Interface Guide and Reference

Revision R11.9.0 Documentation of the interface between the ComTech modem and the AvL Technologies AAQ antenna controller, reference information, and troubleshooting guide. Appendix E AvL Technologies 900-159-005

AvL Technologies ComTech AvL Technologies ǀ Proprietary – Content is Subject to Change without Notice

1 Revision History Date Revision Revision By Approved By Comments 5/5/14 Rev. 1.0 Initial Release 8/19/15 Rev. 1.1 WL Updates for 11.4 6/28/16 Rev. 11.6.0 WL Change to revision sequence and updates for 11.6 4/17/17 Rev. R11.9.0 WL/SW JF Updates for R11.9.0 Contents 1. Introduction ...................................................................................
AvL Technologies ǀ Proprietary – Content is Subject to Change without Notice 2 4.2. Sensor Output ....................................................................................................................... 9 4.3. Module Window ................................................................................................................. 10 4.3.1. Device Window .................................................................
AvL Technologies ǀ Proprietary – Content is Subject to Change without Notice 3 2. Setup Guide 2.1. Hardware  ComTech CDM Series Modem  AvL AAQ Antenna System  Hub or Switch 2.2. Software Path Main Window → Help  Version Info Level 0 Be certain that the version of Remote Client, ROM, & device module are at or above the version shown in figure 1 Figure 1 – Version info
AvL Technologies ǀ Proprietary – Content is Subject to Change without Notice 4 2.3. Hardware Connection 2.3.1. Serial Communication Connection Connect the AAQ antenna controller and PC or other device running the AAQ Remote GUI Modem to a Network Switch or AvL CIP Rack Mount Interface. The serial communication cable from the AAQ antenna modem should be plugged into the Control port on back of the ComTech modem. Figure 2 - Serial Connectio
AvL Technologies ǀ Proprietary – Content is Subject to Change without Notice 5 3. Configuration 3.1. Core Configuration Path Main Window → View → Configuration, Core tab Level 4 Figure 3 - Core Configuration Long name Level Type Value Range Description ComTech Modem Connection Endpoint 4 Sting - The serial port to us. This should come configured from the factory and should only be changed by an experienced integrator or AvL service te
AvL Technologies ǀ Proprietary – Content is Subject to Change without Notice 6 3.2. Target Configuration Path Main Window → View → Configuration, Target Level 1 Figure 4 - Target Configuration Make sure that Acquisition Sources are set to ComTech. This is done by selecting the drop down list and selecting ComTech. Long name Level Type Value Range Description Scan Source 1 Choice - The signal source to use when performing a Scan for th
AvL Technologies ǀ Proprietary – Content is Subject to Change without Notice 7 3.3. Signal Configuration Path Main Window → View → Configuration, Signal Level 4 Figure 5 - Signal Configuration Refer to the user’s manual for an explanation of signal configuration items Note: When changing Signal parameters, be sure the correct signaling device is selected to the left of the window. 3.4. Feed Configuration Items There are no feed conf

AvL Technologies Modem Owners Instructions: