Hioki PW3365-20 Quick Start Manual

Specifications

Brand: Hioki
Category: Measuring Instruments
Model: PW3365-20 (Quick Start Manual)
File Type: PDF
File Size: —
Pages: 12

Read Online

Read the Hioki PW3365-20 Quick Start Manual online using the built-in PDF viewer.

Text of the manual

Eliminate the risk of

short-circuits and electrical accidents 7he Zorld¶s ¿rst instrument to offer no-metal-contact power measurement Free from the risk of short-circuit accidents since no metal comes into contact with energized parts, the Clamp On Power Logger PW3365-20 can measure voltage, current, and power right on the cable, letting you safely test in locations that were dangerous or even impossible in the past. CLAMP ON POWER LOGGER PW3365-20 Power Meter

How is voltage measured without any metallic contact?

Measure in potentially hazardous locations Voltage Sensor PW9020 Voltage generator Micro current = 0 Voltage generator Internal image 100V PW3365-20 Schematic diagram Principles of operation Wire cross-section Electrode Electrode 100V Measured voltage Generated voltage Voltages balance Freely clip either horizontally or vertically Free yourself from the risk of short-circuits by measuring right on the cable sheath without ever needing to touch metal to energized parts Measure both thick and thin cables The PW3365-20’s dedicated voltage sensor delivers the world’s first no-metal-contact measurement. Locations without energized parts Measure on the outside of cables Inside the PW9020 is an electrode (a metal plate). When there is a potential difference between this electrode and the measured line, a minute current flows as a result. By detecting this minute current and generating a voltage such that the current declines to zero, it is possible to accurately measure the voltage without being affected by the outer diameter of the measured cable or its insulation. Measure without removing the covers Measure at safer points Locations with covered terminals Locations with a risk of electric shock

Soil, residue, or moisture on the insulated wires

may result in lower voltage and power values than their true values. Use a dry cloth to remove before measuring. *includes relay box on cord ! Operating temperature and humidity 0°C to 50°C 32°F to22°F , 0 5+ or less no condensation Storage temperature and humidity -0°C to 60°C °F to 22°F , 0 5+ or less no condensation Dielectric strength .06k Vrms AC Applicable standards Safety E1600, EMC E16326 *1: Shielded wires cannot be measured. *2: For frequencies of 45 Hz to 66 Hz. Effects of humidity: Add the following to the combined accuracy (for voltage, power, and phase) with the PW3365-20 Accuracy within ±1% f.s., phase within ±1°, measuring an insulated wire at a humidity of 70% to 80% RH Effects of adjacent wires: Add the following to the combined accuracy (for voltage and power) with the PW3365-20 Within ±1% f.s. while a wire with a phase difference of 400 V is in contact with the grip Actual maximum size : ij30mm Actual minimum size : ij6mm Compatible conductor diameters Soil, residue, or moisture on the insulated wires may result in lower voltage and power values than their true values. Use a dry cloth to remove before measuring. *includes relay box on cord SAFETY VOLTAGE SENSOR PW9020 Specifications Compatible conductor typ y es Insulated wires*1 In door PVC or metal parts Compatible conductorr diameters Finished outer diameter ij6mm to ij30mm Effective measureementt rangge 0 V to 520 V Accuracy “.5 rdg. “0.2 f.s. combined accuracy with PW3365-20 *2 Effect of phase Accuracy combined with the PW3365-20 is within “.3 at 5060+z, f.s. input Maximum rated voltage to earth CATIV 300V  CATIII 600V Cord length 3m . ft Mass Approx. 220g . oz Actual maximum size : ij30mm Actual minimum size : ij6mm Compatible conductor diameters Enlarged view of clamp

guidance for connection procedures

Quick Setup guides you through the process of setting up the instrument for measurement, right up to starting measurement, on the screen to simplify set work. Since any mistaken connections will trigger a FAIL message, the feature also helps prevent measurement mistakes. If you receive a FAIL result, the instrument will also indicate the location of the problem. Setup Flow (example: 3P4W) Connect the leads to the PW3365-20 Select the current range Measurement Connect the voltage sensor Connect the clamp sensors Check wire connection status Quick Set START / Choose the wire type STEP1 STEP2 STEP3 STEP4 STEP5 STEP6 If you receive a FAIL result Highlight the FAIL message with the cursor and press ENTER to view information about where the connection needs to be corrected. Miswiring Example (Clamp Orientation) The I vector’s phase direction is within the determination area. Green means : PASS Red means : FAIL The I vector’s phase direction is opposite the determination area. P: 6.2kW Power displayed value is too low P: 17.8kW Neither power nor power factor can be measured accurately with the clamp in the wrong orientation. Point the arrow toward the load side Correct Orientation 4 Power supply side Load side FAIL PASS

Trend Graph Display

At the Worksite Review Results Measured values can be displayed as a graph, which is convenient when using the instrument in power management applications. Since you can statistically review not only the measured value at that moment, but also measured values that have been recorded, it’s easy to check values on the spot. Display measured values as a graph and evaluate results at a glance Demand Graph Display * Except for demand Graph of values measured over a period 24 hours at 5-minute intervals Bar graph of values measured over a period of 24 hours at a 30-minute interval It’s easy to check the maximum demand value and the time at which it occurred. Maximum Demand Values cursor Read values at cursor Particularly useful in power management applications Display demand value trends Example Power trend graph display Monitor power variations to check for connections between equipment operating status and power consumption. Identify these parameters right on the time-axis graph display Choose one measured parameter to create a time-series display as a graph Display the maximum, minimum, and average values at the cursor position Read values at cursor Trend Graph Display You can create a bar graph that makes it obvious whether power is being bought or sold by switching the active power demand value display from consumption to regeneration Evaluate Photovoltaic Generation Capabilities (consumption) P dem+ (regeneration) P dem- P dem+ Time kW kW P dem- Power Sold Power Purchased Maximum Value Minimum Value Average Value Data interval (1s to 60min) Set the power logger to save all parameters to record the maximum, minimum, and average values during the set recording interval. Capture and record all fluctuations Maximum data Maximum data Minimum data Minimum data Average data Average data Record Record Display electricity charges Know how much you are spending on electricity in real-time Convert integrated power use to electricity charges Displaying electricity charges Active power use 1 kWh × set rate Calculate electricity charges [ Example screenshot to left ] The electricity charge per 1kWh has been set to $20 Active power use 53.7306kWh × set rate 20 USD electricity charges 1074.61 USD

on a PC

Save &Analyze Storage media for data Loading data Transfer settings from a computer to the PW3365-20 Graph saved data in Excel Load saved data directly from the instrument (via a USB/LAN connection) Trend graph display Example of a Stacked Graph Display Waveform display Print Print data Summary display Copy Report printing Freeware (free download from the Hioki website) Power Logger Viewer SF1001 (option, sold separately/for PW3365,PW3360,PW3198) Easily download and interpret data on a PC Download the measurement results to a computer via the power logger's LAN or USB interface or its SD card. Once data has been downloaded, it can be graphed easily with free software. For more detailed analysis, Hioki’s optional SF1001 application software is recommended. [ Save conditions for above figures ] Measurement target : 3P4W Storage media : Z4001 2-GB SD card Saved parameters : All data: average, maximum, and minimum values Screen copy saving : OFF Waveform save : OFF In all cases, the maximum single file size for measurement data is about 200 MB. When this is exceeded, a new file is created and saving continues. Available Recording Time Measurement Interval Save Time 1 seconds 15.6 days 2 seconds 31.2 days 5 seconds 77.9 days 10 seconds 155 days 15 seconds 233 days Measurement Interval Save Time 30 seconds 1 year 1 minutes 1 year 2 minutes 1 year 5 minutes 1 year More than 10 minites 1 year 2GB 2GB Convenient Functions Automatically Create Excel Graphs Display, tabulate, analyze, and print saved data A B C Power Source Power Source Power Source A B C You can combine power consumption data measured at multiple locations into a single graph to capture the total power demand across a facility, allowing you to identify time periods and locations characterized by high power consumption at a glance. Stores up to one year’s data that is acquired at one minute intervals. Performance cannot be guaranteed on storage media other than SD cards sold by Hioki. Use the free software from the Hioki website in order to download data to a computer using the instrument’s LAN or USB interface The SD port has a cover 6 SD card

The Hioki PW3365-20 is not just a power logger. Added-value features and functions let you meet

many other electrical testing applications. More Uses for the PW3365-20 With the ability to calculate and process data every 200ms, you can do simple checks of intermittent leakage current. Choose from average, maximum and/or minimum value of the measured interval. Example : 3P3W2M+1-channel leakage current Small form factor lets you set the power logger even inside cramped cubicles Battery power Power the instrument for about five hours with batteries if the power goes out Display hold Freeze the displayed value for easier reading Outage recovery Resume recording automatically following recovery from a power outage Measure power + 1-channel of leakage current Measure 3 channels of leakage current Leakage Current Measurement Requires optional clamp-on leak sensor Simultaneous Measurements Other convenient features Measure three single-phase, 2-wire circuits in the same system at the same time. Key lock function Lock the buttons to prevent erroneous operation Control and monitor from a remote location Use a LAN cable to connect the PW3365-20 to a personal computer for real-time remote monitoring and measurement display on a web browser. Files recorded in the Clamp On Power Logger's internal memory or SD card are accessible via a LAN or USB connection, and are downloadable using the free PW3365-20 Setup and Download Software HUB LAN LAN LAN Enter the IP address in the browser. Display the power logger's screen and make adjustments virtually by clicking the buttons and entering new information. Measure power Measure leakage current RMS that includes harmonic components RMS (A) RMS of fundamental wave FND (A) Peak value (waveform peak) PEAK (A) By capturing the RMS of the fundamental wave, you can also identify the leakage current of the 50/60Hz component. Leakage current results Compact, lightweight Load Load Load Load Power Source Power Source Load Load Load Load Load Power Source Power Source Power Source

Number of input channels

Voltage: 3 channels / Current: 3 channels Measurement targets (50/60Hz) Single-phase 2-wire (1P2W, 1P2W  2 circuits, 1P2W 3 circuits) Single-phase 3-wire (1P3W, 1P3W+I, 1P3W1U, 1P3W1U+I) Three-phase 3-wire (3P3W2M, 3P3W2M+I, 3P3W3M/Y-wiring only) Three-phase 4-wire (3P4W), Current only: 1 to 3 channels Simultaneous power/current measurement modes 1P3W+I : 1 power circuit and 1 current channel 3P3W2M+I : 1 power circuit and 1 current channel Measurement items Voltage RMS value, fundamental wave value, waveform peak (absolute value), fundamental wave phase angle, frequency (U1) Current RMS value, fundamental wave value, waveform peak (absolute value), fundamental wave phase angle Power Active power, reactive power, apparent power, power factor, (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration, regeneration), reactive energy(lag, lead) Energy cost display (per-kWh price × power consumption) Demand Active power demand value (consumption, regeneration), reactive power demand value (lag, lead), active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), power factor demand value Voltage range 400 V AC Total display area: 5V to 520 V (less than 5 V displays as 0 V) Effective measurement range: 90 V to 520 V, peak: ±750V [OVER] indicates over-range warning Current ranges Load current CLAMP ON SENSOR 9660 : 5/10/50/100 A CLAMP ON SENSOR 9661 : 5/10/50/100/500 A CLAMP ON SENSOR 9669 : 100/200/1k A CLAMP ON SENSOR 9694 : 500m/1/5/10/50 A CLAMP ON SENSOR 9695-02 : 500m/1/5/10/50 A CLAMP ON SENSOR 9695-03 : 5/10/50/100 A FLEXIBLE CLAMP ON SENSOR CT9667 : 50/100/500 A (500A range) FLEXIBLE CLAMP ON SENSOR CT9667 : 500/1k/5k A (5000A range) Leakage current LEAK CLAMP ON SENSOR 9675 : 50m/100m/500m/1/5 A LEAK CLAMP ON SENSOR 9657-10 : 50m/100m/500m/1/5 A Total display range: Within 0.4 to 130% of the range (zero is suppressed for less than 0.4%) Effective measurement range: Within 5 to 110% of the range [OVER] indicates over-range warning Power ranges 200.00 W to 6.0000 MW Depends on voltage/current combination and measured line type (see Measurement Range Con¿guration Tables) Total display range: Within 0 to 130% of the range (“0W” display indicates zero rms voltage and/or current) Effective measurement area: Within 5 to 130% of the range Measurement accuracy (50/60Hz) Voltage : ±1.5% rdg. ±0.2% f.s. (combined accuracy with PW3365-20 + PW9020) Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy Active power : ±2.0% rdg. ±0.3% f.s. + clamp sensor accuracy (power factor = 1) Calculations RMS calculation/ fundamental wave calculation VT ratio settings Any 0.01 to 9999.99 Selections 1/60/100/200/300/600/700/1000/2000/2500/5000 CT ratio settings Any 0.01 to 9999.99 Selections 1/40/60/80/120/160/200/240/300/400/600/800/1200 Input methods Voltage: Isolated inputs using Voltage Sensor PW9020 Current: Isolated input using a clamp-on sensor Display update rate Approx. 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication) Measurement method Digital sampling and zero cross synchronization calculation method Sampling: 10.24 kHz (2048 points) Calculation processing 50 Hz: Continuous, gapless measurement at 10 cycles 60 Hz: Continuous, gapless measurement at 12 cycles A/D converter resolution 16bit *1 For individual clamp sensors’ accuracy and combined accuracy ¿gures, see pages 10 and 11. PW3365-20 Speci¿cations Product guaranteed for one year No dirt or moisture on insulated wire or voltage sensor

SD Card, internal memory (capacity: approx. 320 KB)

Save interval time 1/2/5/10/15/30 seconds, 1/2/5/10/15/20/30/60 minutes Available storage time is displayed on the PW3365-20's setting screen Save items Measurement save : Average only/average, maximum, minimum Screen save : Saves the displayed screen as a BMP at a ¿xed interval* 1 Waveform save : Stores binary waveform data* 2 Recording start methods Interval time, manual, or at speci¿ed time, repeat Recording stop methods Manual, or at speci¿ed time (up to one year), timer Screen display List Voltage, current, frequency, active/apparent/reactive power power factor, integrated power use, elapsed time U/I RMS value, fundamental wave value, waveform peak, phase angle Power Per-channel and total active power, apparent power, reactive power,power factor Integ Active energy, reactiv energy, recording start time recording stop time, elapsed time, energy cost Demand Active power demand value, reactive power demand value power factor demand value Waveform Displays voltage and current waveform Zoom Enlarged view of 4 user-selected parameters Trend For one selected measurement item displays maximum, average and minimum values External interfaces SD card Settings data, measurement data, screen data, waveform data LAN 10BASE-T/100BASE-TX IEEE802.3 Compliance - HTTP server function USB USB Ver 2.0, Windows 8 (32/64bit)/Windows 7 (32/64bit) / Vista (32bit) /XP - When connected to a computer, the SD Card and internal memory are recognized as removable storage devices. LAN/USB Download settings and data using free application program Functions Trend graph display function Display items Voltage, current, active power, reactive power, apparent power, power factor, frequency, integrated active power, integrated reactive power, demand volume, demand value, voltage disequilibrium factor Stacked bar graph display : Up to 16 types of data series Cursor measurements Measurement values can be displayed by the cursor Summary display function Displayed items are the same as for the trend Graph Display Daily, weekly and monthly report displays: Accumulates and displays daily, weekly and monthly reports over speci¿ed period. Load factor calculation display: Calculates and displays load factor and demand factor results with daily, weekly and monthly reports Time span aggregation: Aggregates data into up to four speci¿ed time spans Waveform display Displays waveform data at speci¿ed date and time Copy function Captures any display image to the clipboard Print function Preview and print content shown on the trend graph, report, harmonic graph and settings displays. Comment entry (Text comments can be entered in any printout) Header/Footer settings: Sets the header and footer for each printout Printing support Any color or monochrome printing supported by the operating system Report printing Print (static) contents over a speci¿c time period Output contents: Standard or selected output items Available output items: Trend graph, summary, daily report, waveform Report creation method: Standard print Report output settings: Save/load report output settings General Specifications Supported models PW3365-20 / PW3360-20 / PW3360-21 Supported computer operating systems Windows 8 (32/64bit) Windows 7 SP1 or later (32/64bit) Windows Vista SP2 or later (32bit) Windows XP SP3 or later (32bit) General Product guarantee One year Display 3.5 inch TFT color LCD (320 × 240 pixel) Japanese, English, Chinese Backlight auto-off function (after 2 minutes) When AUTO OFF is active, the Power LED blinks Operating environment Indoors, Pollution degree 2, altitude up to 2000 m (6562-ft.) Operating temperature and humidity (no condensation) -10°C to 50°C (14°F to 122°F), 80% RH or less During battery operation: 0°C to 40°C (32°F to 104°F), 80% RH or less During battery charging: 10°C to 40°C (50°F to 104°F), 80% RH or less Storage temperature and humidity (no condensation) 0°C to 60°C (32°F to 140°F), 80% RH or less However, the battery˵s storage temperature range is -10°C to 30°C (14°F to 86°F) Maximum rated voltage between terminals Voltage input section : 1.7 VAC, 2.4 Vpeak Current input section : 1.7 VAC, 2.4 Vpeak Maximum rated voltage to earth Voltage input section: 600V Measurement Category III 300V Measurement Category IV Current input section: Depends on clamp sensor in use. Dielectric strength 7.06 kVrms AC Applicable standards Safety: EN61010, EMC: EN61326, EN61000-3-2, EN61000-3-3 Power supply (1) Z1008 AC Adapter : 100 VAC to 240 VAC Maximum rated power : 45VA (including AC adapter) (2) Model 9459 Battery Pack : Ni-MH DC7.2 V 2700 mAh Continuous battery operation time Approx. 5 hr. Maximum rated power : 3VA Charge function Charge time: Max. 6 hr. 10 min. (reference value at 23°C) Charges the battery regardless of whether the instrument is on or off Backup battery life Clock and settings (Lithium battery), Approx. 10 years @23°C (@73.4°F) Dimensions Approx. 180W(7.09") × 100H(3.94") × 48D (1.89") mm (without PW9002) Approx. 180W(7.09") × 100H(3.94") × 68D (2.68") mm (with PW9002) Mass Approx. 540g (19 oz) (without PW9002), Approx. 820g (28.9 oz) (with PW9002) Accessories SAFETY VOLTAGE SENSOR PW9020 (1 set) AC ADAPTER Z1008 (1) USB cable (1) Instruction manual (1) Measurement guide (1) Color spiral tubes (1 set : red, yellow, blue/four each) Spiral tubes (10) POWER LOGGER VIEWER SF1001 Speci¿cations *1 The minimum interval time for saving screen copies is 5 min. If the setting is less than 5 min., screen copies will be saved every 5 min. *2 With shortest interval of 1 minute.When set to less than 1 minute, waveforms are saved once every minute

CLAMP ON SENSOR

9694 Cord length 3 m (9.84ft) Cord length Sensor - circuit: 2 m (6.56ft) Circuit - connector: 1 m (3.28ft) Cord length 3 m (9.84ft) Cord length : 3 m (9.84ft) Cord length : 3 m (9.84ft) Cord length 3 m (9.84ft) Cord length 3 m (9.84ft) FLEXIBLE CLAMP ON SENSOR CT9667 CLAMP ON LEAK SENSOR 9657-10 Leakage Current Measurement Only Leakage Current Measurement Only CLAMP ON SENSOR 9660 CLAMP ON SENSOR 9661 CLAMP ON SENSOR 9669 CLAMP ON LEAK SENSOR 9675 CLAMP ON SENSOR 9695-02 Connect with the 9695-02/-03, Output BNC terminal CLAMP ON SENSOR 9695-03 Measurable conductor diameter ij55mm (2.17") 80 (3.15")×20 (0.79")mm ij15mm (0.59") ij15mm (0.59") ij46mm (0.81") ij15mm (0.59") ij15mm (0.59") Primary current rating 5A AC 100A AC 500A AC 1000A AC 50A AC 100A AC Frequency characteristic 40Hz to 5kHz Within ±1.0% Within ±1.0% Within ±1.0% Within ±2.0% Within ±1.0% Within ±1.0% Effect of external magnetic field with a magnetic field of 400 A/ m AC Equivalent to 0.1 A or less Equivalent to 0.1 A or less Equivalent to 0.1 A or less Equivalent to 1 A or less Equivalent to 0.1 A or less Equivalent to 0.1 A or less Effect of conductor position Within ±0.5% Within ±0.5% Within ±0.5% Within ±1.5% Within ±0.5% Within ±0.5% Maximum rated voltage to earth CAT III 300V rms CAT III 300V rms CAT III 600V rms CAT III 600V rms CAT III 300V rms CAT III 300V rms Maximum input 45-66Hz 50A continuous 130A continuous 550A continuous 1000A continuous 60A continuous 130A continuous Dimensions / Mass 46W × 135H × 21D mm / 230g (1.81") × (5.31") × (0.83") / (8.1 oz) 46W × 135H × 21D mm / 230g (1.81") × (5.31") × (0.83") / (8.1 oz) 77W × 151H × 42D mm / 380g (3.03") × (5.94") × (1.65") / (13.4 oz) 99.5W×188H×42D mm/ 590g (3.92")×(7.40")×(1.65") / (20.8 oz) 50.5W×58H×18.7Dmm / 50g (2.28")×(2.28")× (0.74") / (1.8 oz) 50.5W×58H×18.7Dmm / 50g (2.28")×(2.28")×(0.74") / (1.8 oz) Accuracy Amplitude (45 to 66 Hz) / Phase (45 Hz to 5 kHz) ±0.3% rdg.±0.02% f.s. ±0.3% rdg.±0.02% f.s. ±0.3% rdg.±0.01% f.s. ±1.0% rdg.±0.01% f.s. ±0.3% rdg.±0.02% f.s. ±0.3% rdg.±0.02% f.s. Within ±2° Within ±1° Within ±0.5° Within ±1° Within ±2° Within ±1° Measurable conductor diameter Measurable conductor diameter Effect of external magnetic field Effect of external magnetic field 7.5mA max. Accuracy Accuracy 45-66Hz Maximum input Maximum input 45-66Hz 45-66Hz Primary current rating Primary current rating Effect of conductor position Effect of conductor position Maximum rated voltage to earth Maximum rated voltage to earth CAT III 1000V rms / CAT IV 600V rms Frequency Frequency Within ± 5% Within ± 5% 10-20kHz 40 - 5kHz Dimensions / Mass Dimensions / Mass 74W× 145H × 42D / 380g 60W× 112.5H × 23.6D / 160g Power supply Notes Cord length: 3 m (9.84ft) CONNECTION CORD 9219 Insulated conductor Insulated conductor Insulated conductor Insulated conductor ij254mm ij40mm ij30mm 1.5% / f.s. or less 7.5mA max. ±2.0% rdg ± 0.3% f.s. / Within ±1° ±1.0% rdg ±0.05% f.s. / Within ±3° ±1.0% rdg ±0.05% f.s. / Within ±5° 10000A continuous 30A continuous 10A continuous AC500A/ AC5000A AC10A* AC10A* CAT III 300V rms CAT III 300V rms Within ± 3% Within ±0.1% Within ±0.1% Within ± 3dB Circuit box: 35W×120.5H×34D/470g LR06 alkaline battery × 2 or AC ADAPTER 9445-02/9445-03 (optional) Not used for power measurements *Maximum AC measurement range with PW3365-20 is 5A Not used for power measurements *Maximum AC measurement range with PW3365-20 is 5A

±2.3% rdg. ±0.31% f.s.

100.00A ±2.3% rdg. ±0.32% f.s. ±2.3% rdg. ±0.35% f.s. 50.000A ±2.3% rdg. ±0.34% f.s. ±2.3% rdg. ±0.4% f.s. 10.000A ±2.3% rdg. ±0.5% f.s. ±2.3% rdg. ±0.8% f.s. 5.0000A ±2.3% rdg. ±0.7% f.s. ±2.3% rdg. ±1.3% f.s. Range 9669 1.0000kA ±3% rdg. ±0.31% f.s. 200.00A ±3% rdg. ±0.35% f.s. 100.00A ±3% rdg. ±0.4% f.s. Range 9694 9695-02 50.000A - ±2.3% rdg. ±0.32% f.s. 10.000A - ±2.3% rdg. ±0.4% f.s. 5.0000A ±2.3% rdg. ±0.32% f.s. ±2.3% rdg. ±0.5% f.s. 1.0000A ±2.3% rdg. ±0.4% f.s. ±2.3% rdg. ±1.3% f.s. 500.00mA ±2.3% rdg. ±0.5% f.s. ±2.3% rdg. ±2.3% f.s. Range CT9667 5.000kA range CT9667 500A range 5.0000kA ±4% rdg. ±0.6% f.s. - 1.0000kA ±4% rdg. ±1.8% f.s. - 500.00A ±4% rdg. ±3.3% f.s. ±4% rdg. ±0.6% f.s. 100.00A - ±4% rdg. ±1.8% f.s. 50.000A - ±4% rdg. ±3.3% f.s. CLAMP ON SENSOR 9660 / 9695-03 / 9661*2 Voltage Connection Current 9661only 5.0000A 10.000A 50.000A 100.00A 500.00A 400.0V 1P2W 2.0000kW 4.0000kW 20.000kW 40.000kW 200.00kW 1P3W 1P3W1U 3P3W2M 3P3W3M 4.0000kW 8.0000kW 40.000kW 80.000kW 400.00kW 3P4W 6.0000kW 12.000kW 60.000kW 120.00kW 600.00kW CLAMP ON SENSOR 9669 Voltage Connection Current 100.00A 200.00A 1.0000kA 400.0V 1P2W 40.000kW 80.000kW 400.00kW 1P3W 1P3W1U 3P3W2M 3P3W3M 80.000kW 160.00kW 800.00kW 3P4W 120.00kW 240.00kW 1.2000MW CLAMP ON SENSOR 9694 / 9695-02 *1 Voltage Connection Current 500.00mA 1.0000A 5.0000A 10.000A 50.000A 400.0V 1P2W 200.00W 400.00W 2.0000kW 4.0000kW 20.000kW 1P3W 1P3W1U 3P3W2M 3P3W3M 400.00W 800.00W 4.0000kW 8.0000kW 40.000kW 3P4W 600.00W 1.2000kW 6.0000kW 12.000kW 60.000kW *1 For the 9694 sensor, the range of guaranteed accuracy is from 500 mA to 5 A, and for the 9695-02, from 500 mA to 50 A. *2 For the 9660 and 9695-03 sensors, the range of guaranteed accuracy is from 5 A to 100 A and for the 9661, from 5 A to 500 A. Leak current: CLAMP ON LEAK SENSOR 9657-10, 9675 Range 50.000mA / 100.00mA / 500.00mA / 1.0000A / 5.0000A Apparent power ±1 dgt. for the calculation obtained from each measurement value Reactive power Fundamental waveform calculations ±2.0% rdg. ±3.0% f.s. + clamp-on sensor accuracy (w/power factor = 1) Rms calculations From each measurement applied to calculation ±1 dgt. Energy Active and reactive power measurement accuracies ±1 dgt. Power factor From each measurement applied to calculation ±1 dgt. Frequency ±0.5% rdg. (with 90 to 520 V sine wave input) Demand value Active and reactive power measurement accuracies ±1 dgt. Demand quantity Active and reactive power measurement accuracies ±1 dgt. Conditions of guaranteed accuracy After 30 minute warm-up, with 50/60 Hz sine wave input voltage to earth 400V or less Temperature and humidity for guaranteed accuracy 23˚C ±5˚C (73 ± 9°F), 80%RH or less (applies to all specifications unless otherwise noted) Display area of guaranteed accuracy Effective measurement range Period of guaranteed acuracy 1 year Real-time clock accuracy Within ±0.3 sec/day (with power on, within specified operating temperature and humidity ranges) Temperature characteristic Within ±0.1% f.s./ ˚C (except 23 ±5°C) Effect of external magnetic field Within ±1.5% f.s. (in a magnetic field of 400 A/m rms AC, 50/60 Hz) Effect of radiated, radio-frequency, electromagnetic field Within ±5% f.s. for voltage and active power at 10 V/m Range Total display range Effective measurement range Total display range Effective peak Minimum Minimum Maximum Maximum Range Voltage 400V Range 5.0V 90.0V 520.0V 520.0V ±750Vpeak Current 5A Range 0.0200A 0.2500A 5.5000A 6.5000A ±20Apeak 10A Range 0.040A 0.500A 11.000A 13.000A ±40Apeak 50A Range 0.200A 2.500A 55.000A 65.000A ±200Apeak 100A Range 0.40A 5.00A 110.00A 130.00A ±400Apeak 500A Range 2.00A 25.00A 550.00A 650.00A ±1000Apeak Measurement Range Con¿gurations Current Display and Effective Measurement Ranges typical Combined Accuracy PW3365-20 + PW9020 + clamp sensors FLEXIBLE CLAMP ON SENSOR CT9667 (CT9667-500A) Voltage Connection Current 50.00A 100.00A 500.00A 400.0V 1P2W 20.000kW 40.000kW 200.00kW 1P3W 1P3W1U 3P3W2M 3P3W3M 40.000kW 80.000kW 400.00kW 3P4W 60.000kW 120.00kW 600.00kW FLEXIBLE CLAMP ON SENSOR CT9667 (CT9667-5kA) Voltage Connection Current 500.00A 1.0000kA 5.0000kA 400.0V 1P2W 200.00kW 400.00kW 2.0000MW 1P3W 1P3W1U 3P3W2M 3P3W3M 400.00kW 800.00kW 4.0000MW 3P4W 600.00kW 1.2000MW 6.0000MW

