Firefighter EC-FF2-433 Installation Manual & Users Manual

Text of the manual

US Patent # 9,087,447

Installation Manual & Users Guide SPECIFICATIONS Frequency: 433.92MHz Operating Temperature: 32°-120°F (0°-49°C) Battery: One 3Vdc lithium CR123A (1550 mAh) Operating Humidity: 5-95% RH non condensing Battery life: 5 years Compatible with 433MHz DSC Security Systems Detection distance: 6 in max Supervis

Re-attach the cover, you should hear a click when the cover engages properly.

WARNING: While the audio detector monitors its own battery, it does not monitor the battery in the smoke detectors. Batteries should be changed as per the original smoke detector manufacturer’s instructions. Always test the audio detector and smoke alarms after battery install