Klein Tools IR1 Instruction Manual
Text of the manual
GFCI Receptacle Tester
(pg. 7)
INSPECTION KIT
• TARGETING LASER
• 10:1 DISTANCE-
TO-SPOT RATIO
• BACKLIT DISPLAY
• AUTO POWER-OFF
• FOR STANDARD AND GFCI
RECEPTACLES
• DETECTS OPEN GROUND,
REVERSE POLARITY, OPEN
HOT, OPEN NEUTRAL,
HOT/GROUND REVERSED
ENGLISH
INSTRUCTI
GENERAL SPECIFICATIONS - IR1
Klein Tools IR1 is an entry-level infrared thermometer with targeting
laser. It offers a wide measurement range, a 10:1 distance–to-spot
ratio, a targeting laser, and user-selectable from Fahrenheit to Celsius
temperature scales.
• Environment: Indoor or outdoor
• Operating Altitude: 6562 ft. (2000 m)
• Relative Hum
To ensure safe operation and service of the tester, follow these
instructions. Failure to observe these warnings can result in severe
injury or death. Retain these instructions for future reference.
WARNING: LASER RADIATION. DO NOT STARE INTO BEAM.
Class II Laser.
• Exposing eyes to laser radiation can result in severe and permanent
eye injuri
1. LCD Display
2. Trigger
3. Battery Compartment Door
4. IR Temperature Sensor
5. Targeting Laser
6. °F/°C Switch (Behind
Battery Compartment Door)
NOTE: There are no
user-serviceable parts
inside meter.
FEATURE DETAILS
ENGLISH
A. Temperature Reading
B. Targeting laser active
C. Data Hold
D. Battery level indicator
E. Active temperature scale
SYM
To measure temperature with the IR1, aim the meter at the object to
be measured, pull the trigger 2 and hold it depressed for at least 2
seconds. Releasing the trigger initiates Data Hold, "HOLD" will show
on the display, and the measurement will be held on the display.
If the display shows "OL" or "–OL" fo
Be sure meter is turned off and wipe with a clean, dry lint-free
cloth. Do not use abrasive cleaners or solvents. Take care
to keep the sensor lens clean at all times. If required, loose
debris may be removed from lens using clean compressed air.
Lens may also be cleaned using a soft cloth or cotton swab
with water or rubbing alcohol only.
GENERAL SPECIFICATIONS - RT210
Relative Humidity: < 85% non-condensing
Operating Temperature: 32° to 140°F (0° to 40°C)
Storage Temperature: 14° to 122°F (-10°C to 50°C)
Operating Altitude: Up to 6562 ft. (2000 m)
Weight: 1.2 oz. (33 g)
Nominal Voltage: 110 - 125V AC at 50/60Hz in 3-wire outlet
Mains Suppl
KLEIN TOOLS, INC.
450 Bond Street Lincolnshire, IL 60069 1-877-775-5346
[email protected] www.kleintools.com
OPERATING INSTRUCTIONS
WIRING CONFIGURATION TESTING
Conditions indicated: wiring correct, open ground, reverse polarity,
open hot, open neutral and hot/ground reversed.
Conditions NOT indicated: quality of