UNI-T UT39E Operating Manual

Text of UNI-T UT39E Operating Manual

TABLE OF CONTENTS

TITLE PAGE Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Display Symbols Measurement Operation A. DC Voltage Measurement B. AC Voltage Measurement C. DC Current Measurement D. AC Current Measurement E. Measuring Resistance F. Measuring Diodes & Continuity G. Frequency Measurement H. Cap

To avoid electric shock or personal injury, read the

“Safety Information” and “Rules for Safety Operation” carefully before using the Meter. Digital Multimeter Model UT39E (hereafter referred to as “the Meter”) is a 4 1/2 digits with steady operations, fashionable structure and highly reliable hand-held measuring instrument. The Meter uses large scale of integrated circuit with double integrated A/D converter as its core and ha

This Meter complies with the standards IEC61010: in

pollution degree 2, overvoltage category (CAT. I 1000V, CAT. II 600V) and double insulation. CAT. I: Signal level, special equipment or parts of equipment, telecommunication, electronic, etc., with smaller transient overvoltages than overvoltages CAT. II. CAT. II: Local level, appliance, PORTABLE EQUIPMENT etc., with smaller transient voltage overvoltages than CAT. III Use the Meter o

The rotary switch should be placed in the right

position and no any changeover of range shall be made during measurement is conducted to prevent damage of the Meter. When the Meter working at an effective voltage over 60V in DC or 30V rms in AC, special care should be taken for there is danger of electric shock. Use the proper terminals, function, and range for your measurements. Do not use or store the Meter in an environment of high temperature, humidity

UNI-T UT39E International Electrical Symbols

Deficiency of Built-In Battery AC (Alternating Current) AC or DC Double Insulated Warning. Refer to the Operating Manual Conforms to Standards of European Union Grounding DC (Direct Current) Diode Continuity Test Fuse The Meter Structure (see figure 1) 1. LCD Display 2.Data Hold Button 3.Transistor Jack 4. COM Input Terminal 5. Other Input Terminals 6. mA Input Terminal 7. 20A Input Terminal 8. Capacitance Jack 9. Rotary Sw

Below table indicated for information about the functional

button operations Button POWER (Yellow Button) HOLD (Blue Button) Operation Performed Turn the Meter on and off. Press down the POWER to turn on the Meter. Press up the POWER to turn off the Meter. Press HOLD once to enter hold mode. Press HOLD again to exit hold mode. In Hold mode, is displayed and the present value is shown. l l l l l Display Symbols

Make sure the Sleep Mode is not on if you found there

is no display on the LCD after turning on the Meter. Make sure the Low Battery Display is not on, otherwise false readings may be provided. Pay extra attention to the symbol which is located besides the input terminals of the Meter before carrying out measeurement. l l l A. DC Voltage Measurement (see figure 3) Warning To avoid harms to you or damages to the Meter from electr

If the value of voltage to be measured is unknown,

use the maximum measurement position (1000V) and reduce the range step by step until a satisfactory reading is obtained. The LCD displays “1” indicating the existing selected range is overloaded, it is required to select a higher range in order to obtain a correct reading. In each range, the Meter has an input impedance of approx. 10MΩ. This loading effect can cause measurement errors in high impedan

The LCD displays “1” indicating the existing selected

range is overloaded, it is required to select a higher range in order to obtain a correct reading. In each range, the Meter has an input impedance of approx. 10MΩ. This loading effect can cause measurement errors in high impedance circuits. If the circuit impedance is less than or equal to 10kΩ, the error is negligible (0.1% or less). When AC voltage measurement has been completed, disconnect

UNI-T UT39E If the value of current to be measured is unknown,

use the maximum measurement position (20A) and 20A terminal, and reduce the range step by step until a satisfactory reading is obtained. Replace appropriate rating fuse when the fuse is burnt. Fuse specification: 0.315A. 250V fast type fuse, φ 5 x 20mm At 20A Range: For continuous measurement 10 seconds and interval not less than 15 minutes. When current measurement has been completed, disconnect the co

To measure current, do the following:

1. Turn off power to the circuit. Discharge all high-voltage capacitors. 2. Insert the red test lead into the mA or 20A terminal and the black test lead into the COM terminal. When measuring current at 200mA below, insert the red test lead into mA terminal while measuring current 200mA or above, insert the red test lead into 20A terminal 3. Set the rotary switch to an appropriate measurement po

E. Measuring Resistance (see figure 5)

Warning To avoid damages to the Meter or to the devices under test, disconnect circuit power and discharge all the high-voltage capacitors before measuring resistance. To measure resistance, connect the Meter as follows: 1. Insert the red test lead into the VΩ terminal and the black test lead into the COM terminal. 2. Set the rotary switch to an appropriate measurement position in Ω range. 3. Connect the t

UNI-T Multimeter Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated For Device
UT70C

Multimeter #T7P97E

48 0.55 Mb 134 33 23-04-2026 view all
UT71C

UNI-T UT71C User Manual (Operating manual), @16948L

72 1040 156 01-08-2026 view all
UT39E

UNI-T Multimeter Operating manual (File: PDF, 22-08-2026)

24 0.45 Mb 907 155 22-08-2026 view all
UT209

UNI-T UT209 Manual (Operating manual), @KU5L2A

46 0.83 Mb 608 116 16-06-2026 view all
UT801

Multimeter #RTC48R

2 763 161 16-06-2026 view all
UT33B

UNI-T UT33B Manual (Operating manual), @DB4ST2

42 0.25 Mb 1277 269 31-05-2026 view all
UT8803

UT8803 (Multimeter ePDF User Manual, #Q88BLE)

30 621 106 21-05-2026 view all
UT205A

Multimeter #6D6GW1

2 1215 207 17-06-2026 view all
UT695D Series

UNI-T Multimeter Operation & user’s manual (File: PDF, 09-09-2026)

2 710 157 09-09-2026 view all
UT804

UNI-T Multimeter Operating manual (File: PDF, 08-04-2026)

70 1.66 Mb 597 126 08-04-2026 view all