Avnet AT&T Cellular IoT Kit Getting Started Manual

Specifications

Brand: Avnet
Category: Computer Hardware
Model: AT&T Cellular IoT Kit (Getting Started Manual), prmD3seWksQi2
File Type: PDF
File Size: —
Pages: 36 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (36 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 04/04/2026).

Read Online

Read the Avnet AT&T Cellular IoT Kit Getting Started Manual online using the built-in PDF viewer.

AT&T Cellular IoT Kit Getting Started Manual: Key Pages of Document

Copyright © 2017 Avnet, Inc. AVNET, “Reach Further,” and the AV logo are registered

trademarks of Avnet, Inc. All other brands are the property of their respective owners. LIT# 5176-GSG-ATT-IOT_v1 AT&T Cellular IoT Kit Getting Started Guide Version 1.3 ...

Prior Version History:

Version: Date: Comment: 1.0 2016/08/18 Initial Release 1.1 2016/08/25 URL corrections 1.2 2016/11/10 Updated URL correction for OOB demo 1.3 2016/11/29 Added firmware upgrade topic, point to AT&Ts web-site, point to Avnet ARM mbed website. Comments: ...

Revision History .......................................................................................................... 2

Introduction ................................................................................................................. 4 Kit Contents .................................................................................................................................... 5 NXT FRDM-K64F Single Board Computer (SBC) ............................................................................ 6 WNC-Shield Board ....................................................................................................... ...

This guide provides an overview of the Avnet AT&T Cellular IoT Starter Kit hardware and

software. The guide includes steps that allow you to quickly begin using the kit. The example software lets you take measurements using various sensors and send the values to the AT&T M2X/Flow server. Commands, in the form of JSON strings, are sent back to the IoT Starter Kit from the cloud and instruct the device to control on-board components such as the user LED. The IoT Starter Kit consists of a hardware platform comprised of an NXP FRDM-K64F single- board computer (SBC) and an Avnet Arduino-compatible WNC Cellular modem shield mounted on top ...

The kit contains all the elements needed to implement a complete wireless IoT solution. It

includes all the components shown and described below: – AT&T IoT SIM Starter Pack – Quick Start Card – Downloadable example designs and tutorials – Forum support via: http://cloudconnectkits.org/forum/topic/att-cellular-iot-starter-kit Arduino compatible WNC-Shield NXP K64F MCU carrier board with Arduino™ R3 expansion slot 2 LTE antennas 2 USB cables AC power adapter to USB DC 5V ...

NXT FRDM-K64F Single Board Computer (SBC)

The NXP FRDM-K64F SBC is the host development and operational platform (the controller). The elements used by the IoT Kit are as follows: – MK64FN1M0VLL12 MCU (120 MHz, 1 MB flash memory, 256 KB RAM, USB) which is based on a Cortex M4 ARM processor core – RGB LED – The OpenSDAv2 debug circuit supporting the CMSIS-DAP Interface to allow programming and monitoring software – Serial port interface – I2C interface for communicating with off-board sensors – UART interface for communicating with the WNC-Shield card WNC-Shield Board Avnet has produced an Arduino Shield with a Wistron NeWeb Corporati ...

IoT Kit Software

The NXP FRDM-K64F SBC uses the ARM mBed operating software and associated development tools. This allows all development to take place in a Web browser (e.g., Firefox, Chrome, or Explorer) and removes the need to install tools on your PC. Once installed on the Freedom board, the software uses various interfaces such as I2C, GPIOs, and UARTS. At power up, the software configures the hardware and initializes the WNC-Shield card which can take up to 60 seconds to complete. Cellular Shield WNC 14A2A Firmware Before assembling the kit or proceeding to the next steps, please ensure you are using the latest WNC 14A2A firmware. Instruct ...

3. When asked for the Serial Kit Number, use the WNC Serial Number (S/N) as shown below.

4. Once registered, you are logged into the site. A confirmation email is sent to the email address you provided. You now have access to several product support pages as shown. ...

From the AT&T Cellular IoT Starter Kit page, you can view much of the kit’s design

documentation, bill of materials, and other information. Jasper Account for SIM Card You have a choice between purchasing a SIM Card or a complete hardware kit. Both choices come with a data plan and the connectivity API. You must also obtain a free IoT Developer Services account by registering at https://StarterKit.att.com. Once registered, the IoT Developer Services account provides 300 MB of data and 300 SMS messages. ...

ARM mbed.org Account

The software associated with the IoT Kit is located on mbed.org. If you do not have an account, navigate to the mbed website (https://developer.mbed.org/) and follow the instructions to create an account. Once you have an account, you can download and modify the firmware for the kit. AT&T Flow and M2X Accounts To begin using the AT&T Flow and M2X accounts, you need to sign up for an AT&T IoT Services account. This is done by going to https://m2x.att.com/signup and creating an account. ...

Once you are registered, use these same credentials for your Flow account (https://flow.att.com )

and your M2X account (https://m2x.att.com ). The IoT Kit takes advantage of the fact Flow can create the necessary M2X device and streams. To learn how to set up a device manually, go to https://m2x.att.com/onboarding. Flow Account Flow can be entered by selecting Flow from the AT&T IoT Services account dropdown menu, as shown: Flow is a GUI-based IoT development tool based on NodeJS. It allows for data input and output along with user defined rules for up to 100,000 data points per month free of charge. Data flows through nodes from left to right ...

Note: Unlike M2X, Flow times out after a few minutes of inactivity. When this happens, simply

click the Log In button to log back in. Even when you have a fast connection, Flow is slow to respond. If you want to learn by creating your own Flow design from scratch, you can follow AT&T’s instructions that were created for a recent event at: https://att.app.box.com/s/15umqzirkrmgru2yl7utbp8x4jv0bgmg. For the IoT Kit, we start by copying a reference design and modifying it. Each Flow design is unique in terms of its endpoint addresses and account keys, so you need to edit these unique parameters. To duplicate an existing project, follow these ste ...

5. Hover your curser to the right of the new name and click the pencil to change the name to something

unique (e.g., Paul’s Starter Kit Dev). Then click the Fork button. 6. Once the project is Forked, click the Deploy button. This compiles and activates your project. This step takes a minute the first time. Subsequent deploy actions will be quicker. Now that the project is built and deployed, modifications to the WNC-Shield software must be made for it to work properly. These changes are detailed in the section on Compiling. M2X Account M2X is a time-series data store that is free for up to 10 devices. Navigate to https://m2x.att.com or acces ...

Connect Flow and M2X

At this point, it is easiest to have two browser windows open (one for M2X and one for Flow) because the M2X master key must be pasted into the Flow Configuration Function. 1. In M2X, click the Hello power button on the top right and select Account Settings. 2. Highlight the Master Key and copy it to the clipboard. 3. Return to Flow in your other window/tab and find the Configuration function. Notice the graphical design has different tabs for each logical section. The Configuration function is on the Data tab. ...

4. Double-click the Configuration function and a window with the JavaScript appears. Paste the key you

previously copied into the location of the current M2X-Key field and click the OK button. It may take a while for the script to update. 5. At the bottom of the canvas (where the configuration bubble is located), click the Endpoints tab where the Base URL field is located. Click the Copy button. The copied information is used to update two fields: base_hostname and base_url. The Base URL is: https://run-west.att.io/1e464b19cdcde/774c88d68202/86694923d5bf28a/in/flow. The first part, run-west.att.io, is the base_hostname. The base_url is, above, ...

6. Open the Configuration function and paste the fields where they belong. Click the OK button.

7. With the configuration updated, a blue dot appears on your function graphic. This indicates it has changed but has not been deployed. Click the Deploy button to resolve this. ...

8. Flow automatically creates a Virtual Device in M2X for you. This is a one-time operation that has to

be performed. In Flow, go to the Virtual Device tab of the canvas and find the Initialize component in the bottom left. Click once on the solid part to the left of Initialize. 9. You can verify the component has been created in the M2X environment by returning to your M2X window and clicking Devices. Your virtual device should appear. If you expand it by clicking the plus sign (+), you will see the different M2X streams that have been created for it. ...

Assembling the AT&T IoT Kit Hardware

The hardware is delivered as two separate boards. Use the following instructions to connect the boards. 1. Plug the Avnet Cellular shield onto the Arduino connectors on the FRDM-K64F board. 2. Plug the supplied AT&T SIM card into the SIM socket (X3) on the shield. 3. Screw the two antennas to the shield SMAs connectors (X1, X2). 4. The cellular shield requires 5V power supplied by the included AC/DC power adapter. It is not recommended to use a laptop USB port for this power source due to the limited power capabilities of most USB ports. Plug a microUSB cable into the 5V USB shield power (X5) on the Cellular ...

With the hardware set up, connect to a PC and ensure it enumerates as a drive (c:\MBED).

Verify the firmware is at version 0226 or higher by opening the DETAILS.TXT file located on the MBED drive. The following shows how this information is displayed. If the firmware is not at 0226 or higher, update it by following the instruction provided at: https://developer.mbed.org/handbook/Firmware-FRDM-K64F. ...

Computer Hardware PDF Instructions

V100
Lenovo V100
26.05.2026 2 pages

Lenovo 3000 V100 Setup Poster P/N 8/18/2006 Size : 11x14 inches Color : 2 color job = Process Black (This plate must be printed in PMS Process Black C) Process Magenta (This plate must be printed in PMS 1375C)@ Font : IBM Fonts and Helvetica Neue Family Device guide for the Lenovo V100 Laptop. This manual outlines regulatory notices, assembly reference, menu navigation, performance details.

QK A021
Quark-Elec QK A021
30.06.2026 3 pages

www.quark-elec.com Page 1 of 3 2017 QUICK START SET-UP GUIDE QK A021 - AIS Receiver Dongle with Auto-hopping SET UP In the box you should have: 1 x QK-A021 v.2.0 1 x SMA-BNC coaxial adapter 1 x USB extension cable 1 x CD with manuals and drivers Location: Sele Technical instruction manual for the Quark-Elec QK A021 Receiver. This manual provides information on assembly reference, operational guidelines, software updates, specifications.

Simatic S7-1500
Siemens Simatic S7-1500
18.06.2026 26 pages

Step-by-step user manual for the Siemens Simatic S7-1500 Controller. It explains troubleshooting and setup validation, dimensions and layout, operating instructions, user instructions.

Linktropy 5500
Apposite Linktropy 5500
10.06.2026 19 pages

Official installation manual for the Apposite Linktropy 5500 Computer Hardware. This guide presents instructions on detailing setup, safety features, system configuration.