81 Koizumi, Ueda, Nagano, 386-1192, Japan

TEL +81-268-28-0562 FAX +81-268-28-0568 http://www.hioki.com / E-mail: [email protected] HIOKI USA CORPORATION: TEL +1-609-409-9109 FAX +1-609-409-9108 http://www.hiokiusa.com / E-mail: [email protected] All information correct as of June 20, 2014. All speci¿cations are subject to change without notice. PW3365E1-46E Printed in Japan DISTRIBUTED BY HIOKI (Shanghai) SALES & TRADING CO., LTD.: TEL +86-21-63910090 FAX +86-21-63910360 http://www.hioki.cn / E-mail: [email protected] HIOKI INDIA PRIVATE LIMITED: TEL +91-124-6590210 FAX +91-124-6460113 E-mail: [email protected] HIOKI SINGAPORE PTE. LTD.: TEL +65-6634-7677 FAX +65-6634-7477 E-mail: [email protected] HIOKI KOREA CO., LTD.: TEL +82-42-936-1281 FAX +82-42-936-1284 E-mail: [email protected] Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies. CLAMP ON POWER LOGGER PW3365-20 Clamp On Power Logger PW3365-20 by itself does not support current and power measurements. Current and power measurements require clamp on sensors, sold separately. Use only HIOKI SD cards guaranteed to work for saving measurement data (options, sold separately). For purchase as replacement battery pack BATTERY PACK 9459 Options Accessories SD MEMORY CARD 2GB Z4001 LAN CABLE 9642 CARRYING CASE C1005/C1008 AC ADAPTER Z1008 SAFETY VOLTAGE SENSOR PW9020 POWER LOGGER VIEWER SF1001 Supported computer operating systems Windows 8 (32/64bit) Windows 7 SP1 or later (32/64bit) Windows Vista SP2 or later (32bit) Windows XP SP3 or later (32bit) Trend graph display function Summary display function Waveform display Print function Report printing BATTERY SET PW9002 Battery Case and Battery Pack Set CLAMP ON LEAK SENSOR (for leakage current measurement) CLAMP ON SENSOR (for load current measurement) CLAMP ON ADAPTER 9290-10 Primary side 1000A Secondary side 100A CLAMP ON SENSOR 9694 (AC5A) CLAMP ON SENSOR 9660 (AC100A) CLAMP ON SENSOR 9661 (AC500A) CLAMP ON SENSOR 9669 (AC1000A) FLEXIBLE CLAMP ON SENSOR CT9667 (AC5000A) CLAMP ON SENSOR * 9695-02 (AC50A) CLAMP ON SENSOR * 9695-03 (AC100A) CONNECTION CORD 9219 (for connection to 9695-02, 9695-03) CLAMP ON LEAK SENSOR 9657-10 CLAMP ON LEAK SENSOR 9675 * When purchasing the 9695-02 and 9695-03, we recommend also purchasing the separately sold 9219 Connection Cord. C1005 C1008 Dimension : 390 W (15.4") (Approx) 275 H (10.8") 110 D (4.3") mm Includes standard For separate purchase PW3365-20 is bundled with 4 sensors Additional single sensors also available Cord length: 3m (9.84 ft) 390 W (15.4") 275 H (10.8") 150 D (5.9") mm Stores up to one year’s data when acquired at one minute intervals. Performance cannot be guaranteed on storage media other than Hioki-specified SD card options. SAFETY VOLTAGE SENSOR PW9020 (1 set) AC ADAPTER Z1008 (1) USB cable (1) Instruction manual (1) Measurement guide (1) Color spiral tubes (1 set : red, yellow, blue/four each) Spiral tubes (10) CAT III 600V Cord length: 3m (9.84 ft) Measurable conductor diameter Bus bar : 80 mm (3.46in) 5 20 mm (0.79 in) CT ratio : 10:1 ij55 mm (2.17in) MAX. 1500A AC (continuous: 1000A)

Other Measuring Instruments Manuals