system is running. :$51,1*,IUHSODFLQJWKLVDVVHPEO\ZKLOHWKHV\VWHPLVUXQQLQJ PDNHVXUH\RXKDYHWKHQHZIDQDVVHPEOHGDQGKDQG\DQGSHUIRUP WKHSURFHGXUHTXLFNO\WRDYRLGRYHUKHDWLQJWKHPLFURSURFHVVRU V  1. Assemble the new fan. Use the push fasteners that came with the new fan to install the finger guard on the fan. Install the guard so that the fan’s airflow arrow points away from the guard. 2. Slide the system board tray out to the service position. See “Accessing the Interior of the System” in Chapter 1 for instructions. 3. On the fan to be replaced, disconnect the cable from the extension cable attached to the appropriate fan connector (FAN1 or FAN2) on the system board. 4. Pull outward on the fan-retention tabs to disengage the fan (see Fig- ure 4-20). To install the new fan, slide the fan into the fan housing, align the holes in the corners of the fan with the studs in the housing, and snap the fan into place. Connect the fan to the appropriate extension cable. retention tabs (2)

Dell PowerEdge 4300 Systems Service Manual

6\VWHP%RDUG&RPSRQHQWV The subsections that follow contain procedures for removing system board components. Refer to Figure 4-21 for the location of components. )LJXUH6\VWHP%RDUG&RPSRQHQWV  video connector (JVGA) parallel port connector (PARALLEL) serial port connectors (2) (SERIAL1 [top] and SERIAL2) keyboard and mouse connectors (KYBD/MOUSE) diskette-drive interface connector (FLOPPY) secondary microprocessor (PROCESSOR 2) battery connector (BATTERY) Ultra/Narrow SCSI connector (SCSI2) DIMM sockets (DIMM_A [right]–DIMM_D) speed and configuration jumpers fan connectors (FAN1, FAN2) front of system board primary microprocessor (PROCESSOR 1) ISA connectors (ISA5 [top] and ISA6) primary PCI connectors (PCI1 [top] through PCI4) power input connector (POWER1) secondary PCI connectors (PCI5 [top] and PCI6) Ultra2/LVD SCSI connector (SCSI1) chassis-intrusion switch connector (INTRUS2) SCSI backplane board interface connector (BACKPLANE) server management bus connector (XSMB_IN) server management bus connector (XSMB_OUT) Dell Remote Assistant Card connector (SVR_MGT) hard-disk drive activity indicator connector (HLED) storage-system server-management bus connector (SDS_SMB) power input connector (POWER2) system-board power indicator (STANDBY_LED)

Removing and Replacing Parts

4-27 ([SDQVLRQ&DUGV )LJXUH([SDQVLRQ&DUG$FFHVV'RRU To remove an expansion card, follow these steps: 1. Unlock the keylock, remove the key, and then turn the keylock to the access-door release position (see Figure 4-22). 2. Squeeze the dual latches on the expansion-card access door to open the door, exposing the expansion-card compartment. 3. Record the location of any cables attached to the expansion card you want to remove, and then disconnect the cables. &$87,21'RQRWXVHDWRROWRIRUFHRSHQWKHUHOHDVHWDELQWKHPLG GOHRIWKHH[SDQVLRQFDUGODWFK keylock in access-door release position latches (2)

Dell PowerEdge 4300 Systems Service Manual

4. For the card you want to remove, press in and hold the clip on the back of the computer. At the same time, from inside the computer, press the curved release tab in the middle of the expansion-card latch toward the bottom of the card. After the release tab clicks into the latch cutout, rotate the latch away from the expansion-card bracket (see Figure 4-23). )LJXUH([SDQVLRQ&DUG5HPRYDO 5. Release the inner end of the expansion card by pressing outward on the latch at the inner corner of the card. 6. Grasp the expansion card by its corners and carefully remove it from the expansion-card connector. To install an expansion card, insert the card firmly into its connector and make sure the securing clips on both ends of the card (when applicable) are in place. Secure the clip on the back of the computer by pressing firmly inward until the release lever on the inside clicks into place. expansion card release tab expansion- card latch PCI access door

