Geokon 8800 Product Tutorial

Text of Geokon 8800 Product Tutorial

Many hardware and software issues can be prevented or

resolved with a better understanding of the product Please read the Installing GeoNet Wireless Data Hosting Systems and Using Agent Software with GeoNet Wireless Data Hosting Systems tutorials and review the product manuals prior to attempting to troubleshoot a Network Before Continuing

Always mount GeoNet

devices vertically, with the antenna pointing up The space around the antenna should be free of obstructions A minimum mounting height of two meters (six-feet) is recommended Device Mounting

around, or near GeoNet

devices can cause reflections of the radio signal Reflected radio signals can cause GeoNet devices to malfunction For optimum performance, create as much space as possible between the straight- line radio path and any obstructions (especially metallic objects) Device Mounting (Continued)

Geokon 8800 ►Not enough clear space

around the antenna ►Mounting devices horizontally ►Metallic objects nearby The photos to the right show examples of improper device mounting Device Mounting (Continued)

All GeoNet devices are set to operate on the same channel at

the factory Channels only need to be set if multiple networks will be operating within radio range of one another Networks within radio range of one another must not be set to the same channel Up to 12 Networks can operate in the same area by utilizing a different channel for each Network Setting Channels

To set the channels on a

device: 1. Activate Deployment mode 2. Move the channel switches to one of the 12 valid settings 3. Press the reset button GeoNet Devices can only communicate when set to the same channel, therefore, ALL DEVICES in a network must be set to the same channel Setting Channels (Continued)

Must be used when making changes to a network

(adding Nodes, changing batteries, resetting a device, etc.) Indicated by the LEDs on the Supervisor flashing every 10-15 seconds Automatically activated when Supervisor is powered Active for 60 minutes by default (Can be changed using Agent software) Can be reactivated/reset by pressing the status button on the Supervisor (May take up to 6 minutes to take effect) Deployment Mode

Geokon 8800 Avoid powering down or

removing the Supervisor from a working Network If the Supervisor must be powered down or removed, activate deployment mode prior to doing so When downloading data via a direct PC connection, bring the PC to the Supervisor rather than removing the Supervisor from the Network Supervisors Control the Network

The Network must be put into deployment mode prior to

replacing the batteries in the Supervisor (Also best practice when replacing batteries in Nodes) Replace D cell batteries when voltage drops below 2.0 VDC Replace 12-volt external batteries when voltage is below 11 volts All data is stored in nonvolatile flash memory, and will be retained even if the batteries are absent for an extended period After replacing the batteries in a Node, make

Changes to “deploy period”

will take effect the next time Deployment mode is activated on the Supervisor Turn off automatic download before changing the “scan rate” Software Tips

Make sure the Network is

in deployment mode (one or both of the LEDs on the Supervisor flashing every 10-15 seconds) Verify that all four channel dipswitches inside the Node are set to the same position as the switches inside the Supervisor Devices will only communicate when set to the same channel Power the Node while it is in close proximity to the Supervisor Node will not Join the Network: Flashing Red LED Node Supervisor

If a Node still will not join the Network after the previous

suggestions have been tried, it may be out of synch with the Supervisor The Node will join the Network if given enough time, however, the connection can be expedited by resetting the Node To reset a Node, press the reset button inside the enclosure, or, hold down the status button until the red and green LEDs turn on, then release the button Resetting a Node

Complete the following:

1. Make sure the Network is in deployment mode 2. Power down the Node 3. Position the Node so that it is in close proximity to the Supervisor (or a Node that has successfully joined the Network) 4. Power up the Node and wait for it to join the Network 5. Move the Node to its intended location If the Network connection is lost when the Node is in its original location, try to improve the radio signal by completing the steps in

Geokon Data Loggers Owners Instructions: