P/N 108919-01 P.O. BOX 90024 REV D BOWLING GREEN, KY 42101-9004 6/02 www.desatech.com SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when nee ...
CONTENTS 1. INTRODUCTION ------------------------------------------------------------- PG. 2 2. SELECTING LOCATION ------------------------------------------------------------- PG. 2 3. MINIMUM CLEARANCES ------------------------------------------------------------- PG. 2 4. FRAMING AND INSTALLING -------------------------------------------------- ...
INTRODUCTION BEFORE BEGINNING THE INSTALLATION OF THE FIREPLACE, READ THESE INSTRUCTIONS THROUGH, COMPLETELY. ♦ This DESA fireplace and its components are safe when installed according to this installation manual. Unless you use DESA components, which has been designed and tested for the fireplace system, you may cause a fire hazard. ♦ The DESA warranty will be ...
FRAMING AND INSTALLING THE FIREPLACE STEP 1: Frame the opening for the fireplace using the dimensions shown in figures 1 & 2. STEP 2: If the fireplace is to be installed directly on carpeting, tile (other than ceramic), or any combustible material other than wood flooring, the fireplace must be installed upon a metal or wood panel extending the full width and depth ...
OUTSIDE AIR KIT (MODEL AK-6) The installation of an outside air kit should be performed during the rough framing of the fireplace due to the nature of its location. Outside combustion air is accessed through the mobile home floor (Refer to AK-6 Installation Instructions for details). In some instances, a wall installation is required (see Figure 5). Note: An AK- ...
ASSEMBLY AND INSTALLATION OF THE DOUBLE WALL CHIMNEY SYSTEM Each double wall chimney section is consist of a galvanized outer pipe, a stainless steel inner flue pipe and a wire spacer. The pipe sections must be assembled independently as the chimney is installed. When connecting chimney directly to the fireplace, the inner flue pipe section must be installed first ...
If the adapter is needed, secure it onto the firestop using holes provided (see figure 10). The row of holes on the sides of the thimble is provided to allow for pitch variances. Position the firestop assembly and thimble to desired angle and secure with screws provided. Insert the thimble and firestop into the prepared opening and secure to the ceiling by naili ...
FLASHING INSTALLATION (V6F-8DM or V12F-8DM) Determine the flashing to be used with the roof opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nailing through shingles (see figure 15). DO NOT NAIL THROUGH FLASHING CONE. INSTALLING FLASHING ON A M ...
CHASE INSTALLATIONS Instructions for chase installations are included with the chase style termination chosen. In a multiple chase installation, be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another. We suggest that terminations be separated at least 24 inches, center to center and stacked at vertical hei ...
IMPORTANT: The glass must be allowed to warm slowly and evenly. The tempered glass will withstand a gradual temperature rise to 550 degrees Fahrenheit, which is more than a normal fire will generate. Such materials as pitch/wax laden logs, very dry mill end lumber, and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be bu ...
IF YOU WISH TO INSTALL AN UNVENTED (VENT- FREE) GAS LOG SET, ONLY UNVENTED GAS LOG SETS WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD FOR UNVENTED ROOM HEATERS, ANSI Z21.11.2, ARE TO BE INSTALLED IN THIS FIREPLACE. NOTE: A DESA hood must be installed when using an unvented gas log set (see accessories on page 12). If you install a decorative gas appliance (vented gas l ...
ILLUSTRATED PARTS ...
ILLUSTRATED PARTS ITEM # PART # DESCRIPTION QTY. ITEM # PART # DESCRIPTION QTY. 1 54002 WARRANTY, HOME OWNERS BOOK 1 *32 108857-02 DOOR ASSEMBLY-LT 1 2 108307-01 PAN, INSULATION 1 *33 108856-02 DOOR ASSEMBLY-RT 1 3 108305-01 TOP, FIREPLACE 1 *34 56090 COLEMAN DECAL 1 4 108304-01 SURROUND, FIREPLACE 1 *35 106574-01 INSTALL INSTRUCTION AK-6 1 5 108301-01 FLOOR, FIREBOX 1 *3 ...
CONTENTS MW8K MW9K 8' vent kit 9' vent kit 36-8DM 36" Double Wall Pipe 2 2 24-8DM 24" Double Wall Pipe 1 0 18-8DM 18" Double Wall Pipe 0 2 FST-A Adjustable Firestop Thimble 1 1 V6F-8DM Roof Flashing 1 1 VSC1-8DM Storm Collar 1 1 RTL-8DM Round Cap Termination 1 1 VENT KITS - USE FOR MOST COMMON MANUFACTURED (MOBILE) HOME INSTALLATIONS REPLACEMENT PARTS ACCESSORY P ...
PART NUMBER REFERENCE TABLE* *Part numbers listed on this chart on the same line and identified by the same description are interchangeable and listed as “same as”. Each part so listed may be substituted for the other part numbers under that listing. MODEL DESCRIPTION COLEMAN PART # DESA PART # BK3 TRIPLE FAN BLOWER KIT ----- BK3 EP-36 EMBER PROTECTOR 9736-5601 20093 ...