Removing and Replacing Parts

4-29 ,QWHULRU6XSSRUW3DQHO )LJXUH,QWHULRU6XSSRUW3DQHO5HPRYDO To access the microprocessors or the memory module, you must remove the interior support panel as follows: 1. Loosen the thumbscrews on the left side of the panel (see Figure 4-24). 2. Rotate the panel outward slightly, and lift the hinge side of the panel to clear the tabs from the hinge slot. screws (2) support panel

Dell PowerEdge 4300 Systems Service Manual

',00V )LJXUH',005HPRYDO To remove a DIMM, follow these steps: 1. Remove the interior support panel. 2. Press outward on the socket’s securing clips until the DIMM is released from the socket (see Figure 4-25). Then, lift the DIMM away from the socket. To replace a DIMM, press outward on the securing clips until they snap open (see step 1 in Figure 4-26). Align the notches in the DIMM to the crossbars in the socket, and press down on the outer edges of the DIMM while pulling up on the securing clips until the clips lock around the ends of the DIMM (see step 2 in Figure 4-26). )LJXUH',00,QVWDOODWLRQ securing clips notches 1. 2. securing clips

Removing and Replacing Parts

4-31 6(&&DUWULGJHDQG+HDW6LQN$VVHPEO\ )LJXUH6(&&DUWULGJH5HOHDVH/DWFKHV To remove an SEC cartridge and heat sink assembly, follow these steps. :$51,1*7KH6(&FDUWULGJHDQGKHDWVLQNDVVHPEO\FDQJHW H[WUHPHO\KRWGXULQJV\VWHPRSHUDWLRQV%HVXUHWKDWLWKDVKDG VXIILFLHQWWLPHWRFRROEHIRUHWRXFKLQJLW :$51,1*:KHQKDQGOLQJWKH6(&FDUWULGJHDQGKHDWVLQNDVVHP EO\WDNHFDUHWRDYRLGVKDUSHGJHVRQWKHKHDWVLQN 1. On the unit to be removed, press inward on the two SEC cartridge release latches until they snap into the open position (see Figure 4-27). release latches (2)

Dell PowerEdge 4300 Systems Service Manual

2. Remove the two retention pins from the SEC cartridge and heat sink assembly (see Figure 4-28).  )LJXUH6(&&DUWULGJHDQG+HDW6LQN5HPRYDO 3. Pull the SEC cartridge straight up out of the connector and guide bracket assembly (some force may be required). To replace an SEC cartridge, make sure the cartridge release latches are in the open position, orient the new SEC cartridge in the guide bracket assembly (as shown in Figure 4-28) and seat it firmly, and then snap the release latches back into place. Reinstall the two retention pins. To install an SEC cartridge where there was none before, you will need to remove the installed terminator card (see the next subsection, “Terminator Card”). NOTE: Do not attempt to operate the system with the microprocessor set to a speed other than the specified rating.  SEC cartridge release latches (2) heat sink SEC cartridge retention pins (2) guide bracket assembly

Removing and Replacing Parts

4-33 7HUPLQDWRU&DUG )LJXUH7HUPLQDWRU&DUG5HPRYDO To remove a terminator card, follow these steps: 1. Remove the retaining clip from the guide bracket assembly. Using the thumb and forefinger of each hand, pinch the tabs at each end of the clip (see Figure 4-29), and then lift the clip straight up. 2. Remove the terminator card. Hold the card by its edges, and lift the card straight up from the guide bracket assembly. terminator card guide bracket assembly notch retaining clip tabs (2)

Dell PowerEdge 4300 Systems Service Manual

6\VWHP%DWWHU\ )LJXUH6\VWHP%DWWHU\5HPRYDO To remove the system battery, follow these steps: 1. Before turning off the system, enter the System Setup program if possible and make a printed copy of the System Setup screens (see Appendix A). 2. Remove any expansion cards that block access to the battery. 3. Remove the battery (see Figure 4-30) by prying it out of its socket with your fingers or with a blunt, nonconducting object, such as a plastic screwdriver. To replace the system battery, orient the new battery with the “+” facing up. Insert the battery into its socket and snap it into place. When prompted during the boot routine, press to enter the System Setup pro- gram and compare the system configuration information with the copy of the system configuration settings you made in step 1. Restore any system configuration information that was lost while the battery was being replaced. NOTE: As a result of the power loss while replacing the battery, you may lose portions of the current system firmware. If, after replacing the system battery, you receive the message :DUQLQJ)LUPZDUHLVRXWRIGDWH SOHDVHXSGDWH, reflash the system firmware from the Dell Server Assis- tant CD (if available) or download it from the Dell Web site at www.dell.com. :$51,1* 7KHUH LV D GDQJHU RI WKH QHZ EDWWHU\ H[SORGLQJ LI LQFRUUHFWO\ LQVWDOOHG 5HSODFH WKH EDWWHU\ RQO\ ZLWK WKH VDPH RU HTXLYDOHQW W\SH UHFRPPHQGHG E\ WKH PDQXIDFWXUHU 'LVFDUG XVHG EDWWHULHV DFFRUGLQJWRWKHPDQXIDFWXUHU·VLQVWUXFWLRQV BATTERY socket battery

Removing and Replacing Parts

4-35 6\VWHP%RDUG$VVHPEO\ )LJXUH6\VWHP%RDUG$VVHPEO\5HPRYDO The system board assembly consists of the system board and a mounting plate. The system board is held to the mounting plate with screws and mount- ing clips. To remove the system board assembly, follow these steps: 1. Disconnect all cables from the system board. Be sure to record where each cable is attached. 2. To remove the system board tray, first release the tray latch at the lower- back corner of the tray (see Figure 4-31) and pull the tray open to the service position. Then depress the latch again and pull the tray out of the chassis. system board tray tray latch

Dell PowerEdge 4300 Systems Service Manual

6\VWHP%RDUG )LJXUH6\VWHP%RDUG5HPRYDO To remove the system board from the system board tray, perform the following steps. (If you are replacing the system board, you may want to remove the expansion cards, memory, processors, and processor guidesand install them on the replacement system board.) 1. Remove the system board assembly. 2. Note the slot numbers of any expansion cards you are migrating to the new system board so that you can install them in the same slots on the new board. 3. Remove the system board components you are migrating to the new sys- tem board. 4. Loosen the thumbscrew securing the system board to the tray (see Figure 4-32). 5. Slide the system board to the left as shown in Figure 4-32 (toward the inner expansion-card guide brackets) about a half inch to clear the chassis hooks, and remove the board. If you are replacing the system board, install any components you removed from the old system board onto the replacement board. To retain the same system configuration and appropriate resource sharing, install PCI expansion cards in the same slots they were in on the old system board. Verify that the jumper settings on the new system board are correct. thumbscrew inner card-guide brackets (6)

Removing and Replacing Parts

4-37 *XLGH%UDFNHW$VVHPEO\ )LJXUH*XLGH%UDFNHW$VVHPEO\5HPRYDO To remove the guide bracket assembly, follow these steps: 1. Remove the system board assembly. 2. Remove any terminator card, if necessary. 3. Remove any SEC cartridge and heat sink assembly, if necessary. 4. Loosen the four captive nuts that secure the guide bracket assembly to the system board (see Figure 4-33). 5. Lift up the assembly and remove it from the four threaded posts. guide bracket assembly captive nuts (4) threaded posts (4)

System Setup Program

A-1 $ 3 3 ( 1 ' , ;  $ 6\VWHP6HWXS3URJUDP This appendix describes the System Setup program, which is used to change the system configuration information stored in NVRAM on the system board. For in-depth information, refer to Chapter 4, “Using the System Setup Pro- gram” in the Dell PowerEdge 4300 Systems User’s Guide. To enter the System Setup program, follow these steps: 1. Turn on (or reboot) the system. 2. Press immediately after you see the message 3UHVV &WUO!$OW!(QWHU!IRU6\VWHP6HWXS. If you wait too long, the operating system begins to load into memory, the message disappears, and you cannot enter the System Setup program. Let the system complete the load operation; then shut down the system and try again. NOTE: To ensure an orderly system shutdown, consult the documentation that accompanied the operating system.

Dell PowerEdge 4300 Systems Service Manual

6\VWHP6HWXS6FUHHQV Figure A-1 illustrates the System Setup program screens, and Table A-1 briefly describes each setup option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Š,, 3URFHVVRU  0+] 3HQWLXPŠ,, 3URFHVVRU  0+] , 'HOO&RPSXWHU&RUSRUDWLRQ ZZZGHOOFRP 3DJHRI 6\VWHP3RZHU(GJHŠ6HWXS (VFH[LW FKDQJHYDOXHV $OW%UHERRW %,269HUVLRQXXX $OW3QH[W 7DE6KLIW7DEFKDQJHILHOGV , 'HOO&RPSXWHU&RUSRUDWLRQ ZZZGHOOFRP 3DJHRI 6\VWHP3RZHU(GJHŠ6HWXS

System Setup Program

A-3 7DEOH$6\VWHP6HWXS2SWLRQV 2SWLRQ )XQFWLRQ Time Resets time on computer’s internal clock. Date Resets date on computer’s internal calendar. Diskette Drive A Diskette Drive B Identifies type of diskette drives installed. Tape drives are not reflected. Reserved Memory Allows a region of system board memory to be supplied by an expansion card with 15M - 16M or None (default). CPU Speed Indicates the processor speed at which the system boots (can toggle to a lower speed). This option should be used only for trouble- shooting purposes; otherwise, do not use. Num Lock On 101- and 102-key keyboards, determines whether system boots with Num Lock acti- vated (does not apply to 84-key keyboards). Processor 1 Processor 2 Displays version or stepping number of the microprocessor in each processor slot on the system board. Fan Speed Sets the fan speed to Full Speed (default) or Noise Reduced. System Alert Sets the system LED to flash when a critical (Fault, the default) or noncritical (Warning) error threshold is passed. Keyboard Errors Enables or disables reporting of keyboard errors during POST. Boot Sequence Determines whether system boots from dis- kette (if present) or hard-disk drive. Scan Sequence Determines the order in which the PCI devices are scanned by the system. System Password Displays current status of system’s password security feature. Also used to assign and verify a new password. The system password is overridden by the setup password. Password Status If set to Locked, prevents the system pass- word from being changed or disabled. Requires that Setup Password option be set to Enabled. Setup Password Restricts access to System Setup program. The setup password overrides the system password. Mouse Enables or disables the built-in PS/2- compatible mouse port.

Dell PowerEdge 4300 Systems Service Manual

Serial Port 1 Serial Port 2 Configures system’s built-in serial ports. These options may be set to Auto (default) to automatically configure a port, to a specific designation (COM1 [3F8h] or COM3 [3E8h] for Serial Port 1; COM2 [2F8h] or COM4 [2E8h] for Serial Port 2), or to Off. Parallel Port Configures system’s built-in parallel port. The port’s I/O address may be set to 378h (default), 278h, 3BCh, or to Off to disable the port. Parallel Mode Controls whether system’s built-in parallel port acts as an AT-compatible (unidirectional) or PS/2-compatible (bidirectional) port. Diskette Controls operation of the system’s built-in dis- kette controller. Speaker Determines whether the built-in speaker is On (default) or Off. Primary SCSI Secondary SCSI Turns the respective SCSI controllers on or off. Selecting On (default) enables a controller and allows scanning of the devices connected to it, allowing the device with the lowest SCSI ID to function as a boot device (unless a boot device connected to an enabled controller higher in the scan sequence has already been detected). Selecting Off causes the BIOS to mask the presence of a controller. Processor field Displays microprocessor type and speed. Level 2 Cache Displays size of integrated cache. System Memory Displays entire amount of installed memory detected in system, except for memory on EMS expansion cards. Video Memory Displays amount of video memory detected. Service Tag Displays system’s five-character service tag number. Asset Tag Displays the asset tag number if one is assigned. 7DEOH$6\VWHP6HWXS2SWLRQV FRQWLQXHG 2SWLRQ )XQFWLRQ

Other Motherboard Manuals