Analog Technologies VC60B Manual 

Brand: Analog Technologies
Category: Multimeter
Model: VC60B (Manual )
File Type: PDF
File Size: —
Pages: 7
Text of Analog Technologies VC60B Manual 

Analog Technologies VC60B 2352 Walsh Ave. Santa Clara, CA 95051. U. S. A. Tel.: (408) 748-9100, Fax: (408) 748-9111 www.analogtechnologies.com

Copyrights 2000 – 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 1 Analog Technologies VC60B Multimeter Figure 1. The Photo of Actual VC60B Figure 2. The Photo of Actual VC60B Figure 3. The Photo of Actual VC60B FEATURES Altitude: <2000m Power Consumption: <650mW Sampling Rate: Approx. 3 times/s
2352 Walsh Ave. Santa Clara, CA 95051. U. S. A. Tel.: (408) 748-9100, Fax: (408) 748-9111 www.analogtechnologies.com Copyrights 2000 – 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 2 Analog Technologies VC60B Multimeter GENERAL SPECIFICATIONS Table 1. Altitude <2000m Fuse 100mA/60V resettable fuse Sampling Rate Approx.3 times/sec Power Source 5# Battery LR6 (1.5V) ×6 (or External AC Adapter) Power Consumption
2352 Walsh Ave. Santa Clara, CA 95051. U. S. A. Tel.: (408) 748-9100, Fax: (408) 748-9111 www.analogtechnologies.com Copyrights 2000 – 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 3 Analog Technologies VC60B Multimeter ACV Frequency Response 50 Hz ~ 200Hz Note: Median resistance – makes sure that the voltage of both testing sides does not lower than 90% of the resistance’s normal voltage lower limit. Table
2352 Walsh Ave. Santa Clara, CA 95051. U. S. A. Tel.: (408) 748-9100, Fax: (408) 748-9111 www.analogtechnologies.com Copyrights 2000 – 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 4 Analog Technologies VC60B Multimeter INSULATION RESISTANCE MEASUREMENT Figure 4. Insulation Resistance Measurement 1. According to testing request, tune the function switch to a suitable function 2.
2352 Walsh Ave. Santa Clara, CA 95051. U. S. A. Tel.: (408) 748-9100, Fax: (408) 748-9111 www.analogtechnologies.com Copyrights 2000 – 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 5 Analog Technologies VC60B Multimeter 4. Do not input voltage to the resistance range! DCV MEASUREMENT 1. Tune the function switch to DC 1000V range. 2. Connect the red lead to “V/Ω” input terminal and black lead to “G”
2352 Walsh Ave. Santa Clara, CA 95051. U. S. A. Tel.: (408) 748-9100, Fax: (408) 748-9111 www.analogtechnologies.com Copyrights 2000 – 2012, Analog Technologies, Inc. All Rights Reserved. Updated on 11/22/2012 6 Analog Technologies VC60B Multimeter 10. When use 9V battery, if the LCD displays low battery symbol “ ”, replace battery according to the following steps. Table 4. Step Item Description 1 Use a screw driver to open the batter

Analog Technologies Multimeter Owners Instructions: