Handicare SystemRoMedic EvaDrive User Manual Manual

Specifications

Brand: Handicare
Category: Mobility Aid
Model: SystemRoMedic EvaDrive
File Type: PDF
File Size: —
Pages: 20

Read Online

Read the Handicare SystemRoMedic EvaDrive User Manual Manual online using the built-in PDF viewer.

Text of the manual

SWL: 205 kg/450 lbs

270 kg/600 lbs SystemRoMedic TM Instructions for use - English Bruksanvisning - Svenska Brukermanual - Norsk Brugsvejledning - Dansk Käyttöohje - Suomi Gebrauchsanweisung - Deutsch Handleiding – Nederlands Manuel utilisateur - Français Manuale utente – Italiano Manual de usuario – Español EvaDrive Manual nr: 674 Rev 5

EvaDrive a motor of Eva mobile lifts and is available as an accessory. It has been developed to meet the increasing

need for power assistance when maneuvering a user in the mobile lift. EvaDrive unit supplies the power by its motorised wheels and is controlled by the unique intuitive handle bar. Visual inspection Inspect lift functions regularly. Check to ensure that material is free from damage. Before use Make certain the lift is properly assembled. Check lifting function and base-width adjustment. Check driving function in all directions. Check that the accessory (EvaDrive) is properly mounted on the lift. Always read the user manuals for all assistive devices used during a transfer. Keep the user manual where it is accessible to users of the product. Always make sure that you have the right version of the user manual. The most recent editions of user manuals are available for downloading from our website, www.handicare.com. Under no circumstances may a lift with EvaDrive be used by persons who have not received instruction in the operation of a lift with the accessory mounted. It is strongly prohibited to modify the original product. Always read the user manual 4 I N S T R U C T I O N S F O R U S E SystemRoMedic TM EvaDrive

Unpacking and inspection

The following is included in the EvaDrive package: • Handlebar • EvaDrive unit • Allen key • 2 screws + bracket for handlebar The following is included in the EvaDrive battery package: • Battery (Replaces the battery of Eva mobile lift) • Charger • Charger cable Check to ensure that no components are left in the packaging. Inspect the drive unit for signs of damage. Periodic inspection must be performed at least once yearly. Use only original spare parts. Service and maintenance must be performed according to instructions in the manual. The drive unit must be charged for at least 10 hours before it is used for the first time. Install the drive unit on the lift according to the accompanying assembly instructions. (Separate document) Assembly must be performed by Handicare authorized personnel. 33.4 inch/ 850 mm Installation of the handlebar The handlebar must be installed on the mast at a height of at least 33.4 inch from the floor. Measure from the lowest point of the handlebar. The handlebar is secured using the accompanying Allen key. The complete Eva lift package with EvaDrive includes the following: • Handlebar • 2 screws + bracket for handlebar Intended use of the product EvaDrive in an add-on system to Handicare Eva Mobile lifts in order to provide a power assisted drive function to the rear wheels. The EvaDrive system can either be delivered as an accessory to be retro-fitted to Eva450EE or Eva600EE, or as a complete unit with the drive system fitted from the factory. The EvaDrive shall be used in the following situations and environments: • In a passive patient lift situation with a user in the lift, reducing the effort from the caregiver when maneuvering the lift. • In a dry environment and on a level surface. • Home Care environments. • Healthcare environments. 5 I N S T R U C T I O N S F O R U S E SystemRoMedic TM English

Installation of cables

Connect the battery cable and the cable for the hand control. Secure the hand control cable with the retainer. Connect the motor cable and turn to lock in place. Cable for hand control Battery cable Motor cable Final inspection • Check to ensure that no components are left in the packaging. • Inspect the product for signs of damage. • Inspect wheels and brakes. • Check mechanical brake function by activating the brakes and, without activating EvaDrive, try to move the lift forward. If the lift does not move, the brakes function as they should. • Check all connections, screws and bolts. • Check emergency-stop function by activating EvaDrive; press the emergency-stop button, and then press the up or down button. If nothing happens, the emergency stop is functioning as it should, since it stops all electrical functions. • Using the hand control, activate EvaDrive, press the up button and run the lift boom all the way up. Then, press the down button and run the boom all the way down. • Test base-width adjustment. Activate the system, press the button for base-width adjustment, open the undercarriage to maximum width, and then press the other button to reduce the width. • If the lift is functioning as it should, connect the charger and check to ensure that the red charging indicator light on the charger lights up. • Activate EvaDrive and grasp the handlebar with both hands, hold the safety switch in, and then run the lift forward, backward and in a turning motion. Check that the lift moves easily, to both the right and to the left. • Test the rear wheels by turning them a bit; turn the lift back and forth. Turn the wheels all the way and run the lift sideways. Check that the yellow light lights up when the wheels turn and are turned, and that the light goes out when the wheels are returned to the normal position. NOTE! The lift must be charged for at least 10 hours before it is used for the first time. See section on battery charging. Keep the manual where it is easily accessible for users of the product. 6 I N S T R U C T I O N S F O R U S E SystemRoMedic TM

Using the product

Important information • The accessory must be assembled according to the assembly instructions included with the product. • The lift, with the accessory installed, may only be operated indoors on a dry and level surface. • Never leave a user unattended during a transfer. • Maximum load may under no circumstances be exceeded. See section on maximum load. • The lift must not be lowered into water or used in the shower. • The lift must not be left or stored in a damp or humid environment. • The lift must not be charged in a wet room. • For optimal function, inspect the lift regularly. See section on Maintenance. • Warranty applies only if repairs or alterations are made by authorized personnel. • Never attempt to lift the mobile lift unit by the handlebar. • Ensure that there are no obstacles or people in the way of the lift. • Never stand on the lift during operation. Always walk behind the lift. • Low speed is recommended when a user is seated in a sling attached to the lift. • The lift must not be used in oxygent-enriched environments. • Handle the battery with care. Do not drop. • Use only batteries, cables and chargers intended for EvaDrive. • If a lift is attempted at an angle, a safety function will temporarily pause the lifting motion. Ensure that the EvaDrive is correctly positioned over the user, or let the EvaDrive position itself with the brakes unlocked. Once the lift is in its correct position, the lifting motion will automatically be resumed. 7 I N S T R U C T I O N S F O R U S E SystemRoMedic TM English

Safe working load

Different products on the same lift system (lift unit, sling and other lifting accessories) may have different allowable safe working loads. The lowest allowable safe working load always determines the safe working load of the assembled system. Always check the safe working loads for the lift and accessories before use. Contact your local Handicare representative or dealer if you have any questions. Red indicator light Service required Yellow indicator light Wheel turning activated Green indicator light Low speed activated Low speed button Rear wheel direction controls Battery level indicator Power button Description of functions and symbols EvaDrive has many built-in functions. Each function is described in the respective section in the user manual, or in the user manual for the respective accessory. Below is a brief description of the functions that are available for caregivers and users. Blue/white Read user manual May not be discarded in domestic waste Medical Device Class I. The product complies with the requirements of the Medical Devices Directive 93/42/EEC. Type B, according to the degree of protection against electric shock. The device is intended for indoor use. Class lI equipment Conforms to ISO 10535:2006 with ANSI/AAMI ES 60601-1:2005 and is certified to ISO 10535:2006 with CSA-C22.2 No. 60601-1:08 Yellow/Black International General Warning Symbol Yellow/Black Warning. Pinch point Tested according to: ANSI/AAMI HA60601-1-11:2011, ANSI/AAMI ES60601-1:2005/(R)2012, CAN/ CSA-C22.2 no. 60601-1:14 CAN/CSA-C22.2 no. 60601-1:14 8 I N S T R U C T I O N S F O R U S E SystemRoMedic TM

Red indicator light - Solid red light indicates that service is required. Blinking at the same time as

one of the lights on the battery scale: error code, see troubleshooting. Blinking at the same time as the lights on the battery scale are not on indicates that the battery must be charged. Yellow indicator light - Solid light indicates rear wheels are turned. The lift can then only be moved sideways. Light turned off indicates that the rear wheels are in normal position and the lift can be driven forward/backward. Green indicator light - Solid light indicates low speed. Blinking indicates the need for calibration. (Switch off, wait fot 10 seconds and swich back on.) No light, normal condition. Battery level - Solid light indicates battery capacity remaining. Blinking light indicates error. A service technician can determine the source of the error. Power button - Press lightly to activate EvaDrive. (Wait about 2 seconds before operating.) Press again to deactivate EvaDrive. Low speed button - Press once to set the system for low speed (green light switches on); press again to resume normal operation (light switches off). Rear wheel direction controls - Press the left button to set the rear wheels at an optional angle. Press the right button to resume normal wheel setting. Motion ceases as soon as pressure on the buttons is released. Preventative service/maintenance The symbol for service/maintenance lights up automatically when the lift unit has been in service for 12 months. Contact an authorized Handicare service technician for maintenance and resetting. 9 I N S T R U C T I O N S F O R U S E SystemRoMedic TM English

Press the power button once to activate EvaDrive. The lift is ready for opera-

tion after about 2 seconds. No load should be applied to the handlebar or the orange safety switch when the lift is being started; calibration takes place instantaneously when the the system is starting up. Grasp the handlebar, including the safety switch, and apply pressure to the handlebar in the desired direction of travel; the lift will then begin to move. The handlebar senses the desired speed and direction of travel, and adapts to the right level. Transfer/movement of the lift is more gentle and more even if the arms are somewhat relaxed while manoeuvring the lift. To turn, simply apply a light pressure to the handlebar in the desired direction. NOTE! Only minimal pressure is required to manoeuvre EvaDrive, regardless of the load on the lift. Safety check before starting After starting the lift, do not touch the handlebar for a few seconds to allow the lift to automatically calibrate. While this is happening, the green light beside the low-speed button will blink quickly; operation of the lift is not possible until EvaDrive has completed automatic calibration. If the handlebar is hit violently or subjected to impact, the sensors’ neutral values can be affected so much that the blinking warning will not stop. In this case, manual calibration must be done according to the following instructions. Manual calibration of EvaDrive Hold the orange safety switch in while EvaDRive is starting up. This will cause the green light to blink slowly. Continue to hold the safety switch in for about 5 seconds until the green light starts to blink faster. Release the safety switch and do not touch the handlebar until the green light stops blinking (after about 10 seconds). Using the parking brakes The parking brakes are activated by being pushed down and deactivated by being pushed up wards. When the brakes are activated they are automatic and only switched on when the lifts is standing still and are released when a signal is given trough the handlebar. A click is heard when the brakes are switched on or off. When the brakes are deactivated the lift can be moved manually even though it moves easier if the drive system is shut off. It is recommended that the brakes are deactivated during lifts. 10 I N S T R U C T I O N S F O R U S E SystemRoMedic TM

The green light blinks, but stops after a while.

Automatic calibration complete The green light blinks. - Manual calibration is required, see section on manual calibration. - Check to ensure that no load was applied to the handlebar when the lift was started e.g., that nothing was hanging on the handlebar. In that case, remove it and the green light will stop blinking. All or parts of the battery scale blink quickly. Something is wrong with the lift’s electrical system. Restart EvaDrive. If there is still a problem, contact Handicare. Red light + battery scale blink - Restart - Contact Handicare If unusual sounds are heard: - Try to locate the source of the sound. - Take the lift unit out of service and contact Handicare. The lift cannot be started - Check the battery switch. - Check battery connection. - Connect charger and charge for at least 2 hours. - Contact Handicare. 11 I N S T R U C T I O N S F O R U S E SystemRoMedic TM English

Optimal pattern of operation

Normal travel in corridors and open areas Ensure that the rear wheels are in the normal position, see Fig. 1. Grasp the handlebar and hold in the safety switch, then move the lift. The lift will sense both the desired direction of travel and speed. The lift has a greater turning radius at this setting. When manoeuvring in confined areas the rear castor wheel function can be used to advantage. Manoeuvre the lift as far as possible at this setting, then press the button for rear wheel adjustment and hold it pressed in until the desired wheel angle is obtained, see Fig. 2. The yellow LED light on the control panel indicates that the wheels are in the turned position. Grasp the handlebar and hold in the safety switch, then turn the lift in the desired direction to rotate. If the button for rear wheel adjustment is held in until the wheels stop in their outermost position, the lift can be moved all the way to one side, see Fig. 3; This setting can be very useful for repositioning the user further up in bed, for example. If the low-speed symbol is pressed, the max. speed is limited, thereby enabling greater precision in confined spaces. NOTE! Be aware of the pinch point when the rear wheels are turning. Figure 1. Wheels adjusted for forward motion Figur 2. Rotation Figure 3. Lateral travel 12 I N S T R U C T I O N S F O R U S E SystemRoMedic TM

Always charge the lift after use to ensure that the battery is fully charged.

Charging procedure: • Connect the charger cable to the batterypack, plug in the wall socket and switch on at plug socket. • Check to ensure that the light on the charger lights up and that the battery’s power switch is switched on! • Charging stops automatically when battery is fully charged. NOTE! The lift must be charged for at least 10 hours before it is used for the first time. For maximum service life, charge batteries regularly. We recommend daily charging when the lift is used daily. Only the dedicated charger may be used. Emergency stop Emergency stop: Press the emergency-stop button on the EvaDrive cover. Emergency stop switches off all of the lift’s electrical functions. The battery scale continues to light continuously. Resetting: Turn the emergency-stop button in the direction of the arrows until the button pops out. Compatibility EvaDrive is adapted for Eva450EE (60900002) and Eva600EE (60900003). 1. The green LED light confirms that the charger is connected to the power outlet and is receiving power. 2. Red light indicates charging. 3. Green light indicates full charge. Changing the battery Loosen the two screws that holds the handlebar using an Allen key, and move up wards as far as possible. Remove the battery cable. Slide the battery off the rails on the on the backplate mounted on the mast. Slide the new battery into the rails. reattach the handlebar and the battery cable. Handle the battery with care. Do not drop. 13 I N S T R U C T I O N S F O R U S E SystemRoMedic TM English

The lift must undergo thorough inspection at least once per year. Inspection must be performed by authorized personnel

and in accordance with Handicare’s service manual. Repairs and maintenance may only be done by authorized personnel using original spare parts. Used batteries are to be left at the nearest recycling station. Used batteries can also be returned to Handicare or a Handicare dealer for recycling. +50 ºC -10 ºC Cleaning/disinfection If necessary, clean the lift with warm water or a soap solution and check that the castors are free from dirt and hair. Do not use cleaning agents containing phenol or chlorine, as this could damage the aluminium and the plastic materials. If disinfection is needed, 70 % ethanol, 45 % isopropanol or similar should be used. Disinfect the parts that come in contact with a user before the lift is used for the next user. Storage and transportation If the lift is not to be used for some time or e.g., during transport, we recommend that the emergency stop button be pressed in. The lift should be transported and stored in -10 ° C to + 50 ° C and in normal humidity, 30% -75 %. The air pressure should be between 700 and 1060 hPa. Let the lift reach room temperature before the batteries are charged or the lift is used. Service agreements Handicare offers service agreements for maintenance and regular testing of your lift unit. Contact your local Handicare representative. 106 kPa 70 kPa 75% 30% 1060 hPa 700 hPa +50 °C -10 °C 75% 30% 14 I N S T R U C T I O N S F O R U S E SystemRoMedic TM

Medical Device Class I. The product complies with the requirements of the Medical Devices Directive 93/42/EEC.

Maximum speed (normal) Forward: 4.3 mph / 7 km/h, Backwards: 2.1 mph / 3,5 km/h Maximum speed (low speed ) 2.1 mph / 3,5 km/h Batteries 24V, 17,6 Ah Li-Ion Charger Modiary MDA10129402000. Output: DC 29, 40 V, 2.0 A AC power input cable HD3VV-F 3G0,75mm². TCA090812EA. Length 59 inch, 1500 mm Motor cover Flame-resistant ABS plastic Intermittent operation Op 10/90, active op. max. 2 min. Out of a time of 100, active time must be less than 10, though not more than 2 min. Nav motor 24V DC Mono Shaft, 180 W Material Aluminium/steel Emergency lowering Manual Castors 8 inch, 203 mm IP class IP X4* Weight Eva450Drive: 127.87 lbs, 58 kg Eva600Drive: 141.1 lbs, 64 kg Weight (heaviest part) Eva450Drive: 97 lbs, 44 kg Eva600Drive: 110.2 lbs, 50 kg Turning diameter Eva450Drive: 54 inch/ 1340 mm Eva600Drive: 61.8 inch/ 1570 mm Expected service life 10 years Pressure control panel 4 N Clearance 1.1 inch, 28 mm *IP X4: Splashing of water, Water splashing against the enclosure from any direction shall have no harmful effect. (Test duration: 5 minutes Water volume: 10 litres per minute Pressure: 50–150 kPa) Technical information This equipment/system is intended for use by healthcare professionals only. This equipment/system may cause radio interference or may disrupt the operation of nearby equipment. It may be necessary to take mitigation measures, such as reorienting or relocating the equipment/system or shielding the location. EMC 15 I N S T R U C T I O N S F O R U S E SystemRoMedic TM English

All measurement are in mm/inch

Tolerance +/- 5 mm/ 0.2” *When the handle is placed 1000 mm from floor Eva450Drive 25/0.9 427/16.8 1307/51.4 *1450/57.1 240/9.4 900-1100/35.4-43.3 124 I N S T R U C T I O N S F O R U S E SystemRoMedic TM

All measurement are in mm/inch

Tolerance +/- 5 mm/ 0.2” Eva600Drive *When the handle is placed 1000 mm from floor 806/31.7 395/15.5 25/0.9 432/17 1408/55.4 *1566/61.6 240/9.4 900-1100/35.4-43.3 125 I N S T R U C T I O N S F O R U S E SystemRoMedic TM

Guidance and manufacturer’s declaration – electromagnetic emissions

The EvaDrive is intended for use in the electromagnetic environment specified below. The customer or the user of the EvaDrive should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment - guidance RF emissions CISPR 11 Group 1 The EvaDrive uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions CISPR 11 Class A The EvaDrive is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Harmonic emissions IEC 61000-3-2 Class A Voltage fluctuations/ flicker emissions IEC 61000-3-3 Complies 126 I N S T R U C T I O N S F O R U S E SystemRoMedic TM

Guidance and manufacturer’s declaration – electromagnetic immunity

The EvaDrive is intended for use in the electromagnetic environment specified below. The customer or the user of the EvaDrive should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance Electrostatic discharge (ESD) IEC 61000-4-2 +/- 6 kV contact +/- 8 kV air +/- 6 kV contact +/- 8 kV air Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. Electrical fast transient / Burst IEC 61000-4-4 +/- 2 kV for power supply lines +/- 1 kV for input/output lines +/- 2 kV for power supply lines +/- 1 kV for input/ output lines Mains power quality should be that of a typical commercial or hospital environment. Surge IEC 61000-4-5 +/- 1 kV differential mode +/- 2 kV common mode +/- 1 kV differential mode +/- 2 kV for common mode Mains power quality should be that of a typical commercial or hospital environment. Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 <5 % UT (>95 % dip in UT) for 0,5 cycle 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles <5 % UT (>95 % dip in UT)) for 5 sec <5 % UT (>95 % dip in UT) for 0,5 cycle 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles <5 % UT (>95 % dip in UT)) for 5 sec Mains power quality should be that of a typical commercial or hospital environment. If the user of the [Equipment or System] requires continued operation during power mains interruptions, it is recommended that the [Equipment or System] be powered from an uninterruptible power supply or battery. Power frequency (50/60 Hz) magnetic field IEC 61000-4-8 3 A/m 30 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment NOTE UT is the a.c. mains voltage prior to application of the test level. 127 I N S T R U C T I O N S F O R U S E SystemRoMedic TM

Guidance and manufacturer’s declaration – electromagnetic immunity

The EvaDrive is intended for use in the electromagnetic environment specified below. The customer or the user of the EvaDrive should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance Portable and mobile RF communications equipment should be used no closer to any part of the EvaDrive, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Conducted RF IEC 61000-4-6 3 Vrms 150 kHz to 80 MHz 3 Vrms Recommended separation distance P d 2,1 = Radiated RF IEC 61000-4-3 3 V/m 80MHz to 2,5GHz 3 V/m P d 2,1 = 80 MHz to 800 MHz P d 3,2 = 800 MHz to 2,5 GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range. b Interference may occur in the vicinity of equipment marked with the following symbol. NOTE 1 At 80MHz and 800MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflected from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the EvaDrive is used exceeds the applicable RF compliance level above, the EVADRIVE should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the EvaDrive. b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 10 V/m. EN-ISO 10535:2006 10 V/m 800MHz to 2GHz 10 V/m EN 61000-4-3: Extended the frequency range 2,5 GHz – 2,7 GHz. EN 61000-4-3: Extended test level of 10 V/m for frequency range 1,0 GHz – 2,0 GHz. EN 61000-4-8: Extended test level of 30 A/m. 128 I N S T R U C T I O N S F O R U S E SystemRoMedic TM

Recommended separation distances between portable and mobile RF communications

equipment and the EvaDrive The EVADRIVE is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the EvaDrive can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the EvaDrive as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz P d 2,1 = 80 MHz to 800 MHz P d 2,1 = 800 MHz to 2.5 GHz P d 3,2 = 0.01 0.12 0.12 0.24 0.1 0.38 0.38 0.73 1 1,2 1.2 2.3 10 3,8 3.8 7.3 100 12 12 23 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. Note 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. 129 I N S T R U C T I O N S F O R U S E SystemRoMedic TM

Simple solutions for great results

SystemRoMedic™ is the name of Handicare’s unique easy transfer concept, the market’s widest and most comprehensive range of clever, easy-to-use and safe transfer and lifting aids designed to make life easier, both for the user and for the caregiver. SystemRoMedic™ is a complete solution that provides for the majority of patient transfer or manual handling requirements. From the simplest to the most complex scenarios, from the lightest to the heaviest. The concept encompasses assistive devices for four different categories of transfers: • Transfer, assistive devices for manual transfers of users between two locations. • Positioning, assistive devices for manual repositioning of users within the same location. • Support, assistive devices for mobility support e.g., during sit-to-stand or gait training. • Lifting, assistive devices for manual and mechanical lifting of users. Improved work environment, improved quality of care and cost savings The philosophy behind SystemRoMedic™ is focused on the prevention and reduction of occupational injuries while allowing users to experience a greater sense of independence and dignity. Through a unique combination of training and a complete range of efficient transfer aids, SystemRoMedic™ offers improvement of both work environment and quality of care and, at the same time, achieves significant cost savings. Always make sure that you have the correct version of the manual The most recent version of all manuals are available for downloading from our website; www.handicare.com. For questions about the product and its use Please contact your local Handicare and SystemRoMedic™ representative. A complete list of all our partners with their contact details can be found on our website; www.handicare.com. SystemRoMedic TM Handicare offers solutions and support to increase the independence of disabled or elderly people as well as to improve the convenience of those who are caring for them. The Handicare Group is one of the leading healthcare companies in Europe with its own manufacturing organizations and sales companies in Norway, Sweden, Denmark, Germany, the Netherlands, Great Britain, France, China, Canada and the USA. Handicare’s products are also distributed by partners in more than 40 countries worldwide. Our wide range of high-quality products includes a complete easy transfer system and other patient handling aids, stairlifts, car adaptations and bathing and toileting products. Handicare AB is quality and environmentcertified in accordance with ISO 9001, ISO 13485 and ISO 14001. Handicare AB Torshamnsgatan 35 SE-164 40 Kista, SWEDEN Tel: +46 (0)8-557 62 200 Fax:+46 (0)8-557 62 299 E-mail: [email protected] www.handicare.com